Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 65
Filtrar
1.
Radiography (Lond) ; 27(2): 419-424, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33092995

RESUMO

INTRODUCTION: Imaging is essential for the initial diagnosis and monitoring of the novel coronavirus, which emerged in Wuhan, China. This study aims to assess the insight of radiographers on how the COVID-19 pandemic has affected their work routine and if protective measures are applied. METHOD: A prospective observational study was conducted among radiographers registered in the Cyprus Society of Registered Radiologic Technologists & Radiation Therapy Technologists. A questionnaire composed of 28 multiple choice questions was utilised, and the data analysis was performed using SPSS software with the statistical significance assumed as p-value < 0.05. RESULTS: Out of 350 registered radiographers, 101 responses were received. The results showed that there are statistically significant differences regarding the working hours, the feeling of stress, the work effectiveness, the average examination time, the presence of a protocol used among the different workplaces of the participants; a private radiology centre, a private hospital or a public hospital, with a p-value 0.0022, 0.015, 0.027, 0.001, 0.0001 respectively. Also, statistically significant differences were observed in the decontamination methods used for equipment (p-value 0.007), for air (p-value 0.04) and when decontamination takes place (p-value 0.00032) among the different workplaces of the participants. Nonetheless, the majority of radiographers believe that their workplace is sufficiently provided with PPE, cleaning supplies, equipment, and with cleaning personnel and are optimistic regarding the adequacy of these provisions in the next three months. CONCLUSION: This study showed that in the Republic of Cyprus, there are protocols regarding protective measures against COVID-19, and the radiographers are adequately trained on how to face an infectious disease outbreak. However, work is needed in order to develop protocols that reassure the safety of patients and medical personnel while managing the excess workload effectively. IMPLICATIONS FOR PRACTICE: This study indicates the importance of applying protective measures and protocols in the radiology departments in order to minimise the spread of the virus.


Assuntos
COVID-19/epidemiologia , Protocolos Clínicos , Controle de Infecções/métodos , Pandemias , Radiografia/psicologia , Radiografia/normas , Adulto , Atitude do Pessoal de Saúde , COVID-19/diagnóstico , COVID-19/diagnóstico por imagem , COVID-19/transmissão , Teste Sorológico para COVID-19 , Chipre/epidemiologia , Descontaminação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estresse Ocupacional , Equipamento de Proteção Individual , Prática Privada , Estudos Prospectivos , Radiografia/instrumentação , Serviço Hospitalar de Radiologia , SARS-CoV-2 , Inquéritos e Questionários , Carga de Trabalho , Adulto Jovem
2.
Int J Gen Med ; 12: 247-254, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31410047

RESUMO

BACKGROUND AND AIM: The effects of Ramadan fasting on health are a little controversial. The present study is aimed at evaluating the metabolic effects on a group of 517 patients with ≥2 cardiovascular risk factors over a period running from 2012 to 2014. METHODS: Each patient was assessed at three visits: before, during, and after Ramadan. Demographical, clinical and biological tests were performed at each visit. RESULTS: Metabolically, we noted a significant and discrete rise in blood glucose level (+1.2 mmol/L), triglycerides (+0.3 mmol/L), cholesterol (+0.12 mmol/L) and creatinine (+3 µmol/L) during Ramadan. These disturbances decreased significantly after Ramadan. The same variations were observed among diabetics (n=323). However, there was a significant decrease in HbA1c after Ramadan (9.0% vs 7.6%, p<0.001). Our findings also revealed there was no significant correlation between variations of metabolic parameters and dietary intake. No acute metabolic incidents were reported during the study period. CONCLUSION: The current study showed that Ramadan is responsible for a transient but well tolerated disturbance of metabolic parameters followed by a significant post-Ramadan improvement. These changes did not seem to be directly related to dietary intake.

3.
Gynecol Endocrinol ; 35(5): 427-433, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30600738

RESUMO

Long-acting reversible contraceptives (LARC) represent an especially effective kind of post-abortion contraception. We aimed at assessing satisfaction, discontinuation, efficacy, and tolerability associated with either levonorgestrel intrauterine device (L-IUCD), the copper intrauterine device (C-IUCD) and implant (IMP) after termination of pregnancy (TOP). We recorded baseline data about the patients and performed phone surveys at 3, 6 and 12 months after insertion to assess the bleeding profile. Furthermore, women were inquired about possible adverse events, satisfaction, and discontinuation at 12 months after insertion. LARC continuers (>12 months after TOP) were divided into three groups: L-IUCD (n = 47), C-IUCD (n = 6) and IMP (n = 36). Satisfaction rates among L-IUCD users were higher than among IMP users (100% vs. 72.2%, p < .05). A higher, yet not significant, share of patients decided to withdraw contraception in IMP group (3.6% in IUCD group and 12.2% in IMP group). The bleeding profile was significantly more favorable among L-IUCD users than among IMP users. Finally, the reported rate of treatment-associated adverse events did not differ significantly among the groups. L-IUCD insertion after TOP is associated with higher satisfaction and lower discontinuation rates than IMP. Such pattern could be attributed to a more favorable bleeding profile.


