1.
J Diabetes Sci Technol ; 17(2): 336-344, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-34711074

RESUMO

BACKGROUND: Frequent blood glucose level (BGL) monitoring is essential for effective diabetes management. Poor compliance is common due to the painful finger pricking or subcutaneous lancet implantation required from existing technologies. There are currently no commercially available non-invasive devices that can effectively measure BGL. In this real-world study, a prototype non-invasive continuous glucose monitoring system (NI-CGM) developed as a wearable ring was used to collect bioimpedance data. The aim was to develop a mathematical model that could use these bioimpedance data to estimate BGL in real time. METHODS: The prototype NI-CGM was worn by 14 adult participants with type 2 diabetes for 14 days in an observational clinical study. Bioimpedance data were collected alongside paired BGL measurements taken with a Food and Drug Administration (FDA)-approved self-monitoring blood glucose (SMBG) meter and an FDA-approved CGM. The SMBG meter data were used to improve CGM accuracy, and CGM data to develop the mathematical model. RESULTS: A gradient boosted model was developed using a randomized 80-20 training-test split of data. The estimated BGL from the model had a Mean Absolute Relative Difference (MARD) of 17.9%, with the Parkes error grid (PEG) analysis showing 99% of values in clinically acceptable zones A and B. CONCLUSIONS: This study demonstrated the reliability of the prototype NI-CGM at collecting bioimpedance data in a real-world scenario. These data were used to train a model that could successfully estimate BGL with a promising MARD and clinically relevant PEG result. These results will enable continued development of the prototype NI-CGM as a wearable ring.


Assuntos
Diabetes Mellitus Tipo 1 , Diabetes Mellitus Tipo 2 , Dispositivos Eletrônicos Vestíveis , Adulto , Humanos , Glicemia/análise , Automonitorização da Glicemia , Reprodutibilidade dos Testes
2.
ERJ Open Res ; 7(4)2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34651039

RESUMO

Oscillometry is increasingly adopted in respiratory clinics, but many recommendations regarding measurement settings and quality control remain subjective. The aim of this study was to investigate the optimal number of measurements and acceptable within-session coefficient of variation (CoV) in health, asthma and COPD. 15 healthy, 15 asthma and 15 COPD adult participants were recruited. Eight consecutive 30-s measurements were made using an oscillometry device, from which resistance at 5 Hz (R rs5 ) was examined. The effect of progressively including a greater number of measurements on R rs5 and its within-session CoV was investigated. Data were analysed using one-way repeated-measures ANOVA with Bonferroni post hoc test. The CoV(R rs5 ) of the first three measurements was 6.7±4.7%, 9.7±5.7% and 12.6±11.2% in healthy, asthma and COPD participants, respectively. Both mean R rs5 and CoV(R rs5 ) were not statistically different when progressively including four to eight measurements. Selecting the three closest R rs5 values over an increasing number of measurements progressively decreased the CoV(R rs5 ). In order for ≥95% of participants to fall within a target CoV(R rs5 ) of 10%, four or more, five and six measurements were needed in health, asthma and COPD, respectively. Within-session variability of oscillometry is increased in disease. Furthermore, the higher number of measurements required to achieve a set target for asthma and COPD patients may not be practical in a clinical setting. Provided technical acceptability of measurements is established, i.e. by removing artefacts and outliers, then a CoV of 10% is a marker of quality in most patients, but we suggest higher CoVs up to 15-20% should still be reportable.

3.
ERJ Open Res ; 7(1)2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33532464

RESUMO

Higher body mass index (BMI) is associated with less severe airway obstruction in older asthma patients with fixed airflow obstruction. This is potentially mediated through BMI-related mechanisms that increase lung stiffness (i.e. reduce lung compliance). https://bit.ly/3jBwCNy.

4.
Respirology ; 25(6): 613-619, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-31482693

RESUMO

BACKGROUND AND OBJECTIVE: Fixed airflow obstruction (FAO) in asthma occurs despite optimal inhaled treatment and no smoking history, and remains a significant problem, particularly with increasing age and duration of asthma. Increased lung compliance and loss of lung elastic recoil has been observed in older people with asthma, but their link to FAO has not been established. We determined the relationship between abnormal lung elasticity and airflow obstruction in asthma. METHODS: Non-smoking asthmatic subjects aged >40 years, treated with 2 months of high-dose inhaled corticosteroid/long-acting beta-agonist (ICS/LABA), had FAO measured by spirometry, and respiratory system resistance at 5 Hz (Rrs5 ) and respiratory system reactance at 5 Hz (Xrs5 ) measured by forced oscillation technique. Lung compliance (K) and elastic recoil (B/A) were calculated from pressure-volume curves measured by an oesophageal balloon. Linear correlations between K and B/A, and forced expiratory volume in 1 s/forced vital capacity (FEV1 /FVC), Rrs5 and Xrs5 were assessed. RESULTS: Eighteen subjects (11 males; mean ± SD age: 64 ± 8 years, asthma duration: 39 ± 22 years) had moderate FAO measured by spirometry ((mean ± SD z-score) post-bronchodilator FEV1 : -2.2 ± 0.5, FVC: -0.7 ± 1.0, FEV1 /FVC: -2.6 ± 0.7) and by increased Rrs5 (median (IQR) z-score) 2.7 (1.9 to 3.2) and decreased Xrs5 : -4.1(-2.4 to -7.3). Lung compliance (K) was increased in 9 of 18 subjects and lung elastic recoil (B/A) reduced in 5 of 18 subjects. FEV1 /FVC correlated negatively with K (rs = -0.60, P = 0.008) and Rrs5 correlated negatively with B/A (rs = -0.52, P = 0.026), independent of age. Xrs5 did not correlate with lung elasticity indices. CONCLUSION: Increased lung compliance and loss of elastic recoil relate to airflow obstruction in older non-smoking asthmatic subjects, independent of ageing. Thus, structural lung tissue changes may contribute to persistent, steroid-resistant airflow obstruction. CLINICAL TRIAL REGISTRATION: ACTRN126150000985583 at anzctr.org.au (UTN: U1111-1156-2795).


Assuntos
Corticosteroides/uso terapêutico , Asma/tratamento farmacológico , Volume Expiratório Forçado/fisiologia , Complacência Pulmonar/fisiologia , Capacidade Vital/fisiologia , Idoso , Asma/patologia , Elasticidade/efeitos dos fármacos , Feminino , Humanos , Pulmão/patologia , Masculino , Pessoa de Meia-Idade , Doença Pulmonar Obstrutiva Crônica , Testes de Função Respiratória/métodos , Espirometria/métodos