Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 78
Filtrar
1.
J Esthet Restor Dent ; 2024 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-38923112

RESUMO

OBJECTIVE: The present clinical report describes a long-term temporary restorative approach using injectable composite to reshape a canine into a central incisor, within the context of an ongoing orthodontic treatment. This treatment protocol describes a fully-digital workflow, incorporating digital designed and 3D printed diagnostic wax up, reduction guides and resin-injection index. CLINICAL CONSIDERATIONS: Effective planning is important when aiming to deliver a comprehensive and multidisciplinary workflow, and digital tools serve as invaluable aids. CONCLUSION: The use of a fully digital workflow in a comprehensive dental treatment resulted in a predictable and successful outcome for a restoration of a canine that was transformed into a central incisor. CLINICAL SIGNIFICANCE: This approach highlights the efficacy of digital technology in achieving precise and successful dental restorations, emphasizing its significance in modern dental practice.

2.
Braz Oral Res ; 38: e030, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38597548

RESUMO

This study aimed to evaluate volumetric polymerization shrinkage, degree of conversion and Vickers hardness of four bulk-fill resin composites light-activated with their dedicated light curing units (LCUs). Four groups were evaluated, according to the type of composite and curing mode: Tetric EvoCeram Bulk-fill (TEBO) and Tetric EvoFlow Bulk-fill (TEBF) were light-activated with Bluephase Style 20i (20s, in high-mode), while Tetric Powerfill (TEPO) and Tetric Powerflow (TEPF) were light-activated with Bluephase PowerCure (3s). Volumetric polymerization shrinkage test (n = 6) was performed in standardized box-shaped class-I cavities of extracted third molars (4 x 4 x 4 mm). Teeth were scanned before and after resin composite application by micro-computed tomography, and acquired data were evaluated with Amira software. Degree of conversion (n = 5) was evaluated at the top and bottom surfaces of composite cylindric samples (4 mm diameter, 4 mm thickness) using an FT-IR spectrometer (spectra between 1,500 and 1,800 cm-1, 40 scans at a resolution of 4 cm-1). Three Vickers indentations (50 g / 15 s), spaced 500 µm apart, were performed on the top and bottom composite surfaces and averaged. One-way ANOVA was used for data evaluation. TEPF showed the lowest volumetric polymerization shrinkage (p < 0.05), while the other composites were not significantly different within each other (p > 0.05). All materials presented a significant decrease in degree of conversion and Vickers hardness when compared top to bottom surfaces (p < 0.05). Bottom to top surface ratios for degree of conversion ranged from 0.8 (TEBO and TEPO) to 0.9 (TEBF and TEPF), and from 0.4 (TEPO) to 0.7 (TEBF and TEPF) for hardness. In conclusion, resinous materials present a decrease in hardness and degree of conversion from top to bottom even when a higher power is used, while the flowable material TEPF showed the lowest volumetric shrinkage values compared to the other materials.


Assuntos
Resinas Compostas , Cárie Dentária , Humanos , Dureza , Microtomografia por Raio-X , Espectroscopia de Infravermelho com Transformada de Fourier , Teste de Materiais , Polimerização , Propriedades de Superfície , Materiais Dentários
3.
J Esthet Restor Dent ; 2024 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-38546152

RESUMO

OBJECTIVE: To describe a shift from injectable resin composite technique to composite resin computer-aided design and computer-aided manufacturing (CAD/CAM) veneers in addressing esthetic concerns associated with diastemas between anterior lower teeth in a clinical case. CLINICAL CONSIDERATIONS: Among several techniques proposed for direct resin composite restoration, the "Injectable resin composite technique" has gained popularity for its time-efficiency, reduced technique sensitivity, and diminished reliance on clinician skills. However, challenges such as staining and the need for frequent polishing follow-ups may prompt the consideration of more stable alternatives such as indirect veneer restorations. While ceramic veneers offer superior mechanical and optical properties, resin ceramic veneers, especially those milled from CAD/CAM resin ceramic blocks, offer advantages such as rapid, cost-effective production, simplified intra-oral repairs, less susceptibility to fracture, superior stress absorption, and requires minimal tooth preparation, making them an appealing option for many patients. Moreover, a fully-digital approach not only streamlines the process but also saves time and labor while ensuring the delivery of high-quality restorations to patients. CONCLUSION: In addressing a patient's dissatisfaction with constant polishing of direct resin composite restorations, a shift to resin composite CAD/CAM veneers was implemented. Utilizing a fully-digital approach with CAD/CAM resin ceramic restorations successfully restored both esthetics and function. CLINICAL SIGNIFICANCE: While the injectable resin composite technique achieves immediate esthetic results, its low color stability necessitates frequent polishing sessions. The replacement of direct resin composite restorations with CAD/CAM resin composite veneers becomes a viable option for patients seeking more stable restorations that require fewer follow-ups. This transition addresses both esthetic concerns and the need for enduring solutions in restorative dentistry.