Assuntos
Anticoncepção/métodos , Implantes de Medicamento/uso terapêutico , Dispositivos Intrauterinos , Aborto Induzido , Adulto , Implantes de Medicamento/administração & dosagem , Feminino , Humanos , Itália , Levanogestrel/uso terapêutico , Contracepção Reversível de Longo Prazo , Satisfação do Paciente , Estudos Prospectivos , Adulto Jovem
4.
Eur J Clin Microbiol Infect Dis ; 36(12): 2495-2501, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28866784

RESUMO

Intravenous drug users are at increased risk of Staphylococcus aureus infections. Most cases are related to clones prevalent in the community. We report an outbreak of community-acquired methicillin-resistant Staphylococcus aureus infections that occurred from 2007 to 2009 in intravenous drug users and their close contacts in Northwestern France. Clinical and molecular investigations suggested that the clones were more similar than those usually isolated in the American continent although none of the patients traveled abroad or had contact with individuals who had traveled to the Americas. Then, a retrospective whole genome sequencing and phylogenetic analyses demonstrated that the strains isolated from the first case belong to the USA300 Latin-American variant clone, based on the absence of arginine catabolic mobile element (ACME), and the presence of copper and mercury resistance mobile element (COMER), a distinctive feature of the South American variant. Our study shows genetic evidence for introduction of this clone as early as 2007 in France. This report also illustrates the importance of genome sequencing to finely characterize and monitor the emergence of unexpected S. aureus clones among high-risk populations, especially when living in promiscuity.


Assuntos
Infecções Comunitárias Adquiridas/epidemiologia , Infecções Comunitárias Adquiridas/microbiologia , Surtos de Doenças , Usuários de Drogas , Staphylococcus aureus Resistente à Meticilina , Infecções Estafilocócicas/epidemiologia , Infecções Estafilocócicas/microbiologia , Antibacterianos/farmacologia , França/epidemiologia , Humanos , Staphylococcus aureus Resistente à Meticilina/classificação , Staphylococcus aureus Resistente à Meticilina/efeitos dos fármacos , Testes de Sensibilidade Microbiana
5.
Int J Obstet Anesth ; 32: 17-20, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28599806

RESUMO

BACKGROUND: Transversus abdominis plane block is an effective method of post-cesarean analgesia. There are no data available about plasma bupivacaine levels after this block in adults. This study aimed to assess bupivacaine pharmacokinetic parameters after ultrasound-guided transversus abdominis plane blocks following cesarean delivery under spinal anesthesia. METHODS: A prospective observational study in parturients undergoing elective cesarean delivery under hyperbaric bupivacaine spinal anesthesia was conducted. After surgery, patients received bilateral transversus abdominis plane block (50mg bupivacaine each side). Venous blood samples were collected immediately before performing the block and at 10, 20, 30, 45, 60, 90, 120, 180, 240, 720 and 1440minutes. High performance liquid chromatography was used to measure total plasma bupivacaine concentrations. Mean bupivacaine area under the curve (AUC) was calculated from 0 to 24hours. RESULTS: Data were collected from 17 parturients. Mean age and body mass index were 31±6y and 30±4kg/m2 respectively. Mean plasma bupivacaine concentration before the block was 171ng/mL. Mean peak concentration was 802.36ng/mL (range 231.8 to 3504.5ng/mL). Mean time to peak concentration was 30min and mean area-under-the-curve (0-24h) was 4505.4h.ng/mL. Mean elimination half-life was 8.75h. Three subjects had concentrations above the quoted toxic threshold and mild symptoms suggestive of neurotoxicity were reported by two subjects, but no treatment was required. CONCLUSION: Single-dose bilateral transversus abdominis plane block using 100mg of bupivacaine, after spinal anesthesia for cesarean delivery, can result in toxic plasma bupivacaine concentrations.


