1.
Arq Bras Oftalmol ; 70(1): 129-32, 2007.
Artigo em Português | MEDLINE | ID: mdl-17505733

RESUMO

The authors present a case of butterfly-shaped pattern dystrophy diagnosed in a male patient, with retinal pigmented epithelium atrophy and central visual acuity decrease in one of the eyes. The evolution of this case was not benign as described in previous reports. A well-defined lesion located in the posterior pole of both eyes associated with fluorescein angiography allowed the diagnosis of this pattern dystrophy. Optical coherence tomography was performed, showing the aspects of the pathology, for the first time.


Assuntos
Distrofias Hereditárias da Córnea/diagnóstico , Idoso , Angiofluoresceinografia , Humanos , Masculino , Tomografia de Coerência Óptica , Acuidade Visual
2.
Arq. bras. oftalmol ; 70(1): 129-132, jan.-fev. 2007. ilus
Artigo em Português | LILACS | ID: lil-453142

RESUMO

Os autores apresentam um caso de distrofia macular em forma-de-borboleta, diagnosticado em paciente do sexo masculino, apresentando concomitante atrofia do epitélio pigmentado da retina e perda visual central em um dos olhos. Os achados relatados contrariam conceitos inicialmente disponíveis de curso sempre benigno da doença. A lesão característica e bem delimitada no pólo posterior e a angiofluoresceinografia, permitiram estabelecer o diagnóstico. Descreve-se ainda, pela primeira vez, os achados da distrofia em forma-de-borboleta à tomografia de coerência óptica.


The authors present a case of butterfly-shaped pattern dystrophy diagnosed in a male patient, with retinal pigmented epithelium atrophy and central visual acuity decrease in one of the eyes. The evolution of this case was not benign as described in previous reports. A well-defined lesion located in the posterior pole of both eyes associated with fluorescein angiography allowed the diagnosis of this pattern dystrophy. Optical coherence tomography was performed, showing the aspects of the pathology, for the first time.


Assuntos
Humanos , Masculino , Idoso , Displasia Retiniana/diagnóstico , Óculos , Angiofluoresceinografia , Displasia Retiniana/reabilitação , Tomografia de Coerência Óptica , Acuidade Visual
3.
Arq. bras. oftalmol ; 69(6): 871-874, nov.-dez. 2006. tab
Artigo em Português | LILACS | ID: lil-440426

RESUMO

OBJETIVO: Estudar a camada de fibras nervosas da retina de portadores de esquistossomose mansônica hepatoesplênica. MÉTODOS: Foram submetidos ao exame com o GDx Scanning Laser System, 23 portadores de esquistossomose na forma hepatoesplênica que tinham sido submetidos, quando crianças, a esplenectomia, ligadura da veia gástrica esquerda e auto-implante de tecido esplênico no omento maior. Todos apresentaram pressão intra-ocular menor que 21 mmHg. No grupo controle foram estudados 23 indivíduos com idade e condição socioeconômico-geográfica similar, sem esquistossomose. RESULTADOS: Em apenas um paciente do grupo portador de esquistossomose foram observadas alterações em quatro parâmetros: superior nasal, média superior, média da espessura e número de fibra. Todos os indivíduos do grupo controle apresentaram GDx com parâmetros dentro da normalidade. CONCLUSÃO: No estudo realizado não foi encontrado diferença significante entre os dois grupos. Apenas um paciente mostrou redução da camada de fibras nervosas.


PURPOSE: To study the retinal nerve fiber layer in young patients suffering from hepatosplenic schistosomiasis mansoni. METHODS: Twenty-three patients with hepatosplenic schistosomiasis mansoni who were submitted, when children, to splenectomy, ligature of the left gastric vein and auto-implantation of spleen tissue in the major omentum underwent GDx Scanning Laser System evaluations. All patients presented with intraocular pressure below 21 mmHg. RESULTS: Only one patient suffering from hepatosplenic schistosomiasis mansoni showed abnormalities on the GDx examination. There were no abnormalities on GDx examination in the control group. CONCLUSION: There was no significant difference between the two groups of this study. Only one patient showed retinal nerve fiber layer reduction.


