Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
Pacing Clin Electrophysiol ; 47(7): 977-979, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38641950

RESUMO

BACKGROUND: Lead dwell time is the single strongest predictor of failure and complications in transvenous lead extraction. OBJECTIVES: To report the success rate and complications of transvenous lead extractions with implant dwell time of at least 15 years. METHODS: Procedural and patient data were prospectively collected into a database. The excimer laser was the primary method for lead extraction with the use of mechanical rotational sheaths and femoral snares at operator discretion. RESULTS: A total of 442 patients between 2011 and 2020 underwent lead extraction (705 leads) primarily for infection or device failure at our high-volume center. Forty-one patients with 71 leads > 15 years old were included in this cohort. Mean patient age was 53.5 ± 18.5 years, 67.5% were male. Mean lead dwell time was 19.6 ± 4.4 years. Thirty-six of 41 (88%) patients had successful extraction of all leads compared to 96% in the remaining 401 patients, p value.004. Of the five patients without fully successful extractions two of these patients had abandoned leads (three total) that were clinically significant. There were two (4.9%) major complications in the very old lead group and six (1.5%) in the other group. In the very old lead group, one patient experienced right atrial appendage perforation requiring surgical repair and recovered well. One patient experienced new complete heart block requiring 2 min of CPR but did well thereafter. There was no procedure-related mortality. CONCLUSIONS: Despite challenges posed by older leads, very old leads can be safely and effectively extracted with low complication rates.


Assuntos
Remoção de Dispositivo , Marca-Passo Artificial , Humanos , Masculino , Feminino , Remoção de Dispositivo/métodos , Pessoa de Meia-Idade , Desfibriladores Implantáveis , Fatores de Tempo , Falha de Equipamento , Estudos Prospectivos
2.
Artigo em Inglês | MEDLINE | ID: mdl-37188871

RESUMO

BACKGROUND: Pulsed field ablation (PFA) may have a superior safety profile compared to other technologies, but it has the potential to cause gaseous microbubbles (MB), which may be associated with cerebral emboli. Limited relative safety data has been published regarding PFA in the left ventricle (LV). METHODS: Healthy and chronic myocardial infarction (MI) swine underwent PFA (monopolar, biphasic, 25 Amps) in the LV using an irrigated focal catheter under intra-cardiac echocardiography (ICE) guidance for MB monitoring. Two control swine received air MBs through the lumen of the ablation catheter. Swine underwent brain MRI before and after PFA (or control air MB injection). Gross pathology and histology of brains with abnormal MRI findings were performed. RESULTS: Four healthy and 5 chronic MI swine underwent 124 left ventricular PFA applications. No PFA-related MB formation was noted on ICE. Both control swine developed multiple acute emboli in the thalamus and caudate on DWI, ADC, and FLAIR brain MRI images in response to air MB injection. Of the 9 PFA swine, there were no abnormalities on ADC or FLAIR images. There was one hyperintense focus in the left putamen on the DWI trace image, but the absence of ADC or FLAIR affirmation suggested it was artifact. Gross pathology and histopathology of this region did not detect any abnormalities. CONCLUSIONS: Focal monopolar biphasic PFA of both healthy and chronically infarcted left ventricular myocardium does not generate any MB or cerebral emboli observable on ICE and brain MRI.

3.
Europace ; 25(4): 1503-1509, 2023 04 15.
Artigo em Inglês | MEDLINE | ID: mdl-36793229

RESUMO

AIMS: Data on ventricular pulsed-field ablation (PFA) are sparse in the setting of chronic myocardial infarction (MI). The objective of this study was to compare the biophysical and histopathologic characteristics of PFA in healthy and MI swine ventricular myocardium. METHODS AND RESULTS: Myocardial infarction swine (n = 8) underwent coronary balloon occlusion and survived for 30 days. We then performed endocardial unipolar, biphasic PFA of the MI border zone and a dense scar with electroanatomic mapping and using an irrigated contact force (CF)-sensing catheter with the CENTAURI System (Galaxy Medical). Lesion and biophysical characteristics were compared with three controls: MI swine undergoing thermal ablation, MI swine undergoing no ablation, and healthy swine undergoing similar PFA applications that included linear lesion sets. Tissues were systematically assessed by gross pathology utilizing 2,3,5-triphenyl-2H-tetrazolium chloride staining and histologically with haematoxylin and eosin and trichrome. Pulsed-field ablation in healthy myocardium generated well-demarcated ellipsoid lesions (7.2 ± 2.1 mm depth) with contraction band necrosis and myocytolysis. Pulsed-field ablation in MI demonstrated slightly smaller lesions (depth 5.3 ± 1.9 mm, P = 0.0002), and lesions infiltrated into the irregular scar border, resulting in contraction band necrosis and myocytolysis of surviving myocytes and extending to the epicardial border of the scar. Coagulative necrosis was present in 75% of thermal ablation controls but only in 16% of PFA lesions. Linear PFA resulted in contiguous linear lesions with no gaps in gross pathology. Neither CF nor local R-wave amplitude reduction correlated with lesion size. CONCLUSION: Pulsed-field ablation of a heterogeneous chronic MI scar effectively ablates surviving myocytes within and beyond the scar, demonstrating promise for the clinical ablation of scar-mediated ventricular arrhythmias.