Assuntos
Analgesia Obstétrica , Raquianestesia , Bupivacaína/farmacocinética , Bloqueio Nervoso/métodos , Ultrassonografia de Intervenção , Músculos Abdominais , Adulto , Cesárea , Feminino , Humanos , Gravidez , Estudos Prospectivos
6.
Thromb J ; 15: 15, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28588426

RESUMO

BACKGROUND: The effects of Ramadan fasting (RF) on clopidogrel antiplatelet inhibition were not previously investigated. The present study evaluated the influence of RF on platelet reactivity in patients with high cardiovascular risk (CVR) in particular those with type 2 diabetes mellitus (DM). METHODS: A total of 98 stable patients with ≥2 CVR factors were recruited. All patients observed RF and were taking clopidogrel at a maintenance dose of 75 mg. Clinical findings and serum lipids data were recorded before Ramadan (Pre-R), at the last week of Ramadan (R) and 4 weeks after the end of Ramadan (Post-R). During each patient visit, nutrients intakes were calculated and platelet reactivity assessment using Verify Now P2Y12 assay was performed. RESULTS: In DM patients, the absolute PRU changes from baseline were +27 (p = 0.01) and +16 (p = 0.02) respectively at R and Post-R. In addition, there was a significant increase of glycemia and triglycerides levels with a significant decrease of high-density lipoprotein. In non DM patients there was no significant change in absolute PRU values and metabolic parameters. Clopidogrel resistance rate using 2 cut-off PRU values (235 and 208) did not change significantly in DM and non DM patients. CONCLUSIONS: RF significantly decreased platelet sensitivity to clopidogrel in DM patients during and after Ramadan. This effect is possibly related to an increase of glycemia and serum lipids levels induced by fasting. TRIAL REGISTRATION: Clinical Trials.gov NCT02720133. Registered 24 July 2014.Retrospectively registered.

7.
Sci Rep ; 7: 40443, 2017 01 11.
Artigo em Inglês | MEDLINE | ID: mdl-28074866

RESUMO

In French Polynesia, respiratory tract clinical isolate M26, displayed unusual phenotype and contradictory phylogenetic affiliations, suggesting a hitherto unidentified rapidly-growing Mycobacterium species. The phenotype of strain M26 was further characterized and its genome sequenced. Strain M26 genome consists in a 5,732,017-bp circular chromosome with a G + C% of 67.54%, comprising 5,500 protein-coding genes and 52 RNA genes (including two copies of the 16 S rRNA gene). One region coding for a putative prophage was also predicted. An intriguing characteristic of strain M26's genome is the large number of genes encoding polyketide synthases and nonribosomal peptide synthases. Phylogenomic analysis showed that strain M26's genome is closest to the Mycobacterium phlei genome with a 76.6% average nucleotide identity. Comparative genomics of 33 Mycobacterium genomes yielded 361 genes unique to M26 strain which functional annotation revealed 84.21% of unknown function and 3.88% encoding lipid transport and metabolism; while 48.87% of genes absent in M26 strain have unknown function, 9.5% are implicated in transcription and 19% are implicated in transport and metabolism. Strain M26's unique phenotypic and genomic characteristics indicate it is representative of a new species named "Mycobacterium massilipolynesiensis". Looking for mycobacteria in remote areas allows for the discovery of new Mycobacterium species.


Assuntos
Mycobacterium phlei/fisiologia , Mycobacterium/crescimento & desenvolvimento , Filogenia , Mapeamento Cromossômico , DNA Circular/genética , Genes Bacterianos , Anotação de Sequência Molecular , Mycobacterium/ultraestrutura , Prófagos/genética
8.
Pathol Biol (Paris) ; 63(6): 248-51, 2015 Dec.
Artigo em Francês | MEDLINE | ID: mdl-26524955

RESUMO

UNLABELLED: Thrombocytopenia is a current situation for making a blood smear in routine practice in a medical analysis laboratory. Recent automated hematology analyzers enumerate platelets and generate histograms and specific flags. Operators must be aware of the characteristics of their analyzer in order to avoid spurious results in the case where microscopy review is not possible. OBJECTIVE: We evaluated the diagnostic performance of various graphical anomalies in the detection of large platelets and platelet clumps. PATIENTS AND METHODS: Three hundred cases of thrombocytopenia were included in the study on the basis of a platelet count less than 150 × 10(9)/L. This evaluation is expressed by the results of the sensitivity, specificity, positive predictive value and negative predictive value compared to the microscopic review of blood smear. RESULTS: Graphical performances are variable according to microscopic review of blood smears. Indeed, a not fitted curve is the most sensitive change on platelet histogram to the presence of large platelet. A high specificity to the presence of platelet clumps is announced when the platelet curve fails to return to the baseline. Moreover, characteristic findings on the DIFF scattergram are very specific to the presence of platelet clumps. CONCLUSION: A normal platelet histogram can validate with great confidence thrombocytopenia in cases where a blood smear cannot be read immediately.


