1.
Data Brief ; 35: 106791, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33604423

RESUMO

The HANDS dataset has been created for human-robot interaction research, and it is composed of spatially and temporally aligned RGB and Depth frames. It contains 12 static single-hand gestures performed with both the right-hand and the left-hand, and 3 static two-hands gestures for a total of 29 unique classes. Five actors (two females and three males) have been acquired performing the gestures, each of them adopting a different background and light conditions. For each actor, 150 RGB frames and their corresponding 150 Depth frames per gesture have been collected, for a total of 2400 RGB frames and 2400 Depth frames per actor. Data has been collected using a Kinect v2 camera intrinsically calibrated to spatially align RGB data to Depth data. The temporal alignment has been performed offline using MATLAB, aligning frames with a maximum temporal distance of 66  ms. This dataset has been used in [1] and it is freely available at http://dx.doi.org/10.17632/ndrczc35bt.1.

2.
J Hypertens ; 36(5): 1154-1163, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29578964

RESUMO

BACKGROUND: The evaluation of the morphological characteristics of small resistance arteries in humans is challenging. The gold standard method is generally considered to be the measurement by wire or pressure micromyography of the media-to-lumen ratio of subcutaneous small vessels obtained by local biopsies. However, noninvasive techniques for the evaluation of retinal arterioles were recently proposed; in particular, two approaches, scanning laser Doppler flowmetry (SLDF) and adaptive optics, seem to provide useful information; both of them provide an estimation of the wall-to-lumen ratio (WLR) of retinal arterioles. Moreover, a noninvasive measurement of basal and total capillary density may be obtained by videomicroscopy/capillaroscopy. No direct comparison of these three noninvasive techniques in the same population was previously performed; in particular, adaptive optics was never validated against micromyography. METHODS: In the current study, we enrolled 41 controls and patients: 12 normotensive lean controls, 12 essential hypertensive lean patients, nine normotensive obese patients and eight hypertensive obese patients undergoing elective surgery. All patients underwent a biopsy of subcutaneous fat during surgery. Subcutaneous small resistance artery structure was assessed by wire micromyography and the media-to-lumen ratio was calculated. WLR of retinal arterioles was obtained by SLDF and adaptive optics. Functional (basal) and structural (total) microvascular density was evaluated by capillaroscopy before and after venous congestion. RESULTS AND CONCLUSION: Our data suggest that adaptive optics has a substantial advantage over SLDF in terms of evaluation of microvascular morphology, as WLR measured with adaptive optics is more closely correlated with the M/L of subcutaneous small arteries (r = 0.84, P < 0.001 vs. r = 0.52, P < 0.05, slopes of the relations: P < 0.01 adaptive optics vs. SLDF). In addition, the reproducibility of the evaluation of the WLR with adaptive optics is far better, as compared with SLDF, as intraobserver and interobserver variation coefficients are clearly smaller. This may be important in terms of clinical evaluation of microvascular morphology in a clinical setting, as micromyography has substantial limitations in its clinical application due to the local invasiveness of the procedure.


Assuntos
Arteríolas/diagnóstico por imagem , Hipertensão Essencial/diagnóstico por imagem , Fluxometria por Laser-Doppler/métodos , Angioscopia Microscópica , Imagem Óptica/métodos , Vasos Retinianos/diagnóstico por imagem , Adulto , Idoso , Artérias/fisiopatologia , Arteríolas/patologia , Biópsia , Pressão Sanguínea , Hipertensão Essencial/complicações , Hipertensão Essencial/patologia , Feminino , Humanos , Masculino , Microscopia de Vídeo , Pessoa de Meia-Idade , Obesidade/complicações , Obesidade/diagnóstico por imagem , Obesidade/patologia , Reprodutibilidade dos Testes , Gordura Subcutânea/irrigação sanguínea , Gordura Subcutânea/patologia , Magreza/complicações , Magreza/diagnóstico por imagem , Magreza/patologia
3.
Eur J Ophthalmol ; 23(6): 899-904, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23813106

RESUMO

PURPOSE: To evaluate the clinical efficacy of user-friendly software for the measurement of intraretinal hyporeflective spaces expression of macular edema. METHODS: Fifteen consecutive patients with diabetic retinopathy with clinically significant macular edema were examined using conventional spectral domain optical coherence tomography (OCT). A new composite software application, OCT-measurement analysis tool (OCT-MAT), was developed to automatically process and analyze OCT B-scans by means of image acquisition, filtering, and elaboration, together with hyporeflective area recognition and measurement in µm2. The same macular areas were measured manually, and then compared to the measurements obtained by the automated OCT-MAT software. A statistical t test analysis was applied (statistical significance level at p<0.05). The repeatability and reproducibility coefficient for the automated software was computed using the Wilcoxon matched pair test (5% significance level). RESULTS: In all patients, the software effectively measured the number and extension of intraretinal hyporeflective spaces in µm2. The comparison between mean manual measurements and OCT-MAT measurements (0.478 ± 0.300 × 10(6) µm2 vs 0.471 ± 0.321 × 10(6) µm2) showed correct correspondence (p>0.05). Moreover, the OCT-MAT software showed good repeatability and reproducibility (coefficient below 3%). CONCLUSIONS: OCT-MAT allows the precise measurement of macular edema in terms of the number of empty spaces and their size in all patients. Its daily clinical application might give precise information regarding the evolution of macular edema and the efficacy of therapy.