4.
Quintessence Int ; 55(4): 286-294, 2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38374723

RESUMO

This clinical case outlines a comprehensive digital workflow for a minimally invasive multidisciplinary treatment. The process utilizes one open-source software for digital wax-up and one low-cost software to address esthetic concerns related to teeth misalignment. The patient's function was stabilized with a digitally made occlusal splint. The application of the described digital workflow technique, incorporating open-source, low-cost, and closed software, played a pivotal role in attaining a straightforward and predictable outcome with minimally invasive treatment. Furthermore, the continual evolution of technology contributes to the growing precision of dental procedures. The presented digital workflow helped formulate a predictable treatment plan, replicate a diagnostic digital wax-up, and achieve precise teeth alignment. This approach satisfactorily addressed the patient's esthetic concerns, providing an outstanding approximation of the definitive result.


Assuntos
Estética Dentária , Fluxo de Trabalho , Feminino , Humanos , Desenho Assistido por Computador , Má Oclusão/terapia , Placas Oclusais , Planejamento de Assistência ao Paciente , Software , Adulto Jovem , Adulto
5.
J Clin Exp Dent ; 16(1): e71-e77, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38314337

RESUMO

The natural outcome of dental composite restorations highly depends on the translucency of the enamel layer and fluorescence. This study aimed to evaluate the Translucency Parameter (TP) and Fluorescence Intensity (FI) of five different resin composite systems. Seven discs of each composite brand were prepared in a circular increasing thickness. For TP, a spectrophotometer measured the samples' colors. The color difference within the white/black backgrounds obtained the translucency parameter. For FI, samples were exposed to UV light, and ten photographs per group were taken. Each specimen was analyzed digitally. A mixed model analysis to a 95% confidence level analyzed groups differences. Higher values of TP were observed for ED and EL, followed by FZ. The lowest values were observed for EO and FO. FI values descending order was EL>FO>EO>ED>FZ. The composition of fillers and organic matrix influenced the behavior of fluorescence and translucency of resin composites. Key words:Resin composite, fluorescence, color, translucency parameter.

6.
J Esthet Restor Dent ; 36(1): 32-36, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38142060

RESUMO

OBJECTIVES: This article presents case reports highlighting over-treatments with resin composites, often misconceived as minimally invasive procedures. CLINICAL CONSIDERATIONS: Tooth-colored restorative materials, such as ceramics and composites, have found widespread application to correct problems related to tooth color, shape, and alignment. When composite resin is used, these procedures can be done in a very conservative, cost-effective, and timely fashion. However, it is noteworthy that contemporary dental esthetic expectations are based on standards propagated by social media and other marketing and communications platforms. The abuse of and addiction to social media impacts can lead to unrealistic esthetic expectations and standards for both patients and dentists. CONCLUSIONS: After a critical discussion on ceramic veneers published in part I of this 2-part series, this article directs attention towards what has become a trendy fashion, i.e., the use of direct composite resins as "non-prep" veneers in clinical situations that arguably required no restorative intervention at all. We further explore how social media influences the decision-making processes of both professionals and patients.


Assuntos
Resinas Compostas , Mídias Sociais , Humanos , Estética Dentária , Facetas Dentárias , Materiais Dentários , Cerâmica
7.
Braz. oral res. (Online) ; 38: e030, 2024. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1557363

RESUMO

Abstract This study aimed to evaluate volumetric polymerization shrinkage, degree of conversion and Vickers hardness of four bulk-fill resin composites light-activated with their dedicated light curing units (LCUs). Four groups were evaluated, according to the type of composite and curing mode: Tetric EvoCeram Bulk-fill (TEBO) and Tetric EvoFlow Bulk-fill (TEBF) were light-activated with Bluephase Style 20i (20s, in high-mode), while Tetric Powerfill (TEPO) and Tetric Powerflow (TEPF) were light-activated with Bluephase PowerCure (3s). Volumetric polymerization shrinkage test (n = 6) was performed in standardized box-shaped class-I cavities of extracted third molars (4 x 4 x 4 mm). Teeth were scanned before and after resin composite application by micro-computed tomography, and acquired data were evaluated with Amira software. Degree of conversion (n = 5) was evaluated at the top and bottom surfaces of composite cylindric samples (4 mm diameter, 4 mm thickness) using an FT-IR spectrometer (spectra between 1,500 and 1,800 cm-1, 40 scans at a resolution of 4 cm-1). Three Vickers indentations (50 g / 15 s), spaced 500 μm apart, were performed on the top and bottom composite surfaces and averaged. One-way ANOVA was used for data evaluation. TEPF showed the lowest volumetric polymerization shrinkage (p < 0.05), while the other composites were not significantly different within each other (p > 0.05). All materials presented a significant decrease in degree of conversion and Vickers hardness when compared top to bottom surfaces (p < 0.05). Bottom to top surface ratios for degree of conversion ranged from 0.8 (TEBO and TEPO) to 0.9 (TEBF and TEPF), and from 0.4 (TEPO) to 0.7 (TEBF and TEPF) for hardness. In conclusion, resinous materials present a decrease in hardness and degree of conversion from top to bottom even when a higher power is used, while the flowable material TEPF showed the lowest volumetric shrinkage values compared to the other materials.

