Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
2.
Ann Thorac Surg ; 80(1): 6-13; discussion 13-4, 2005 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-15975331

RESUMO

BACKGROUND: Contemporary infant cardiopulmonary bypass circuits require a blood prime. Blood, especially when stored, generates an inflammatory response, and may contribute to organ dysfunction following cardiopulmonary bypass. We determined whether using a miniaturized circuit and an asanguineous prime attenuated the post-bypass inflammatory response, and improved right ventricular and pulmonary function. METHODS: Sixteen infant piglets were placed into 3 groups based on prime components: group I (fresh blood), group II (stored blood), and group III (miniaturized circuit and asanguineous prime). Piglets were placed on cardiopulmonary bypass (100 mL.kg(-1).min(-1)), cooled to 18 degrees C, and underwent continuous perfusion (50 mL.kg(-1).min(-1)) for 30 minutes. They were rewarmed and separated from bypass. Serum tumor necrosis factor-alpha, right ventricular function, and pulmonary function were measured before and 30 minutes after bypass. Neutrophil priming activity in fresh and stored donor blood was also assessed. RESULTS: Animals in group III had significantly improved cardiopulmonary function than the groups receiving blood (right ventricular cardiac index [mL.kg(-1).min(-1)]: group I [18.8 +/- 4.8], group II [21.5 +/- 6.2], and group III [81.2 +/- 11.4], p < 0.001; and pulmonary vascular resistance index [dynes.mL(-1).kg(-1)]: group I [1169 +/- 409], group II [1610 +/- 486], and group III [214 +/- 63], p = 0.03). Tumor necrosis factor-alpha (pg.mL(-1)) was lower in group III (1465 +/- 39) than in the groups receiving blood (3940 +/- 777), p = 0.002. Neutrophil priming activity (nmol.min(-1)) was also higher in stored blood (3.7 +/- 6) than in fresh blood (1.9 +/- 0.2), p = 0.02. CONCLUSIONS: We have devised a unique miniaturized circuit that allows an asanguineous prime without hemodilution in an infant swine model. The employment of this circuit attenuates the post-bypass inflammatory response and has salutary effects on cardiopulmonary function.


Assuntos
Ponte Cardiopulmonar/efeitos adversos , Ponte Cardiopulmonar/instrumentação , Insuficiência de Múltiplos Órgãos/imunologia , Animais , Sangue , Circulação Extracorpórea/instrumentação , Modelos Animais , Insuficiência de Múltiplos Órgãos/etiologia , Neutrófilos/imunologia , Suínos
3.
J Am Coll Cardiol ; 45(3): 433-8, 2005 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-15680724

RESUMO

OBJECTIVES: The purpose of this study was to investigate whether cardiac output (CO) could be accurately computed from live three-dimensional (3-D) Doppler echocardiographic data in an acute open-chested animal preparation. BACKGROUND: The accurate measurement of CO is important in both patient management and research. Current methods use invasive pulmonary artery catheters or two-dimensional (2-D) echocardiography or esophageal aortic Doppler measures, with the inherent risks and inaccuracies of these techniques. METHODS: Seventeen juvenile, open-chested pigs were studied before undergoing a separate cardiopulmonary bypass procedure. Live 3-D Doppler echocardiography images of the left ventricular outflow tract and aortic valve were obtained by epicardial scanning, using a Philips Medical Systems (Andover, Massachusetts) Sonos 7500 Live 3-D Echo system with a 2.5-MHz probe. Simultaneous CO measurements were obtained from an ultrasonic flow probe placed around the aortic root. Subsequent offline processing using custom software computed the CO from the digital 3-D Doppler DICOM data, and this was compared to the gold standard of the aortic flow probe measurements. RESULTS: One hundred forty-three individual CO measurements were taken from 16 pigs, one being excluded because of severe aortic regurgitation. There was good correlation between the 3-D Doppler and flow probe methods of CO measurement (y = 1.1x - 9.82, R(2) = 0.93). CONCLUSIONS: In this acute animal preparation, live 3-D Doppler echocardiographic data allowed for accurate assessment of CO as compared to the ultrasonic flow probe measurement.


Assuntos
Débito Cardíaco , Ecocardiografia Doppler em Cores , Ecocardiografia Tridimensional , Animais , Velocidade do Fluxo Sanguíneo , Ponte Cardiopulmonar , Estudos de Viabilidade , Humanos , Processamento de Imagem Assistida por Computador , Modelos Animais , Reprodutibilidade dos Testes , Suínos