Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Artigo em Inglês | BBO - Odontologia, LILACS | ID: biblio-1135522

RESUMO

Abstract Objective: To compare the immediate microleakage of carious fissures sealed with a caries infiltrant covered by a flowable composite or solely with a flowable composite. Material and Methods: Extracted carious molars (n=20) were selected and paired among the experimental groups according to caries progression scores. Experimental groups (n=10) were divided according to the following sealing techniques: 1) caries infiltrant (Icon) + flowable composite (Z350 flow); 2) flowable composite (Z350 flow). Specimens were immersed in 3% methylene blue and evaluated in a stereomicroscope. Microleakage scores were attributed independently by two calibrated evaluators and the mode value was considered as the mean for the specimen. Binomial tests were used to test differences between two independent sample proportions at 5% significance level. Results: In the flowable composite group, a higher prevalence of dye penetration along the full depth of the fissure was observed, compared with caries infiltrant + flowable composite (p<0.05). For specimens showing dye penetration up to half of the fissure, in caries infiltrant + flowable composite group, all specimens showed dye penetration into the sealant, but not over the infiltrant. Conclusion: Using caries infiltrant as sealing material under a flowable composite cover is effective to improve the immediate sealing ability in carious fissures compared to sealing with flowable composite.


Assuntos
Humanos , Selantes de Fossas e Fissuras/química , Cárie Dentária/prevenção & controle , Infiltração Dentária/diagnóstico por imagem , Materiais Dentários/química , Dente Molar , Brasil , Azul de Metileno
2.
Clin Oral Investig ; 23(4): 1865-1870, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30218229

RESUMO

OBJECTIVES: To evaluate the potential of conventional glass ionomer cement (GIC), Biodentine™, MTA, and Portland cement to induce mineral density changes in carious dentin compared to zinc oxide eugenol control cement (ZOE). MATERIALS AND METHODS: Fifty blocks of bovine root dentin were prepared and a biofilm model using ATCC strains of S.mutans, S.sobrinus, and L.casei was used to promote artificial dentin lesions. After demineralization, the blocks were randomly divided into the five cement groups. Half of the surface of each specimen received the tested material and the other half was covered with wax (control). Samples were stored in phosphate buffered saline solution for 30 days and after that were scanned in a micro-CT with standardized parameters. Dentin mineral density changes were calculated using differences in plot profiles of the exposed and control carious dentin. Friedman's test, followed by Wilcoxon signed-rank test was used with 5% significance. RESULTS: Mean ΔZ values for the cements were 48.63 ± 19.09 for the control (ZOE), 63.31 ± 32.59 for Biodentine™, 114.63 ± 72.92 for GIC, 109.56 ± 66.28 for MTA, and 106.88 ± 66.02 for Portland cement. All cements showed a statistically significant increase in ΔZ values compared to the control, but Biodentine™ values were statistically significantly lower compared to GIC and the other calcium silicate cements. CONCLUSIONS: Tested materials present potential to induce mineral density changes in carious bovine dentin. MTA, Portland, and GIC showed higher bioactivity potential than Biodentine™. CLINICAL RELEVANCE: Based on minimally invasive concept, materials with remineralization potential can be used to preserve diseased but still repairable dental tissue.


Assuntos
Cárie Dentária/terapia , Cimentos Dentários , Dentina/química , Minerais/análise , Compostos de Alumínio , Animais , Compostos de Cálcio , Bovinos , Combinação de Medicamentos , Cimentos de Ionômeros de Vidro , Teste de Materiais , Óxidos , Distribuição Aleatória , Silicatos , Microtomografia por Raio-X
3.
Int J Paediatr Dent ; 29(1): 50-57, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30264472

