Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
N Z Med J ; 137(1593): 14-30, 2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-38603784

RESUMO

AIMS: To examine the impact of intensive management of type 1 diabetes (T1D) from diagnosis on HbA1c 12 months from diagnosis. METHODS: HbA1c measured 12 months after diagnosis for 70 consecutively newly diagnosed children with T1D following implementation of an intensive management protocol was compared with 70 children consecutively diagnosed immediately pre-implementation. Intensive management involved carbohydrate counting and flexible insulin dosing from first meal with subcutaneous insulin, targeted blood glucose levels from 4-8mmol/L irrespective of time of day, avoidance of twice daily insulin regimen and promotion of continuous glucose monitoring (CGM). HbA1c, diabetes technology use and insulin regimen at 12 months post-diagnosis were compared. RESULTS: The post-intensive management implementation cohort had an improved mean HbA1c of 58.2±15.3mmol/mol vs 63.7±10.7mmol/mol at 12 months (p=0.014). The proportion of young people with diabetes meeting a target HbA1c of <53mmol/mol at 12 months improved from 11% to 40% (p=<0.001). There was a reduction of twice daily insulin regimen from 66% to 11% (p=<0.001), and increased CGM use from 57% to 76% (p=0.02). CONCLUSION: Intensive management when implemented with consistent messaging from the multi-disciplinary team resulted in clinic-wide improvements in HbA1c and the proportion meeting HbA1c targets.


Assuntos
Diabetes Mellitus Tipo 1 , Criança , Humanos , Adolescente , Diabetes Mellitus Tipo 1/diagnóstico , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hemoglobinas Glicadas , Glicemia , Automonitorização da Glicemia/métodos , Estudos Prospectivos , Nova Zelândia , Insulina/uso terapêutico , Hipoglicemiantes/uso terapêutico
2.
Diabetes Technol Ther ; 26(1): 40-48, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37823890

RESUMO

Objective: To investigate 12-month glycemic and psychosocial changes following transition from multiple daily injections (MDI) to advanced hybrid closed-loop (AHCL) therapy in youth (aged 13-25 years) with type 1 diabetes and suboptimal glycemia (glycated hemoglobin [HbA1c] ≥8.5% [69 mmol/mol]). Research Design and Methods: Prospective, single arm, dual-center study in 20 participants. Extension phase outcomes reported after 12 months, including HbA1c, time in glycemic ranges, AHCL system performance, and psychosocial questionnaires assessing quality of life, diabetes treatment, and sleep. Results: After 12 months, 19 out of 20 participants continued to use AHCL. Average time-in-range 70-180 mg/dL (3.9-10.0 mmol/L) improved from 27.6% ± 13.2% to 62.5% ± 11.4%. This translated to an average 2.5 percentage-point (27.1 mmol/mol) improvement in HbA1c from 10.5% ± 2.1% (91.2 mmol/mol) at baseline to 8.0% ± 0.9% (64.1 mmol/mol) at 12 months. Psychosocial questionnaires and very high HbA1c at study entry indicated significant diabetes-associated burden for both individuals and parents. After 12 months, improvements were observed in general and diabetes-specific health-related quality of life, as well as in diabetes treatment satisfaction. Safety data were reassuring with a diabetic ketoacidosis rate of 0.15 per participant-year after 12 months of AHCL (compared to 0.25 per participant-year in the 12 months before the study). Conclusions: After 12 months of AHCL usage, this study highlights the potential for substantial and sustained glycemic and psychosocial improvements among individuals experiencing considerable diabetes burden and suboptimal glycemia, following their switch from MDI to AHCL.


