Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 85
Filtrar
1.
Cardiovasc Revasc Med ; 64: 7-14, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38448258

RESUMO

BACKGROUND: Left atrial appendage (LAA) occluder embolization is an infrequent but serious complication. OBJECTIVES: We aim to describe timing, management and clinical outcomes of device embolization in a multi-center registry. METHODS: Patient characteristics, imaging findings and procedure and follow-up data were collected retrospectively. Device embolizations were categorized according to 1) timing 2) management and 3) clinical outcomes. RESULTS: Sixty-seven centers contributed data. Device embolization occurred in 108 patients. In 70.4 % of cases, it happened within the first 24 h of the procedure. The device was purposefully left in the LA and the aorta in two (1.9 %) patients, an initial percutaneous retrieval was attempted in 81 (75.0 %) and surgery without prior percutaneous retrieval attempt was performed in 23 (21.3 %) patients. Two patients died before a retrieval attempt could be made. In 28/81 (34.6 %) patients with an initial percutaneous retrieval attempt a second, additional attempt was performed, which was associated with a high mortality (death in patients with one attempt: 2.9 % vs. second attempt: 21.4 %, p < 0.001). The primary outcome (bailout surgery, cardiogenic shock, stroke, TIA, and/or death) occurred in 47 (43.5 %) patients. Other major complications related to device embolization occurred in 21 (19.4 %) patients. CONCLUSIONS: The majority of device embolizations after LAA closure occurs early. A percutaneous approach is often the preferred method for a first rescue attempt. Major adverse event rates, including death, are high particularly if the first retrieval attempt was unsuccessful. CONDENSED ABSTRACT: This dedicated multicenter registry examined timing, management, and clinical outcome of device embolization. Early embolization (70.4 %) was most frequent. As a first rescue attempt, percutaneous retrieval was preferred in 75.0 %, followed by surgical removal (21.3 %). In patients with a second retrieval attempt a higher mortality (death first attempt: 2.9 % vs. death second attempt: 24.1 %, p < 0.001) was observed. Mortality (10.2 %) and the major complication rate after device embolization were high.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Cateterismo Cardíaco , Remoção de Dispositivo , Sistema de Registros , Humanos , Masculino , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/fisiopatologia , Feminino , Idoso , Estudos Retrospectivos , Resultado do Tratamento , Fatores de Tempo , Idoso de 80 Anos ou mais , Fatores de Risco , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/mortalidade , Fibrilação Atrial/terapia , Fibrilação Atrial/mortalidade , Remoção de Dispositivo/efeitos adversos , Embolia/etiologia , Embolia/mortalidade , Pessoa de Meia-Idade , Dispositivo para Oclusão Septal , Oclusão do Apêndice Atrial Esquerdo
2.
J Clin Med ; 12(23)2023 Nov 24.
Artigo em Inglês | MEDLINE | ID: mdl-38068344

RESUMO

Over the past two decades, percutaneous left atrial appendage occlusion (LAAO) has proven to be a viable alternative to oral anticoagulation (OAC) for stroke prevention in patients with atrial fibrillation (AF), in particular in those patients who are at increased risk for stroke and bleeding complications. This systematic review provides a comprehensive evaluation of anatomical features, patient selection, procedural planning and execution, complications, medical treatment following the procedure, and contemporary outcome data.

3.
Front Cardiovasc Med ; 10: 974527, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37252124

RESUMO

Objectives: Several studies have shown the potential advantage of less-invasive surgery (LIS) for left ventricular assist device (LVAD) implantation. This study aims to determine the impact of LIS on stroke and pump thrombosis events after LVAD implantation. Methods: Between January 2015 and March 2021, 335 consecutive patients underwent LVAD implantation using either conventional sternotomy (CS) or the LIS technique. Patient characteristics was prospectively collected. All patients were followed up until October 2021. Logistic multivariate regression and propensity-matched analyses were performed to account for confounding factors. Results: A total of 242 patients (F = 32; 13.0%) underwent LVAD implantation with CS and 93 patients (F = 8; 8.6%) with the LIS approach. Propensity matching generated two groups, including 98 patients in the CS group and 67 in the LIS group. Intensive care unit stay for the LIS group patients was significantly shorter than that for the CS group patients [2 (IQR: 2-5) days vs. 4 (IQR: 2-12) days, p < 0.01]. There were no significant differences in the incidence of stroke events (14% in CS vs. 16% in the LIS group; p = 0.6) or in pump thrombosis (6.1% in CS vs. 7.5% in the LIS group; p = 0.8) between the groups. The hospital mortality rate in the matched cohort was significantly lower in the LIS group (7.5% vs. 19%; p = 0.03). However, the 1-year mortality rate showed no significant difference between both groups (24.5% in CS and 17.9% in LIS; p = 0.35). Conclusions: The LIS approach for LVAD implantation is a safe procedure with potential advantage in the early postoperative period. However, the LIS approach remains comparable to the sternotomy approach in terms of postoperative stroke, pump thrombosis, and outcome.