Assuntos
Ablação por Cateter , Infarto do Miocárdio , Taquicardia Ventricular , Suínos , Animais , Cicatriz , Miocárdio/patologia , Ventrículos do Coração , Coração , Arritmias Cardíacas , Ablação por Cateter/métodos
4.
J Am Heart Assoc ; 11(15): e025301, 2022 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-35904213

RESUMO

Background Ventricular arrhythmias (VAs) and their treatment have been associated with psychological distress and diminished quality of life (QOL). We administered a battery of patient-reported outcome measures (PROMs) to patients seeing an electrophysiologist and psychologist in a multidisciplinary VA clinic for patients referred for consideration of catheter ablation for sustained VAs or implantable cardioverter-defibrillator therapies. Methods and Results In this retrospective study of the initial VA clinic visit, we analyzed PROMs of: anxiety and depression symptoms, visual analog scales for physical health status and quality of life, cardiac anxiety, implantable cardioverter-defibrillator acceptance, and implantable cardioverter-defibrillator shock anxiety. We quantitated baseline PROM score means and performed correlation analysis with clinical makers of cardiac and VA disease severity. We also performed an item-level analysis of each PROM question to quantify most frequent patient concerns. A total of 66 patients (56±15 years; 77% men) were included; 70% had prior implantable cardioverter-defibrillator shock, and 44% with prior VA ablation. Elevated symptoms of anxiety (53%) and depression (20%) were common. Younger patients had greater symptom burden of general health anxiety, cardiac anxiety, and shock anxiety, and lower device acceptance, but indices of VA burden such as number of ICD shocks and time since last ICD shock did not predict anxiety or depression. Item-level review of cardiac-specific PROMs revealed that >40% of patients expressed concern regarding resumption of physical activity, sex and employment. Conclusions Clinicians can expect elevated symptoms of depression, and cardiac and device-related anxiety among patients with VAs. Routine use of PROMs may elicit these symptoms, which were otherwise not predicted by arrhythmia burden.  Review of individual PROM items can facilitate targeting specific patient concerns, which commonly involved physical activity.


Assuntos
Desfibriladores Implantáveis , Qualidade de Vida , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/etiologia , Arritmias Cardíacas/terapia , Eletrofisiologia Cardíaca , Desfibriladores Implantáveis/efeitos adversos , Feminino , Humanos , Masculino , Medidas de Resultados Relatados pelo Paciente , Estudos Retrospectivos
5.
J Cardiovasc Electrophysiol ; 33(9): 1987-1991, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35726747

RESUMO

INTRODUCTION: Atrial fibrillation (AF) ablation is performed worldwide. To attract patients, hospitals frequently have webpages that tout the success of the procedure. The information disseminated to the public via these webpages has not been systematically reviewed. Our objective was to assess accuracy of information delivered to the public on hospital websites in regard to atrial AF ablation. METHODS: From July 2019 to January 2020, we performed a Google search for all US hospitals registered with Medicare to see if they had a webpage describing AF ablation. Resulting hospital webpages were abstracted for data on AF ablation success rates and risks. Success rates over 86%, the highest success rate in the medical literature, were deemed exaggerated. RESULTS: Among 4805 hospitals, 487 had webpages describing AF ablation and 33 discussed success rates of AF ablation. Twelve percentage reported exaggerated success rates, 3% referred to ablation as a cure, and 2.8% referred to ablation as a tool to eliminate AF. Less than 10% of webpages describing AF ablation noted the potential need for a second ablation to achieve the stated success rate and merely 16% mentioned risks of the procedure. One percentage of webpages directly suggested AF ablation could reduce risk of stroke while others indirectly suggested it by discussing cessation of anticoagulation. Two webpages mentioned reduced mortality. CONCLUSION: US hospital webpages rarely discuss AF ablation. When discussed, there were concerning unsubstantiated claims regarding mortality, stroke prevention, and need for medical therapy. This could lead to some patients undergoing AF ablation based on faulty understanding.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Acidente Vascular Cerebral , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Comunicação , Hospitais , Humanos , Medicare , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Resultado do Tratamento , Estados Unidos
7.
Heart Rhythm O2 ; 2(6Part B): 832-839, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34988534

