Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 103
Filtrar
1.
Anal Bioanal Chem ; 415(5): 809-821, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36507958

RESUMO

The US National Institute of Standards and Technology (NIST) developed a Standard Reference Material® (SRM®) 3949 Folate Vitamers in Frozen Human Serum to replace SRM 1955 Homocysteine and Folate in Human Serum. The presence of increased endogenous levels of folic acid and 5-methyltetrahydrofolate (5mTHF) in SRM 3949, enhanced folate stability via addition of ascorbic acid, and inclusion of values for additional minor folates are improvements over SRM 1955 that should better serve the clinical folate measurement community. The new SRM contains folates at three levels. To produce SRM 3949, pilot sera were collected from 15 individual donors, 5 of whom were given a 400-µg folic acid supplement 1 h prior to blood draw to increase serum levels of 5mTHF and folic acid for the high-level material. To stabilize the folates, 0.5% (mass concentration) ascorbic acid was added as soon as possible after preparation of serum. These pilot sera were screened for five folates plus the pyrazino-s-triazine derivative of 4-α-hydroxy-5-methyltetrahydrofolate (MeFox) at the US Centers for Disease Control and Prevention (CDC) by isotope dilution liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS). Based on these results, a blending protocol was specified to obtain the three desired folate concentrations for SRM 3949. ID-LC-MS/MS analysis at the CDC and NIST was utilized to assign values for folic acid and 5mTHF, as well as several minor folates.


Assuntos
Ácido Fólico , Espectrometria de Massas em Tandem , Humanos , Ácido Fólico/análise , Cromatografia Líquida/métodos , Espectrometria de Massas em Tandem/métodos , Padrões de Referência , Ácido Ascórbico
2.
Chromatographia ; 85(4)2022.
Artigo em Inglês | MEDLINE | ID: mdl-38567378

RESUMO

Molecular shape can provide a basis for chromatographic separations that is distinct from other interaction mechanisms often considered in liquid chromatography. Molecular shape recognition, or shape selectivity, is most evident for the separation of isomeric compounds that have constrained molecular structures, such as polycyclic aromatic hydrocarbons. A central feature of shape-selective columns is conformational order within the stationary phase; this aspect of stationary phase morphology is revealed through spectroscopic studies and molecular dynamics simulations, and is correlated with chromatographic performance.

3.
J Chromatogr A ; 1614: 460732, 2020 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-31836308

RESUMO

Differences in the characteristics of seventeen commercial C-30 liquid chromatographic columns were studied for the separation of carotenoid isomers. A mixture consisting of nine xanthophyll and hydrocarbon carotenoids were separated under conditions carefully chosen to reveal changes in selectivity. The influence of the mobile phase composition, column temperature, and mobile phase flow rate were evaluated. Shape selectivity was characterized with Standard Reference Material (SRM) 869b Column Selectivity Test Mixture, for correlation with carotenoid retention behavior. Regular changes were observed across a broad spectrum of shape selectivity characteristics as indicated by SRM 869b. Better separations of carotenoid isomers were achieved with C-30 columns than were possible with C-18 columns, even after optimization of separation conditions.


Assuntos
Carotenoides/isolamento & purificação , Cromatografia Líquida/instrumentação , Resinas de Troca Iônica/química , Resinas de Troca Iônica/normas , Hidrocarbonetos/química , Isomerismo
4.
Artigo em Inglês | MEDLINE | ID: mdl-34877157
5.
Chromatographia ; 83(1)2019.
Artigo em Inglês | MEDLINE | ID: mdl-33033412