4.
Europace ; 25(3): 914-921, 2023 03 30.
Artigo em Inglês | MEDLINE | ID: mdl-36734247

RESUMO

AIMS: The FLXibility Post-Approval Study collected data on unselected patients implanted with a WATCHMAN FLX in a commercial clinical setting. METHODS AND RESULTS: Patients were implanted with a WATCHMAN FLX per local standard of care, with a subsequent first follow-up visit from 45 to 120 days post-implant and a final follow-up at 1-year post-procedure. A Clinical Event Committee adjudicated all major adverse events and TEE/CT imaging results were adjudicated by a core laboratory. Among 300 patients enrolled at 17 centres in Europe, the mean age was 74.6 ± 8.0 years, mean CHA2DS2-VASc score was 4.3 ± 1.6, and 62.1% were male. The device was successfully implanted in 99.0% (297/300) of patients. The post-implant medication regimen was DAPT for 87.3% (262/300). At first follow-up, core-lab adjudicated complete seal was 88.2% (149/169), 9.5% (16/169) had leak <3 mm, 2.4 (4/169) had leak ≥3 mm to ≤5 mm, and 0% had >5 mm leak. At 1 year, 93.3% (280/300) had final follow-up; 60.5% of patients were on a single antiplatelet medication, 21.4% were on DAPT, 5.6% were on direct oral anticoagulation, and 12.1% were not taking any antiplatelet/anticoagulation medication. Adverse event rates through 1 year were: all-cause death 10.8% (32/295); CV/unexplained death 5.1% (15/295); disabling and non-disabling stroke each 1.0% (3/295, all non-fatal); pericardial effusion requiring surgery or pericardiocentesis 1.0% (3/295); and device-related thrombus 2.4% (7/295). CONCLUSION: The WATCHMAN FLX device had excellent procedural success rates, high LAA seal rates, and low rates of thromboembolic events in everyday clinical practice.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Acidente Vascular Cerebral , Humanos , Masculino , Idoso , Idoso de 80 Anos ou mais , Feminino , Inibidores da Agregação Plaquetária/uso terapêutico , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Resultado do Tratamento , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/complicações , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Anticoagulantes/efeitos adversos , Cateterismo Cardíaco/efeitos adversos , Ecocardiografia Transesofagiana
5.
Catheter Cardiovasc Interv ; 101(3): 610-619, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36682074

