Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sci Rep ; 11(1): 5948, 2021 03 15.
Artigo em Inglês | MEDLINE | ID: mdl-33723277

RESUMO

The internal exposure of workers who inhale plutonium dioxide particles in nuclear facilities is a crucial matter for human protection from radiation. To determine the activity median aerodynamic diameter values at the working sites of nuclear facilities in real time, we developed a high-resolution alpha imager using a ZnS(Ag) scintillator sheet, an optical microscope, and an electron-multiplying charge-coupled device camera. Then, we designed and applied a setup to measure a plutonium dioxide particle and identify the locations of the individual alpha particles in real time. Employing a Gaussian fitting, we evaluated the average spatial resolution of the multiple alpha particles was evaluated to be 16.2 ± 2.2 µmFWHM with a zoom range of 5 ×. Also, the spatial resolution for the plutonium dioxide particle was 302.7 ± 4.6 µmFWHM due to the distance between the plutonium dioxide particle and the ZnS(Ag) scintillator. The influence of beta particles was negligible, and alpha particles were discernible in the alpha-beta particle contamination. The equivalent volume diameter of the plutonium dioxide particle was calculated from the measured count rate. These results indicate that the developed alpha imager is effective in the plutonium dioxide particle measurements at the working sites of nuclear facilities for internal exposure dose evaluation.

2.
Phys Med Biol ; 64(13): 135019, 2019 07 05.
Artigo em Inglês | MEDLINE | ID: mdl-31071695

RESUMO

Low-energy x-ray imaging of the secondary electron bremsstrahlung (SEB) x-ray emitted during carbon-ion irradiation is a promising method for range estimation. However, it remains unclear whether the method can be used for imaging with the clinical dose levels of carbon-ion and whether the bremsstrahlung x-ray can be detected from the deeper part of the body. To clarify these points, we developed a new high resolution low-energy x-ray camera and conducted imaging of the SEB x-ray during the irradiation of carbon-ions of different energies and intensities. Imaging was also tried with an x-ray camera using a human-head-sized, 17 cm diameter cylindrical phantom. To develop a high resolution imaging detector for a low-energy x-ray, we used a 20 × 20 × 0.5 mm thick cerium-doped yttrium aluminum perovskite, YA1O3 (YAP(Ce)) scintillator plate, which was optically coupled to a 25 mm square high quantum efficiency (HQE) type position sensitive photomultiplier tube (PSPMT). The imaging detector was encased in a 2 cm thick tungsten container and a pinhole collimator was attached to its camera head. After evaluating the camera's performance, SEB x-ray imaging was tried during irradiation of the carbon-ion and compared the results with a Monte Carlo simulation. We imaged the beam tracks by the SEB x-ray in real-time during irradiation of the carbon-ion and imaging and range estimation were possible even with near clinical dose level of 7.5 × 108 particles of carbon-ion. Clear images of a SEB x-ray were also obtained for a 17 cm diameter cylindrical phantom. The measured images were good agreement with the Monte Carlo simulation. We confirmed that our developed YAP(Ce) camera is promising for imaging SEB x-rays during irradiation of carbon-ions even near clinical conditions.


Assuntos
Elétrons , Radioterapia com Íons Pesados , Radiografia/instrumentação , Ítrio/química , Humanos , Método de Monte Carlo , Imagens de Fantasmas
3.
Phys Med Biol ; 63(12): 125019, 2018 06 20.
Artigo em Inglês | MEDLINE | ID: mdl-29923503

RESUMO

Although luminescence of water lower in energy than the Cerenkov-light threshold during proton and carbon-ion irradiation has been found, the phenomenon has not yet been implemented for Monte Carlo simulations. The results provided by the simulations lead to misunderstandings of the physical phenomenon in optical imaging of water during proton and carbon-ion irradiation. To solve the problems, as well as to clarify the light production of the luminescence of water, we modified a Monte Carlo simulation code to include the light production from the luminescence of water and compared them with the experimental results of luminescence imaging of water. We used GEANT4 for the simulation of emitted light from water during proton and carbon-ion irradiation. We used the light production from the luminescence of water using the scintillation process in GEANT4 while those of Cerenkov light from the secondary electrons and prompt gamma photons in water were also included in the simulation. The modified simulation results showed similar depth profiles to those of the measured data for both proton and carbon-ion. When the light production of 0.1 photons/MeV was used for the luminescence of water in the simulation, the simulated depth profiles showed the best match to those of the measured results for both the proton and carbon-ion compared with those used for smaller and larger numbers of photons/MeV. We could successively obtain the simulated depth profiles that were basically the same as the experimental data by using GEANT4 when we assumed the light production by the luminescence of water. Our results confirmed that the inclusion of the luminescence of water in Monte Carlo simulation is indispensable to calculate the precise light distribution in water during irradiation of proton and carbon-ion.


Assuntos
Carbono/uso terapêutico , Luminescência , Fótons , Terapia com Prótons/métodos , Método de Monte Carlo , Água/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...