Clin Biomech (Bristol, Avon) ; 91: 105543, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34871913

RESUMO

BACKGROUND: The periprosthetic femoral fracture is one of the most severe complications after total hip arthroplasty and is associated with an increased mortality. The underlying causes and the patient- and implant-specific risk factors of periprosthetic femoral fractures remain insufficiently understood. The aim of this study was to gain a more profound understanding of the underlying fracture mechanisms and to provide experimental datasets for validation of computational models. METHODS: Six cadaveric femurs were implanted with straight hip stems (Zweymueller design) and loaded until fracture reproducing the clinically relevant load cases stumbling and sideways fall. Displacements and the strain distribution on the surface of the femurs and implants, as well as the fracture load and implant subsidence were measured. FINDINGS: For the load case stumbling the mean fracture load was 6743 N and two different mechanisms leading to fracture could be identified: high subsidence with low femoral bending and small subsidence with high femoral bending. For the load case sideways fall the mean fracture load was 1757 N and both tested femurs fractured due to a rotation of the hip stem around its own axis. The detailed datasets provided by this study can be used in future computational models. INTERPRETATION: We demonstrated that the underlying fracture mechanisms of periprosthetic femoral fractures can be fundamentally different in the load case stumbling. The seating and exact position of the hip stem in the femur may correlate with implant subsidence and therefore lead to different types of fracture mechanisms resulting in different patient-specific fracture risks.


Assuntos
Artroplastia de Quadril , Fraturas do Fêmur , Prótese de Quadril , Fraturas Periprotéticas , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/métodos , Fraturas do Fêmur/etiologia , Fraturas do Fêmur/cirurgia , Fêmur/cirurgia , Prótese de Quadril/efeitos adversos , Humanos , Fraturas Periprotéticas/etiologia , Fraturas Periprotéticas/cirurgia , Desenho de Prótese , Reoperação , Estudos Retrospectivos
2.
Materials (Basel) ; 14(18)2021 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-34576539

RESUMO

The aim of the present work was to investigate the 'fine granular area' (FGA) formation based on artificially generated internal defects in additively manufactured Ti6Al4V specimens in the early stage of fatigue crack growth in the 'very high cycle fatigue' (VHCF) regime. Fatigue tests were performed with constant amplitude at pure tension-compression loading (R = -1) using an ultrasonic fatigue testing setup. Failed specimens were investigated using optical microscopy, high-resolution 'scanning electron microscopy' (SEM), and 'focused ion beam' (FIB) techniques. Further, the paper introduces alternative proposals to identify the FGA layer beneath the fracture surfaces in terms of the 'cross section polishing' (CSP) technique and metallic grindings with special attention paid to the crack origin, the surrounding microstructure, and the expansion of the nanograin layer beneath the fracture surface. Different existing fracture mechanical approaches were applied to evaluate if an FGA formation is possible. Moreover, the results were discussed in comparison to the experimental findings.

3.
Materials (Basel) ; 13(20)2020 Oct 17.
Artigo em Inglês | MEDLINE | ID: mdl-33080913

RESUMO

The present study aims to carry out an experimental, analytical and numerical investigation of the monotonic and fatigue performance of electron beam melted Ti-6Al-4V structures. Therefore, tensile tests, multiple step tests and strain-life tests were performed on machined EBM Ti-6Al-4V solid samples. An elastic-plastic material model in combination with a numerical damage model was examined according to the experimental tensile tests. Analytical models proposed by Ramberg and Osgood, as well as Coffin and Manson were obtained to describe the cyclic stress-strain curves and strain-life curves, respectively. The fracture surfaces of the tested samples and the influence of different build directions were analyzed. A prediction of the static and fatigue material properties is of particular importance, e.g., for the safe application of additively manufactured load-bearing implant structures. Based on the determined analytical and numerical models, the material and product behavior of complex electron beam melted structures under cyclic loading and fatigue life determination can be investigated in the early stages of the product development process.