RESUMO

BACKGROUND: Left atrial appendage closure (LAAC) has emerged as an alternative to oral anticoagulation (OAC) for stroke prevention in patients with atrial fibrillation (AF). OAC treatment has been proven feasible in mild-to-moderate chronic kidney disease (CKD). In contrast, the optimal antithrombotic management of AF patients with end-stage renal disease (ESRD) is unknown and LAAC has not been proven in these patients in prospective randomized clinical trials. OBJECTIVES: The objective of this study is to evaluate safety and efficacy of LAAC in patients with ESRD. METHODS: Patients undergoing LAAC were collected in a German multicenter real-world observational registry. A composite endpoint consisting of the occurrence of ischemic stroke/transient ischemic attack, systemic embolism, and/or major clinical bleeding was assessed. Patients with ESRD were compared with propensity score-matched patients without severe CKD. ESRD was defined as a glomerular filtration rate < 15 ml/min/1.73 m2 or chronic hemodialysis treatment. RESULTS: A total of 604 patients were analyzed, including 57 with ESRD and 57 propensity-matched patients. Overall, 596 endocardial and 8 epicardial LAAC procedures were performed. Frequency of major complications was 7.0% (42/604 patients) in the overall cohort, 8.8% (5/57 patients) in patients with ESRD, and 10.5% (6/57 patients) in matched controls (p = 0.75). The estimated event-free survival of the combined endpoint after 500 days was 90.7 ± 4.5% in patients with ESRD and 90.2 ± 5.5% in matched controls (p = 0.33). CONCLUSIONS: LAAC had comparable procedural safety and clinical efficacy in patients with ESRD and patients without severe CKD.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Falência Renal Crônica , Insuficiência Renal Crônica , Acidente Vascular Cerebral , Humanos , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Resultado do Tratamento , Apêndice Atrial/diagnóstico por imagem , Estudos Prospectivos , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/terapia , Falência Renal Crônica/complicações , Falência Renal Crônica/diagnóstico , Falência Renal Crônica/terapia , Insuficiência Renal Crônica/complicações , Insuficiência Renal Crônica/diagnóstico , Insuficiência Renal Crônica/terapia , Diálise Renal/efeitos adversos , Sistema de Registros , Anticoagulantes/efeitos adversos
6.
EuroIntervention ; 18(9): 759-768, 2022 Oct 21.
Artigo em Inglês | MEDLINE | ID: mdl-35942626

RESUMO

BACKGROUND: Left ventricular outflow tract (LVOT) calcification has been associated with worse outcomes in patients undergoing transcatheter aortic valve implantation (TAVI) and may influence the selection of prosthetic valve type. AIMS: We aimed to evaluate the impact of LVOT calcification on outcomes after TAVI with a self-expanding valve (SEV) versus a balloon-expandable valve (BEV). METHODS: Patients of the SOLVE-TAVI trial, randomised to Edwards SAPIEN 3 or Medtronic Evolut R, were divided according to LVOT calcification into no/mild (≤1 calcium nodule extending <5 mm and covering <10% of the LVOT perimeter) and moderate/severe LVOT calcification groups. The primary endpoint was a composite of death, stroke, moderate/severe paravalvular regurgitation, permanent pacemaker implantation and annulus rupture at 30 days. Additional endpoints included all-cause and cardiovascular mortality at 1 year. RESULTS: Out of 416 eligible patients, moderate/severe LVOT calcification was present in 143 (34.4%). Moderate/severe LVOT calcification was associated with significantly longer fluoroscopy time and higher rates of pre- and post-dilation. Regardless of the LVOT calcification group, there was no significant difference in the primary endpoint associated with the valve type (no/mild LVOT calcification group: SEV 25.0% vs BEV 27.0%; hazard ratio [HR] 1.10, 95% confidence interval [95% CI]: 0.68-1.73; p=0.73 and moderate/severe LVOT calcification group: SEV 25.0% vs BEV 19.4%; HR 0.76, 95% CI: 0.38-1.61; p=0.49), no significant interaction between LVOT calcification and valve type (pint=0.29) and no differences between SEV vs BEV within LVOT calcification groups regarding 1-year all-cause and cardiovascular mortality. CONCLUSIONS: Moderate/severe LVOT calcification was associated with longer fluoroscopy time and an increased need for pre- and post-dilation, but not with a higher incidence of early and mid-term adverse clinical outcomes, regardless of valve type. (ClinicalTrials.gov: NCT02737150).


Assuntos
Estenose da Valva Aórtica , Calcinose , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Valva Aórtica/cirurgia , Cálcio , Tomografia Computadorizada Multidetectores , Fluoroscopia , Resultado do Tratamento , Desenho de Prótese
7.
J Clin Med ; 11(5)2022 Feb 25.
Artigo em Inglês | MEDLINE | ID: mdl-35268347

RESUMO

Mortality in infarct-related cardiogenic shock (CS) remains high, reaching 40-50%. In refractory CS, active mechanical circulatory support devices including veno-arterial extracorporeal membrane oxygenation (VA-ECMO) are rapidly evolving. However, supporting evidence of VA-ECMO therapy in infarct-related CS is low. The current review aims to give an overview on the basics of VA-ECMO therapy, current evidence, ongoing trials, patient selection and potential complications.

