Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
1.
Radiother Oncol ; 196: 110284, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38636711

RESUMO

INTRODUCTION: Treatment planning using a five-millimetre geometrical margin from GTV to high-dose CTV (CTV1) has been used in DAHANCA treatment centres since 2013. We aimed to evaluate changes in CTV1 volumes, local control (LC), and recurrence pattern after the implementation of five-millimetre geometrical margins nationally. MATERIALS AND METHODS: 1,948 patients with pharyngeal, and laryngeal squamous cell carcinomas completed definitive IMRT-based treatment in 2010-2012 and 2013-2015 in three centres. The patient-specific margin was calculated as median surface distance from primary tumour GTV (GTV-T) to CTV1. Radiologically verified local recurrences were analysed using a centre of mass (COM) of the delineated recurrence volume, measuring the shortest distance between COM to GTV-T and CTV1 boundaries. RESULTS: Median GTV-CTV1 was 0.9 (0.0-0.97) and 0.47 cm (0.4-0.5) for 2010-2012 and 2013-2015, respectively. Median CTV1 changed in three centres from 76, 28, 42 cm3 to 61, 53, 62 cm3 for 2010-2012 and 2013-2015, respectively. Local failures occurred at 247 patients during first three years after radiotherapy. The 3-year LC rate for 2010-2012 and 2013-2015 was 0.84 and 0.87 (p = 0.06). Out of 146 radiology-verified analysable local recurrences, 102 (69.9%) were inside the CTV1. In 74.6% and 91% of cases, the LRs were covered by 95% isodose in 2010-2012 and 2013-2015, respectively. CONCLUSION: DAHANCA radiotherapy guidelines based on a geometrically generated isotropic CTV1 margin led to less variation in treatment volumes and between centres than previous guidelines. The transition towards consensus GTV-CTV1 margins did not influence local tumour control. The majority of local recurrences were inside CTV1 and covered by the prescription dose.


Assuntos
Neoplasias Laríngeas , Recidiva Local de Neoplasia , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada , Humanos , Masculino , Feminino , Recidiva Local de Neoplasia/radioterapia , Pessoa de Meia-Idade , Idoso , Planejamento da Radioterapia Assistida por Computador/métodos , Neoplasias Laríngeas/radioterapia , Neoplasias Laríngeas/patologia , Radioterapia de Intensidade Modulada/métodos , Guias de Prática Clínica como Assunto , Neoplasias Faríngeas/radioterapia , Neoplasias Faríngeas/patologia , Carcinoma de Células Escamosas/radioterapia , Carcinoma de Células Escamosas/patologia , Idoso de 80 Anos ou mais , Adulto
2.
Clin Transl Radiat Oncol ; 46: 100772, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38596816

RESUMO

Introduction: Patients with failure after primary radiotherapy (RT) for head and neck squamous cell carcinoma (HNSCC) have a poor prognosis. This study investigates pattern of failure after primary curatively intended IMRT in a randomized controlled trial in relation to HPV/p16 status. Material and methods: Patients with HNSCC of the oral cavity, oropharynx (OPSCC), hypopharynx or larynx were treated with primary curative IMRT (+/-cisplatin) and concomitant nimorazole between 2007 and 12. Of 608 patients, 151 had loco-regional failure within five years, from whom 130 pairs of scans (planning-CT and diagnostic failure scan) were collected and deformably co-registered. Point of origin-based pattern of failure analysis was conducted, including distance to CTV1 and GTV, and estimated dose coverage of the point of origin. Results: Of 130 patients with pairs of scans, 104 (80 %) had at least one local or regional failure site covered by 95 % of prescribed dose and 87 (67 %) of the failures had point of origin within the high-dose CTV (CTV1). Of failures from primary p16 + OPSCC, the majority of both mucosal (84 %) and nodal (61 %) failures were covered by curative doses. For p16- tumors (oral cavity, OPSCC p16neg, hypopharynx and larynx), 75 % of mucosal and 66 % of nodal failures were high-dose failures. Conclusion: Radioresistance is the primary cause of failure after RT for HNSCC irrespective of HPV/p16 status. Thus, focus on predictors for the response to RT is warranted to identify patients with higher risk of high-dose failure that might benefit from intensified treatment regimens.