4.
Materials (Basel) ; 13(19)2020 Sep 27.
Artigo em Inglês | MEDLINE | ID: mdl-32992532

RESUMO

In age-hardened high-strength aluminum alloys, the area with and around a joint has a large impact on the load-bearing capacity of a welded structure. Therefore, in this study the fracture behavior of welded EN AW 6082 T6 plates is investigated experimentally and numerically. From butt joints, smooth and notched tensile specimens as well as shear specimens have been manufactured and tested for the base material (BM), heat-affected zone (HAZ) and fusion zone (FZ). With numerical simulations of these tests, the dependency of the fracture strain on the stress triaxiality is determined, and two phenomenological fracture criteria are calibrated. Whereas the one-parameter Rice-Tracey/Cockcroft-Latham (RTCL) criterion describes the behavior of the tension specimens as accurately as the two-parameter Bao-Wierzbicki (BW) criterion, the BW criterion is more accurate for shear tests. Subsequently, the material model is validated on axial compression tests of welded X-profiles. The experiments comprise tests with different plate thicknesses (8 mm, 10 mm and 12 mm) and varying strain rates (up to 1/s locally), showing the same behavior for all specimens. After crack initiation within the FZ, coalescence of cracks leads to crack growth in axial direction and a subsequent reduction of the load-bearing capacity. This behavior is reproduced well by the numerical simulations with the BW criterion, whereas simulations with the RTCL criterion predict fracture initiation at too high displacements. Overall, the results show the strong influence of the ductility of the FZ on the crushing behavior of welded X-profiles.

5.
Comput Methods Biomech Biomed Engin ; 22(1): 25-37, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30449160

RESUMO

Polyurethane (PU) foam is a material often used in biomechanical experiments and demands for the definition of crushable foam plasticity (CFP) in numerical simulations of the primary stability and deformation of implants, to describe the crushing behaviour appropriately. Material data of PU foams with five different densities (10-40 pounds per cubic foot were ascertained experimentally in uniaxial compression test and used to calibrate CFP models for finite element modelling. Additionally, experimental and numerical deformation, push-out and lever-out tests of press-fit acetabular cups were carried out to assess the influence of the chosen material definition (linear elastic and CFP) on the numerical results. Comparison of the experimentally and numerically determined force-displacement curves of the uniaxial compression test showed a mean deviation of less than 3%. In primary stability testing, the deviation between the experimental and numerical results was in a range of 0%-27% for CFP modelling and 64%-341% for the linear elastic model. The material definition selected, highly influenced the numerical results in the current study. The use of a CFP model is recommended for further numerical simulations, when a deformation of the foam beyond the yield strength is likely to occur.


Assuntos
Acetábulo/patologia , Análise de Elementos Finitos , Modelos Biológicos , Poliuretanos/farmacologia , Calibragem , Força Compressiva , Elasticidade , Prótese de Quadril , Humanos , Análise Numérica Assistida por Computador , Reprodutibilidade dos Testes
6.
Materials (Basel) ; 11(8)2018 Aug 09.
Artigo em Inglês | MEDLINE | ID: mdl-30096950

RESUMO

Wide softening zones are typical for welded joints of age hardened aluminium alloys. In this study, the microstructure evolution and distribution of mechanical properties resulting from welding processes of the aluminium alloy EN AW-6082 (AlSi1MgMn) was analysed by both in-situ and ex-situ investigations. The in-situ thermal analyses (TMA) included differential scanning calorimetry (DSC), which was used to characterise the dissolution and precipitation behaviour in the heat affected zone (HAZ) of welded joints. Thermo-mechanical analysis by means of compression tests was used to determine the mechanical properties of various states of the microstructure after the welding heat input. The necessary temperature⁻time courses in the HAZ for these methods were measured using thermocouples during welding. Additionally, ex-situ tensile tests were done both on specimens from the fusion zone and on welded joints, and their in-depth analysis with digital image correlation (DIC) accompanied by finite element simulations serve for the description of flow curves in different areas of the weld. The combination of these methods and the discussion of their results make an essential contribution to understand the influence of welding heat on the material properties, particularly on the softening behaviour. Furthermore, the distributed strength characteristic of the welded connections is required for an applicable estimation of the load-bearing capacity of welded aluminium structures by numerical methods.