RESUMO

We continue herein the exploration of detector orthogonality in size-based macromolecular separations. Previously [5], the sensitivity of viscometric detection was juxtaposed to that of differential refractometry (DRI) and light scattering (LS, both static and dynamic), and it was shown that viscometry is a truly orthogonal detection method to both DRI and LS. Here, via the size-exclusion chromatography (SEC) analysis of blends of polystyrene and poly(methyl methacrylate), we demonstrate the orthogonality of DRI to UV detection and, within the UV region of the electromagnetic spectrum, we also explore the phenomenon of "wavelength orthogonality:" Analytes observable by one detection method are shown to be spectroscopically invisible to another method, or even to the same detection method when operating at a different wavelength. While generally focusing on blends of analytes of different molar masses (different sizes in solution), we also investigate the less-explored case of blends of coeluting analytes (same sizes in solution) where detector orthogonality can inform one's knowledge of whether or not coelution has occurred. Finally, by incorporating a fluorescence (FL) detector into the experimental set-up, we demonstrate not only its orthogonality to DRI detection but also its sensitivity to the presence of even minor (≈ 1%) fluorescent components in a sample. We hope the present experiments assist in understanding the complementarity of different spectroscopic detection methods and also help highlight the potential role of FL detection, a method which has been largely overlooked in macromolecular separation science.

6.
J Chromatogr A ; 1574: 114-121, 2018 Nov 02.
Artigo em Inglês | MEDLINE | ID: mdl-30220428

RESUMO

The research presented here describes the development of two analytical methods for use in the certification of a ginsenoside calibration solution Standard Reference Material (SRM) 3389 consisting of seven ginsenosides: Rg1, Re, Rf, Rb1, Rc, Rb2, and Rd. The new methods utilized the liquid chromatographic (LC) separation of ginsenoside mixtures with absorbance detection (UV) and mass spectrometry (MS). Ginsenosides Rb3, Rg2, Rg3, Rh1, and Rh2 were evaluated for use as internal standards for LC/MS measurements. The 12 ginsenosides were baseline resolved by gradient elution LC/UV, with an initial mobile phase composition of 22% acetonitrile and 78% water, flow rate of 0.7 mL/min, and column temperature of 25 °C. The work presented here includes a detailed investigation into the optimization of the chromatographic conditions to minimize measurement biases that result from unresolved constituents. Temperature and mobile phase composition are known to play a significant role in column selectivity; however, flow rate is expected to influence primarily the separation efficiency and detection sensitivity. In the current study, column selectivity changed with changes in flow rate and the relative retention of ginsenoside Rg2 and Rh1 changed as the flow rate increased from 0.6 mL/min to 1.0 mL/min.


Assuntos
Calibragem , Técnicas de Química Analítica/métodos , Técnicas de Química Analítica/normas , Cromatografia Líquida , Ginsenosídeos/análise , Espectrometria de Massas em Tandem , Acetonitrilas , Técnicas de Química Analítica/instrumentação , Cromatografia Líquida de Alta Pressão/métodos , Panax/química , Padrões de Referência
7.
Cancer Epidemiol Biomarkers Prev ; 27(9): 1083-1090, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-29853481

RESUMO

Background: Biomarkers of tobacco exposure have a central role in studies of tobacco use and nicotine intake. The most significant exposure markers are nicotine itself and its metabolites in urine. Therefore, it is important to evaluate the performance of laboratories conducting these biomarker measurements.Methods: This report presents the results from a method performance study involving 11 laboratories from 6 countries that are currently active in this area. Each laboratory assayed blind replicates of seven human urine pools at various concentrations on three separate days. The samples included five pools blended from smoker and nonsmoker urine sources, and two additional blank urine samples fortified with pure nicotine, cotinine, and hydroxycotinine standards. All laboratories used their own methods, and all were based on some form of liquid chromatography/tandem mass spectrometry.Results: Overall, good agreement was found among the laboratories in this study. Intralaboratory precision was good, and in the fortified pools, the mean bias observed was < + 3.5% for nicotine, approximately 1.2% for hydroxycotinine, and less than 1% for cotinine (1 outlier excluded in each case). Both indirect and direct methods for analyzing the glucuronides gave comparable results.Conclusions: This evaluation indicates that the experienced laboratories participating in this study can produce reliable and comparable human urinary nicotine metabolic profiles in samples from people with significant recent exposure to nicotine.Impact: This work supports the reliability and agreement of an international group of established laboratories measuring nicotine and its metabolites in urine in support of nicotine exposure studies. Cancer Epidemiol Biomarkers Prev; 27(9); 1083-90. ©2018 AACR.