Assuntos
Retinopatia Diabética/diagnóstico , Edema Macular/diagnóstico , Software , Tomografia de Coerência Óptica/instrumentação , Idoso , Diabetes Mellitus Tipo 1/complicações , Diabetes Mellitus Tipo 2/complicações , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Tomografia de Coerência Óptica/métodos , Acuidade Visual/fisiologia
4.
J Hypertens ; 30(6): 1169-75, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22504847

RESUMO

BACKGROUND: Structural alterations of subcutaneous small resistance arteries, as indicated by an increased media-to-lumen ratio, are frequently present in hypertensive and/or diabetic patients, and may represent the earliest alteration observed. Furthermore, media-to-lumen ratio of small arteries evaluated by micromyography has a strong prognostic significance; however, its extensive evaluation is limited by the invasivity of the assessment, since a biopsy of subcutaneous fat is needed. Noninvasive measurement of wall-to-lumen of retinal arterioles using scanning laser Doppler flowmetry (SLDF) has recently been introduced. However, this new technique has not yet been compared to micromyographic measurement, generally considered the gold standard approach. METHODS AND RESULTS: We investigated 40 individuals and patients, 24 of them were hypertensive patients and 16 normotensive individuals. All patients underwent a biopsy of subcutaneous fat during an elective surgical intervention. Subcutaneous small resistance arteries were dissected and mounted on a wire myograph, and media-to-lumen ratio was measured. In addition, an evaluation of wall-to-lumen ratio of retinal arterioles by SLDF was performed (Heidelberg Retina Flowmeter, Heidelberg Engineering). A close correlation was observed between media-to-lumen ratio of subcutaneous small arteries and wall-to-lumen ratio of retinal arterioles (r = 0.76, P < 0.001; P < 0.001, r(2) = 0.57). CONCLUSION: A noninvasive and easily repeatable procedure (intraobserver and interobserver variation coefficient <13%) such as an evaluation of the arterioles in the fundus oculi by SLDF may provide similar information regarding microvascular morphology compared with an invasive, accurate and prognostically relevant micromyographic measurement of media-to-lumen ratio of subcutaneous small arteries.


Assuntos
Artérias/diagnóstico por imagem , Arteríolas/diagnóstico por imagem , Fluxometria por Laser-Doppler/métodos , Vasos Retinianos/diagnóstico por imagem , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Ultrassonografia
5.
Am J Forensic Med Pathol ; 32(3): 280-6, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21811148

RESUMO

Analysis and detailed registration of the crime scene are of the utmost importance during investigations. However, this phase of activity is often affected by the risk of loss of evidence due to the limits of traditional scene of crime registration methods (ie, photos and videos). This technical note shows the utility of the application of a 3-dimensional optical digitizer on different crime scenes. This study aims in fact at verifying the importance and feasibility of contactless 3-dimensional reconstruction and modeling by optical digitization to achieve an optimal registration of the crime scene.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional , Lasers , Estudos de Viabilidade , Ciências Forenses/métodos , Humanos
6.
J Forensic Sci ; 54(3): 540-5, 2009 May.
Artigo em Inglês | MEDLINE | ID: mdl-19368623

RESUMO

In forensic pathology and anthropology, a correct analysis of lesions on soft tissues and bones is of the utmost importance, in order to verify the cause and manner of death. Photographs, videos, and photogrammetry may be an optimal manner of immortalizing a lesion, both on cadavers and skeletal remains; however, none of these can supply a detailed three-dimensional (3D) modeling of the lesion. Up to now, only the use of casts has given us the possibility of studying deep lesions such as saw marks with an accurate and complete 3D reconstruction of bone structure. The present study aims at verifying the applicability of 3D optical contactless measurement for the accurate recording of soft tissue and bone lesions, in order to develop a unique and precise method of registering and analyzing lesions, both in forensic pathology and anthropology. Three cases were analyzed: the first, a car accident with blunt force skin injuries; the second, a murder with blunt force injury to the head applied with a metal rod; the third, a series of sharp force knife and saw lesions on bone. Results confirm that 3D optical digitizing technology is a crucial tool in the immortalization of wound morphology in the medico-legal context even on "difficult" substrates such as cut marks and saw marks on bone.


Assuntos
Traumatismos Faciais/patologia , Fêmur/patologia , Antropologia Forense/métodos , Patologia Legal/métodos , Imageamento Tridimensional/métodos , Pele/patologia , Estudos de Viabilidade , Fêmur/lesões , Humanos , Lasers , Masculino , Pele/lesões , Ferimentos não Penetrantes/patologia , Ferimentos Perfurantes/patologia
7.
Sensors (Basel) ; 9(1): 568-601, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-22389618

RESUMO

3D imaging sensors for the acquisition of three dimensional (3D) shapes have created, in recent years, a considerable degree of interest for a number of applications. The miniaturization and integration of the optical and electronic components used to build them have played a crucial role in the achievement of compactness, robustness and flexibility of the sensors. Today, several 3D sensors are available on the market, even in combination with other sensors in a "sensor fusion" approach. An importance equal to that of physical miniaturization has the portability of the measurements, via suitable interfaces, into software environments designed for their elaboration, e.g., CAD-CAM systems, virtual renders, and rapid prototyping tools. In this paper, following an overview of the state-of-art of 3D imaging sensors, a number of significant examples of their use are presented, with particular reference to industry, heritage, medicine, and criminal investigation applications.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...