Assuntos
Humanos , Masculino , Feminino , Adulto , Técnicas de Diagnóstico Oftalmológico , Hepatopatias Parasitárias/cirurgia , Fibras Nervosas/patologia , Vasos Retinianos/patologia , Esquistossomose mansoni/cirurgia , Esplenopatias/cirurgia , Estudos de Casos e Controles , Métodos Epidemiológicos , Pressão Intraocular , Lasers , Esplenectomia , Esplenopatias/parasitologia , Fatores de Tempo
4.
Arq Bras Oftalmol ; 69(6): 871-4, 2006.
Artigo em Português | MEDLINE | ID: mdl-17273682

RESUMO

PURPOSE: To study the retinal nerve fiber layer in young patients suffering from hepatosplenic schistosomiasis mansoni. METHODS: Twenty-three patients with hepatosplenic schistosomiasis mansoni who were submitted, when children, to splenectomy, ligature of the left gastric vein and auto-implantation of spleen tissue in the major omentum underwent GDx Scanning Laser System evaluations. All patients presented with intraocular pressure below 21 mmHg. RESULTS: Only one patient suffering from hepatosplenic schistosomiasis mansoni showed abnormalities on the GDx examination. There were no abnormalities on GDx examination in the control group. CONCLUSION: There was no significant difference between the two groups of this study. Only one patient showed retinal nerve fiber layer reduction.


Assuntos
Técnicas de Diagnóstico Oftalmológico , Hepatopatias Parasitárias , Fibras Nervosas/patologia , Vasos Retinianos/patologia , Esquistossomose mansoni/diagnóstico , Esplenopatias , Adulto , Métodos Epidemiológicos , Feminino , Humanos , Pressão Intraocular , Lasers , Hepatopatias Parasitárias/parasitologia , Hepatopatias Parasitárias/cirurgia , Masculino , Esquistossomose mansoni/cirurgia , Esplenectomia , Esplenopatias/parasitologia , Esplenopatias/cirurgia , Fatores de Tempo
5.
Arq Bras Oftalmol ; 68(2): 195-7, 2005.
Artigo em Português | MEDLINE | ID: mdl-15905940

RESUMO

PURPOSES: To evaluate the retina nerve fiber layer by laser polarimetry in patients in chronic use of chloroquine. METHODS: Forty-four eyes of twenty-two patients were studied. These were in use of chloroquine due to rheumatic diseases during at least one year. As a control group, twenty patients without use of chloroquine with similar characteristics (age, gender and race) were included. Patients who had a family history of ocular hypertension or glaucoma were not included in this group. Both eyes were submitted to analysis of the retina nerve fiber layer with a GDx Nerve Fiber Analyzer. RESULTS: In 28 eyes (63.6%) of chronic chloroquine users, alterations in more than two parameters by GDx were found. There was alteration in the Deviation from the normal graph with a loss of nerve fibers in 11 eyes (25%). When these results were compared with the control group, there was a significant statistical difference between the following parameters: Superior Ratio, Inferior Ratio, Superior Nasal, Elipse Modulation, The Number, Superior Average and Superior Integral. There was also a significant statistical association between the time of chloroquine use and loss of nerve fiber layer. CONCLUSIONS: From the results the following conclusion can be drawn: the chronic use of chloroquine was associated with alteration of the nerve fiber layer. Thus these results may contribute to early diagnosis of nerve fiber layer loss in chloroquine retinopathy.


Assuntos
Antirreumáticos/efeitos adversos , Cloroquina/efeitos adversos , Fibras Nervosas/efeitos dos fármacos , Células Ganglionares da Retina/efeitos dos fármacos , Adulto , Idoso , Estudos de Casos e Controles , Técnicas de Diagnóstico Oftalmológico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fibras Nervosas/patologia , Células Ganglionares da Retina/patologia , Doenças Reumáticas/tratamento farmacológico
6.
Arq. bras. oftalmol ; 68(2): 195-197, mar.-abr. 2005. tab
Artigo em Português | LILACS | ID: lil-402514

