Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
IEEE Trans Biomed Eng ; 70(9): 2624-2635, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37027277

RESUMO

OBJECTIVE: In this paper, we focus on the carrying out and validation of minimally invasive three-dimensional (3D) ultrasound (US) imaging of the auditory system, which is based on a new miniaturized endoscopic 2D US transducer. METHODS: This unique probe consists of a 18 MHz 24 elements curved array transducer with a distal diameter of 4 mm so it can be inserted into the external auditory canal. Typical acquisition is achieved by rotating such a transducer around its own axis using a robotic platform. Reconstruction of a US volume from the set of acquired B-scans during the rotation is then performed using scan-conversion. The accuracy of the reconstruction procedure is evaluated using a dedicated phantom that includes a set of wires as reference geometry. RESULTS: Twelve acquisitions obtained from different probe poses are compared to a micro-computed tomographic model of the phantom, leading to a maximum error of 0.20 mm. Additionally, acquisitions with a cadaveric head highlight the clinical applicability of this set up. Structures of the auditory system such as the ossicles and the round window can be identified from the obtained 3D volumes. CONCLUSION: These results confirm that our technique enables the accurate imaging of the middle and inner ears without having to deteriorate the surrounding bone. SIGNIFICANCE: Since US is a real-time, wide available and non-ionizing imaging modality, our acquisition setup could facilitate the minimally invasive diagnosis and surgical navigation for otology in a fast, cost-effective and safe way.


Assuntos
Robótica , Ultrassom , Humanos , Ultrassonografia , Tomografia Computadorizada por Raios X , Imagens de Fantasmas , Transdutores , Imageamento Tridimensional/métodos
2.
Malar J ; 17(1): 401, 2018 Oct 31.
Artigo em Inglês | MEDLINE | ID: mdl-30382855

RESUMO

BACKGROUND: The genetic diversity of malaria antigens often results in allele variant-specific immunity, imposing a great challenge to vaccine development. Rhoptry Neck Protein 2 (PvRON2) is a blood-stage antigen that plays a key role during the erythrocyte invasion of Plasmodium vivax. This study investigates the genetic diversity of PvRON2 and the naturally acquired immune response to P. vivax isolates. RESULTS: Here, the genetic diversity of PvRON21828-2080 and the naturally acquired humoral immune response against PvRON21828-2080 in infected and non-infected individuals from a vivax malaria endemic area in Brazil was reported. The diversity analysis of PvRON21828-2080 revealed that the protein is conserved in isolates in Brazil and worldwide. A total of 18 (19%) patients had IgG antibodies to PvRON21828-2080. Additionally, the analysis of the antibody response in individuals who were not acutely infected with malaria, but had been infected with malaria in the past indicated that 32 patients (33%) exhibited an IgG immune response against PvRON2. CONCLUSIONS: PvRON2 was conserved among the studied isolates. The presence of naturally acquired antibodies to this protein in the absence of the disease suggests that PvRON2 induces a long-term antibody response. These results indicate that PvRON2 is a potential malaria vaccine candidate.


Assuntos
Variação Genética , Imunidade Humoral , Malária Vivax/imunologia , Plasmodium vivax/genética , Proteínas de Protozoários/genética , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Proteínas de Protozoários/imunologia , Análise de Sequência de DNA
3.
J Chromatogr A ; 1423: 136-48, 2015 Dec 04.
Artigo em Inglês | MEDLINE | ID: mdl-26545337

RESUMO

In the last years several studies were carried out in order to separate gas mixtures by SMB technology; however, this technology has never been implemented on an industrial scale. In the present work, a gas phase SMB bench unit was built and tested for the separation of propane and propylene mixtures, using 13X zeolite extrudates as adsorbent and isobutane as desorbent. Three experiments were performed to separate propane/propylene by gas phase SMB in the bench scale unit with a 4-2-2 configuration, i.e., open loop circuit by suppressing section IV (desorbent regeneration followed by a recycle). Consequently, all the experiments were conducted using an external supply of pure isobutane as desorbent. Parameters such as switching time, extract and raffinate stream flow rates were changed to improve the efficiency of the process. Experimental results have shown that it is feasible to separate propylene from propane by gas phase SMB at a bench scale and that this process is a potential candidate to replace the conventional technologies for the propane/propylene separation. The performance parameters obtained are very promising for future development of this technology, since propylene was obtained in the extract stream with a purity of 99.93%, a recovery of 99.51%, and a productivity of [Formula: see text] . Propane was obtained in the raffinate stream with a purity of 98.10%, a recovery of 99.73% and a productivity of [Formula: see text] . The success of the above mentioned bench scale tests is a big step for the future implementation of this technology in a larger scale.