Assuntos
Diabetes Mellitus Tipo 1 , Humanos , Adolescente , Diabetes Mellitus Tipo 1/tratamento farmacológico , Diabetes Mellitus Tipo 1/psicologia , Hipoglicemiantes/uso terapêutico , Glucose , Insulina/uso terapêutico , Qualidade de Vida , Estudos Prospectivos , Resultado do Tratamento , Sistemas de Infusão de Insulina , Automonitorização da Glicemia , Glicemia
3.
J Diabetes Metab Disord ; 22(1): 861-871, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37250371

RESUMO

Purpose: Open-source automated insulin delivery (AID) is used by thousands of people with type 1 diabetes (T1D), but has unknown generalisability to marginalised ethnic groups. This study explored experiences of Indigenous Maori participants in the CREATE trial with use of an open-source AID system to identify enablers/barriers to health equity. Methods: The CREATE randomised trial compared open-source AID (OpenAPS algorithm on an Android phone with a Bluetooth-connected pump) to sensor-augmented pump therapy. Kaupapa Maori Research methodology was used in this sub-study. Ten semi-structured interviews with Maori participants (5 children, 5 adults) and whanau (extended family) were completed. Interviews were recorded and transcribed, and data were analysed thematically. NVivo was used for descriptive and pattern coding. Results: Enablers/barriers to equity aligned with four themes: access (to diabetes technologies), training/support, operation (of open-source AID), and outcomes. Participants described a sense of empowerment, and improved quality of life, wellbeing, and glycaemia. Parents felt reassured by the system's ability to control glucose, and children were granted greater independence. Participants were able to use the open-source AID system with ease to suit whanau needs, and technical problems were manageable with healthcare professional support. All participants identified structures in the health system precluding equitable utilisation of diabetes technologies for Maori. Conclusion: Maori experienced open-source AID positively, and aspired to use this therapy; however, structural and socio-economic barriers to equity were identified. This research proposes strength-based solutions which should be considered in the redesign of diabetes services to improve health outcomes for Maori with T1D.Trial Registration: The CREATE trial, encompassing this qualitative sub-study, was registered with the Australian New Zealand Clinical Trials Registry (ACTRN12620000034932p) on the 20th January 2020. Supplementary Information: The online version contains supplementary material available at 10.1007/s40200-023-01215-3.

4.
J Cachexia Sarcopenia Muscle ; 14(2): 781-793, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36797054

RESUMO

BACKGROUND: Rhabdomyosarcoma (RMS) is an aggressive soft tissue sarcoma that most often develops in children. Chemoradiation therapy is a standard treatment modality; however, the detrimental long-term skeletal muscle consequences of this therapy in juvenile cancer survivors include muscle atrophy and fibrosis resulting in decreased physical performance. Using a novel model of murine resistance and endurance exercise training, we investigate its role in preventing the long-term effects of juvenile RMS plus therapy. METHODS: Four-week-old male (n = 10) and female (n = 10) C57Bl/6J mice were injected with M3-9-M RMS cell into the left gastrocnemius with the right limb serving as an internal control (CON). Mice received a systemic vincristine injection and then five doses of 4.8 Gy of gamma radiation localized to the left hindlimb (RMS + Tx). Mice were then randomly divided into either sedentary (SED) or resistance and endurance exercise training (RET) groups. Changes in exercise performance, body composition, myocellular adaptations and the inflammatory/fibrotic transcriptome were assessed. RESULTS: RET improved endurance performance (P < 0.0001) and body composition (P = 0.0004) compared to SED. RMS + Tx resulted in significantly lower muscle weight (P = 0.015) and significantly smaller myofibre cross-sectional area (CSA) (P = 0.014). Conversely, RET resulted in significantly higher muscle weight (P = 0.030) and significantly larger Type IIA (P = 0.014) and IIB (P = 0.015) fibre CSA. RMS + Tx resulted in significantly more muscle fibrosis (P = 0.028), which was not prevented by RET. RMS + Tx resulted in significantly fewer mononuclear cells (P < 0.05) and muscle satellite (stem) cells (MuSCs) (P < 0.05) and significantly more immune cells (P < 0.05) than CON. RET resulted in significantly more fibro-adipogenic progenitors (P < 0.05), a trend for more MuSCs (P = 0.076) than SED and significantly more endothelial cells specifically in the RMS + Tx limb. Transcriptomic changes revealed significantly higher expression of inflammatory and fibrotic genes in RMS + Tx, which was prevented by RET. In the RMS + Tx model, RET also significantly altered expression of genes involved in extracellular matrix turnover. CONCLUSIONS: Our study suggests that RET preserves muscle mass and performance in a model of juvenile RMS survivorship while partially restoring cellular dynamics and the inflammatory and fibrotic transcriptome.