Assuntos
Biomarcadores/urina , Cotinina/análogos & derivados , Glucuronídeos/urina , Nicotina/urina , Fumar/epidemiologia , Fumar/urina , Cotinina/urina , Humanos , Valor Preditivo dos Testes , Prevalência , Reprodutibilidade dos Testes , Estados Unidos/epidemiologia
8.
J Hazard Mater ; 354: 275-282, 2018 07 15.
Artigo em Inglês | MEDLINE | ID: mdl-29778037

RESUMO

As the production mass of multiwall carbon nanotubes (MWCNT) increases, the potential for human and environmental exposure to MWCNTs may also increase. We have shown that exposing an aqueous suspension of pristine MWCNTs to an intense oxidative treatment in an electrochemical reactor, equipped with an efficient hydroxyl radical generating Boron Doped Diamond (BDD) anode, leads to their almost complete mineralization. Thermal optical transmittance analysis showed a total carbon mass loss of over two orders of magnitude due to the electrochemical treatment, a result consistent with measurements of the degraded MWCNT suspensions using UV-vis absorbance. Liquid chromatography data excludes substantial accumulation of the low molecular weight reaction products. Therefore, up to 99% of the initially suspended MWCNT mass is completely mineralized into gaseous products such as CO2 and volatile organic carbon. Scanning electron microscopy (SEM) images show sporadic opaque carbon clusters suggesting the remaining nanotubes are transformed into structure-less carbon during their electrochemical mineralization. Environmental toxicity of pristine and degraded MWCNTs was assessed using Caenorhabditis elegans nematodes and revealed a major reduction in the MWCNT toxicity after treatment in the electrochemical flow-by reactor.


Assuntos
Nanotubos de Carbono/química , Poluentes Químicos da Água/química , Animais , Caenorhabditis elegans/efeitos dos fármacos , Técnicas Eletroquímicas , Eletroquímica , Microscopia Eletrônica de Varredura , Nanotubos de Carbono/toxicidade , Nanotubos de Carbono/ultraestrutura , Poluentes Químicos da Água/toxicidade , Purificação da Água/métodos
9.
Anal Bioanal Chem ; 410(5): 1511-1524, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29238863

RESUMO

Retention indices for 67 polycyclic aromatic sulfur heterocycles (PASHs) and 80 alkyl-substituted PASHs were determined using normal-phase liquid chromatography (NPLC) on an aminopropyl (NH2) stationary phase. The retention behavior of PASH on the NH2 phase is correlated with the number of aromatic carbon atoms and two structural characteristics have a significant influence on their retention: non-planarity (thickness, T) and the position of the sulfur atom in the bay-region of the structure. Correlations between solute retention on the NH2 phase and T of PASHs were investigated for three cata-condensed (cata-) PASH isomer groups: (a) 13 four-ring molecular mass (MM) 234 Da cata-PASHs, (b) 20 five-ring MM 284 Da cata-PASHs, and (c) 12 six-ring MM 334 Da cata-PASHs. Correlation coefficients ranged from r = -0.49 (MM 234 Da) to r = -0.65 (MM 334 Da), which were significantly lower than structurally similar PAH isomer groups (r = -0.70 to r = -0.99). The NPLC retention behavior of the PASHs are compared to similar results for PAHs.