RESUMO

BACKGROUND: Efficient endodontic instrumentation of primary teeth is a challenge for paediatric dentists. AIM: To evaluate biomechanical outcomes of endodontic instrumentation with a reciprocating system in a polymer-prototyped primary maxillary central incisor. DESIGN: The specimen was systematically instrumented and micro-CT scanned before and after each file. The amount of debris, percentage of non-instrumented areas, removed dentin volume, and lower dentin thickness at specific points along the root canal were analyzed. RESULTS: A 10% increase in removed dentin volume was observed when R40 was compared to R25 (14.5% vs 4.2%). When comparing R50 with R40, this increase was only 3.4% (17.9% vs 14.5%). In the root cervical third, there was substantial reduction in dentin thickness with R50 (48.8%), followed by R40 (39.5%) and R25 (18.6%). There was no difference between R25 and R40 in the removal of dentin at the apical third (15.8%), while R50 resulted in 39.8% reduction in dentin thickness. Percentage of non-instrumented areas were the same for all files. Accumulated debris with R40 and R50 was the same (0.19 mm³) while for R25 was 0.11 mm³. CONCLUSIONS: The Reciproc® system was effective for instrumentation of a prototyped primary maxillary central incisor. The most suitable file for apical preparation was R40.


Assuntos
Incisivo/cirurgia , Dente Decíduo/cirurgia , Instrumentos Odontológicos , Dentina , Humanos , Maxila , Resultado do Tratamento
4.
Braz. j. oral sci ; 18: e191627, jan.-dez. 2019. ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1095362

RESUMO

Aim: The purpose of this study was to compare root canal volumes (RCVs) obtained by means of cone beam computed tomography (CBCT) to those obtained by micro-computed tomography (micro-CT) after applying different segmentation algorithms. Methods: Eighteen extracted human teeth with sound root canals were individually scanned in CBCT and micro-CT using specific acquisition parameters. Two different images segmentation strategies were applied to both acquisition methods (a visual and an automatic threshold). From each segmented tooth, the root canal volume was obtained. A paired t-test was used to identify differences between mean values resulted from the experimental groups and the gold standard. In addition, Pearson correlation coefficients and the agreement among the experimental groups with the gold standard were also calculated. The significance level adopted was 5%. Results: No statistical differences between the segmentation methods (visual and automatic) were observed for micro-CT acquired images. However, significant differences for the two segmentation methods tested were seen when CBCT acquired images were compared with the micro-CT automatic segmentation methods used. In general, an overestimation of the values in the visual method were observed while an underestimation was observed with the automatic segmentation algorithm. Conclusion: Cone beam computed tomography images acquired with parameters used in the present study resulted in low agreement with root canal volumes obtained with a micro-CT tomography gold standard method of RCV calculation


Assuntos
Tratamento do Canal Radicular , Imageamento Tridimensional , Tomografia Computadorizada de Feixe Cônico , Microtomografia por Raio-X
5.
Braz Oral Res ; 32: e60, 2018 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-29995065

RESUMO

The aim of this study was to check the in vitro accuracy of ICDAS criteria on digital images compared to visual examination for the diagnosis of occlusal caries against a micro-CT gold standard. ICDAS was scored in 40 extracted permanent molars by means of visual inspection and stereomicroscopic images. Visual examinations were performed in duplicate and at a one-week interval by three different calibrated examiners. The analysis of digital images by ICDAS criteria was also performed in duplicate, 1 month after visual examinations. The detection methods were compared by means of sensitivity, specificity, area under the curve, predictive positive and negative values, and accuracy for two different thresholds (1- sound vs. carious teeth; 2- tooth requiring operative vs. non-operative treatment). Sensitivity and accuracy values for threshold 1 in the visual ICDAS and image-based ICDAS methods were high for sensitivity (0.93 and 0.97) and for accuracy (0.83 and 0.85), but low for specificity (0.55 for both methods). Specificity values for threshold 2 were 0.77 and 0.82, while sensitivity was 0.33 and 0.28 for each method. Spearman's rank correlation coefficient was 0.53 and 0.43 (p<0.05) for visual and image-based ICDAS compared to the gold standard scores. Both visual and image-based ICDAS scores were similar to each other in terms of diagnostic accuracy when compared to the micro-CT gold standard. Low specificity for the presence of caries and sensitivity for the detection of caries requiring operative treatment were found.