8.
Artigo em Inglês | MEDLINE | ID: mdl-36661887

RESUMO

This study evaluated shear bond strength (SBS) of thermally aged composite resins repaired using different surface protocols. Four-hundred composite resin samples were made using the following materials (100 samples per material): Filtek Z350XT (FXT); Spectra Smart (SSM); IPS Empress Direct (EDI); and Forma (FOR). Each group's samples were then divided into 10 groups (n = 10 samples per group): G1: no surface treatment; G2: phosphoric acid-etching + universal-adhesive (PU); G3: surface roughening + PU (RPU); G4: RPU + silane (RPSU); G5: surface roughening + hydrofluoric acid-etching + universal adhesive (RHU); G6: RHU + silane (RHSU); G7: dry sandblast + PU (DsPU); G8: DsPU + silane (DsPSU); G9: wet sandblast + PU (WsPU); and G10: WsPU + silane (WsPSU). G1 was freshly repaired, and G2 to G10 were thermally aged before repair. Specimens were tested for SBS, and the failure type was observed with a magnifying loupe. Representative images were obtained using a scanning electronic microscope. Data were analyzed by two-way analysis of variance and Tukey post hoc tests (P = .05). Differences were detected among different surface treatments and among different composite resins with equal surface treatments (P < .05). SBS means ranged from 10.48 (FOR:G2) to 20.70 (FXT:G7). The highest SBS values were seen in G7 to G10 (P > .05), while lowest values were generally observed for G2. G1 showed higher results compared to G2 (P < .05), except for EDI (P > .05). Most failures corresponded with cohesive type. In general, thermally aged composite resin presented a decreased repair bond strength potential when no additional surface treatment was applied. Sandblasting improved the SBS of repaired aged composite resins.


Assuntos
Resinas Compostas , Colagem Dentária , Humanos , Idoso , Resinas Compostas/química , Colagem Dentária/métodos , Silanos/química , Protocolos Clínicos , Propriedades de Superfície , Teste de Materiais , Resistência ao Cisalhamento , Cimentos de Resina/química , Análise do Estresse Dentário
9.
Tomazini, Bruno M; Nassar Jr, Antonio Paulo; Lisboa, Thiago Costa; Azevedo, Luciano César Pontes de; Veiga, Viviane Cordeiro; Catarino, Daniela Ghidetti Mangas; Fogazzi, Debora Vacaro; Arns, Beatriz; Piastrelli, Filipe Teixeira; Dietrich, Camila; Negrelli, Karina Leal; Jesuíno, Isabella de Andrade; Reis, Luiz Fernando Lima; Mattos, Renata Rodrigues de; Pinheiro, Carla Cristina Gomes; Luz, Mariane Nascimento; Spadoni, Clayse Carla da Silva; Moro, Elisângela Emilene; Bueno, Flávia Regina; Sampaio, Camila Santana Justo Cintra; Silva, Débora Patrício; Baldassare, Franca Pellison; Silva, Ana Cecilia Alcantara; Veiga, Thabata; Barbante, Leticia; Lambauer, Marianne; Campos, Viviane Bezerra; Santos, Elton; Santos, Renato Hideo Nakawaga; Laranjeiras, Ligia Nasi; Valeis, Nanci; Santucci, Eliana; Miranda, Tamiris Abait; Patrocínio, Ana Cristina Lagoeiro do; Carvalho, Andréa de; Sousa, Eduvirgens Maria Couto de; Sousa, Ancelmo Honorato Ferraz de; Malheiro, Daniel Tavares; Bezerra, Isabella Lott; Rodrigues, Mirian Batista; Malicia, Julliana Chicuta; Silva, Sabrina Souza da; Gimenes, Bruna dos Passos; Sesin, Guilhermo Prates; Zavascki, Alexandre Prehn; Sganzerla, Daniel; Medeiros, Gregory Saraiva; Santos, Rosa da Rosa Minho dos; Silva, Fernanda Kelly Romeiro; Cheno, Maysa Yukari; Abrahão, Carolinne Ferreira; Oliveira Junior, Haliton Alves de; Rocha, Leonardo Lima; Nunes Neto, Pedro Aniceto; Pereira, Valéria Chagas; Paciência, Luis Eduardo Miranda; Bueno, Elaine Silva; Caser, Eliana Bernadete; Ribeiro, Larissa Zuqui; Fernandes, Caio Cesar Ferreira; Garcia, Juliana Mazzei; Silva, Vanildes de Fátima Fernandes; Santos, Alisson Junior dos; Machado, Flávia Ribeiro; Souza, Maria Aparecida de; Ferronato, Bianca Ramos; Urbano, Hugo Corrêa de Andrade; Moreira, Danielle Conceição Aparecida; Souza-Dantas, Vicente Cés de; Duarte, Diego Meireles; Coelho, Juliana; Figueiredo, Rodrigo Cruvinel; Foreque, Fernanda; Romano, Thiago Gomes; Cubos, Daniel; Spirale, Vladimir Miguel; Nogueira, Roberta Schiavon; Maia, Israel Silva; Zandonai, Cassio Luis; Lovato, Wilson José; Cerantola, Rodrigo Barbosa; Toledo, Tatiana Gozzi Pancev; Tomba, Pablo Oscar; Almeida, Joyce Ramos de; Sanches, Luciana Coelho; Pierini, Leticia; Cunha, Mariana; Sousa, Michelle Tereza; Azevedo, Bruna; Dal-Pizzol, Felipe; Damasio, Danusa de Castro; Bainy, Marina Peres; Beduhn, Dagoberta Alves Vieira; Jatobá, Joana DArc Vila Nova; Moura, Maria Tereza Farias de; Rego, Leila Rezegue de Moraes; Silva, Adria Vanessa da; Oliveira, Luana Pontes; Sodré Filho, Eliene Sá; Santos, Silvana Soares dos; Neves, Itallo de Lima; Leão, Vanessa Cristina de Aquino; Paes, João Lucidio Lobato; Silva, Marielle Cristina Mendes; Oliveira, Cláudio Dornas de; Santiago, Raquel Caldeira Brant; Paranhos, Jorge Luiz da Rocha; Wiermann, Iany Grinezia da Silva; Pedroso, Durval Ferreira Fonseca; Sawada, Priscilla Yoshiko; Prestes, Rejane Martins; Nascimento, Glícia Cardoso; Grion, Cintia Magalhães Carvalho; Carrilho, Claudia Maria Dantas de Maio; Dantas, Roberta Lacerda Almeida de Miranda; Silva, Eliane Pereira; Silva, Antônio Carlos da; Oliveira, Sheila Mara Bezerra de; Golin, Nicole Alberti; Tregnago, Rogerio; Lima, Valéria Paes; Silva, Kamilla Grasielle Nunes da; Boschi, Emerson; Buffon, Viviane; Machado, André SantAna; Capeletti, Leticia; Foernges, Rafael Botelho; Carvalho, Andréia Schubert de; Oliveira Junior, Lúcio Couto de; Oliveira, Daniela Cunha de; Silva, Everton Macêdo; Ribeiro, Julival; Pereira, Francielle Constantino; Salgado, Fernanda Borges; Deutschendorf, Caroline; Silva, Cristofer Farias da; Gobatto, Andre Luiz Nunes; Oliveira, Carolaine Bomfim de; Dracoulakis, Marianna Deway Andrade; Alvaia, Natália Oliveira Santos; Souza, Roberta Machado de; Araújo, Larissa Liz Cardoso de; Melo, Rodrigo Morel Vieira de; Passos, Luiz Carlos Santana; Vidal, Claudia Fernanda de Lacerda; Rodrigues, Fernanda Lopes de Albuquerque; Kurtz, Pedro; Shinotsuka, Cássia Righy; Tavares, Maria Brandão; Santana, Igor das Virgens; Gavinho, Luciana Macedo da Silva; Nascimento, Alaís Brito; Pereira, Adriano J; Cavalcanti, Alexandre Biasi.
Rev. bras. ter. intensiva ; 34(4): 418-425, out.-dez. 2022. tab, graf
Artigo em Português | LILACS-Express | LILACS | ID: biblio-1423667

