Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Talanta ; 165: 522-525, 2017 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-28153293

RESUMO

We demonstrate an electrokinetically pumped sheath flow nanospray interface for capillary electrophoresis coupled to negative mode electrospray mass spectrometry. In this interface, application of an electric field generates electro-osmotic flow at the interior of a glass emitter that is pulled to a 10-20µm inner diameter orifice. Electro-osmotic flow pumps liquid around the distal tip of the separation capillary, ensheathing analyte into the electrospray electrolyte. In negative ion mode, negative potential applied to an untreated glass emitter drives sheath flow away from the emitter orifice, decreasing the stability and efficiency of the spray. In this manuscript, we treat a portion of the interior of the electrospray emitter with 3-aminopropyltrimethoxysilane, which grafts primary amines to the interior. The amines take on a positive charge, which reverses electro-osmosis and generates stable sheath flow to the emitter orifice under negative potential. Negative mode operation is demonstrated by analyzing a metabolite extract from stage 1 Xenopus laevis embryos. Production of the treated emitters was quite reproducible. We evaluated the performance of three emitters using a set of amino acids; the relative standard deviation in peak intensity was 7% for the most intense component.

2.
J Am Soc Mass Spectrom ; 28(2): 247-252, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27798763

RESUMO

Capillary electrophoresis coupled with electrospray ionization typically employs two power supplies, one at each end of the capillary. One power supply is located at the proximal (injection) end of the capillary. The power supply located at the distal (detector) end of the capillary drives the electrospray. Electrophoresis is driven by the difference in potential between these power supplies. Separations that employ large capillary inner diameter, high conductivity background electrolyte, and high separation potentials generate higher current than that produced by the electrospray. Excess current flows through the electrospray power supply. Most power supplies are not designed to sink current, and the excess current will cause the electrospray voltage to deviate from its set point. We report a simple circuit to handle this excess current, allowing separations under a wide range of electrophoretic conditions. Graphical Abstract ᅟ.

3.
Artigo em Inglês | MEDLINE | ID: mdl-25913424

RESUMO

While capillary zone electrophoresis (CZE) has been used to produce very rapid and efficient separations, coupling these high-speed separations with mass spectrometry (MS) has been challenging. Now, with much faster and sensitive mass spectrometers, it is possible to take full advantage of the CZE speed and reconstruct the fast migrating peaks. Here are three high-speed CZE-MS analyses via an electrokinetically pumped sheath-flow interface. The first separation demonstrates CZE-ESI-MS of an amino acid mixture with a 2-min separation, >50,000 theoretical plates, low micromolar concentration detection limits, and subfemtomole mass detection limits (LTQ XL mass spectrometer). The second separation with our recently improved third-generation CE-MS interface illustrates a 20 amino acid separation in ∼7min with an average over 200,000 plate counts, and results in almost-baseline resolution of structural isomers, leucine and isoleucine. The third separation is of a BSA digest with a reproducible CZE separation and mass spectrometry detection in 2min. CZE-MS/MS analysis of the BSA digest identified 31 peptides, produced 52% sequence coverage, and generated a peak capacity of ∼40 across the 1-min separation window (Q-Exactive mass spectrometer).


Assuntos
Aminoácidos/análise , Eletroforese Capilar/métodos , Soroalbumina Bovina/química , Espectrometria de Massas em Tandem/métodos , Aminoácidos/isolamento & purificação , Animais , Bovinos , Eletroforese Capilar/economia , Espectrometria de Massas por Ionização por Electrospray/economia , Espectrometria de Massas por Ionização por Electrospray/métodos , Espectrometria de Massas em Tandem/economia , Fatores de Tempo
4.
Analyst ; 140(5): 1516-22, 2015 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-25599104

RESUMO

There is a need for low cost, sensitive and chemical specific detectors for routine characterization of biomolecules. In this study, we utilize sheath-flow surface-enhanced Raman scattering (SERS) to analyze a mixture of eight biologically-active peptides separated by capillary zone electrophoresis (CZE). Analysis of the SERS electropherogram resulting from online detection resolves the characteristic Raman bands attributed to the amino acid constituents of each peptide, which enables identification. The detection limit by SERS was found to be 10(-8) M. Our results suggest that the structural information obtained from the detected vibrational modes provides complementary characterization to other chemically specific detectors like mass spectrometry and improved chemical identification over other commonly used optical-based post-chromatographic detection methods. In addition, the sheath-flow SERS detection results in band narrowing in the observed electropherogram that enables distinction of closely migrating species. The results presented here indicate that this platform can provide fast, robust, reproducible, and chemical specific detection to facilitate the characterization of peptides.