10.
Anal Bioanal Chem ; 410(3): 1123-1137, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29119256

RESUMO

Retention indices (I) for 45 polycyclic aromatic hydrocarbons (PAHs) and 63 methyl-substituted PAHs were determined by gas chromatography - mass spectrometry (GC-MS) using two different stationary phases: a Rxi-PAH phase (a "higher phenyl-content stationary phase") and a 50% (mole fraction) liquid crystalline dimethylpolysiloxane phase. Retention data were obtained for parent PAHs from molecular mass (MM) 128 g/mol (naphthalene) to 328 g/mol (benzo[c]picene) and for 12 sets of methyl-PAHs (methylfluorenes, methylanthracenes, methylphenanthrenes, methylfluoranthenes, methylpyrenes, methylbenz[a]anthracenes, methylbenzo[c]phenanthrenes, methylchrysenes, methyltriphenylenes, methylbenzo[a]pyrenes, methylperylenes, and methylpicenes). Molecular shape descriptors such as length-to-breath ratio (L/B) and thickness (T) were determined for all the PAHs studied. Correlation between I and L/B ratio was evaluated for both stationary phases with a better correlation observed for the 50% liquid crystalline phase (correlation coefficients ranging from 0.22 to 1.00). Graphical Abstract GC separation of six methylchrysene isomers (m/z 242) on two different stationary phases: 50 % phenyl-like methylpolysiloxane phase and 50 % liquid crystalline phase. Retention indices (I) are plotted as a function of L/B for both phases. The data marker numbers identify each isomer based on methyl-substitution position.

11.
Anal Bioanal Chem ; 410(3): 885-896, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28660336

RESUMO

The relationship of reversed-phase liquid chromatography (RPLC) retention on a polymeric C18 stationary phase and the shape of polycyclic aromatic hydrocarbons (PAHs) was investigated for three-ring to seven-ring cata-condensed isomers. We report the first RPLC separation for six-ring and seven-ring cata-condensed PAH isomers. Correlations of LC retention and shape parameters (length-to-breath ratio, L/B and thickness, T) were investigated for 2 three-ring isomers (molecular mass 178 Da), 5 four-ring isomers (molecular mass 228 Da), 11 five-ring isomers (molecular mass 278 Da), 17 six-ring isomers (molecular mass 328 Da), and 20 seven-ring isomers (molecular mass 378 Da). Significant linear correlations were found for all isomer groups (r = 0.71 to 0.94). Nonplanarity of the PAH isomers was found to influence retention (i.e., nonplanar isomers eluting earlier than expected based on L/B) and linear correlations of retention vs. T for isomer groups containing nonplanar isomers were significant (r = 0.71 to 0.86). Graphical abstract.

12.
Anal Methods ; 102018.
Artigo em Inglês | MEDLINE | ID: mdl-31093300

RESUMO

The identification of isomeric polycyclic aromatic hydrocarbons (PAHs) in complex samples via reversed-phase liquid chromatography (RPLC) with fluorescence detection (FL) is normally based on matching the chromatographic retention times of suspected peaks of interest with reference standards. Since no spectral information is obtained during the chromatographic run, the accurate identification of co-eluting PAHs with similar chromatographic behaviors requires confirmation with additional chromatographic methods. This is particularly true for the analysis of PAH isomers with the relative molecular mass (MM, g/mol) 302. The work presented here explores the information content of room-temperature fluorescence spectra for the analysis of PAHs with MM 302 in the Standard Reference Material (SRM) 1597a. Fluorescence spectra were recorded under stop-flow conditions with the aid of a commercial HPLC system. Of the 21 MM 302 PAHs known to be present in the SRM 1597a, 20 were tentatively identified based on retention times and the presence of 18 was confirmed based on excitation and emission spectral profiles.

13.
Anal Chem ; 89(19): 10461-10467, 2017 10 03.
Artigo em Inglês | MEDLINE | ID: mdl-28930436

RESUMO

A new tobacco filler Standard Reference Material (SRM) has been issued by the National Institute of Standards and Technology (NIST) in September 2016 with certified and reference mass fraction values for nicotine, N-nitrosonornicotine, 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanone, and volatiles. The constituents have been determined by multiple analytical methods with measurements at NIST and at the Centers for Disease Control and Prevention, and with confirmatory measurements by commercial laboratories. This effort highlights the development of the first SRM for reduced nicotine and reduced tobacco-specific nitrosamines with certified values for composition.