3.
Radiother Oncol ; 193: 110149, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38341096

RESUMO

BACKGROUND AND PURPOSE: Reliable and accessible biomarkers for patients with Head and Neck Squamous Cell Carcinoma (HNSCC) are warranted for biologically driven radiotherapy (RT). This study aimed to investigate the prognostic value of putative cancer stem cell (CSC) markers, hypoxia, and tumor volume using loco-regional high-dose failure (HDF) as endpoint. MATERIALS AND METHODS: Tumor tissue was retrieved from patients treated with primary chemo-(C-)RT and nimorazole for HNSCC in the Danish Head and Neck Cancer Study Group (DAHANCA) 19 study. Tumor volume, hypoxic classification, and expression of CSC markers CD44, SLC3A2, and MET were analyzed. For patients with eligible data on all parameters (n = 340), the risk of HDF following primary chemo-(C-)RT were analyzed by these biomarkers as a whole and stratified for p16-positive oropharynx (p16 + OPSCC) vs p16-negative (p16-) tumors (oral cavity, p16- oropharynx, hypopharynx and larynx). RESULTS: Higher risk of HDF was seen for patients with larger primary and nodal volume (>25 cm3, Hazard Ratio (HR): 3.00 [95 % CI: 1.73-5.18]), high SLC3A2 (HR: 2.99 [1.28-6.99]), CD44 (>30 % positive, HR: 2.29 [1.05-5.00]), and p16- tumors (HR: 2.53 [1.05-6.11]). p16- tumors had a higher CSC marker expression than p16 + OPSCC. The factors associated with the highest risk of HDF were larger volume (HR: 3.29 [1.79-6.04]) for p16- tumors (n = 178) and high SLC3A2 (HR: 6.19 [1.58-24.23]) for p16 + OPSCC (n = 162). CONCLUSION: Tumor volume, p16, and CSC markers are potential biomarkers for HDF for patients with HNSCC treated with (C-)RT. Lower expression of CSC in p16 + OPSCC may contribute to better tumor control.


Assuntos
Carcinoma de Células Escamosas , Neoplasias de Cabeça e Pescoço , Infecções por Papillomavirus , Humanos , Carcinoma de Células Escamosas de Cabeça e Pescoço/metabolismo , Prognóstico , Carcinoma de Células Escamosas/radioterapia , Carga Tumoral , Neoplasias de Cabeça e Pescoço/metabolismo , Hipóxia/metabolismo , Biomarcadores , Células-Tronco Neoplásicas/patologia , Infecções por Papillomavirus/metabolismo , Inibidor p16 de Quinase Dependente de Ciclina , Biomarcadores Tumorais/metabolismo
4.
Radiother Oncol ; 190: 109812, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37479061

RESUMO

INTRODUCTION: Proton treatment can potentially spare patients with H&N cancer for substantial treatment-related toxicities. The current study investigated the reproducibility of a decentralised model-based selection of patients for a proton treatment study when the selection plans were compared to the clinical treatment plans performed at the proton centre. METHODS: Sixty-three patients were selected for proton treatment in the six Danish Head and Neck Cancer (DAHANCA) centres. The patients were selected based on normal tissue complication probability (NTCP) estimated from local photon and proton treatment plans, which showed a ΔNTCP greater than 5%-point for either grade 2 + dysphagia or grade 2 + xerostomia at six months. The selection plans were compared to the clinical treatment plans performed at the proton centre. RESULTS: Of the 63 patients, 49 and 25 were selected based on an estimated benefit in risk of dysphagia and xerostomia, respectively. Eleven patients had a potential gain in both toxicities. The mean ΔNTCP changed from the local selection plan comparison to the clinical comparison from 6.9 to 5.3 %-points (p = 0.01) and 7.3 to 4.9 %-points (p = 0.03) for dysphagia and xerostomia, respectively. Volume differences in both CTV and OAR could add to the loss in ΔNTCP. 61 of the 63 clinical plans had a positive ΔNTCP, and 38 had a ΔNTCP of 5%-points for at least one of the two endpoints. CONCLUSION: A local treatment plan comparison can be used to select candidates for proton treatment. The local comparative proton plan overestimates the potential benefit of the clinical proton plan. Continuous quality assurance of the delineation procedures and planning is crucial in the subsequent randomised clinical trial setting.