RESUMO

RESUMO Objetivo: Descrever o IMPACTO-MR, um estudo brasileiro de plataforma nacional em unidades de terapia intensiva focado no impacto das infecções por bactérias multirresistentes relacionadas à assistência à saúde. Métodos: Descrevemos a plataforma IMPACTO-MR, seu desenvolvimento, critérios para seleção das unidades de terapia intensiva, caracterização da coleta de dados, objetivos e projetos de pesquisa futuros a serem realizados na plataforma. Resultados: Os dados principais foram coletados por meio do Epimed Monitor System® e consistiram em dados demográficos, dados de comorbidades, estado funcional, escores clínicos, diagnóstico de internação e diagnósticos secundários, dados laboratoriais, clínicos e microbiológicos e suporte de órgãos durante a internação na unidade de terapia intensiva, entre outros. De outubro de 2019 a dezembro de 2020, 33.983 pacientes de 51 unidades de terapia intensiva foram incluídos no banco de dados principal. Conclusão: A plataforma IMPACTO-MR é um banco de dados clínico brasileiro de unidades de terapia intensiva focado na pesquisa do impacto das infecções por bactérias multirresistentes relacionadas à assistência à saúde. Essa plataforma fornece dados para o desenvolvimento e pesquisa de unidades de terapia intensiva individuais e ensaios clínicos observacionais e prospectivos multicêntricos.


ABSTRACT Objective: To describe the IMPACTO-MR, a Brazilian nationwide intensive care unit platform study focused on the impact of health care-associated infections due to multidrug-resistant bacteria. Methods: We described the IMPACTO-MR platform, its development, criteria for intensive care unit selection, characterization of core data collection, objectives, and future research projects to be held within the platform. Results: The core data were collected using the Epimed Monitor System® and consisted of demographic data, comorbidity data, functional status, clinical scores, admission diagnosis and secondary diagnoses, laboratory, clinical, and microbiological data, and organ support during intensive care unit stay, among others. From October 2019 to December 2020, 33,983 patients from 51 intensive care units were included in the core database. Conclusion: The IMPACTO-MR platform is a nationwide Brazilian intensive care unit clinical database focused on researching the impact of health care-associated infections due to multidrug-resistant bacteria. This platform provides data for individual intensive care unit development and research and multicenter observational and prospective trials.