Assuntos
Plaquetas/citologia , Tamanho Celular , Reconhecimento Automatizado de Padrão , Agregação Plaquetária , Trombocitopenia/diagnóstico , Plaquetas/patologia , Citodiagnóstico/métodos , Citodiagnóstico/normas , Humanos , Reconhecimento Automatizado de Padrão/normas , Contagem de Plaquetas/instrumentação , Contagem de Plaquetas/métodos , Valor Preditivo dos Testes , Sensibilidade e Especificidade , Trombocitopenia/sangue
9.
J Biomech ; 48(6): 1099-104, 2015 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-25661874

RESUMO

The validation of the AFM method for elastic modulus E measurement in soft materials (E <5 MPa) is still missing. The interest of measurements in materials with E <5 MPa is mainly biological, including soft tissues and single cells. For the diagnosis of malignant human tumors, a change in cell elasticity, within tissues, has recently been recognized as a marker of metastatic potential. To measure a cell elasticity difference, reproducible E measurements in biological samples are needed. In this work a robust method for a metrological validation of E measurements in the range 500-5000 kPa was developed, based on the realization of thick E standard samples and on the study of the interactions between the measurement process and the sample at micro- and nano-scale. E measurement reproducibility limit of 4% has been reached. This allows designing a very sensitive and reproducible measurement of E in biological samples representing thus a powerful diagnostic tool for cancer detection.


Assuntos
Dimetilpolisiloxanos , Módulo de Elasticidade/fisiologia , Microscopia de Força Atômica/métodos , Elasticidade/fisiologia , Humanos , Neoplasias/diagnóstico , Neoplasias/fisiopatologia , Reprodutibilidade dos Testes
10.
Cytometry A ; 87(3): 254-61, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25655377

RESUMO

This report focuses on the characterization of CD4 expression level in terms of equivalent number of reference fluorophores (ERF). Twelve different flow cytometer platforms across sixteen laboratories were utilized in this study. As a first step the participants were asked to calibrate the fluorescein isothiocyanate (FITC) channel of each flow cytometer using commercially available calibration standard consisting of five populations of microspheres. Each population had an assigned value of equivalent fluorescein fluorophores (EFF denotes a special case of the generic term ERF with FITC as the reference fluorophore). The EFF values were assigned at the National Institute of Standards and Technology (NIST). A surface-labelled lyophilized cell preparation was provided by the National Institute of Biological Standards and Control (NIBSC), using human peripheral blood mononuclear cells (PBMC) pre-labeled with a FITC conjugated anti-CD4 monoclonal antibody. Three PBMC sample vials, provided to each participant, were used for the CD4 expression analysis. The PBMC are purported to have a fixed number of surface CD4 receptors. On the basis of the microsphere calibration, the EFF value of the PBMC samples was measured to characterize the population average CD4 expression level of the PBMC preparations. Both the results of data analysis performed by each participant and the results of centralized analysis of all participants' raw data are reported. Centralized analysis gave a mean EFF value of 22,300 and an uncertainty of 750, corresponding to 3.3% (level of confidence 68%) of the mean EFF value. The next step will entail the measurement of the ERF values of the lyophilized PBMC stained with labels for other fluorescence channels. The ultimate goal is to show that lyophilized PBMC is a suitable biological reference cell material for multicolor flow cytometry and that it can be used to present multicolor flow cytometry measurements in terms of ABC (antibodies bound per cell) units.


Assuntos
Antígenos CD4/biossíntese , Fluoresceína-5-Isotiocianato , Leucócitos Mononucleares/metabolismo , Fenótipo , Anticorpos/análise , Anticorpos/metabolismo , Antígenos CD4/análise , Contagem de Linfócito CD4/métodos , Contagem de Linfócito CD4/normas , Fluoresceína-5-Isotiocianato/análise , Liofilização/métodos , Regulação da Expressão Gênica , Humanos , Leucócitos Mononucleares/química
11.
Water Environ Res ; 86(1): 28-35, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24617107

RESUMO

Local diary sludge as a biosorbent was used in this study for lead ion adsorption from aqueous solution. Batch experiments were carried out as a function of temperature, initial concentration, and ionic strength. Lead uptake was significantly enhanced from 149 to 224 mg/g of dairy sludge by a temperature increase at pH 5. Equilibrium data for metal ion adsorption were analyzed using model equations, namely Langmuir and Freundlich isotherms, and the best fit to the experimental data was provided by the first isotherm model. Brunauer-Emett-Teller and Fourier transform infrared analyses were also performed to characterize the biosorbent. Ionic strength using NaCl, NaNO3, and Ca(NO3)2 did not affect Pb(+2) sorption, while there was a 20% decrease using CaCl2. A limited effect of Cd(+2) ions present in the binary system on lead sorption was observed. This study shows that this local dairy sludge can be an alternative to the commercially available adsorbents for the removal of heavy metals from liquid effluents.