Assuntos
Transtornos de Deglutição , Neoplasias de Cabeça e Pescoço , Terapia com Prótons , Radioterapia de Intensidade Modulada , Xerostomia , Humanos , Prótons , Órgãos em Risco , Transtornos de Deglutição/etiologia , Reprodutibilidade dos Testes , Dosagem Radioterapêutica , Terapia com Prótons/efeitos adversos , Terapia com Prótons/métodos , Neoplasias de Cabeça e Pescoço/radioterapia , Neoplasias de Cabeça e Pescoço/etiologia , Xerostomia/etiologia , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos
5.
Acta Oncol ; 62(11): 1551-1560, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37815867

RESUMO

BACKGROUND: As magnetic resonance imaging (MRI) becomes increasingly integrated into radiotherapy (RT) for enhanced treatment planning and adaptation, the inherent geometric distortion in acquired MR images pose a potential challenge to treatment accuracy. This study aimed to evaluate the geometric distortion levels in the clinical MRI protocols used across Danish RT centers and discuss influence of specific sequence parameters. Based on the variety in geometric performance across centers, we assess if harmonization of MRI sequences is a relevant measure. MATERIALS AND METHODS: Nine centers participated with 12 MRI scanners and MRI-Linacs (MRL). Using a travelling phantom approach, a reference MRI sequence was used to assess variation in baseline distortion level between scanners. The phantom was also scanned with local clinical MRI sequences for brain, head/neck (H/N), abdomen, and pelvis. The influence of echo time, receiver bandwidth, image weighting, and 2D/3D acquisition was investigated. RESULTS: We found a large variation in geometric accuracy across 93 clinical sequences examined, exceeding the baseline variation found between MRI scanners (σ = 0.22 mm), except for abdominal sequences where the variation was lower. Brain and abdominal sequences showed lowest distortion levels ([0.22, 2.26] mm), and a large variation in performance was found for H/N and pelvic sequences ([0.19, 4.07] mm). Post hoc analyses revealed that distortion levels decreased with increasing bandwidth and a less clear increase in distortion levels with increasing echo time. 3D MRI sequences had lower distortion levels than 2D (median of 1.10 and 2.10 mm, respectively), and in DWI sequences, the echo-planar imaging read-out resulted in highest distortion levels. CONCLUSION: There is a large variation in the geometric distortion levels of clinical MRI sequences across Danish RT centers, and between anatomical sites. The large variation observed makes harmonization of MRI sequences across institutions and adoption of practices from well-performing anatomical sites, a relevant measure within RT.


Assuntos
Imagem Ecoplanar , Imageamento por Ressonância Magnética , Humanos , Imageamento por Ressonância Magnética/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Encéfalo , Imagens de Fantasmas
6.
Acta Oncol ; 62(10): 1161-1168, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37850659

RESUMO

BACKGROUND: Previously, many radiotherapy (RT) trials were based on a few selected dose measures. Many research questions, however, rely on access to the complete dose information. To support such access, a national RT plan database was created. The system focuses on data security, ease of use, and re-use of data. This article reports on the development and structure, and the functionality and experience of this national database. METHODS AND MATERIALS: A system based on the DICOM-RT standard, DcmCollab, was implemented with direct connections to all Danish RT centres. Data is segregated into any number of collaboration projects. User access to the system is provided through a web interface. The database has a finely defined access permission model to support legal requirements. RESULTS: Currently, data for more than 14,000 patients have been submitted to the system, and more than 50 research projects are registered. The system is used for data collection, trial quality assurance, and audit data set generation.Users reported that the process of submitting data, waiting for it to be processed, and then manually attaching it to a project was resource intensive. This was accommodated with the introduction of triggering features, eliminating much of the need for users to manage data manually. Many other features, including structure name mapping, RT plan viewer, and the Audit Tool were developed based on user input. CONCLUSION: The DcmCollab system has provided an efficient means to collect and access complete datasets for multi-centre RT research. This stands in contrast with previous methods of collecting RT data in multi-centre settings, where only singular data points were manually reported. To accommodate the evolving legal environment, DcmCollab has been defined as a 'data processor', meaning that it is a tool for other research projects to use rather than a research project in and of itself.