8.
Cardiovasc Revasc Med ; 37: 34-40, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-34257057

RESUMO

BACKGROUND: Vascular and bleeding complications are common after transcatheter aortic valve implantation (TAVI) and are associated with worse outcomes. The plug-based Manta (M) vascular closure device (VCD) is a novel option to achieve haemostasis for large-bore arterial access sites. OBJECTIVE: We aimed to compare vascular and bleeding complications between the M-VCD and the established suture-based Perclose ProGlide (P)-VCD. METHODS: From February to September 2019 a total of 578 patients underwent transfemoral TAVI at a single high-volume centre. Access site closure was performed using M-VCD in 195 patients (33.7%) and P-VCD in 383 patients (66.3%). We assessed vascular and access site-related complications as well as bleeding events according to the Valve Academic Research Consortium-2 definition. RESULTS: Overall vascular complications occurred less frequently in the M-VCD group (10.7% vs. 19.0%, p = 0.011) driven by a significantly lower rate of major vascular events (2.0% vs. 6.5%, p = 0.025). Access site-related complications were significantly less frequent in the M-VCD cohort (10.7% vs. 16.6%, p = 0.048). The M-VCD was associated with significantly lower rates of major (0.5% vs. 4.4%, p = 0.009) and life-threatening bleeding (0% vs. 2.3%, p = 0.032). In multivariable analysis, the use of M-VCD was the only independent predictor of vascular complications (odds ratio 0.54, 95% confidence interval 0.32-0.91, p = 0.022). CONCLUSIONS: The M-VCD was associated with a reduction of vascular and access-site complications as well as severe bleeding after transfemoral TAVI compared to the P-VCD in this observational study.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Dispositivos de Oclusão Vascular , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/cirurgia , Hemorragia/etiologia , Técnicas Hemostáticas/efeitos adversos , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
10.
Circulation ; 145(3): 170-183, 2022 01 18.
Artigo em Inglês | MEDLINE | ID: mdl-34738828

RESUMO

BACKGROUND: Transcatheter aortic valve replacement is an established treatment option for patients with severe symptomatic aortic stenosis and is most commonly performed through the transfemoral access route. Percutaneous access site closure can be achieved using dedicated plug-based or suture-based vascular closure device (VCD) strategies, but randomized comparative studies are scarce. METHODS: The CHOICE-CLOSURE trial (Randomized Comparison of Catheter-based Strategies for Interventional Access Site Closure during Transfemoral Transcatheter Aortic Valve Implantation) is an investigator-initiated, multicenter study, in which patients undergoing transfemoral transcatheter aortic valve replacement were randomly assigned to vascular access site closure using either a pure plug-based technique (MANTA, Teleflex) with no additional VCDs or a primary suture-based technique (ProGlide, Abbott Vascular) potentially complemented by a small plug. The primary end point consisted of access site- or access-related major and minor vascular complications during index hospitalization, defined according to the Valve Academic Research Consortium-2 criteria. Secondary end points included the rate of access site- or access-related bleeding, VCD failure, and time to hemostasis. RESULTS: A total of 516 patients were included and randomly assigned. The mean age of the study population was 80.5±6.1 years, 55.4% were male, 7.6% of patients had peripheral vascular disease, and the mean Society of Thoracic Surgeons score was 4.1±2.9%. The primary end point occurred in 19.4% (50/258) of the pure plug-based group and 12.0% (31/258) of the primary suture-based group (relative risk, 1.61 [95% CI, 1.07-2.44], P=0.029). Access site- or access-related bleeding occurred in 11.6% versus 7.4% (relative risk, 1.58 [95%CI: 0.91-2.73], P=0.133) and device failure in 4.7% versus 5.4% (relative risk, 0.86, [95% CI, 0.40-1.82], P=0.841) in the respective groups. Time to hemostasis was significantly shorter in the pure plug-based group (80 [32-180] versus 240 [174-316] seconds, P<0.001). CONCLUSIONS: Among patients treated with transfemoral transcatheter aortic valve replacement, a pure plug-based vascular closure technique using the MANTA VCD is associated with a higher rate of access site- or access-related vascular complications but a shorter time to hemostasis compared with a primary suture-based technique using the ProGlide VCD. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT04459208.