10.
Int J Biol Macromol ; 215: 434-449, 2022 Aug 31.
Artigo em Inglês | MEDLINE | ID: mdl-35752332

RESUMO

In this review we have focused on the preparation of cross-linked enzyme aggregates (CLEAs) from lipases, as these are among the most used enzyme in bioprocesses. This immobilization method is considered very attractive due to preparation simplicity, non-use of supports and the possibility of using crude enzyme extracts. CLEAs provide lipase stabilization under extreme temperature or pH conditions or in the presence of organic solvents, in addition to preventing enzyme leaching in aqueous medium. However, it presents some problems in the preparation and limitations in their use. The problems in preparation refer mainly to the crosslinking step, and may be solved using an aminated feeder. The problems in handling have been tackled designing magnetic-CLEAs or trapping the CLEAs in particles with better mechanical properties, the substrate diffusion problems has been reduced by producing more porous-CLEAs, etc. The enzyme co-immobilization using combi-CLEAs is also a new tendency. Therefore, this review explores the CLEAs methodology aimed at lipase immobilization and its applications.


Assuntos
Enzimas Imobilizadas , Lipase , Reagentes de Ligações Cruzadas/química , Estabilidade Enzimática , Enzimas Imobilizadas/química , Lipase/química , Temperatura
11.
Int. j interdiscip. dent. (Print) ; 15(1): 97-99, abr. 2022. ilus
Artigo em Inglês | LILACS | ID: biblio-1385259

RESUMO

ABSTRACT: Nowadays, maxillary midline diastema (MMD) can be treated with different multidisciplinary approaches. When restorative dentistry is needed, glass-matrix ceramic materials is one of the best choices, since they present good optical behavior and high survival rates in the anterior dentition. To obtain an adequate interphase, and color integration are one of the main restorative goals, and for that purpose, specific finishing and polishing procedures must be employed to avoid staining and ensure the restoration's color stability. In the case report presented in this article, a single lithium disilicate ceramic fragment was performed to close a MMD produced by the shape alteration of one of the maxillary central incisors. Also, the finishing and polishing procedure is discussed.


Assuntos
Humanos , Feminino , Adulto , Cerâmica , Cor , Odontologia , Diastema
12.
J Esthet Restor Dent ; 34(5): 804-815, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35187786

RESUMO

OBJECTIVES: To characterize the mechanical and biological properties of three commercially available resins, which are currently used for provisional restorations and to compare them to an experimental resin intended for definitive fixed dental prostheses. MATERIALS AND METHODS: Three commercially available resins: Crowntec (CT, Saremco), Temporary C&B (FL, Formlabs), C&B MFH (ND, Nextdent), and the experimental resin: Permanent Bridge (PB, Saremco) were printed and subjected to biaxial flexural strength test, finite element analysis, Weibull analysis, scanning electron microscopy, cell proliferation, immunohistochemistry and cytotoxicity assays. Samples from CT, PB, and ND were provided directly from the manufacturers ensuring ideal workflow. FL was printed using the workflow as recommended by the manufacturer, using a Formlabs 2 printer and their post-processing units Form Wash and Form Cure. RESULTS: From the tested resins, PB yielded the best overall results in terms of mechanical properties. Cell proliferation and cytotoxicity did not show any significant differences among materials. PB showed higher values for probability of survival predictions (35%) when subjected to 250 MPa loads, whereas the other materials did not reach 10%. SIGNIFICANCE: Despite mechanical differences between the evaluated materials, the outcomes suggest that 3D printed provisional resins may be used in clinical settings, following the manufacturers indications. New materials intended for long-term use, such as the PB resin, yielded higher mechanical properties compared to the other materials. Alternative printing and post-processing methods have not yet been evaluated and should be avoided until further literature is available. CLINICAL SIGNIFICANCE: 3D printed resins for provisional restorations have become popular with the emergence of new technologies. In this study, we evaluated three different commercially available resins for provisional restorations and one new experimental resin. The results from this study indicate that commercially available resins could be used in clinical settings under certain conditions and limited periods of time. Following the manufacturers protocols is of paramount importance to not compromise these properties.