Assuntos
Alcenos/química , Técnicas de Química Analítica/métodos , Propano/química , Zeolitas/química , Adsorção
4.
Malar J ; 13: 280, 2014 Jul 22.
Artigo em Inglês | MEDLINE | ID: mdl-25047177

RESUMO

BACKGROUND: Although malaria in Brazil almost exclusively occurs within the boundaries of the Amazon Region, some concerns are raised regarding imported malaria to non-endemic areas of the country, notably increased incidence of complications due to delayed diagnoses. However, although imported malaria in Brazil represents a major health problem, only a few studies have addressed this subject. METHODS: A retrospective case series is presented in which 263 medical charts were analysed to investigate the clinical and epidemiological characterization of malaria cases that were diagnosed and treated at Hospital & Clinics, State University of Campinas between 1998 and 2011. RESULTS: Amongst all medical charts analysed, 224 patients had a parasitological confirmed diagnosis of malaria. Plasmodium vivax and Plasmodium falciparum were responsible for 67% and 30% of the infections, respectively. The majority of patients were male (83%) of a productive age (median, 37 years old). Importantly, severe complications did not differ significantly between P. vivax (14 cases, 9%) and P. falciparum (7 cases, 10%) infections. CONCLUSIONS: Severe malaria cases were frequent among imported cases in Brazil outside of the Amazon area. The findings reinforce the idea that P. vivax infections in Brazil are not benign, regardless the endemicity of the area studied. Moreover, as the hospital is located in a privileged site, it could be used for future studies of malaria relapses and primaquine resistance mechanisms. Finally, based on the volume of cases treated and the secondary complications, referral malaria services are needed in the non-endemic areas of Brazil for a rapid and efficient and treatment.


Assuntos
Malária Falciparum/epidemiologia , Malária Vivax/epidemiologia , Parasitemia/epidemiologia , Viagem , Síndrome da Imunodeficiência Adquirida/epidemiologia , Adolescente , Adulto , Anemia/etiologia , Antimaláricos/uso terapêutico , Artemeter , Artemisininas/uso terapêutico , Brasil/epidemiologia , Cloroquina/uso terapêutico , Comorbidade , Feminino , Seguimentos , Humanos , Malária Falciparum/sangue , Malária Falciparum/complicações , Malária Falciparum/tratamento farmacológico , Malária Vivax/sangue , Malária Vivax/complicações , Malária Vivax/tratamento farmacológico , Masculino , Mefloquina/uso terapêutico , Pessoa de Meia-Idade , Parasitemia/parasitologia , Primaquina/uso terapêutico , Recidiva , Estudos Retrospectivos , Centros de Atenção Terciária/estatística & dados numéricos , Trombocitopenia/etiologia , Adulto Jovem
5.
Langmuir ; 28(13): 5715-23, 2012 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-22404208

RESUMO

Powder, agglomerates, and tablets of the microporous zirconium(IV) terephthalate metal-organic framework UiO-66 were evaluated for the selective adsorption and separation of xylene isomers in the liquid phase using n-heptane as the eluent. Pulse experiments, performed at 313 K in the presence of n-heptane, revealed the o-xylene preference of this material, which was further confirmed by binary and multicomponent breakthrough experiments in the presence of m- and p-xylene, resulting in selectivities at 313 K of 1.8 and 2.4 with regards to m-xylene and p-xylene, respectively. Additionally, because p-xylene is the less retained isomer, UiO-66 presents a selectivity pattern that is reverse of that of the xylenes' molecular dimension with respect to shape selectivity. The shaping of the material as tablets did not significantly change its selectivity toward the o-xylene isomer or toward p-xylene, which was the less retained isomer, despite a loss in capacity. Finally, the selectivity behavior of UiO-66 in the liquid n-heptane phase makes it a suitable material for o-xylene separation in the extract (heavy product) or p-xylene separation in the raffinate (light product) by simulated moving bed technology.


Assuntos
Compostos Organometálicos/química , Ácidos Ftálicos/química , Xilenos/química , Zircônio/química , Adsorção , Isomerismo , Modelos Moleculares , Conformação Molecular , Temperatura
6.
Langmuir ; 28(7): 3494-502, 2012 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-22260425

RESUMO

The potential of the porous crystalline titanium dicarboxylate MIL-125(Ti) in powder form was studied for the separation in liquid phase of xylene isomers and ethylbenzene (MIL stands for Materials from Institut Lavoisier). We report here a detailed experimental study consisting of binary and multi-component adsorption equilibrium of xylene isomers in MIL-125(Ti) powder at low (≤0.8 M) and bulk (≥0.8 M) concentrations. A series of multi-component breakthrough experiments was first performed using n-heptane as the eluent at 313 K, and the obtained selectivities were compared, followed by binary breakthrough experiments to determine the adsorption isotherms at 313 K, using n-heptane as the eluent. MIL-125(Ti) is a para-selective material suitable at low concentrations to separate p-xylene from the other xylene isomers. Pulse experiments indicate a separation factor of 1.3 for p-xylene over o-xylene and m-xylene, while breakthrough experiments using a diluted ternary mixture lead to selectivity values of 1.5 and 1.6 for p-xylene over m-xylene and o-xylene, respectively. Introduction of ethylbenzene in the mixture results however in a decrease of the selectivity.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...