Assuntos
Radioterapia (Especialidade) , Radioterapia , Humanos , Ensaios Clínicos como Assunto
7.
Acta Oncol ; 62(11): 1418-1425, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37703300

RESUMO

BACKGROUND: In the Danish Head and Neck Cancer Group (DAHANCA) 35 trial, patients are selected for proton treatment based on simulated reductions of Normal Tissue Complication Probability (NTCP) for proton compared to photon treatment at the referring departments. After inclusion in the trial, immobilization, scanning, contouring and planning are repeated at the national proton centre. The new contours could result in reduced expected NTCP gain of the proton plan, resulting in a loss of validity in the selection process. The present study evaluates if contour consistency can be improved by having access to AI (Artificial Intelligence) based contours. MATERIALS AND METHODS: The 63 patients in the DAHANCA 35 pilot trial had a CT from the local DAHANCA centre and one from the proton centre. A nationally validated convolutional neural network, based on nnU-Net, was used to contour OARs on both scans for each patient. Using deformable image registration, local AI and oncologist contours were transferred to the proton centre scans for comparison. Consistency was calculated with the Dice Similarity Coefficient (DSC) and Mean Surface Distance (MSD), comparing contours from AI to AI and oncologist to oncologist, respectively. Two NTCP models were applied to calculate NTCP for xerostomia and dysphagia. RESULTS: The AI contours showed significantly better consistency than the contours by oncologists. The median and interquartile range of DSC was 0.85 [0.78 - 0.90] and 0.68 [0.51 - 0.80] for AI and oncologist contours, respectively. The median and interquartile range of MSD was 0.9 mm [0.7 - 1.1] mm and 1.9 mm [1.5 - 2.6] mm for AI and oncologist contours, respectively. There was no significant difference in ΔNTCP. CONCLUSIONS: The study showed that OAR contours made by the AI algorithm were more consistent than those made by oncologists. No significant impact on the ΔNTCP calculations could be discerned.


Assuntos
Inteligência Artificial , Neoplasias de Cabeça e Pescoço , Humanos , Órgãos em Risco , Prótons , Planejamento da Radioterapia Assistida por Computador/métodos
8.
Phys Imaging Radiat Oncol ; 23: 80-84, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35844257

RESUMO

MRI (magnetic resonance imaging) scans are frequently used in follow-up after radiotherapy for head and neck cancer. With the overall aim of enabling MRI-based pattern of failure analysis, this study evaluated the accuracy of recurrence MRI (rMRI) deformable co-registration with planning CT (computed tomography)-scans (pCT). Uncertainty of anatomical changes between pCT and rMRI was assessed by similarity metric analyses of co-registered image structures from 19 patients. Average mean distance to agreement and Dice similarity coefficient performed adequately. Our findings provide proof of concept for reliable co-registration of pCT and rMRI months to years apart for MRI-based pattern of failure analysis.

9.
Acta Oncol ; 61(2): 120-126, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34979878

RESUMO

PURPOSE: The study aimed to investigate the pattern of failure and describe compromises in the definition and coverage of the target for patients treated with curatively intended radiotherapy (RT) for sinonasal cancer (SNC). METHODS AND MATERIAL: Patients treated with curatively intended RT in 2008-2015 in Denmark for SNC were eligible for the retrospective cohort study. Information regarding diagnosis and treatment was retrieved from the national database of the Danish Head and Neck Cancer Group (DAHANCA). Imaging from the diagnosis of recurrences was collected, and the point of origin (PO) of the recurrent tumour was estimated. All treatment plans were collected and reviewed with the focus on target coverage, manual modifications of target volumes, and dose to organs at risk (OARs) above defined constraints. RESULTS: A total of 184 patients were included in the analysis, and 76 (41%) relapsed. The majority of recurrences involved T-site (76%). Recurrence imaging of 39 patients was evaluated, and PO was established. Twenty-nine POs (74%) were located within the CTV, and the minimum dose to the PO was median 64.1 Gy (3.1-70.7). The criteria for target coverage (V95%) was not met in 89/184 (48%) of the CTV and 131/184 (71%) of the PTV. A total of 24% of CTVs had been manually modified to spare OARs of high-dose irradiation. No difference in target volume modifications was observed between patients who suffered recurrence and patients with lasting remission. CONCLUSION: The majority of relapses after radical treatment of SNC were located in the T-site (the primary tumour site). Multiple compromises with regards to target coverage and tolerance levels for OARs in the sinonasal region, as defined from RT guidelines, were taken. No common practice in this respect could be derived from the study.