Assuntos
Estenose da Valva Aórtica/cirurgia , Doenças Vasculares Periféricas/cirurgia , Substituição da Valva Aórtica Transcateter , Dispositivos de Oclusão Vascular , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Artéria Femoral/cirurgia , Hemorragia/etiologia , Hemostasia/fisiologia , Humanos , Masculino , Suturas/efeitos adversos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Dispositivos de Oclusão Vascular/efeitos adversos
11.
JACC Cardiovasc Interv ; 14(24): 2685-2694, 2021 12 27.
Artigo em Inglês | MEDLINE | ID: mdl-34949392

RESUMO

OBJECTIVES: The authors investigated whether iatrogenic atrial septal defect (iASD) closure post-transcatheter mitral valve edge-to-edge repair (TMVR) is superior to conservative therapy (CT) and whether outcomes (death/heart failure [HF] hospitalization) differ between patients with and without an iASD post-TMVR. BACKGROUND: Transseptal access for TMVR can create an iASD, which is associated with impaired outcomes. Controversially, the creation of an iASD in HF has been linked to improved hemodynamics. METHODS: 80 patients with an iASD and relevant left-to-right shunting (Qp:Qs ≥1.3) 30 days following TMVR were randomized to CT or interventional closure of the iASD (MITHRAS [Closure of Iatrogenic Atrial Septal Defect Following Transcatheter Mitral Valve Repair] cohort), and 235 patients without an iASD served as a comparative cohort. RESULTS: All patients of the MITHRAS cohort (mean age 77 ± 9 years, 39% women) received their allocated treatment, and follow-up was completed for all MITHRAS and comparative cohort (mean age 77 ± 8 years, 47% women) patients. Twelve months post-TMVR, there was no significant difference in the combined endpoint of death or HF hospitalization within the MITHRAS cohort (iASD closure: 35% vs CT 50%; P = 0.26). The combined endpoint was more frequent among patients within the MITHRAS cohort as opposed to the comparative cohort (43% vs 17%; P < 0.0001), primarily driven by a higher rate of HF hospitalization (34% vs 8%; P = 0.004). CONCLUSIONS: In this randomized controlled trial, interventional closure of a relevant iASD 1 month after TMVR did not result in improved clinical outcomes at 12 months post-TMVR. Patients with an iASD are at higher risk for HF hospitalization independent of iASD management and warrant close follow-up. (Closure of Iatrogenic Atrial Septal Defect Following Transcatheter Mitral Valve Repair [MITHRAS]; NCT03024268).


Assuntos
Comunicação Interatrial , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Idoso , Idoso de 80 Anos ou mais , Cateterismo Cardíaco/efeitos adversos , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Doença Iatrogênica , Masculino , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Resultado do Tratamento
13.
J Invasive Cardiol ; 33(5): E329-E335, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33932279

RESUMO

OBJECTIVES: Despite increasing use of veno-arterial extracorporeal membrane oxygenation (VA-ECMO) in patients with cardiogenic shock (CS) secondary to ST-segment elevation myocardial infarction (STEMI), a paucity of adequate evidence for this therapy remains. The aim of this single-center clinical registry study was to identify predictors of survival and discern the possible optimal time to initiate VA-ECMO in this cohort. METHODS AND RESULTS: Seventy-nine consecutive patients with CS complicating STEMI who received VA-ECMO support were included in this analysis. The primary endpoint was survival at 6 months after initiation of VA-ECMO. Mean age was 60 ± 11 years. Forty-six patients (58%) were successfully weaned from VA-ECMO and 30 patients (38%) could be discharged. Of these, 23 patients (29% of the overall population) survived up to 6-month follow-up. Multivariate analysis to identify determinants of survival showed no association between the time of CS onset to VA-ECMO start time and 6-month survival (P=.75). Glomerular filtration rate on admission (P<.001), white blood cell count on admission (P≤.01), age (P≤.01), and arterial lactate level 1 and 24 hours after VA-ECMO initiation (P=.01) were the strongest predictors of survival. CONCLUSIONS: The timing of VA-ECMO initiation in patients with CS complicating STEMI was not a prognostic factor of survival. Renal function, white blood cell count, age, and lactate level were the strongest predictors of death during 6-month follow-up.