Assuntos
Resinas Compostas , Resistência à Flexão , Teste de Materiais , Impressão Tridimensional , Propriedades de Superfície
13.
Rev Bras Ter Intensiva ; 34(4): 418-425, 2022.
Artigo em Português, Inglês | MEDLINE | ID: mdl-36888821

RESUMO

OBJECTIVE: To describe the IMPACTO-MR, a Brazilian nationwide intensive care unit platform study focused on the impact of health care-associated infections due to multidrug-resistant bacteria. METHODS: We described the IMPACTO-MR platform, its development, criteria for intensive care unit selection, characterization of core data collection, objectives, and future research projects to be held within the platform. RESULTS: The core data were collected using the Epimed Monitor System® and consisted of demographic data, comorbidity data, functional status, clinical scores, admission diagnosis and secondary diagnoses, laboratory, clinical, and microbiological data, and organ support during intensive care unit stay, among others. From October 2019 to December 2020, 33,983 patients from 51 intensive care units were included in the core database. CONCLUSION: The IMPACTO-MR platform is a nationwide Brazilian intensive care unit clinical database focused on researching the impact of health care-associated infections due to multidrug-resistant bacteria. This platform provides data for individual intensive care unit development and research and multicenter observational and prospective trials.


OBJETIVO: Descrever o IMPACTO-MR, um estudo brasileiro de plataforma nacional em unidades de terapia intensiva focado no impacto das infecções por bactérias multirresistentes relacionadas à assistência à saúde. MÉTODOS: Descrevemos a plataforma IMPACTO-MR, seu desenvolvimento, critérios para seleção das unidades de terapia intensiva, caracterização da coleta de dados, objetivos e projetos de pesquisa futuros a serem realizados na plataforma. RESULTADOS: Os dados principais foram coletados por meio do Epimed Monitor System® e consistiram em dados demográficos, dados de comorbidades, estado funcional, escores clínicos, diagnóstico de internação e diagnósticos secundários, dados laboratoriais, clínicos e microbiológicos e suporte de órgãos durante a internação na unidade de terapia intensiva, entre outros. De outubro de 2019 a dezembro de 2020, 33.983 pacientes de 51 unidades de terapia intensiva foram incluídos no banco de dados principal. CONCLUSÃO: A plataforma IMPACTO-MR é um banco de dados clínico brasileiro de unidades de terapia intensiva focado na pesquisa do impacto das infecções por bactérias multirresistentes relacionadas à assistência à saúde. Essa plataforma fornece dados para o desenvolvimento e pesquisa de unidades de terapia intensiva individuais e ensaios clínicos observacionais e prospectivos multicêntricos.


Assuntos
Infecção Hospitalar , Unidades de Terapia Intensiva , Humanos , Estudos Prospectivos , Brasil , Infecção Hospitalar/epidemiologia , Farmacorresistência Bacteriana Múltipla
14.
Cranio ; 40(4): 373-380, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32114958

RESUMO

Objective: To compare maximum incisor (MBFinc) and molar (MBFmol) bite forces regarding the type of dentition and sex and to establish a relationship between them.Methods: One hundred-five individuals were divided into 3 groups: G1 - 22 females/13 males (4-5 years); G2 - 15 females/20 males (11-12 years); and G3 - 16 females/19 males (17- 18 years). The maximum bite force was recorded with an extraoral measuring device. Three measurements were recorded: right and left molar level (MBFmol) and incisor level (MBFinc). The ratio %MBFinc/MBFmol was determined.Results: MBFmol and MBFinc values increased with age (p < 0.05). MBFmol showed statistically higher values than MBFinc (p < 0.05), when compared within the same group.Conclusion: MBFinc and MBFmol increased with age. For all groups, MBFmol showed higher values than MBFinc, and %MBFinc/MBFmol ratio was 1:2. No differences were found in maximum bite force between sexes.


Assuntos
Força de Mordida , Incisivo , Dentição , Feminino , Humanos , Masculino , Dente Molar
15.
J Prosthet Dent ; 128(4): 784-792, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33741142

RESUMO

STATEMENT OF PROBLEM: The light source stability of digital cameras and smartphones is important in shade matching in restorative and prosthetic dentistry to communicate objectively with the dental laboratory. Techniques that standardize the light source of such devices are lacking, and this limitation can lead to color mismatches, difficulties in color communication, and treatment documentation. PURPOSE: The purpose of this clinical study was to compare the magnitude of color difference (ΔE) among 3 shade selection methods during the fabrication of ceramic crowns: visual shade selection with a shade guide, digital shade selection with a digital camera and cross-polarizing filter, and digital shade selection with a smartphone and a light-correcting device. MATERIAL AND METHODS: Forty-five patients in need of ceramic crowns were enrolled, and shade selection was evaluated according to different protocols: visual shade selection (A-D shade guide and IPS Natural Die Material Shade Guide, sent to the dental laboratory technician via a laboratory prescription); digital shade selection with a digital camera (D7000; Nikon Corp) with an 85-mm lens and wireless close-up flash, with and without a cross-polarizing filter (Polar eyes); and digital shade selection with a smartphone and a light-correcting device (iPhone XS attached to Smile Lite MDP, with and without its cross-polarizing filter accessory). Information from the smartphone was imported to an app (IPS e.max Shade Navigation App; Ivoclar AG) that converted the reading to a shade and level of translucency for the ceramic restoration. For all photographs, a gray reference card with known color values was positioned by the mandibular teeth and was used for white balancing of the digital photographs with a software program. All photographs were edited and sent to the dental laboratory: white-balanced with the shade guide; white-balanced with the substrate shade guide; black and white; saturated; and cross-polarized. Ceramic crowns were made with the same lithium disilicate material (IPS e.max CAD; Ivoclar AG) and cemented with the same resin cement (RelyX Ultimate Clicker, A3 shade; 3M). The ΔE values between the crown and the adjacent tooth were determined. The data were analyzed by using a 1-way analysis of variance (ANOVA) and Tukey post hoc tests (α=.05). RESULTS: The mean ΔE between a cemented ceramic crown and the adjacent tooth in the visual shade selection group was 5.32, significantly different than both digital camera (ΔE=2.75; P=.002) and smartphone (ΔE=2.34; P=.001), which were not different from each other (P=.857). CONCLUSIONS: The digital shade selection with photographs acquired with both a digital camera and a smartphone with a light-correcting device showed a threshold within the acceptable values (ΔE<3.7), whereas the visual shade selection showed an average ΔE above the threshold for acceptable values (ΔE>3.7). The use of a gray reference card helped standardize the white balance from the digital images.


