Pathol Res Pract ; 263: 155600, 2024 Sep 24.
Artigo em Inglês | MEDLINE | ID: mdl-39326364

RESUMO

Rapidly progressing ALL, a potentially fatal disease, demands timely diagnosis and treatment. On the other hand, spontaneous remission/regression (SR) is reported in various cancers including aggressive tumors like ALL. Infection or trauma-mediated immune system activation is assumed to cause SR, with the duration in cases of ALL typically being short. Indolent T-lymphoblastic proliferation (i-TLP) exhibits the uniform proliferation of TdT-positive T-cells, despite being a non-neoplastic disease, underscoring the significance of distinguishing it from T-cell acute lymphoblastic leukemia (T-ALL). i-TLP is expected to gain wider recognition and further advancements in understanding its pathology. Here, we present the case of a 59-year-old woman with T-ALL characterized by cycles of progression and SR followed by a rapid blast proliferation. This is the first reported case of T-ALL with repeated SR for more than one year, making this case an extremely rare clinical presentation. This challenging case will enhance comprehension of T-cell tumor pathogenesis.

3.
J Appl Clin Med Phys ; 25(8): e14381, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38696715

RESUMO

BACKGROUND: Surface-guided radiotherapy (SGRT) is adopted by several institutions; however, reports on the phantoms used to assess the precision of the SGRT setup are limited. PURPOSE: The purpose of this study was to develop a phantom to verify the accuracy of the irradiation position during skin mark-less SGRT. METHODS: An acrylonitrile butadiene styrene (ABS) plastic cube phantom with a diameter of 150 mm on each side containing a dummy target of 15 mm and two types of body surface-shaped phantoms (breast/face shape) that could be attached to the cube phantom were fabricated. Films can be inserted on four sides of the cubic phantom (left, right, anterior and posterior), and the center of radiation can be calculated by irradiating the dummy target with orthogonal MV beams. Three types of SGRT using a VOXELAN-HEV600M (Electronics Research&Development Corporation, Okayama, Japan) were evaluated using this phantom: (i) SGRTCT-a SGRT set-up based solely on a computed tomography (CT)-reference image. (ii) SGRTCT + CBCT-a method where cone beam computed tomography (CBCT) matching was performed after SGRTCT. (iii) SGRTScan-a resetup technique using a scan reference image obtained after completing the (ii) step. RESULTS: Both the breast and face phantoms were recognized in the SGRT system without problems. SGRTScan ensure precision within 1 mm/1° for breast and face verification, respectively. All SGRT methods showed comparable rotational accuracies with no significant disparities. CONCLUSIONS: The developed phantom was useful for verifying the accuracy of skin mark-less SGRT position matching. The SGRTScan demonstrated the feasibility of achieving skin-mark less SGRT with high accuracy, with deviations of less than 1 mm. Additional research is necessary to evaluate the suitability of the developed phantoms for use in various facilities and systems. This phantom could be used for postal surveys in the future.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Imagens de Fantasmas , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Radioterapia Guiada por Imagem , Humanos , Radioterapia Guiada por Imagem/métodos , Radioterapia Guiada por Imagem/instrumentação , Planejamento da Radioterapia Assistida por Computador/métodos , Tomografia Computadorizada de Feixe Cônico/métodos , Radioterapia de Intensidade Modulada/métodos , Pele/efeitos da radiação , Erros de Configuração em Radioterapia/prevenção & controle , Processamento de Imagem Assistida por Computador/métodos
4.
J Appl Clin Med Phys ; 25(7): e14322, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38436611

RESUMO

PURPOSE: Predicting recurrence following stereotactic body radiotherapy (SBRT) for non-small cell lung cancer provides important information for the feasibility of the individualized radiotherapy and allows to select the appropriate treatment strategy based on the risk of recurrence. In this study, we evaluated the performance of both machine learning models using positron emission tomography (PET) and computed tomography (CT) radiomic features for predicting recurrence after SBRT. METHODS: Planning CT and PET images of 82 non-small cell lung cancer patients who performed SBRT at our hospital were used. First, tumors were delineated on each CT and PET of each patient, and 111 unique radiomic features were extracted, respectively. Next, the 10 features were selected using three different feature selection algorithms, respectively. Recurrence prediction models based on the selected features and four different machine learning algorithms were developed, respectively. Finally, we compared the predictive performance of each model for each recurrence pattern using the mean area under the curve (AUC) calculated following the 0.632+ bootstrap method. RESULTS: The highest performance for local recurrence, regional lymph node metastasis, and distant metastasis were observed in models using Support vector machine with PET features (mean AUC = 0.646), Naive Bayes with PET features (mean AUC = 0.611), and Support vector machine with CT features (mean AUC = 0.645), respectively. CONCLUSIONS: We comprehensively evaluated the performance of prediction model developed for recurrence following SBRT. The model in this study would provide information to predict the recurrence pattern and assist in making treatment strategies.