Assuntos
Oxigenação por Membrana Extracorpórea , Infarto do Miocárdio com Supradesnível do Segmento ST , Humanos , Pessoa de Meia-Idade , Sistema de Registros , Estudos Retrospectivos , Infarto do Miocárdio com Supradesnível do Segmento ST/complicações , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico , Infarto do Miocárdio com Supradesnível do Segmento ST/terapia , Choque Cardiogênico/diagnóstico , Choque Cardiogênico/etiologia , Choque Cardiogênico/terapia
14.
J Am Coll Cardiol ; 77(17): 2204-2215, 2021 05 04.
Artigo em Inglês | MEDLINE | ID: mdl-33926657

RESUMO

BACKGROUND: The randomized SOLVE-TAVI (compariSon of secOnd-generation seLf-expandable vs. balloon-expandable Valves and gEneral vs. local anesthesia in Transcatheter Aortic Valve Implantation) trial compared newer-generation self-expanding valves (SEV) and balloon-expandable valves (BEV) as well as local anesthesia with conscious sedation (CS) and general anesthesia (GA) in patients undergoing transfemoral transcatheter aortic valve replacement (TAVR). Both strategies showed similar outcomes at 30 days. OBJECTIVES: The purpose of this study was to compare clinical outcomes during 1-year follow-up in the randomized SOLVE-TAVI trial. METHODS: Using a 2 × 2 factorial design 447 intermediate- to high-risk patients with severe, symptomatic aortic stenosis were randomly assigned to transfemoral TAVR using either the SEV (Evolut R, Medtronic Inc., Minneapolis, Minnesota) or the BEV (Sapien 3, Edwards Lifesciences, Irvine, California) as well as CS or GA at 7 sites. RESULTS: In the valve-comparison strategy, rates of the combined endpoint of all-cause mortality, stroke, moderate or severe paravalvular leakage, and permanent pacemaker implantation were similar between the BEV and SEV group (n = 84, 38.3% vs. n = 87, 40.4%; hazard ratio: 0.94; 95% confidence interval: 0.70 to 1.26; p = 0.66) at 1 year. Regarding the anesthesia comparison, the combined endpoint of all-cause mortality, stroke, myocardial infarction, and acute kidney injury occurred with similar rates in the GA and CS groups (n = 61, 25.7% vs. n = 54, 23.8%; hazard ratio: 1.09; 95% confidence interval: 0.76 to 1.57; p = 0.63). CONCLUSIONS: In intermediate- to high-risk patients undergoing transfemoral TAVR, newer-generation SEV and BEV as well as CS and GA showed similar clinical outcomes at 1 year using a combined clinical endpoint. (SecOnd-generation seLf-expandable Versus Balloon-expandable Valves and gEneral Versus Local Anesthesia in TAVI [SOLVE-TAVI]; NCT02737150).


Assuntos
Anestesia/métodos , Estenose da Valva Aórtica/cirurgia , Complicações Pós-Operatórias/epidemiologia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Alemanha/epidemiologia , Humanos , Incidência , Masculino , Resultado do Tratamento
16.
JACC Cardiovasc Interv ; 14(1): 54-66, 2021 01 11.
Artigo em Inglês | MEDLINE | ID: mdl-33413865