Assuntos
Rabdomiossarcoma , Transcriptoma , Humanos , Masculino , Feminino , Camundongos , Animais , Células Endoteliais , Músculo Esquelético/patologia , Rabdomiossarcoma/metabolismo , Fibrose
5.
Diabetes Technol Ther ; 25(4): 250-259, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36763345

RESUMO

Aim: To assess long-term efficacy and safety of open-source automated insulin delivery (AID) in children and adults (7-70 years) with type 1 diabetes. Methods: Both arms of a 24-week randomized controlled trial comparing open-source AID (OpenAPS algorithm within a modified version of AndroidAPS, preproduction DANA-i™ insulin pump, Dexcom G6 continuous glucose monitor) with sensor-augmented pump therapy (SAPT), entered a 24-week continuation phase where the SAPT arm (termed SAPT-AID) crossed over to join the open-source AID arm (termed AID-AID). Most participants (69/94) used a preproduction YpsoPump® insulin pump during the continuation phase. Analyses incorporated all 52 weeks of data, and combined between-group and within-subject differences to calculate an overall "treatment effect" of AID versus SAPT. Results: Mean time in range (TIR; 3.9-10 mmol/L [70-180 mg/dL]) was 12.2% higher with AID than SAPT (95% confidence interval [CI] 10.4 to 14.1; P < 0.001). TIR was 56.9% (95% CI 54.2 to 59.6) with SAPT and 69.1% (95% CI 67.1 to 71.1) with AID. The treatment effect did not differ by age (P = 0.39) or insulin pump type (P = 0.37). HbA1c was 5.1 mmol/mol lower [0.5%] with AID (95% CI -6.6 to -3.6; P < 0.001). There were no episodes of diabetic ketoacidosis or severe hypoglycemia with either treatment over the 48 weeks. Six participants (all in SAPT-AID) withdrew: three with hardware issues, two preferred SAPT, and one with infusion-site skin irritation. Conclusion: Further evaluation of the community derived automated insulin delivery (CREATE) trial to 48 weeks confirms that open-source AID is efficacious and safe with different insulin pumps, and demonstrates sustained glycemic improvements without additional safety concerns.


Assuntos
Diabetes Mellitus Tipo 1 , Hipoglicemia , Adulto , Humanos , Criança , Insulina/uso terapêutico , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hipoglicemiantes/uso terapêutico , Hipoglicemia/induzido quimicamente , Glicemia , Insulina Regular Humana/uso terapêutico , Sistemas de Infusão de Insulina
6.
Diabetes Care ; 46(3): 628-632, 2023 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-36689621

RESUMO

OBJECTIVE: To evaluate glycemic outcomes in youth (aged 13-25 years) with type 1 diabetes and high-risk glycemic control (HbA1c ≥8.5% [69 mmol/mol]) on multiple daily injection (MDI) therapy after transitioning to advanced hybrid closed loop (AHCL) therapy. RESEARCH DESIGN AND METHODS: This prospective, 3-month, single-arm, dual-center study enrolled 20 participants, and all completed the study. RESULTS: HbA1c decreased from 10.5 ± 2.1% (91.2 ± 22.8 mmol/mol) at baseline to 7.6 ± 1.1% (59.7 ± 11.9 mmol/mol), and time spent in target range 70-180 mg/dL (3.9-10.0 mmol/L) increased from 27.6 ± 13.2% at baseline to 66.5 ± 9.8% after 3 months of AHCL. Two episodes of diabetic ketoacidosis attributed to infusion set failure occurred. CONCLUSIONS: AHCL has the potential to improve suboptimal glycemia in youth with type 1 diabetes previously on MDI therapy.