Assuntos
Carcinoma Pulmonar de Células não Pequenas , Neoplasias Pulmonares , Aprendizado de Máquina , Radiocirurgia , Planejamento da Radioterapia Assistida por Computador , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Algoritmos , Carcinoma Pulmonar de Células não Pequenas/diagnóstico por imagem , Carcinoma Pulmonar de Células não Pequenas/radioterapia , Carcinoma Pulmonar de Células não Pequenas/cirurgia , Processamento de Imagem Assistida por Computador/métodos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/radioterapia , Neoplasias Pulmonares/cirurgia , Recidiva Local de Neoplasia/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Prognóstico , Radiômica , Radiocirurgia/métodos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Estudos Retrospectivos
5.
Technol Cancer Res Treat ; 23: 15330338241232557, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38378006

RESUMO

BACKGROUND: CyberKnife treatment for central lung tumors and mediastinal tumors can be difficult to perform with marker less. PURPOSE: We aimed to evaluate a novel tracheobronchial-based method (ie, tracheobronchial tracking) for the purpose of minimally invasive CyberKnife treatment for central lung and mediastinal tumors. METHODS: Five verification plans were created using an in-house phantom. Each plan included five irradiation sessions. The reference plan irradiated and tracked the simulated tumor (using the target tracking volume, TTV). Trachea plans tracked the simulated tracheo-bronchus and irradiated the simulated tumor and included two types of subplans: correlated plans in which the displacement of the simulated tracheobronchial and the simulated tumor were correlated, and non-correlated plans in which these factors were not correlated. Moreover, 15 mm and 25 mm TTVs were evaluated for each plan. The sin waveform and the patient's respiratory waveform were prepared as the respiratory model. Evaluations were performed by calculating the dose difference between the radiophotoluminescent glass dosimeter (RPLD)-generated mean dose values (generated by the treatment planning system, TPS) and the actual absorbed RPLD dose. Statistical analyses were performed to evaluate findings for each plan. Correlation and prediction errors were calculated for each axis of each plan using log files to evaluate tracking accuracy. RESULTS: Dose differences were statistically significant only in comparisons with the non-correlated plan. When evaluated using the sin waveform, the mean values for correlation and prediction errors in each axis and for all plans were less than 0.6 mm and 0.1 mm, respectively. In the same manner, they were less than 1.1 mm and 0.2 mm when evaluated using the patient's respiratory waveform. CONCLUSION: Our newly-developed tracheobronchial tracking method would be useful in facilitating minimally invasive CyberKnife treatment in certain cases of central lung and mediastinal tumors.


Assuntos
Neoplasias Pulmonares , Neoplasias do Mediastino , Radiocirurgia , Radioterapia de Intensidade Modulada , Humanos , Neoplasias do Mediastino/radioterapia , Neoplasias do Mediastino/cirurgia , Radiocirurgia/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Pulmão , Neoplasias Pulmonares/radioterapia , Neoplasias Pulmonares/cirurgia , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/métodos , Imagens de Fantasmas
6.
Thorac Cancer ; 14(35): 3445-3452, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37846145

RESUMO

BACKGROUND: The purpose of this study was to compare the dosimetric characteristics of five different treatment planning techniques for locally advanced non-small cell lung cancer (LA-NSCLC) with sequential plan changes. METHODS: A total of 13 stage III NSCLC patients were enrolled in this study. These patients had both computed tomography (CT) images for initial and boost treatment plans. The latter CT images were taken if tumor shrinkage was observed after 2 weeks of treatment. The prescription dose was 60 Gy/30 Fr (initial: 40 Gy/20 Fr, and boost: 20 Gy/10 Fr). Five techniques (forward-planed 3-dimensional conformal radiotherapy [F-3DCRT] on both CT images, inverse-planned 3DCRT [I-3DCRT] on both CT images, volumetric modulated arc therapy [VMAT] on both CT images, F-3DCRT on initial CT plus VMAT on boost CT [bVMAT], and hybrid of fixed intensity-modulated radiotherapy [IMRT] beams and VMAT beams on both CT images [hybrid]) were recalculated for all patients. The accumulated doses between initial and boost plans were compared among all treatment techniques. RESULTS: The conformity indexes (CI) of the planning target volume (PTV) of the five planning techniques were 0.34 ± 0.10, 0.57 ± 0.10, 0.86 ± 0.08, 0.61 ± 0.12, and 0.83 ± 0.11 for F-3DCRT, I-3DCRT, VMAT, bVMAT, and hybrid, respectively. In the same manner, lung volumes receiving >20 Gy (V20Gy ) were 21.05 ± 10.56%, 20.86 ± 6.45, 19.50 ± 7.38%, 19.98 ± 10.04%, and 17.74 ± 7.86%. There was significant improvement about CI and V20Gy for hybrid compared with F-3DCRT (p < 0.05). CONCLUSION: The IMRT/VMAT hybrid technique for LA-NSCLC patients improved target CI and reduced lung doses. Furthermore, if IMRT was not available initially, starting with 3DCRT might be beneficial as demonstrated in the bVMAT procedure of this study.