Assuntos
Porcelana Dentária , Smartphone , Humanos , Cor , Coroas , Cimentos de Resina , Cerâmica
16.
J Esthet Restor Dent ; 34(1): 7-14, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34792281

RESUMO

The increased emphasis on orofacial esthetics, experienced both by dental professionals and the lay public, results in an environment where overtreatment can easily occur. Patients on the one hand feel pressure from esthetic norms that are often unrealistic, while dental professionals are compelled to deliver immediate results many times without considering what is best for the ill-informed patient. This article is an illustrated cautionary tale against overtreatment disguised as esthetic dentistry. Representative clinical examples illustrate how porcelain veneers are used without following sound operatory principles, as well as how these cases have been resolved.


Assuntos
Facetas Dentárias , Sobretratamento , Cerâmica , Porcelana Dentária , Estética Dentária , Humanos
17.
Adv Rheumatol ; 61(1): 60, 2021 10 07.
Artigo em Inglês | MEDLINE | ID: mdl-34620246

RESUMO

BACKGROUND: There is a lack of information on the role of chronic use of hydroxychloroquine during the SARS-CoV-2 outbreak. Our aim was to compare the occurrence of COVID-19 between rheumatic disease patients on hydroxychloroquine with individuals from the same household not taking the drug during the first 8 weeks of community viral transmission in Brazil. METHODS: This baseline cross-sectional analysis is part of a 24-week observational multi-center study involving 22 Brazilian academic outpatient centers. All information regarding COVID-19 symptoms, epidemiological, clinical, and demographic data were recorded on a specific web-based platform using telephone calls from physicians and medical students. COVID-19 was defined according to the Brazilian Ministry of Health (BMH) criteria. Mann-Whitney, Chi-square and Exact Fisher tests were used for statistical analysis and two binary Final Logistic Regression Model by Wald test were developed using a backward-stepwise method for the presence of COVID-19. RESULTS: From March 29th to May 17st, 2020, a total of 10,443 participants were enrolled, including 5166 (53.9%) rheumatic disease patients, of whom 82.5% had systemic erythematosus lupus, 7.8% rheumatoid arthritis, 3.7% Sjögren's syndrome and 0.8% systemic sclerosis. In total, 1822 (19.1%) participants reported flu symptoms within the 30 days prior to enrollment, of which 3.1% fulfilled the BMH criteria, but with no significant difference between rheumatic disease patients (4.03%) and controls (3.25%). After adjustments for multiple confounders, the main risk factor significantly associated with a COVID-19 diagnosis was lung disease (OR 1.63; 95% CI 1.03-2.58); and for rheumatic disease patients were diagnosis of systemic sclerosis (OR 2.8; 95% CI 1.19-6.63) and glucocorticoids above 10 mg/ day (OR 2.05; 95% CI 1.31-3.19). In addition, a recent influenza vaccination had a protective effect (OR 0.674; 95% CI 0.46-0.98). CONCLUSION: Patients with rheumatic disease on hydroxychloroquine presented a similar occurrence of COVID-19 to household cohabitants, suggesting a lack of any protective role against SARS-CoV-2 infection. Trial registration Brazilian Registry of Clinical Trials (ReBEC; RBR - 9KTWX6).


Assuntos
Antirreumáticos/uso terapêutico , COVID-19/prevenção & controle , Doenças Reumáticas/tratamento farmacológico , Adulto , Idoso , Idoso de 80 Anos ou mais , Artrite Reumatoide/tratamento farmacológico , Brasil/epidemiologia , COVID-19/epidemiologia , Distribuição de Qui-Quadrado , Estudos de Coortes , Estudos Transversais , Saúde da Família/estatística & dados numéricos , Feminino , Humanos , Hidroxicloroquina/uso terapêutico , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Escleroderma Sistêmico/tratamento farmacológico , Síndrome de Sjogren/tratamento farmacológico , Estatísticas não Paramétricas , Adulto Jovem
18.
Quintessence Int ; 52(10): 904-910, 2021 Oct 19.
Artigo em Inglês | MEDLINE | ID: mdl-34410071

