Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Crit Care Med ; 43(4): 832-9, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25517477

RESUMO

OBJECTIVE: To evaluate whether using long-axis or short-axis view during ultrasound-guided internal jugular and subclavian central venous catheterization results in fewer skin breaks, decreased time to cannulation, and fewer posterior wall penetrations. DESIGN: Prospective, randomized crossover study. SETTING: Urban emergency department with approximate annual census of 60,000. SUBJECTS: Emergency medicine resident physicians at the Denver Health Residency in Emergency Medicine, a postgraduate year 1-4 training program. INTERVENTIONS: Resident physicians blinded to the study hypothesis used ultrasound guidance to cannulate the internal jugular and subclavian of a human torso mannequin using the long-axis and short-axis views at each site. MEASUREMENTS AND MAIN RESULTS: An ultrasound fellow recorded skin breaks, redirections, and time to cannulation. An experienced ultrasound fellow or attending used a convex 8-4 MHz transducer during cannulation to monitor the needle path and determine posterior wall penetration. Generalized linear mixed models with a random subject effect were used to compare time to cannulation, number of skin breaks and redirections, and posterior wall penetration of the long axis and short axis at each cannulation site. Twenty-eight resident physicians participated: eight postgraduate year 1, eight postgraduate year 2, five postgraduate year 3, and seven postgraduate year 4. The median (interquartile range) number of total internal jugular central venous catheters placed was 27 (interquartile range, 9-42) and subclavian was six catheters (interquartile range, 2-20). The median number of previous ultrasound-guided internal jugular catheters was 25 (interquartile range, 9-40), and ultrasound-guided subclavian catheters were three (interquartile range, 0-5). The long-axis view was associated with a significant decrease in the number of redirections at the internal jugular and subclavian sites, relative risk 0.4 (95% CI, 0.2-0.9) and relative risk 0.5 (95% CI, 0.3-0.7), respectively. There was no significant difference in the number of skin breaks between the long axis and short axis at the subclavian and internal jugular sites. The long-axis view for subclavian was associated with decreased time to cannulation; there was no significant difference in time between the short-axis and long-axis views at the internal jugular site. The prevalence of posterior wall penetration was internal jugular short axis 25%, internal jugular long axis 21%, subclavian short axis 64%, and subclavian long axis 39%. The odds of posterior wall penetration were significantly less in the subclavian long axis (odds ratio, 0.3; 95% CI, 0.1-0.9). CONCLUSIONS: The long-axis view for the internal jugular was more efficient than the short-axis view with fewer redirections. The long-axis view for subclavian central venous catheterization was also more efficient with decreased time to cannulation and fewer redirections. The long-axis approach to subclavian central venous catheterization is also associated with fewer posterior wall penetrations. Using the long-axis view for subclavian central venous catheterization and avoiding posterior wall penetrations may result in fewer central venous catheter-related complications.


Assuntos
Cateterismo Venoso Central/métodos , Veias Jugulares/diagnóstico por imagem , Veia Subclávia/diagnóstico por imagem , Cateterismo/métodos , Estudos Cross-Over , Humanos , Manequins , Estudos Prospectivos , Ultrassonografia de Intervenção/métodos
2.
CJEM ; 13(3): 162-4, 2011 May.
Artigo em Inglês | MEDLINE | ID: mdl-21524372

RESUMO

Retrobulbar hemorrhage is a rare complication of blunt ocular trauma. Without prompt intervention, permanent reduction in visual acuity can develop in as little as 90 minutes. We report a novel bedside ultrasound finding of conical deformation of the posterior ocular globe: the "guitar pick" sign. In our elderly patient, the ocular globe shape normalized post-lateral canthotomy and inferior cantholysis. Identifying this sonographic finding may add to the clinical examination when deciding whether to perform decompression.


Assuntos
Hemorragia Retrobulbar/diagnóstico por imagem , Idoso de 80 Anos ou mais , Feminino , Humanos , Tomografia Computadorizada por Raios X , Ultrassonografia
3.
CJEM ; 13(6): 384-9, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22436476

RESUMO

OBJECTIVES: As ultrasonography is increasingly used in the emergency department (ED), ultrasound equipment has become a potential threat to infection control. Improperly cleaned ultrasound probes may serve as a vector for pathogens such as methicillin-resistant Staphylococcus aureus (MRSA). The primary objective of this study was to determine the prevalence of MRSA colonization on ultrasound probes used in a busy, urban ED. It was hypothesized that cultures of our ED ultrasound probes would yield a significant number of positive results for MRSA. METHODS: In this observational study, 11 ED ultrasound probes were randomly sampled on 10 different occasions. Samples were taken using a RODAC plate method and were cultured for MRSA and methicillin-sensitive Staphylococcus aureus (MSSA). On half of the randomly assigned sampling occasions, a visual inspection of each ultrasound probe for general cleanliness was conducted and recorded. Data were stratified by ultrasound location in the ED and analyzed using the Fisher exact test, with p < 0.05 deemed to be statistically significant. RESULTS: Of 110 samples, no isolates of MRSA were cultured. One probe yielded a positive culture for MSSA. Probes in the medicine, trauma, and pediatrics areas were found to be clean 65%, 33%, and 70% of the time, respectively. This variability in probe cleanliness by ED location was found to be statistically significant (p < 0.01). CONCLUSIONS: Contrary to our hypothesis, MRSA contamination of ultrasound probes was not found. This finding suggests that the spread of MRSA by ED ultrasound machines in a high-volume urban ED is unlikely. Further research at different centres with larger sample sizes is required before these results can be generalized.


Assuntos
Contaminação de Equipamentos , Controle de Infecções , Staphylococcus aureus Resistente à Meticilina , Infecções Estafilocócicas/transmissão , Ultrassonografia/instrumentação , Colorado , Serviço Hospitalar de Emergência , Humanos , Infecções Estafilocócicas/prevenção & controle
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...