Assuntos
Carcinoma Pulmonar de Células não Pequenas , Neoplasias Pulmonares , Radioterapia Conformacional , Humanos , Carcinoma Pulmonar de Células não Pequenas/radioterapia , Carcinoma Pulmonar de Células não Pequenas/etiologia , Planejamento da Radioterapia Assistida por Computador/métodos , Dosagem Radioterapêutica , Neoplasias Pulmonares/radioterapia , Neoplasias Pulmonares/etiologia , Radioterapia Conformacional/métodos
7.
J Appl Clin Med Phys ; 24(12): e14142, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37672211

RESUMO

PURPOSE: This study aimed to compare fiducial markers used in CyberKnife treatment in terms of metal artifact intensity observed in CT images and fiducial recognition in the CyberKnife system affected by patient body thickness and type of marker. METHODS: Five markers, ACCULOC 0.9 mm × 3 mm, Ball type Gold Anchor (GA) 0.28 mm × 10 mm, 0.28 mm × 20 mm, and novel size GA 0.4 mm × 10 mm, 0.4 mm × 20 mm were evaluated. To evaluate metal artifacts of CT images, two types of CT images of water-equivalent gels with each marker were acquired using Aquilion LB CT scanner, one applied SEMAR (SEMAR-on) and the other did not apply this technique (SEMAR-off). The evaluation metric of artifact intensity (MSD ) which represents a variation of CT values were compared for each marker. Next, 5, 15, and 20 cm thickness of Tough Water (TW) was placed on the gel under the condition of overlapping the vertebral phantom in the Target Locating System, and the live image of each marker was acquired to compare fiducial recognition. RESULTS: The mean MSD of SEMAR-off was 78.80, 74.50, 97.25, 83.29, and 149.64 HU for ACCULOC, GA0.28 mm × 10 mm, 20 mm, and 0.40 mm × 10 mm, 20 mm, respectively. In the same manner, that of SEMAR-on was 23.52, 20.26, 26.76, 24.89, and 33.96 HU, respectively. Fiducial recognition decreased in the order of 5, 15, and 20 cm thickness, and GA 0.4 × 20 mm showed the best recognition at thickness of 20 cm TW. CONCLUSIONS: We demonstrated the potential to reduce metal artifacts in the CT image to the same level for all the markers we evaluated by applying SEMAR. Additionally, the fiducial recognition of each marker may vary depending on the thickness of the patient's body. Particularly, we showed that GA 0.40 × 20 mm may have more optimal recognition for CyberKnife treatment in cases of high bodily thickness in comparison to the other markers.


Assuntos
Marcadores Fiduciais , Radioterapia Guiada por Imagem , Humanos , Artefatos , Tomografia Computadorizada por Raios X/métodos , Radioterapia Guiada por Imagem/métodos , Ouro , Água , Algoritmos
8.
IJU Case Rep ; 6(4): 222-225, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37405027

RESUMO

Introduction: We present a case of mucinous adenocarcinoma of the prostate with testicular and lung metastases following robot-assisted radical prostatectomy, androgen deprivation therapy, and radiotherapy. Case presentation: A 73-year-old man with a prostate-specific antigen level of 4.3 ng/mL was diagnosed with prostate cancer. Following the robot-assisted radical prostatectomy, the pathological diagnosis was mucinous adenocarcinoma of the prostate (pT3bpN0, Gleason score of 4 + 4). Salvage hormonal therapy and irradiation were performed after the prostatectomy. Enlargement of the left testis was noted, and 28 months after prostatectomy, computed tomography detected a left testicular tumor and nodular lesions in the bilateral lungs. The histopathological diagnosis of left high orchiectomy was metastasis of a mucinous adenocarcinoma of the prostate. Chemotherapy with docetaxel followed by cabazitaxel was initiated. Conclusion: Mucinous prostate adenocarcinoma with distal metastases following prostatectomy has been managed for longer than 3 years with multiple treatments.