RESUMO

Patient-reported outcome measures (PROMs) are a valuable metric for assessing the quality of life and overall well-being in patients with ventricular arrhythmias (VAs) and/or implantable cardioverter-defibrillators (ICDs). The incorporation of PROMs into the workflow of a VA clinic not only allows for more patient-centered care but also may improve detection and treatment of clinically relevant anxiety or depression symptoms. Awareness of the factors known to correlate with adverse PROM scores may guide PROM administration and subsequent referral to mental health services. Further, change or stability in PROM scores can be used as a gauge to guide the effectiveness of cardiac and psychological treatment in certain populations that are the focus of this manuscript: patients with ICDs (with and without shocks), cardiac arrest survivors, and those with inherited arrhythmia syndromes.

8.
J Interv Cardiol ; 2019: 8947204, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31772549

RESUMO

OBJECTIVE: To assess 1-year mortality after transcatheter aortic valve replacement (TAVR) in patients with bicuspid aortic stenosis (AS). BACKGROUND: Clinical trials have proven the beneficial effect of TAVR on mortality in patients with tricuspid AS. Individuals with bicuspid AS were excluded from these trials. METHODS: A meta-analysis using literature search from the Cochrane, PubMed, ClinicalTrials, SCOPUS, and EMBASE databases was conducted to determine the effect of TAVR on 1-year mortality in patients with bicuspid AS. Short-term outcomes that could potentially impact one-year mortality were analyzed. RESULTS: After evaluating 380 potential articles, 5 observational studies were selected. A total of 3890 patients treated with TAVR were included: 721 had bicuspid and 3,169 had tricuspid AS. No statistically significant difference between the baseline characteristics of the two groups of patients was seen outside of mean aortic gradient. Our primary endpoint of one-year all-cause mortality revealed 85 deaths in 719 patients (11.82%) with bicuspid AS compared to 467 deaths in 3100 patients (15.06%) with tricuspid AS, with no difference between both groups [relative risk (RR) 1.03; 95% CI 0.70-1.51]. Patients with bicuspid AS were associated with a decrease in device success (RR 0.62; 95% CI 0.45-0.84) and an increase in moderate-to-severe prosthetic valve regurgitation (RR 1.55; 95% CI 1.07-2.22) after TAVR compared to patients with tricuspid AS. The effect of meta-regression coefficients on one-year all-cause mortality was not statistically significant for any patient baseline characteristics. CONCLUSION: When comparing TAVR procedure in tricuspid AS versus bicuspid AS, there was no difference noted in one-year all-cause mortality.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica , Complicações Pós-Operatórias/mortalidade , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/patologia , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Humanos , Avaliação de Resultados em Cuidados de Saúde , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos
10.
Prog Cardiovasc Dis ; 62(3): 256-264, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31077726

RESUMO

Multiple clinical trials have demonstrated the efficacy of implantable cardioverter-defibrillators (ICDs) for the prevention of sudden cardiac death (SCD) among specific high-risk populations. However, it remains unclear how to optimally treat those patients who are at elevated risk of cardiac arrest but are not among the presently identified groups proven to benefit from an ICD, are unable to tolerate surgical device implantation, or refuse invasive therapies. The wearable cardioverter-defibrillator (WCD) is an alternative antiarrhythmic device that provides continuous cardiac monitoring and defibrillation capabilities through a noninvasive, electrode-based system. The WCD has been shown to be highly effective at restoration of sinus rhythm in patients with a ventricular tachyarrhythmia, and one randomized trial using the WCD in patients with recent myocardial infarction at elevated risk for arrhythmic death reported a decrease in overall mortality despite no SCD mortality benefit. The current clinical indications for WCD use are varied and continue to evolve as experience with this technology increases.