Assuntos
Cromatografia Gasosa-Espectrometria de Massas/métodos , Espectrometria de Massas em Tandem/métodos , Produtos do Tabaco/análise , Cromatografia Líquida de Alta Pressão/métodos , Cromatografia Líquida de Alta Pressão/normas , Congelamento , Cromatografia Gasosa-Espectrometria de Massas/normas , Nicotina/análise , Nicotina/normas , Nitrosaminas/análise , Nitrosaminas/normas , Transição de Fase , Padrões de Referência , Espectrometria de Massas em Tandem/normas , Produtos do Tabaco/normas , Compostos Orgânicos Voláteis/análise , Compostos Orgânicos Voláteis/normas
14.
J AOAC Int ; 100(5): 1294-1303, 2017 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-28917261

RESUMO

The National Institute of Standards and Technology (NIST), in collaboration with the National Institutes of Health Office of Dietary Supplements and the Vitamin D Standardization Program, has recently issued a new serum-matrix Standard Reference Material (SRM): 2973 Vitamin D Metabolites in Frozen Human Serum (High Level). SRM 2973 was designed to provide a serum material with a total 25-hydroxyvitamin D [25(OH)D] concentration near 100 nmol/L to complement the existing serum-based SRMs with values assigned for total 25(OH)D between 20 and 80 nmol/L. Values were assigned for 25-hydroxyvitamin D2 [25(OH)D2], 25-hydroxyvitamin D3 [25(OH)D3], 3-epi-25(OH)D3, and total 25(OH)D [the sum of 25(OH)D2 + 25(OH)D3] using the NIST isotope dilution LC with tandem MS (MS/MS) reference measurement procedure (RMP) and related methods. SRM 2973 has a certified value of 98.4 ± 2.1 nmol/L for 25(OH)D3 and reference values of 1.59 ± 0.05 nmol/L for 25(OH)D2 and 5.23 ± 0.20 nmol/L for 3-epi-25(OH)D3. In addition, a candidate RMP for 24R,25-dihydroxyvitamin D3 [24R,25(OH)2D3] based on LC-MS/MS was used to assign values to SRM 2973 and the existing SRM 972a Vitamin D Metabolites in Frozen Human Serum. Reference values for 24R,25(OH)2D3 were assigned to SRM 2973 (7.51 ± 0.26 nmol/L) and the four levels of SRM 972a: Level 1 (6.38 ± 0.23 nmol/L), Level 2 (3.39 ± 0.12 nmol/L), Level 3 (3.88 ± 0.013 nmol/L), and Level 4 (6.32 ± 0.22 nmol/L). The development of SRM 2973 [with a higher concentration of 25(OH)D3] and the addition of values for 24R,25(OH)2D3 assigned to both SRM 972a and SRM 2973 provide laboratories involved in vitamin D measurements with improved QA tools.


Assuntos
25-Hidroxivitamina D 2/sangue , Análise Química do Sangue/normas , Calcifediol/sangue , Humanos , Espectrometria de Massas em Tandem/normas , Estados Unidos , Vitamina D
15.
J AOAC Int ; 100(5): 1260-1276, 2017 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-28863788

RESUMO

Since 2005, the National Institute of Standards and Technology (NIST) has collaborated with the National Institutes of Health (NIH), Office of Dietary Supplements (ODS) to improve the quality of measurements related to human nutritional markers of vitamin D status. In support of the NIH-ODS Vitamin D Initiative, including the Vitamin D Standardization Program (VDSP), NIST efforts have focused on (1) development of validated analytical methods, including reference measurement procedures (RMPs); (2) development of Standard Reference Materials (SRMs); (3) value assignment of critical study samples using NIST RMPs; and (4) development and coordination of laboratory measurement QA programs. As a result of this collaboration, NIST has developed RMPs for 25-hydroxyvitamin D2 [25(OH)D2], 25(OH)D3, and 24R,25-dihydroxyvitamin D3 [24R,25(OH)2D3]; disseminated serum-based SRMs with values assigned for 25(OH)D2, 25(OH)D3, 3-epi-25(OH)D3, and 24R,25(OH)2D3; assigned values for critical samples for VDSP studies, including an extensive interlaboratory comparison and reference material commutability study; provided an accuracy basis for the Vitamin D External Quality Assurance Scheme; coordinated the first accuracy-based measurement QA program for the determination of 25(OH)D2, 25(OH)D3, and 3-epi-25(OH)D3 in human serum/plasma; and developed methods and SRMs for the determination of vitamin D and 25(OH)D in food and supplement matrix SRMs. The details of these activities and their benefit and impact to the NIH-ODS Vitamin D Initiative are described.