Assuntos
Neoplasias dos Seios Paranasais , Radioterapia Conformacional , Radioterapia de Intensidade Modulada , Dinamarca/epidemiologia , Humanos , Recidiva Local de Neoplasia/epidemiologia , Recidiva Local de Neoplasia/radioterapia , Neoplasias dos Seios Paranasais/radioterapia , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Estudos Retrospectivos
11.
Radiother Oncol ; 126(1): 43-47, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-28987748

RESUMO

BACKGROUND AND PURPOSE: Defining margins around the Gross Tumour Volume (GTV) to create a Clinical Target Volume (CTV) for head and neck cancer radiotherapy has traditionally been based on presumed knowledge of anatomical routes of spread. However, using a concentric geometric expansion around the GTV may be more reproducible. The purpose of this study was to analyse the inter-observer consistency of geometric CTV delineation with adaptation for anatomical boundaries versus anatomically defined CTVs. MATERIAL AND METHODS: Radiation oncologists at four Danish cancer centres delineated high, intermediate and elective dose CTVs (CTV1, CTV2 and CTV3, respectively) in a patient-case template (stage IV squamous cell carcinoma of the oropharynx), first using mainly anatomical margins (original standard) and then using concentric geometric expansion (new standard). Each centre made a dummy-run radiotherapy plan based on the delineated CTVs. The difference between the CTV contours and the radiotherapy plans was evaluated across the centres. RESULTS: Anatomy-based contours were significantly more heterogenous and showed larger volume differences between centres than geometric margins. Dice similarity coefficient increased by 0.29 and mean surface distance decreased by 4mm for CTV1. Use of consistent CTV volumes resulted in more consistent irradiated volumes between centres. CONCLUSION: Introduction of geometric margins resulted in more uniform CTV1 and CTV2 delineation. Geometric CTV expansion was easier, left less room for misinterpretation, and resulted in more uniform treatment plans with similar irradiated high and intermediate dose volumes across all centres.


Assuntos
Carcinoma de Células Escamosas/radioterapia , Neoplasias de Cabeça e Pescoço/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Carcinoma de Células Escamosas/patologia , Relação Dose-Resposta à Radiação , Neoplasias de Cabeça e Pescoço/patologia , Humanos , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Neoplasias Orofaríngeas/patologia , Neoplasias Orofaríngeas/radioterapia , Carcinoma de Células Escamosas de Cabeça e Pescoço
12.
Radiother Oncol ; 126(1): 48-55, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-29248171

RESUMO

INTRODUCTION: The aim was to analyze position of CT-verified local recurrences (LR) and local control (LC) among three centers that used different GTV to CTV1 margins. MATERIALS AND METHODS: In total, 1576 patients completing radical primary IMRT for larynx, pharynx, oral cavity HNSCC in three centers in Denmark between 2006 and 2012 were included. CT-verified LRs were analyzed as possible points of recurrence origin and compared between groups of small (0-2.5 mm), larger (>2.5 mm), and anatomical GTV-CTV1 margins. The recurrence point's position relative to the GTV and 95% prescription dose was evaluated. Overall local control rate was evaluated using Cox uni- and multi-variate analysis. RESULTS: After a median follow-up of 41 months, 272 patients had local failure. Median GTV-CTV1 margin in Center1, 2 and 3 was 0.0, 3.7 and 9.7 mm, respectively. 51% of local recurrences were inside the GTV. No difference in distribution of LRs in relation to GTV surface (p = 0.4) or the dose to LRs (p = 0.2) was detected between the groups. A difference in LC was found univariate between the centers (p = 0.03), but not in multivariate analysis (p = 0.4). CONCLUSIONS: No relation was found between the recurrences' distributions as function of the margins used at three centers. In multivariate analysis, local control was not influenced by the centers.


Assuntos
Carcinoma de Células Escamosas/radioterapia , Neoplasias de Cabeça e Pescoço/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Carcinoma de Células Escamosas/patologia , Relação Dose-Resposta à Radiação , Feminino , Neoplasias de Cabeça e Pescoço/patologia , Humanos , Masculino , Recidiva Local de Neoplasia/patologia , Estadiamento de Neoplasias , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/métodos , Carcinoma de Células Escamosas de Cabeça e Pescoço
14.
Med Phys ; 38(9): 5146-66, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21978060