Assuntos
Desfibriladores , Dispositivos Eletrônicos Vestíveis , Morte Súbita Cardíaca/prevenção & controle , Eletrocardiografia , Desenho de Equipamento , Humanos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/terapia , Dispositivos Eletrônicos Vestíveis/efeitos adversos
12.
Adv Exp Med Biol ; 963: 337-358, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28197922

RESUMO

Sumoylation, a reversible post-transcriptional modification process, of proteins are involved in cellular differentiation, growth, and even motility by regulating various protein functions. Sumoylation is not limited to cytosolic proteins as recent evidence shows that nuclear proteins, those associated with membranes, and mitochondrial proteins are also sumoylated. Moreover, it is now known that sumoylation plays an important role in the process of major human ailments such as malignant, cardiovascular and neurological diseases. In this chapter, we will highlight and discuss how the localization of SUMO protease and SUMO E3 ligase in different compartments within a cell regulates biological processes that depend on sumoylation. First, we will discuss the key role of sumoylation in the nucleus, which leads to the development of endothelial dysfunction and atherosclerosis . We will then discuss how sumoylation of plasma membrane potassium channel proteins are involved in epilepsy and arrhythmia. Mitochondrial proteins are known to be also sumoylated, and the importance of dynamic-related protein 1 (DRP1) sumoylation on mitochondrial function will be discussed. As we will emphasize throughout this review, sumoylation plays crucial roles in different cellular compartments, which is coordinately regulated by the translocation of various SUMO proteases and SUMO E3 ligase. Comprehensive approach will be necessary to understand the molecular mechanism for efficiently moving around various enzymes that regulate sumoylation within cells.


Assuntos
Doenças Cardiovasculares/metabolismo , Sistema Cardiovascular/metabolismo , Doenças do Sistema Nervoso/metabolismo , Sistema Nervoso/metabolismo , Transdução de Sinais , Proteínas Modificadoras Pequenas Relacionadas à Ubiquitina/metabolismo , Sumoilação , Ubiquitina-Proteína Ligases/metabolismo , Animais , Doenças Cardiovasculares/patologia , Doenças Cardiovasculares/fisiopatologia , Sistema Cardiovascular/patologia , Sistema Cardiovascular/fisiopatologia , Humanos , Sistema Nervoso/patologia , Sistema Nervoso/fisiopatologia , Doenças do Sistema Nervoso/patologia , Doenças do Sistema Nervoso/fisiopatologia
13.
Cell Mol Life Sci ; 74(10): 1835-1858, 2017 05.
Artigo em Inglês | MEDLINE | ID: mdl-28039525

RESUMO

Atherosclerosis rarely develops in the region of arteries exposed to undisturbed flow (u-flow, unidirectional flow). Instead, atherogenesis occurs in the area exposed to disturbed flow (d-flow, multidirectional flow). Based on these general pathohistological observations, u-flow is considered to be athero-protective, while d-flow is atherogenic. The fact that u-flow and d-flow induce such clearly different biological responses in the wall of large arteries indicates that these two types of flow activate each distinct intracellular signaling cascade in vascular endothelial cells (ECs), which are directly exposed to blood flow. The ability of ECs to differentially respond to the two types of flow provides an opportunity to identify molecular events that lead to endothelial dysfunction and atherosclerosis. In this review, we will focus on various molecular events, which are differentially regulated by these two flow types. We will discuss how various kinases, ER stress, inflammasome, SUMOylation, and DNA methylation play roles in the differential flow response, endothelial dysfunction, and atherosclerosis. We will also discuss the interplay among the molecular events and how they coordinately regulate flow-dependent signaling and cellular responses. It is hoped that clear understanding of the way how the two flow types beget each unique phenotype in ECs will lead us to possible points of intervention against endothelial dysfunction and cardiovascular diseases.


Assuntos
Artérias/patologia , Aterosclerose/metabolismo , Aterosclerose/patologia , Células Endoteliais/patologia , Transdução de Sinais , Animais , Artérias/metabolismo , Aterosclerose/sangue , Estresse do Retículo Endoplasmático , Células Endoteliais/metabolismo , Humanos , Inflamassomos/metabolismo , Proteína Quinase 7 Ativada por Mitógeno/metabolismo , Proteínas Quinases Ativadas por Mitógeno/metabolismo , Proteína Quinase C/metabolismo , Proteína Tirosina Fosfatase não Receptora Tipo 11/metabolismo , Fluxo Sanguíneo Regional , Proteína de Ligação a Elemento Regulador de Esterol 2/metabolismo , Sumoilação , Proteína Supressora de Tumor p53/metabolismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...