Assuntos
Diabetes Mellitus Tipo 1 , Adolescente , Humanos , Glicemia , Automonitorização da Glicemia , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hemoglobinas Glicadas , Hipoglicemiantes/uso terapêutico , Insulina/uso terapêutico , Sistemas de Infusão de Insulina , Estudos Prospectivos , Adulto Jovem , Adulto
7.
N Engl J Med ; 387(10): 869-881, 2022 09 08.
Artigo em Inglês | MEDLINE | ID: mdl-36069869

RESUMO

BACKGROUND: Open-source automated insulin delivery (AID) systems are used by many patients with type 1 diabetes. Data are needed on the efficacy and safety of an open-source AID system. METHODS: In this multicenter, open-label, randomized, controlled trial, we assigned patients with type 1 diabetes in a 1:1 ratio to use an open-source AID system or a sensor-augmented insulin pump (control). The patients included both children (defined as 7 to 15 years of age) and adults (defined as 16 to 70 years of age). The AID system was a modified version of AndroidAPS 2.8 (with a standard OpenAPS 0.7.0 algorithm) paired with a preproduction DANA-i insulin pump and Dexcom G6 CGM, which has an Android smartphone application as the user interface. The primary outcome was the percentage of time in the target glucose range of 70 to 180 mg per deciliter (3.9 to 10.0 mmol per liter) between days 155 and 168 (the final 2 weeks of the trial). RESULTS: A total of 97 patients (48 children and 49 adults) underwent randomization (44 to open-source AID and 53 to the control group). At 24 weeks, the mean (±SD) time in the target range increased from 61.2±12.3% to 71.2±12.1% in the AID group and decreased from 57.7±14.3% to 54.5±16.0% in the control group (adjusted difference, 14 percentage points; 95% confidence interval, 9.2 to 18.8; P<0.001), with no treatment effect according to age (P = 0.56). Patients in the AID group spent 3 hours 21 minutes more in the target range per day than those in the control group. No severe hypoglycemia or diabetic ketoacidosis occurred in either group. Two patients in the AID group withdrew from the trial owing to connectivity issues. CONCLUSIONS: In children and adults with type 1 diabetes, the use of an open-source AID system resulted in a significantly higher percentage of time in the target glucose range than the use of a sensor-augmented insulin pump at 24 weeks. (Supported by the Health Research Council of New Zealand; Australian New Zealand Clinical Trials Registry number, ACTRN12620000034932.).


Assuntos
Glicemia , Diabetes Mellitus Tipo 1 , Hipoglicemiantes , Bombas de Infusão , Insulina , Adolescente , Adulto , Idoso , Austrália , Glicemia/análise , Criança , Diabetes Mellitus Tipo 1/sangue , Diabetes Mellitus Tipo 1/tratamento farmacológico , Humanos , Hipoglicemiantes/administração & dosagem , Insulina/administração & dosagem , Pessoa de Meia-Idade , Adulto Jovem
8.
Diabet Med ; 39(5): e14750, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-34826158

RESUMO

BACKGROUND: Open-source automated insulin delivery (AID) is a user-driven treatment modality used by thousands globally. Healthcare professionals' (HCPs) ability to support users of this technology is limited by a lack of knowledge of these systems. AIMS: To describe the challenges experienced by HCPs supporting participants' use of open-source automated insulin delivery in the Community deRivEd AuTomatEd insulin delivery (CREATE) study. METHODS: Data were collected prospectively from the study team's fortnightly meetings and Slack Workspace (Slack Technologies, Ltd. 2018) during the first 4 months of the trial. Key topics were identified from minutes of meetings. Slack conversations were categorised by topic, with the number of posts per conversation, number of sites per conversation and involvement of experts in open-source AID being recorded. RESULTS: In the first 4 months of the trial, there were 254 conversations in Slack with a mean of 5.2 (±4.25) posts per conversation. The most frequent learning challenge was insulin pump and cannula problems relating to the DANA-iTM insulin pump, which totalled 24.0% of all conversations. Experts on open-source AID use were involved in 83.3% of conversations. CONCLUSIONS: A significant proportion of challenges related to specific devices, rather than AID. Challenges relating to the functioning of open-source AID were more likely to involve input from experts in open-source AID. This is the first report of challenges experienced by a multidisciplinary team in a supported open-source environment that may inform expectations in routine clinical care.


Assuntos
Diabetes Mellitus Tipo 1 , Pâncreas Artificial , Atenção à Saúde , Diabetes Mellitus Tipo 1/tratamento farmacológico , Humanos , Hipoglicemiantes/uso terapêutico , Insulina/uso terapêutico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...