RESUMO

OBJETIVOS: Avaliar a camada de fibras nervosas da retina (CFN) por meio da polarimetria a laser, em pacientes em uso crônico de cloroquina. MÉTODOS: Foram estudados 44 olhos de 22 pacientes em uso de cloroquina por doenças reumatológicas, por pelo menos um ano. Como controle, foram incluídos vinte indivíduos sem uso de cloroquina com idade, gênero e raça similares. Foram excluídos os pacientes que apresentavam história familiar de hipertensão ocular ou glaucoma. Ambos os olhos foram submetidos à análise da camada de fibras nervosas da retina, com o aparelho GDx® Nerve Fiber Analyser, pelo mesmo examinador. RESULTADOS: Nos usuários crônicos de cloroquina, verificou-se alteração em mais de dois parâmetros do GDx em 28 olhos (63,6 por cento). Ocorreu também alteração no gráfico "Deviation from normal" com perda de fibras nervosas em 11 olhos (25 por cento). Quando comparado com o grupo controle, os parâmetros que demonstraram diferença estatisticamente significante foram: Superior Ratio, Inferior Ratio, Superior Nasal, Elipse Modulation, The Number, Superior Average e Superior Integral. Houve também associação estatisticamente significante entre o tempo de uso de cloroquina e perda da CFN. CONCLUSÕES: Comprovou-se a associação entre o uso crônico da cloroquina e a alteração da CFN detectada pelo GDx. Desta forma, esses resultados podem contribuir para o diagnóstico precoce da perda de fibras nervosas na retinopatia por cloroquina.


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Antirreumáticos , Cloroquina/efeitos adversos , Fibras Nervosas/efeitos dos fármacos , Células Ganglionares da Retina , Estudos de Casos e Controles , Técnicas de Diagnóstico Oftalmológico , Doenças Reumáticas/tratamento farmacológico , Fibras Nervosas/patologia , Células Ganglionares da Retina
7.
An. Fac. Med. Univ. Fed. Pernamb ; 49(2): 83-85, 2004. tab
Artigo em Português | LILACS | ID: lil-427850

RESUMO

O objetivo do presente estudo foi analisar os parâmetros da função pulmonar em usuários de colírio de timolol 0,5 por cento, portadores de equistossomose mansônica hepatoesplênica (EMH). Foi avaliada a capacidade respioratória, pela espirometria, em três grupos: Grupo I Sete portadores de EMH usuários de timolol a 0,5por cento; Grupo II - 10 portadores de EMH não usuários de timolol; e Grupo III - 9 pacientes glaucomatosos usuário de timolol a 0,5 por cento. Dos espirogramas realizados, no Grupo I - 5 pacientes (71,4por cento) apresentaram padrão obstrutivo pulmonar e 2 (28,6por cento) padrão restritivo; No Grupo II - 3 (30,0por cento) pacientes foram considerados normais, 5 (50,0por cento) apresentaram padrão obstrutivo pulmonar e 2 (20,0por cento) padrão restritivo; e no Grupo III - 8 (88,9por cento) foram considerados normais, enquanto um (11,1por cento) apresentou padrão obstrutivo. Houve uma associação significante entre portadores de EMH e a presença de alterações da função pulmonar, independentemente do uso de colírio de timolol a 0,5por cento. A assocoiação significante entre EMH e as alterações dos parâmetros da função pulmonar, independentemente do uso de colírio de timonolol a 05por cento, emprestam suporte à conduta sistemática de avaliação da capacidade respiratória destes pacientes, antes do início da medicação; assim como a realização de exame clínico minucioso, para avaliar a real possibilidade de uso da mesma


Assuntos
Adulto , Pessoa de Meia-Idade , Masculino , Feminino , Humanos , Testes de Função Respiratória , Esquistossomose mansoni , Timolol , Grupos Controle , Glaucoma , Maleatos , Pobreza , Esplenectomia
8.
Rev. bras. oftalmol ; 61(11): 813-818, nov. 2002. tab
Artigo em Português | LILACS | ID: lil-335168

RESUMO

Objetivo: Determinar a sensibilidade e a especificidade do GDx Scanning Laser System em pacientes suspeitos de glaucoma. Casuística e Métodos: Foram submetidos ao exame, com o GDx Scanning Laser System, 48 pacientes (87 olhos) suspeitos de glaucoma com pressão intra-ocular acima de 20 e abaixo de 25 mmHg com campo visual normal, 26 pacientes (32 olhos) com pressão intra-ocular normal bem como campo visual sem alteração para constituir o grupo controle. Analisou-se a sensibilidade e a especificidade deste exame de analisador de fibras nervosas. Resultados: Considerando como exame anormal a presença de, pelo menos, um índice alterado entre pacientes suspeitos de glaucoma e normais, observou-se uma sensibilidade de 65,5 por cento e especificidade de 81,25 por cento. Comentários: O GDx Scanning Laser System apresenta pouca capacidade na diferenciação entre pacientes suspeitos de glaucoma e pacientes normais.


Assuntos
Humanos , Masculino , Feminino , Hipertensão Ocular/patologia , Fibras Nervosas , Retina , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...