Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Annu Int Conf IEEE Eng Med Biol Soc ; 2022: 1944-1947, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-36086100

RESUMO

Sleep state classification is essential for managing and comprehending sleep patterns, and it is usually the first step in identifying sleep disorders. Polysomnography (PSG), the gold standard, is intrusive and inconvenient for regular/long-term sleep monitoring. Many sleep-monitoring techniques have recently seen a resurgence as a result of the rise of neural networks and advanced computing. Ballistocardiography (BCG) is an example of such a technique, in which vitals are monitored in a contactless and unobtrusive manner by measuring the body's reaction to cardiac ejection forces. A Multi-Headed Deep Neural Network is proposed in this study to accurately classify sleep-wake state and predict sleep-wake time using BCG sensors. This method achieves a 95.5% sleep-wake classification score. Two studies were conducted in a controlled and uncontrolled environment to assess the accuracy of sleep-awake time prediction. Sleep-awake time prediction achieved an accuracy score of 94.16% in a controlled environment on 115 subjects and 94.90% in an uncontrolled environment on 350 subjects. The high accuracy and contactless nature make this proposed system a convenient method for long-term monitoring of sleep states, and it may also aid in identifying sleep stages and other sleep-related disorders. Clinical Relevance- Current sleep-wake state classification methods, such as actigraphy and polysomnography, necessitate patient contact and a high level of patient compliance. The proposed BCG method was found to be comparable to the gold standard PSG and most wearable actigraphy techniques, and also represents an effective method of contactless sleep monitoring. As a result, clinicians can use it to easily screen for sleep disorders such as dyssomnia and sleep apnea, even from the comfort of one's own home.


Assuntos
Balistocardiografia , Aprendizado Profundo , Transtornos do Sono-Vigília , Humanos , Polissonografia/métodos , Sono
2.
Annu Int Conf IEEE Eng Med Biol Soc ; 2022: 1939-1943, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-36086663

RESUMO

Long-term acquisition of respiratory and heart signals is useful in a variety of applications, including sleep analysis, monitoring of respiratory and heart disorders, and so on. Ballistocardiography (BCG), a non-invasive technique that measures micro-body vibrations caused by cardiac contractions as well as motion caused by breathing, snoring, and body movements, would be ideal for long-term vital parameter acquisition. Turtle Shell Technologies Pvt. Ltd.'s Dozee device, which is based on BCG, is a contactless continuous vital parameters monitoring system. It is designed to measure Heart Rate (HR) and Respiratory Rate (RR) continuously and without contact in a hospital setting or at home. A validation study for HR and RR was conducted using Dozee by comparing it to the vitals obtained from the FDA-approved Patient Monitor. This was done in a sleep laboratory setting over 110 nights in 51 subjects to evaluate HR and over 20 nights in 17 subjects to evaluate RR at the National Institute of Mental Health and Neurosciences (NIMHANS), Bangalore, India. Approximately 789 hours data for HR and approximately 112 hours data for RR was collected. Dozee was able to achieve a mean absolute error of 1.72 bpm for HR compared to the gold standard ECG. A mean absolute error of ∼1.24 breaths/min was obtained in determining RR compared to currently used methods. Dozee is ideal for long-term contactless monitoring of vital parameters due to its low mean absolute errors in measuring both HR and RR. Clinical Relevance- Continuous and long-term vitals monitoring is known to enable early screening of clinical deterioration, improve patient outcomes and reduce mortality. Current methods of continuous monitoring are overly complex, costly, and rely heavily on patient compliance. The proposed remote vitals monitoring solution based on BCG was found to be at par with gold standard methods of recording HR and RR. As a result, clinicians can use it to effectively monitor patients in both the hospital and at home.


Assuntos
Balistocardiografia , Vacina BCG , Balistocardiografia/métodos , Frequência Cardíaca/fisiologia , Humanos , Índia , Taxa Respiratória/fisiologia , Estados Unidos
3.
Ann Neurosci ; 29(1): 16-20, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35875429

RESUMO

Background: Functions of the autonomic nervous system have cardinal importance in day-to-day life. Heart rate variability (HRV) has been shown to estimate the functioning of the autonomic nervous system. Imbalance in the functioning of the autonomic nervous system is seen to be associated with chronic conditions such as chronic kidney disease, cardiovascular diseases, diabetes mellitus, and so on. Purpose: To evaluate the efficacy of a non-contact ballistocardiography (BCG) system to calculate HRV parameters by comparing them to the parameters derived from a standard commercial software that uses an electrocardiogram (ECG). Methods: Current study captured an ECG signal using a three-channel ECG Holter machine, whereas the BCG signal was captured using a BCG sensor sheet consisting of vibroacoustic sensors placed under the mattress of the participants of the study. Results: The study was conducted on 24 subjects for a total of 54 overnight recordings. The proposed method covered 97.92% epochs of the standard deviation of NN intervals (SDNN) and 99.27% epochs of root mean square of successive differences (RMSSD) within 20 ms and 30 ms tolerance, respectively, whereas 98.84% of two-min intervals for low-frequency (LF) to high-frequency (HF) ratio was covered within a tolerance of 1. Kendall's coefficient of concordance was also calculated, giving a P < .001 for all the three parameters and coefficients 0.66, 0.55, and 0.44 for SDNN, RMSSD, and LF/HF, respectively. Conclusion: The results show that HRV parameters captured using unobtrusive and non-invasive BCG sensors are comparable to HRV calculated using ECG.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...