Assuntos
25-Hidroxivitamina D 2/sangue , Análise Química do Sangue/normas , Humanos , National Institutes of Health (U.S.) , Controle de Qualidade , Estados Unidos , Vitamina D
16.
J AOAC Int ; 100(5): 1277-1287, 2017 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-28847346

RESUMO

Until recently, the Vitamin D External Quality Assessment Scheme (DEQAS) assessed the performance of various assays for the determination of serum total 25-hydroxyvitamin D [25(OH)D] by using a consensus mean based on the all-laboratory trimmed mean (ALTM) of the approximately 1000 participants' results. Since October 2012, the National Institute of Standards and Technology (NIST), as part of the Vitamin D Standardization Program, has participated in DEQAS by analyzing the quarterly serum sample sets using an isotope dilution LC-tandem MS (ID LC-MS/MS) reference measurement procedure to assign an accuracy-based target value for serum total 25(OH)D. NIST has analyzed 90 DEQAS samples (18 exercises × 5 samples/exercise) to assign target values. The NIST-assigned values are compared with the ALTM and the biases assessed for various assays used by the participants, e.g., LC-MS/MS, HPLC, and several ligand-binding assays. The NIST-value assignment process and the results of the analyses of the 90 DEQAS samples are summarized. The absolute mean bias between the NIST-assigned values and the ALTM was 5.6%, with 10% of the samples having biases >10%. Benefits of the accuracy-based target values are presented, including for sample sets with high concentrations of 25(OH)D2 and 3-epi-25(OH)D3.


Assuntos
Análise Química do Sangue/normas , Vitamina D/análogos & derivados , Calcifediol , Cromatografia Líquida de Alta Pressão/normas , Humanos , Espectrometria de Massas em Tandem/normas , Estados Unidos , Vitamina D/sangue
17.
Anal Bioanal Chem ; 409(21): 5171-5183, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28664340

RESUMO

A normal-phase liquid chromatography (NPLC) fractionation procedure was developed for the characterization of a complex mixture of polycyclic aromatic hydrocarbons (PAHs) from a coal tar sample (Standard Reference Material (SRM) 1597a). Using a semi-preparative aminopropyl (NH2) LC column, the coal tar sample was separated using NPLC based on the number of aromatic carbons; a total of 14 NPLC fractions were collected. SRM 1597a was analyzed before and after NPLC fractionation by using gas chromatography/mass spectrometry (GC/MS) with a 50% phenyl stationary phase. The NPLC-GC/MS method presented in this study allowed for the identification of 72 PAHs and 56 MePAHs. These identifications were based on the NPLC retention times for authentic reference standards, GC retention times for authentic reference standards, and the predominant molecular ion peak in the mass spectrum. Most noteworthy was the determination of dibenzo[a,l]pyrene, which could not be measured directly by GC/MS because of low concentration and co-elution with dibenzo[j,l]fluoranthene. The NPLC-GC/MS procedure also allowed for the tentative identification of 74 PAHs and 117 MePAHs based on the molecular ion peak only. This study represents the most comprehensive qualitative characterization of SRM 1597a to date. Graphical abstract NPLC-GC/MS analysis for the six-ring MM 302 Da PAH isomers in SRM 1597a.

