4.
Sterile World ; 5(2): 2-4, 1983 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-10261350

RESUMO

A local exhaust manifold was attached to two different tabletop ethylene oxide sterilizers. One tabletop sterilizer had a built-in cycle purge feature, while the other had the standard single terminal vacuum cycle. Operator exposure and environmental levels of ethylene oxide were determined with and without local exhaust, and with and without purge cycle. Results from both charcoal tube collection samples and infra-red analysis clearly demonstrated the benefit of a local exhaust coupled with cycle purge in reducing operator exposure to and environmental contamination by ethylene oxide to nearly undetectable levels.


Assuntos
Poluentes Ocupacionais do Ar , Poluentes Atmosféricos , Almoxarifado Central Hospitalar/normas , Óxido de Etileno , Esterilização/instrumentação , Humanos , Estados Unidos
11.
Hospitals ; 55(3): 67-9, 1981 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-7450698

RESUMO

Test results indicate greatly reduced operator exposure to, and environmental levels of, ethylene oxide from ETO sterilizers that are fitted for both local exhaust and purge cycle.


Assuntos
Almoxarifado Central Hospitalar , Óxido de Etileno/efeitos adversos , Esterilização/instrumentação , Ventilação , Exposição Ambiental , Humanos , Segurança
13.
Hospitals ; 54(13): 66-8, 1980 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-7390438

RESUMO

Proper air change rates and venting systems in hospital central service sterilization rooms can reduce employees' exposure to ethylene oxide.


Assuntos
Almoxarifado Central Hospitalar/normas , Óxido de Etileno/efeitos adversos , Ventilação/normas , Poluentes Ocupacionais do Ar/efeitos adversos , Arquitetura Hospitalar/normas , Humanos , Esterilização/instrumentação , Fatores de Tempo
20.
Am J Hosp Pharm ; 32(9): 892-7, 1975 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-1190244

RESUMO

A new method for intermittent administration of i.v. fluids which maintains the advantages of the piggyback system but at a lower cost than the piggyback system is described. The system uses a volume control chamber as a replacement for a minibag or minibottle to deliver doses of different medications. The volume control set, when attached in the prescribed fashion, permits the flow from the primary i.v. solution to resume automatically when the volume control chamber is empty. One large-volume container of i.v. fluid can be used to dilute many doses of different drugs in the volume control chamber rather than one small-volume container per dose. No significant difficulties have been encountered with the mechanics of the system, and nursing response has been favorable.


Assuntos
Injeções Intravenosas/instrumentação , Seringas , Custos e Análise de Custo , Embalagem de Medicamentos , Armazenamento de Medicamentos , Injeções Intravenosas/métodos