Assuntos
Cárie Dentária/diagnóstico por imagem , Microtomografia por Raio-X/métodos , Cárie Dentária/patologia , Esmalte Dentário/diagnóstico por imagem , Esmalte Dentário/patologia , Dentina/diagnóstico por imagem , Dentina/patologia , Humanos , Variações Dependentes do Observador , Valores de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Estatísticas não Paramétricas
6.
Braz. oral res. (Online) ; 32: e60, 2018. tab, graf
Artigo em Inglês | LILACS | ID: biblio-952138

RESUMO

Abstract The aim of this study was to check the in vitro accuracy of ICDAS criteria on digital images compared to visual examination for the diagnosis of occlusal caries against a micro-CT gold standard. ICDAS was scored in 40 extracted permanent molars by means of visual inspection and stereomicroscopic images. Visual examinations were performed in duplicate and at a one-week interval by three different calibrated examiners. The analysis of digital images by ICDAS criteria was also performed in duplicate, 1 month after visual examinations. The detection methods were compared by means of sensitivity, specificity, area under the curve, predictive positive and negative values, and accuracy for two different thresholds (1- sound vs. carious teeth; 2- tooth requiring operative vs. non-operative treatment). Sensitivity and accuracy values for threshold 1 in the visual ICDAS and image-based ICDAS methods were high for sensitivity (0.93 and 0.97) and for accuracy (0.83 and 0.85), but low for specificity (0.55 for both methods). Specificity values for threshold 2 were 0.77 and 0.82, while sensitivity was 0.33 and 0.28 for each method. Spearman's rank correlation coefficient was 0.53 and 0.43 (p<0.05) for visual and image-based ICDAS compared to the gold standard scores. Both visual and image-based ICDAS scores were similar to each other in terms of diagnostic accuracy when compared to the micro-CT gold standard. Low specificity for the presence of caries and sensitivity for the detection of caries requiring operative treatment were found.


Assuntos
Humanos , Cárie Dentária/diagnóstico por imagem , Microtomografia por Raio-X/métodos , Valores de Referência , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Estatísticas não Paramétricas , Cárie Dentária/patologia , Esmalte Dentário/patologia , Esmalte Dentário/diagnóstico por imagem , Dentina/patologia , Dentina/diagnóstico por imagem
7.
Arch Oral Biol ; 72: 33-38, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27529305

RESUMO

OBJECTIVE: To investigate the relationship between degree of dentin demineralization with both lesion activity and morphology of the occlusal carious cavity. DESIGN: Occlusal sites (n=138) were identified by visual examination (Nyvad's scores 0-6) in 67 extracted teeth which were scanned in a high energy micro-CT. After 3D reconstruction, each stack was resliced in the mesio-distal direction and tooth mineral density (MD) was measured along a path from enamel to the deepest part of dentin in the slice showing the most severe carious involvement. Each site was classified in "open" or "closed" (if cavitated) depending on the morphology of the surrounding enamel walls as measured using micro-CT and as active or inactive in enamel or dentin by a clinical scoring system. RESULTS: Lesions showing dentin cavitation presented higher demineralization degree compared to non-cavitated, or enamel cavitated lesions. Inactive lesions presented lower demineralization degree compared to active lesions, although with a low effect size. According to the morphological aspect of the carious cavity, open enamel lesions showed lower dentin demineralization degree than closed lesion environments. CONCLUSION: Active lesions showed higher dentin demineralization degree than inactive ones, while lesions showing closed cavitation resulted in higher dentin demineralization degree only for enamel lesions. Including those parameters in treatment decisions may help to improve prognosis and increase effectiveness of the caries diagnostic systems in the clinical setting.


Assuntos
Cárie Dentária/patologia , Cárie Dentária/diagnóstico por imagem , Esmalte Dentário/diagnóstico por imagem , Esmalte Dentário/patologia , Dentina/diagnóstico por imagem , Dentina/patologia , Humanos , Técnicas In Vitro , Dente Serotino , Desmineralização do Dente/diagnóstico por imagem , Desmineralização do Dente/patologia , Microtomografia por Raio-X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...