Assuntos
Eletroforese Capilar/métodos , Sistemas On-Line , Fragmentos de Peptídeos/análise , Fragmentos de Peptídeos/química , Espectrometria de Massas por Ionização por Electrospray/métodos , Análise Espectral Raman/métodos , Humanos
5.
J Am Soc Mass Spectrom ; 25(4): 524-9, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24464359

RESUMO

A series of studies comparing the performance of alternating current electrospray ionization (AC ESI) mass spectrometry (MS) and direct current electrospray ionization (DC ESI) MS have been conducted, exploring the absolute signal intensity and signal-to-background ratios produced by both methods using caffeine and a model peptide as targets. Because the high-voltage AC signal was more susceptible to generating gas discharges, the operating voltage range of AC ESI was significantly smaller than that for DC ESI, such that the absolute signal intensities produced by DC ESI at peak voltages were one to two orders of magnitude greater than those for AC ESI. Using an electronegative nebulizing gas, sulfur hexafluoride (SF6), instead of nitrogen (N2) increased the operating range of AC ESI by ~50%, but did not appreciably improve signal intensities. While DC ESI generated far greater signal intensities, both ionization methods produced comparable signal-to-background noise, with AC ESI spectra appearing qualitatively cleaner. A quantitative calibration analysis was performed for two analytes, caffeine and the peptide MRFA. AC ESI utilizing SF6 outperforms all other techniques for the detection of MRFA, producing chromatographic limits of detection nearly one order of magnitude lower than that of DC ESI utilizing N2, and one-half that of DC ESI utilizing SF6. However, DC ESI outperforms AC ESI for the analysis of caffeine, indicating that improvements in spectral quality may benefit certain compounds or classes of compounds, on an individual basis.


Assuntos
Espectrometria de Massas por Ionização por Electrospray/métodos , Cafeína/análise , Cafeína/química , Limite de Detecção , Modelos Químicos , Peptídeos/análise , Peptídeos/química , Proteômica
6.
J Chromatogr A ; 1229: 268-73, 2012 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-22321948

RESUMO

Several glycosphingolipids were labeled with the fluorphore Bodipy-Fl and analyzed using capillary electrophoresis with laser-induced fluorescence detection. GM1-, LacCer-, and Cer-Bodipy-Fl were prepared through acylation using the N-hydroxysuccinimide ester of Bodipy-Fl. Several other glycosphingolipids including GT1a-, GD1a-, GM2-, GM3-, GD3-, and GlcCer-Bodipy-Fl were enzymatically synthesized. Micellar electrokinetic capillary chromatography with a TRIS/CHES/SDS/α-cyclodextrin buffer produced better separation than an established borate/deoxycholate/methyl-ß-cyclodextrin buffer. The nine Bodipy-Fl-labeled glycosphingolipid standards were separated in under 5 min, theoretical plate counts were between 640,000 and 740,000, and the limit of detection was approximately 3 pM or 240 ymol analyte injected onto the capillary.


Assuntos
Compostos de Boro/química , Cromatografia Capilar Eletrocinética Micelar/métodos , Eletroforese Capilar/métodos , Corantes Fluorescentes/química , Glicoesfingolipídeos/química , Boratos , Ácido Desoxicólico , Glicoesfingolipídeos/isolamento & purificação , Limite de Detecção , Dodecilsulfato de Sódio , Taurina/análogos & derivados , Trometamina , alfa-Ciclodextrinas , beta-Ciclodextrinas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...