RESUMO

PURPOSE: With the increased commercial availability of intensity modulated arc therapy (IMAT) comes the need for comprehensive QA programs, covering the different aspects of this newly available technology. This manuscript proposes such a program for the RapidArc (RA) (Varian Medical Systems, Palo Alto) IMAT solution. METHODS: The program was developed and tested out for a Millennium120 MLC on iX Clinacs and a HighDefinition MLC on a Novalis TX, using a variety of measurement equipment including Gafchromic film, 2D ion chamber arrays (Seven29 and StarCheck, PTW, Freiburg, Germany) with inclinometer and Octavius phantom, the Delta4 systam (ScandiDos, Uppsala, Sweden) and the portal imager (EPID). First, a number of complementary machine QA tests were developed to monitor the correct interplay between the accelerating/decelerating gantry, the variable dose rate and the MLC position, straining the delivery to the maximum allowed limits. Second, a systematic approach to the validation of the dose calculation for RA was adopted, starting with static gantry and RA specific static MLC shapes and gradually moving to dynamic gantry, dynamic MLC shapes. RA plans were then optimized on a series of artificial structures created within the homogeneous Octavius phantom and within a heterogeneous lung phantom. These served the double purpose of testing the behavior of the optimization algorithm (PRO) as well as the precision of the forward dose calculation. Finally, patient QA on a series of clinical cases was performed with different methods. In addition to the well established in-phantom QA, we evaluated the portal dosimetry solution within the Varian approach. RESULTS: For routine machine QA, the "Snooker Cue" test on the EPID proved to be the most sensitive to overall problem detection. It is also the most practical one. The "Twinkle" and "Sunrise" tests were useful to obtain well differentiated information on the individual treatment delivery components. The AAA8.9 dose calculations showed excellent agreement with all corresponding measurements, except in areas where the 2.5 mm fixed fluence resolution was insufficient to accurately model the tongue and groove effect or the dose through nearly closed opposing leafs. Such cases benefited from the increased fluence resolution in AAA10.0. In the clinical RA fields, these effects were smeared out spatially and the impact of the fluence resolution was considerably less pronounced. The RA plans on the artificial structure sets demonstrated some interesting characteristics of the PRO8.9 optimizer, such as a sometimes unexpected dependence on the collimator rotation and a suboptimal coverage of targets within lung tissue. Although the portal dosimetry was successfully validated, we are reluctant to use it as a sole means of patient QA as long as no gantry angle information is embedded. CONCLUSIONS: The all-in validation program allows a systematic approach in monitoring the different levels of RA treatments. With the systematic approach comes a better understanding of both the capabilities and the limits of the used solution. The program can be useful for implementation, but also for the validation of major upgrades.


Assuntos
Radioterapia de Intensidade Modulada/normas , Algoritmos , Humanos , Imagens de Fantasmas , Controle de Qualidade , Radiometria , Planejamento da Radioterapia Assistida por Computador , Reprodutibilidade dos Testes
15.
Opt Express ; 13(9): 3340-7, 2005 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-19495236

RESUMO

We propose that self-pumped degenerate four-wave mixing may be used to produce novel diode laser systems where lasing is based on nonlinear guiding of the laser beams inside the active semiconductor. The fundamental process responsible for the interaction is spatial hole burning in semiconductor amplifiers. The gain and index gratings created by the modulation of the carrier density in the active gain medium lead to selective amplification of one spatial mode and suppression of all other modes. This mechanism allows the laser system to be operated far above its threshold with an almost diffraction limited output beam. The third order nonlinear susceptibility of the non-linear material, which determines the strength of the induced gratings, depends on the angle between the interacting beams in the four-wave mixing configuration. It is shown theoretically that a narrow range of angles exist where the induced gratings are strong and where mode suppression of higher order spatial modes are obtained simultaneously. Experimental evidence sustaining these findings is given.

16.
Opt Express ; 12(4): 609-16, 2004 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-19474863

RESUMO

We demonstrate a novel technique for narrow bandwidth and highly improved lateral mode operation of a high-power broad area laser diode. The system uses simultaneous feedback from the first diffracted order and the zeroth reflected order of a diffraction grating. The two feedback paths lead to simultaneously improvement of the spectral and spatial properties of the laser diode. The laser system operates in the well-known asymmetric double-lobed far field pattern with the larger lobe being extracted as the output. The bandwidth of the output beam is measured to 0.07 nm, which corresponds to an improvement of a factor of 17 compared to the bandwidth of the freely running laser. The output from the system contains 54% of the energy reaching the grating, or 75% of the power reflected into the zeroth order. The improvements in both the spatial and temporal coherence opens the possibility of using this laser system in applications such as frequency doubling and pumping of optical parametric oscillators.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...