RESUMO

OBJECTIVES: The study sought to assess the acute hemodynamic effects of iatrogenic atrial septal defect (iASD) closure following transcatheter mitral valve edge-to-edge repair (TMVR). BACKGROUND: The potential hemodynamic and clinical consequences of an iASD following TMVR are currently subject to controversial debates. METHODS: In 21 patients with relevant left-to-right shunt flow (50% [IQR: 38% to 60%] of systemic perfusion volume) across an iASD following TMVR, interventional closure was performed with recordings of left ventricular (LV) and right ventricular (RV) pressure-volume loops during iASD occlusion. RESULTS: iASD occlusion led to a volume shift from the RV (RV end-diastolic volume index: pre 102 [IQR: 80 to 120] ml/m2, post 92 [IQR: 70 to 111] ml/m2; p < 0.001) to the LV (LV end-diastolic volume index: pre 91 [IQR: 74 to 124] ml/m2, post 97 [IQR: 77 to 127] ml/m2; p < 0.001) with reduced RV (3.49 [IQR: 2.07 to 3.58] l/min/m2 vs. 2.68 [IQR: 2.07 to 3.58] l/min/m2; p < 0.001) but increased LV cardiac index (2.25 [IQR: 1.80 to 3.28] l/min/m2 vs. 2.77 [IQR: 1.90 to 3.34] l/min/m2; p = 0.039). Although RV end-diastolic pressure decreased (pre 5.0 [IQR: 4.0 to 8.5] mm Hg, post 4.5 [IQR: 3.0 to 8.3] mm Hg; p = 0.024), LV end-diastolic pressure remained unchanged (pre 11.0 [IQR: 9.5 to 14.0] mm Hg, post 13.0 [IQR: 9.0 to 15.5] mm Hg; p = 0.142). LV transmural pressure increased (7.0 [IQR: 4.0 to 11.0] mm Hg vs. 11.0 [IQR: 7.0 to 15.0] mm Hg; p = 0.001) and LV eccentricity index decreased (p < 0.001). The change in LV transmural pressure correlated significantly with the change in LV-to-RV end-diastolic volume ratio (r = 0.674; p = 0.018). Right heart failure symptoms declined at 1-month follow-up (71% vs. 35%; p = 0.003) as did New York Heart Association functional class (≥III: 48% vs. 25%; p < 0.001). CONCLUSIONS: iASD closure following TMVR leads to a volume shift from the RV to the LV with reduced pulmonary but increased systemic cardiac index and with favorable biventricular interaction at maintained LV filling pressure, resulting in a decline in heart failure symptoms at 1-month follow-up.


Assuntos
Comunicação Interatrial , Insuficiência da Valva Mitral , Cateterismo Cardíaco , Humanos , Doença Iatrogênica , Valva Mitral , Resultado do Tratamento
17.
Am Heart J ; 232: 185-193, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33253678

RESUMO

BACKGROUND: The impact of coronary artery chronic total occlusion (CTO) and its management with percutaneous coronary intervention (PCI) in the setting of myocardial infarction (MI) related cardiogenic shock (CS) remains unclear. METHODS: This is a pre-specified analysis from the culprit-lesion-only PCI vs multivessel PCI in CS (CULPRIT-SHOCK) trial which randomized patients presenting with MI and multivessel disease complicated by CS to a culprit-lesion-only or immediate multivessel PCI strategy. CTO was defined by central core-laboratory evaluation. The independent associations between the presence of CTO and adverse outcomes at 30 days and 1 year were assessed using multivariate logistics models. RESULTS: A noninfarct related CTO was present in 157 of 667 (23.5%) analyzed patients. Patients presenting with CTO had more frequent diabetes mellitus or prior PCI but less frequently presented with ST segment elevation MI as index event. The presence of CTO was associated with higher rate of death at 30 days (adjusted Odds ratio 1.63; 95% confidence interval [CI] 1.01-2.60). Rate of death at 1 year was also increased but did not reach statistical significance (adjusted Odds ratio 1.62; 95%CI 0.99-2.66). Compare to immediate multivessel PCI, a strategy of culprit-lesion-only PCI was associated with lower rates of death or renal replacement therapy at 30 days in patients with and without CTO (Odds ratio 0.79 95%CI 0.42-1.49 and Odds ratio 0.67 95%CI 0.48-0.96, respectively), without significant interaction (P = .68). CONCLUSIONS: In patients with MI-related CS and multivessel disease, the presence of CTO is associated with adverse outcomes while a strategy of culprit-lesion-only PCI seems beneficial regardless of the presence of CTO.


Assuntos
Oclusão Coronária/cirurgia , Estenose Coronária/cirurgia , Infarto do Miocárdio/cirurgia , Intervenção Coronária Percutânea/métodos , Choque Cardiogênico/terapia , Idoso , Idoso de 80 Anos ou mais , Causas de Morte , Doença Crônica , Oclusão Coronária/complicações , Estenose Coronária/complicações , Feminino , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Mortalidade , Análise Multivariada , Infarto do Miocárdio/complicações , Prognóstico , Terapia de Substituição Renal/estatística & dados numéricos , Choque Cardiogênico/etiologia , Resultado do Tratamento
19.
JACC Cardiovasc Interv ; 13(23): 2732-2741, 2020 12 14.
Artigo em Inglês | MEDLINE | ID: mdl-33189641