7.
Acta Bioeng Biomech ; 19(3): 155-163, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29205219

RESUMO

PURPOSE: In THA a sufficient primary implant stability is the precondition for successful secondary stability. Industrial foams of different densities have been used for primary stability investigations. The aim of this study was to analyse and compare the insertion behaviour of threaded and press-fit cups in vivo and ex vivo using bone substitutes with various densities. METHODS: Two threaded (Bicon Plus®, Trident® TC) and one press-fit cup (Trident PSL®) were inserted by orthopaedic surgeons (S1, S2) into 10, 20 and 31 pcf blocks, using modified surgical instruments allowing measurements of the insertion forces and torques. Furthermore, the insertion behaviour of two cups were analysed intraoperatively. RESULTS: Torques for the threaded cups increased while bone substitute density increased. Maximum insertion torques were observed for S2 with 102 Nm for the Bicon Plus® in 20 pcf blocks and 77 Nm for the Trident® TC in 31 pcf blocks, which compares to the in vivo measurement (85 Nm). The average insertion forces for the press-fit cup varied from 5.2 to 6.8 kN (S1) and 7.2-11.5 kN (S2) ex vivo. Intraoperatively an average insertion force of 8.0 kN was determined. CONCLUSIONS: Implantation behaviour was influenced by acetabular cup design, bone substitute and experience of the surgeon. No specific density of bone substitute could be favoured for ex vivo investigations on the implantation behaviour of acetabular cups. The use synthetic bone blocks of high density (31 pcf) led to problems regarding cup orientation and seating. Therefore, bone substitutes used should be critically scrutinized in terms of the comparability to the in vivo situation.


Assuntos
Acetábulo/fisiologia , Acetábulo/cirurgia , Artroplastia de Quadril/métodos , Parafusos Ósseos , Prótese de Quadril , Desenho de Equipamento , Análise de Falha de Equipamento , Fricção , Pressão , Estresse Mecânico , Torque
8.
J Orthop Sci ; 18(2): 264-70, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23377753

RESUMO

BACKGROUND: To increase the range of motion of total hip endoprostheses, prosthetic heads need to be enlarged, which implies that the cup and/or liner thickness must decrease. This may have negative effects on the wear rate, because the acetabular cups and liners could deform during press-fit implantation and hip joint loading. We compared the metal cup and polyethylene liner deformations that occurred when different wall thicknesses were used in order to evaluate the resulting changes in the clearance of the articulating region. METHODS: A parametric finite element model utilized three cup and liner wall thicknesses to analyze cup and liner deformations after press-fit implantation into the pelvic bone. The resultant hip joint force during heel strike was applied while the femur was fixed, accounting for physiological muscle forces. The deformation behavior of the liner under joint loading was therefore assessed as a function of the head diameter and the resulting clearance. RESULTS: Press-fit implantation showed diametral cup deformations of 0.096, 0.034, and 0.014 mm for cup wall thicknesses of 3, 5, and 7 mm, respectively. The largest deformations (average 0.084 ± 0.003 mm) of liners with thicknesses of 4, 6, and 8 mm occurred with the smallest cup wall thickness (3 mm). The smallest liner deformation (0.011 mm) was obtained with largest cup and liner wall thicknesses. Under joint loading, liner deformations in thin-walled acetabular cups (3 mm) reduced the initial clearance by about 50 %. CONCLUSION: Acetabular press-fit cups with wall thicknesses of ≤5 mm should only be used in combination with polyethylene liners >6 mm thick in order to minimize the reduction in clearance.


Assuntos
Acetábulo/fisiopatologia , Acetábulo/cirurgia , Artroplastia de Quadril , Prótese de Quadril , Polietilenos , Desenho de Prótese , Desenho Assistido por Computador , Análise de Elementos Finitos , Humanos , Teste de Materiais , Falha de Prótese , Amplitude de Movimento Articular/fisiologia , Propriedades de Superfície