9.
Pancreatology ; 23(5): 537-542, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37301696

RESUMO

BACKGROUND: /Objectives: This study aimed to evaluate the usefulness of three-dimensional (3D) immunohistochemistry for the Ki67 index of small tissue specimens of pancreatic neuroendocrine tumor (PanNET). METHODS: Clinicopathological materials from 17 patients with PanNET who underwent surgical resection at Jichi Medical University Hospital were analyzed. We compared the Ki67 index of endoscopic ultrasonography-fine-needle aspiration biopsy (EUS-FNAB) specimens, surgical specimens, and small tissue specimens hollowed from paraffin blocks of surgical specimens that were substituted for EUS-FNAB specimens ("sub-FNAB"). The sub-FNAB specimens were optically cleared using LUCID (IlLUmination of Cleared organs to IDentify target molecules) and analyzed using 3D immunohistochemistry. RESULTS: The median Ki67 index in FNAB, sub-FNAB, and surgical specimens with conventional immunohistochemistry were 1.2% (0.7-5.0), 2.0% (0.5-14.6), and 5.4% (1.0-19.4), respectively. The median Ki67 index in sub-FNAB specimens with tissue clearing was calculated separately using the total number of cells on multiple images ("multiple slice"), with the image of the fewest positive cells ("coldspot"), and with the image of most positive cells ("hotspot"), which were 2.7% (0.2-8.2), 0.8% (0-4.8), and 5.5% (2.3-12.4), respectively. PanNET grade evaluated for the hotspot of the surgical specimens was significantly more consistent with those of the hotspot than multiple images of sub-FNAB specimens (16/17 vs. 10/17, p = 0.015). Hotspot evaluation using 3D immunohistochemistry of the sub-FNAB specimens showed agreement with the assessment of the surgical specimens (Kappa coefficient: 0.82). CONCLUSIONS: Tissue clearing and 3D immunohistochemistry for the Ki67 index can potentially improve the preoperative evaluation of EUS-FNAB specimens of PanNET in routine clinical practice.


Assuntos
Tumores Neuroendócrinos , Neoplasias Pancreáticas , Humanos , Antígeno Ki-67 , Tumores Neuroendócrinos/diagnóstico , Tumores Neuroendócrinos/cirurgia , Tumores Neuroendócrinos/patologia , Imuno-Histoquímica , Neoplasias Pancreáticas/cirurgia , Neoplasias Pancreáticas/patologia , Biópsia por Agulha Fina/métodos , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/métodos
10.
Radiol Phys Technol ; 16(2): 292-298, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37079253

RESUMO

To report the long-term quality assurance (QA) experience of an on-rail computed tomography (CT) system for image-guided radiotherapy using an in-house phantom. An on-rail CT system combining the Elekta Synergy and Canon Aquilion LB was used. The treatment couch was shared by the linear accelerators and CT, and the couch was rotated by 180° when using the on-rail-CT system to ensure that the CT direction was toward the head. All QA analyses were performed by radiation technologists on CBCT or on-rail CT images of the in-house phantom. The CBCT center accuracy from the linac laser, couch rotational accuracy (CBCT center vs. on-rail CT center), horizontal accuracy by CT gantry shift, and remote couch shift accuracy were evaluated. This study reported the QA status of the system during the period 2014-2021. The absolute mean accuracy of couch rotation was 0.4 ± 0.28 mm, 0.44 ± 0.36 mm, and 0.37 ± 0.27 mm in the SI, RL, and AP directions, respectively. Horizontal and remote movement accuracies of the treatment couch were also within 0.5 mm of the absolute mean value. A decrease in the accuracy of couch rotation was also observed due to aging deterioration of related parts caused by the frequent use of couch rotation. The three-dimensional accuracy of on-rail CT systems derived mainly from treatment couches can be maintained within 0.5 mm with appropriate accuracy assurance for at least > 8 years.


Assuntos
Radiocirurgia , Radioterapia Guiada por Imagem , Radioterapia Guiada por Imagem/métodos , Tomografia Computadorizada por Raios X/métodos , Tomógrafos Computadorizados , Aceleradores de Partículas , Imagens de Fantasmas , Planejamento da Radioterapia Assistida por Computador