Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Artigo em Inglês | WPRIM (Pacífico Ocidental) | ID: wpr-890979

RESUMO

Background@#The Advisor™ HD Grid Mapping Catheter (Abbott Technologies, Minneapolis, MN) has been recently introduced. Although the clinical use of HD Grid mapping catheter is well described in adults with no congenital heart disease, there is limited data on the feasibility of using the HD Grid multipolar catheter to create voltage and activation mapping in adults with congenital heart disease. The purpose of this study was to evaluate the safety and technical feasibility of using the Advisor™ HD Grid mapping catheter during the catheter ablation of atrial arrhythmias in adults with congenital heart disease. We included 6 consecutive adults with congenital heart disease suffering from atrial arrhythmias in our study. The HD Grid mapping catheter was used to perform voltage and activation mapping. @*Results@#Six patients with congenital heart diseases (d-TGA n = 1, Tricuspid atresia n = 1, atrioventricular defect repair n= 1, secundum atrial septal defect n = 1, double-inlet single-ventricle n = 1, Tetralogy of Fallot = 1); majority (84%) male, with the mean age was 35 ± 10 years included in our series. The mean ablation duration and the fluoroscopy time were 789 ± 433 and 502 ± 355 s, respectively. The mean radiation dose was 7.52 ± 9 milliGy/cm2. The HD Grid mapping catheter was used successfully for entire arrhythmia mapping in 5 out of 6 cases. During one procedure, HD Grid mapping catheter could not be used for the entire mapping due to suboptimal reach through baffle puncture. The acute success rate of ablation was 100% with no immediate complications. @*Conclusions@#The use of HD Grid mapping catheter is a safe and valuable adjunct to accurately create voltage and activation mapping in ACHD patients undergoing radiofrequency catheter ablation. However, a contact force-sensing ablation catheter should be considered in conjunction to supplement data acquisition in challenging anatomy and substrates.

2.
Artigo em Inglês | WPRIM (Pacífico Ocidental) | ID: wpr-890968

RESUMO

Background@#This is a rare and challenging case of Wolff–Parkinson–White syndrome due to a posteroseptal acces‑ sory pathway located in the coronary sinus diverticulum. It is often difficult to precisely locate this type of accessory pathway, and the ablation procedure could be associated with collateral damage to the neighbouring coronary arteries.Case Presentation: The patient was a 49-year-old female with Wolff–Parkinson–White syndrome who was referred for catheter ablation. She had had a previous unsuccessful attempt at ablation and had remained symptomatic despite drug therapy. The pre-procedural cardiac computed tomography scan revealed the presence of a diverticu‑ lum in the proximal coronary sinus. Using an advanced three-dimensional cardiac mapping system, the electroana‑ tomic map of the diverticulum was created. The accessory pathway potential was identified within the diverticulum preceding the ventricular insertion. The accessory pathway was then successfully ablated using radiofrequency energy. @*Conclusion@#We have demonstrated that the advanced three-dimensional cardiac mapping system plays a very important role in guiding clinicians in order to precisely locate and safely ablate this type of challenging accessory pathway.

3.
Artigo em Inglês | WPRIM (Pacífico Ocidental) | ID: wpr-898683

RESUMO

Background@#The Advisor™ HD Grid Mapping Catheter (Abbott Technologies, Minneapolis, MN) has been recently introduced. Although the clinical use of HD Grid mapping catheter is well described in adults with no congenital heart disease, there is limited data on the feasibility of using the HD Grid multipolar catheter to create voltage and activation mapping in adults with congenital heart disease. The purpose of this study was to evaluate the safety and technical feasibility of using the Advisor™ HD Grid mapping catheter during the catheter ablation of atrial arrhythmias in adults with congenital heart disease. We included 6 consecutive adults with congenital heart disease suffering from atrial arrhythmias in our study. The HD Grid mapping catheter was used to perform voltage and activation mapping. @*Results@#Six patients with congenital heart diseases (d-TGA n = 1, Tricuspid atresia n = 1, atrioventricular defect repair n= 1, secundum atrial septal defect n = 1, double-inlet single-ventricle n = 1, Tetralogy of Fallot = 1); majority (84%) male, with the mean age was 35 ± 10 years included in our series. The mean ablation duration and the fluoroscopy time were 789 ± 433 and 502 ± 355 s, respectively. The mean radiation dose was 7.52 ± 9 milliGy/cm2. The HD Grid mapping catheter was used successfully for entire arrhythmia mapping in 5 out of 6 cases. During one procedure, HD Grid mapping catheter could not be used for the entire mapping due to suboptimal reach through baffle puncture. The acute success rate of ablation was 100% with no immediate complications. @*Conclusions@#The use of HD Grid mapping catheter is a safe and valuable adjunct to accurately create voltage and activation mapping in ACHD patients undergoing radiofrequency catheter ablation. However, a contact force-sensing ablation catheter should be considered in conjunction to supplement data acquisition in challenging anatomy and substrates.

4.
Artigo em Inglês | WPRIM (Pacífico Ocidental) | ID: wpr-898672

RESUMO

Background@#This is a rare and challenging case of Wolff–Parkinson–White syndrome due to a posteroseptal acces‑ sory pathway located in the coronary sinus diverticulum. It is often difficult to precisely locate this type of accessory pathway, and the ablation procedure could be associated with collateral damage to the neighbouring coronary arteries.Case Presentation: The patient was a 49-year-old female with Wolff–Parkinson–White syndrome who was referred for catheter ablation. She had had a previous unsuccessful attempt at ablation and had remained symptomatic despite drug therapy. The pre-procedural cardiac computed tomography scan revealed the presence of a diverticu‑ lum in the proximal coronary sinus. Using an advanced three-dimensional cardiac mapping system, the electroana‑ tomic map of the diverticulum was created. The accessory pathway potential was identified within the diverticulum preceding the ventricular insertion. The accessory pathway was then successfully ablated using radiofrequency energy. @*Conclusion@#We have demonstrated that the advanced three-dimensional cardiac mapping system plays a very important role in guiding clinicians in order to precisely locate and safely ablate this type of challenging accessory pathway.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...