18.
Anal Bioanal Chem ; 409(22): 5291-5305, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28717893

RESUMO

Retention indices for 124 polycyclic aromatic hydrocarbons (PAHs) and 62 methyl-substituted (Me-) PAHs were determined using normal-phase liquid chromatography (NPLC) on a aminopropyl (NH2) stationary phase. PAH retention behavior on the NH2 phase is correlated to the total number of aromatic carbons in the PAH structure. Within an isomer group, non-planar isomers generally elute earlier than planar isomers. MePAHs generally elute slightly later but in the same region as the parent PAHs. Correlations between PAH retention behavior on the NH2 phase and PAH thickness (T) values were investigated to determine the influence of non-planarity for isomeric PAHs with four to seven aromatic rings. Correlation coefficients ranged from r = 0.19 (five-ring peri-condensed molecular mass (MM) 252 Da) to r = -0.99 (five-ring cata-condensed MM 278 Da). In the case of the smaller PAHs (MM ≤ 252 Da), most of the PAHs had a planar structure and provided a low correlation. In the case of larger PAHs (MM ≥ 278 Da), nonplanarity had a significant influence on the retention behavior and good correlation between retention and T was obtained for the MM 278 Da, MM 302 Da, MM 328 Da, and MM 378 Da isomer sets. Graphical abstract NPLC separation of the three-, four-, five-, and six-ring PAH isomers with different number of aromatic carbon atoms and degrees of non-planarity (Thickness, T). The inserted figure plots the number of aromatic carbon atoms vs. the log I value for the 124 parent PAHs.

19.
J AOAC Int ; 100(5): 1253-1259, 2017 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-28623654

RESUMO

Assay variability has been cited as an obstacle to establishing optimal vitamin D exposure. As part of the Vitamin D Standardization Program (VDSP) effort to standardize the measurement of total 25-hydroxyvitamin D [25(OH)D], the value assignment of total 25(OH)D in 50 single-donor serum samples was performed using two isotope-dilution LC with tandem MS methods. Both methods are recognized as reference measurement procedures (RMPs) by the Joint Committee for Traceability in Laboratory Medicine. These samples and their assigned values serve as the foundation for several aspects of the VDSP. To our knowledge, this is the first time that two RMPs have been used to assign 25(OH)D values to such a large number of serum samples.


Assuntos
Análise Química do Sangue/normas , Vitamina D/análogos & derivados , Cromatografia Líquida/normas , Humanos , Padrões de Referência , Espectrometria de Massas em Tandem/normas , Vitamina D/sangue
20.
Anal Chem ; 89(9): 4907-4913, 2017 05 02.
Artigo em Inglês | MEDLINE | ID: mdl-28375002

RESUMO

The National Institute of Standards and Technology (NIST) has developed Standard Reference Material (SRM) 972a Vitamin D Metabolites in Frozen Human Serum as a replacement for SRM 972, which is no longer available. SRM 972a was developed in collaboration with the National Institutes of Health's Office of Dietary Supplements. In contrast to the previous reference material, three of the four levels of SRM 972a are composed of unmodified human serum. This SRM has certified and reference values for the following 25-hydroxyvitamin D [25(OH)D] species: 25(OH)D2, 25(OH)D3, and 3-epi-25(OH)D3. The value assignment and certification process included three isotope-dilution mass spectrometry approaches, with measurements performed at NIST and at the Centers for Disease Control and Prevention (CDC). The value assignment methods employed have been modified from those utilized for the previous SRM, and all three approaches now incorporate chromatographic resolution of the stereoisomers, 25(OH)D3 and 3-epi-25(OH)D3.


Assuntos
25-Hidroxivitamina D 2/sangue , Calcifediol/sangue , Cromatografia Líquida/normas , Espectrometria de Massas/normas , 25-Hidroxivitamina D 2/normas , Calcifediol/química , Calcifediol/normas , Humanos , Padrões de Referência , Valores de Referência , Estereoisomerismo , Estados Unidos , United States Government Agencies
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...