RESUMO

OBJECTIVE: To evaluate, in vivo, trueness and precision of two intraoral scanners, CEREC Omnicam (OMNI) and CEREC Primescan (PRIM), compared to a conventional impression serving as a master model. METHOD AND MATERIALS: Impressions were performed for seven participants. For each participant, conventional polyvinylsiloxane impression and digital impressions using two intraoral scanners, OMNI (software 4.6; CEREC ORTHO Protocol) and PRIM (10 digital impressions per participant, per scanner), were made. Conventional impression was digitized with a laboratory scanner (INEOS X5), and used as reference model. .STL files were superimposed with software (Geomagic Control X) using the tools Initial Alignment and Best Fit Alignment, and trueness and precision were evaluated. Statistical evaluation was performed with Shapiro-Wilk and Mann-Whitney tests (P < .05). RESULTS: Total mean trueness for the OMNI system was 56.45 ± 7.80 µm, and 47.29 ± 5.47 µm for the PRIM system. Regarding precision, values from the OMNI system were 42.47 ± 6.91 µm and from the PRIM system 21.86 ± 4.40 µm. PRIM presented better results for both trueness (P = .000) and precision (P = .000) when compared to OMNI. CONCLUSIONS: PRIM provided a better combination of trueness and precision than its predecessor OMNI. However, both PRIM and OMNI performed acceptably when performing indirect restorations, according to the current acceptable thresholds, considering both trueness and precision. CLINICAL IMPLICATIONS: Full-arch impressions with Primescan presented more precision and trueness than Omnicam; however, compared to previous reported values of conventional impressions, they still presented lower accuracy.


Assuntos
Técnica de Moldagem Odontológica , Modelos Dentários , Desenho Assistido por Computador , Arco Dental , Humanos , Imageamento Tridimensional
19.
Int J Comput Dent ; 24(2): 181-194, 2021 Jun 04.
Artigo em Inglês | MEDLINE | ID: mdl-34085503

RESUMO

AIM: The present clinical case reports on the workflow of a multidisciplinary treatment including both orthodontic and esthetic procedures for the rehabilitation of a young patient with severe wear in the anterior area of both the maxillary and mandibular arches due to malocclusion. The described workflow comprises a digital step-by-step process that involves 3D printing, intraoral scanners, and CAD/CAM milling systems. RESULTS: Accurate diagnostic and treatment planning were paramount when different specialties needed to combine and work together. For that purpose, different digital procedures helped to improve the predictability and the dynamic of the orthodontic and restorative treatments. CONCLUSION: The present multidisciplinary clinical case was executed with a digital approach that assisted to speed things up and achieve a predictable treatment option.


Assuntos
Facetas Dentárias , Dente , Desenho Assistido por Computador , Estética Dentária , Humanos , Maxila
20.
J Esthet Restor Dent ; 33(7): 1038-1044, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34060216

RESUMO

OBJECTIVE: To evaluate color differences (ΔE) of different fabrication steps performed on a feldspathic ceramic and relative translucency parameter (RTP) after glazing; and to evaluate their effects on the color parameters: L*, a* and b*. MATERIAL AND METHODS: Computer-aided design/computer-aided manufacturing (CAD-CAM) feldspathic maxillary right central incisor ceramic crowns (Cerec Blocs; 1.4 mm thickness) were fabricated through scanning a model preparation and milling. A total of 20 specimens were used and different parameters were compared with each other for color difference (ΔE): original block, milling, polishing, glazing and try-in cements; RTP was measured after glazing. Color parameters (L*, a*, and b*) were evaluated after each step with a spectrophotometer (Vita Easyshade V) and compared using the CIEDE2000 formula. Statistical analyses were done using one-way ANOVA and post-hoc tests. RESULTS: The highest ΔE value was observed for Original versus Milling group (4.73) and the lowest for Polishing versus Glazing (0.49). RTP after glazing presented a value of 12.01. L*, a*, and b* parameters were different among groups. Milling group was the one that presented more differences compared to the Original block regarding L*, a*, and b* parameters. CONCLUSIONS: Different fabrication steps resulted in perceptible color differences within themselves, and L*, a*, and b* parameters changed according to each step. All milling specimens presented unacceptable color differences when compared to the other steps, and milling specimens showed all color parameters (L*, a*, and b*) statistically different compared to the Original block. A high RTP value was observed, demonstrating that, at 1.4 mm thickness, the feldspathic ceramic presented high translucency, showing that opacification of substrate might be necessary. CLINICAL SIGNIFICANCE: Different fabrication steps can greatly affect the optical properties of the feldspathic ceramic restoration studied and cause a relevant impact when compared to the ceramic block itself. Crowns evaluated right after milling presented the highest color differences. In order to obtain optical properties as close as possible to the original feldspathic ceramic block, either polishing or polishing and glazing needs to be performed.


Assuntos
Cerâmica , Porcelana Dentária , Cor , Desenho Assistido por Computador , Teste de Materiais , Propriedades de Superfície
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...