RESUMO

OBJECTIVES: This study sought to report early experience with the new-generation Watchman FLX device (Boston Scientific, Marlborough, Massachusetts). BACKGROUND: The new-generation Watchman FLX features a reduced height, improved anchoring and fabric coverage, and a closed distal end. These design modifications aim to simplify implantation, allow full recapture and repositioning, and reduce peridevice leak and device-related thrombosis. METHODS: A total of 165 patients undergoing left atrial appendage (LAA) occlusion (LAAO) with Watchman FLX were enrolled in a prospective, multicenter registry at 12 centers participating in the European limited market release program. RESULTS: Mean age was 75.4 ± 8.9 years, and CHA2DS2-VASc score 4.4 ± 1.4. A total of 128 patients (77.6%) had a history of major bleeding, including previous intracranial hemorrhage in 55 cases (33.3%). LAA landing zone minimal and maximal mean diameters were 19.1 ± 3.6 mm and 22.3 ± 3.7 mm, and 24.2% of LAA were considered complex by dimensions. Technical success was achieved in all patients. Successful implantation at first attempt was achieved in 129 cases (78.2%), and a second device was required in 6 cases (3.6%). Procedure-related complications occurred in 3 patients (1.8%): 2 access-related (1.2%) and 1 pericardial effusion (0.6%). No peri-procedural strokes, deaths, or device embolizations occurred. Forty-nine patients (29.7%) were discharged with single antiplatelet therapy, 105 (63.6%) on dual antiplatelet, and 11 (6.7%) on anticoagulation. Imaging follow-up displayed just 1 peridevice leak ≥5 mm and 7 cases of device-related thrombosis (4.7%). During a median follow-up of 55 days (interquartile range: 45 to 148 days), there were 6 hemorrhagic complications (4.8%), 1 patient (0.8%) had an ischemic stroke, and 1 (0.8%) died. No late device embolizations occurred. CONCLUSIONS: LAAO with the Watchman FLX is safe and effective in a wide range of LAA morphologies, with a low procedural complication rate, high degree of LAA sealing, and favorable short-term efficacy.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Idoso , Idoso de 80 Anos ou mais , Boston , Cateterismo Cardíaco , Humanos , Estudos Prospectivos , Acidente Vascular Cerebral , Resultado do Tratamento
20.
Circulation ; 142(22): 2095-2106, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-33032450

RESUMO

BACKGROUND: Venoarterial extracorporeal membrane oxygenation (VA-ECMO) is increasingly used to treat cardiogenic shock. However, VA-ECMO might hamper myocardial recovery. The Impella unloads the left ventricle. This study aimed to evaluate whether left ventricular unloading in patients with cardiogenic shock treated with VA-ECMO was associated with lower mortality. METHODS: Data from 686 consecutive patients with cardiogenic shock treated with VA-ECMO with or without left ventricular unloading using an Impella at 16 tertiary care centers in 4 countries were collected. The association between left ventricular unloading and 30-day mortality was assessed by Cox regression models in a 1:1 propensity score-matched cohort. RESULTS: Left ventricular unloading was used in 337 of the 686 patients (49%). After matching, 255 patients with left ventricular unloading were compared with 255 patients without left ventricular unloading. In the matched cohort, left ventricular unloading was associated with lower 30-day mortality (hazard ratio, 0.79 [95% CI, 0.63-0.98]; P=0.03) without differences in various subgroups. Complications occurred more frequently in patients with left ventricular unloading: severe bleeding in 98 (38.4%) versus 45 (17.9%), access site-related ischemia in 55 (21.6%) versus 31 (12.3%), abdominal compartment in 23 (9.4%) versus 9 (3.7%), and renal replacement therapy in 148 (58.5%) versus 99 (39.1%). CONCLUSIONS: In this international, multicenter cohort study, left ventricular unloading was associated with lower mortality in patients with cardiogenic shock treated with VA-ECMO, despite higher complication rates. These findings support use of left ventricular unloading in patients with cardiogenic shock treated with VA-ECMO and call for further validation, ideally in a randomized, controlled trial.


Assuntos
Oxigenação por Membrana Extracorpórea/mortalidade , Internacionalidade , Choque Cardiogênico/mortalidade , Choque Cardiogênico/terapia , Função Ventricular Esquerda/fisiologia , Adulto , Idoso , Estudos de Coortes , Oxigenação por Membrana Extracorpórea/tendências , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Mortalidade/tendências , Choque Cardiogênico/diagnóstico , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...