Assuntos
Chumbo/isolamento & purificação , Esgotos , Termodinâmica , Poluentes Químicos da Água/isolamento & purificação , Adsorção , Biomassa , Indústria de Laticínios , Concentração de Íons de Hidrogênio
12.
Chem Commun (Camb) ; 50(41): 5413-30, 2014 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-24647618

RESUMO

Organic electrochromic materials have gained constantly increasing interest over the years with respect to their inorganic counterpart due to essentially two distinctive characteristics: their processability through solution based low cost processes and their wide colour palette. Such characteristic features enabled their application in displays, smart windows, electronic paper and ophthalmic lenses. Alongside the established concept of donor-acceptor polymers, side chain functionalized multichromophoric polymers are gaining attention as a highly performing and synthetically feasible alternative, particularly relevant to applications requiring a complete colourlessness in one of the accessible redox states of the material. The primary aim of the present article is to review all the results involving the tuning of the native electrochromic properties of simple conjugated polymers through the introduction of a discrete electrochromic molecule as a side chain substituent.

13.
J Phys Condens Matter ; 25(6): 065504, 2013 Feb 13.
Artigo em Inglês | MEDLINE | ID: mdl-23315221

RESUMO

Using (90)Sr as a representative isotope, we present a framework for understanding beta decay within the solid state. We quantify three key physical and chemical principles, namely momentum-induced recoil during the decay event, defect creation due to physical displacement, and chemical evolution over time. A fourth effect, that of electronic excitation, is also discussed, but this is difficult to quantify and is strongly material dependent. The analysis is presented for the specific cases of SrTiO(3) and SrH(2). By comparing the recoil energy with available threshold displacement data we show that in many beta-decay situations defects such as Frenkel pairs will not be created during decay as the energy transfer is too low. This observation leads to the concept of chemical evolution over time, which we quantify using density functional theory. Using a combination of Bader analysis, phonon calculations and cohesive energy calculations, we show that beta decay leads to counter-intuitive behavior that has implications for nuclear waste storage and novel materials design.


Assuntos
Evolução Química , Hidrogênio/química , Modelos Químicos , Óxidos/química , Estrôncio/química , Titânio/química , Partículas beta , Transferência de Energia , Teoria Quântica
14.
Acta Neurochir (Wien) ; 154(11): 2029-41, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22961243

RESUMO

BACKGROUND: Eighteen patients with severe and refractory Tourette Syndrome underwent bilateral thalamic deep brain stimulation. The surgical procedures and stimulation processes of the cohort were reported in 2008; the 2 year follow-up was reported in 2009. The aim of the research is the assessment of long-term outcome (5-6 years) on tics, obsessional behaviours, anxiety, mood, and on the overall general health of the patients and their general satisfaction. METHOD: In this study, all 18 of the original patients will be discussed, pre- and post-DBS, according to our protocol using standardized objective schedules, as well as the clinical impressions of both clinicians and patients. As there were no substantial nor statistical differences on measures of cognitive functioning between pre-DBS and 2 year follow-up, we decided not to continue this aspect of the formal assessment, particularly as there were also no clinical indications. RESULTS: At 5-6 year follow-up, there was a significant reduction in tic severity (p < 0.001), and significant improvements in obsessive compulsive behaviours (p = 0.003), anxiety (p < 0.001) and depressive (p < 0.001) symptoms. Patients, in general, required less medication for tics, co-morbid conditions and/or co-existent psychopathologies. The long-term outcome/satisfaction were not unanimous between patients and the medical team. CONCLUSIONS: At long-term follow-up, DBS was very successful in terms of a significant improvement in tics and also a significant reduction in the potentially disabling symptoms of obsessionality, anxiety and depression. However, compared with our more positive overall results at 2 years, these later results demonstrate long-term difficulties as follows: non-compliance, long-term complications , and the differences in the opinions between the (a) medical, (b) the surgical teams and (c) the post-DBS patients as to their outcome/satisfaction with the procedures. Our experience highlights the need for controlled studies, for long-term follow up, and the need to improve the selection of patients for DBS.


Assuntos
Estimulação Encefálica Profunda/métodos , Tiques/terapia , Síndrome de Tourette/terapia , Adolescente , Adulto , Ansiedade/terapia , Seguimentos , Humanos , Pessoa de Meia-Idade , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
15.
Rev Med Interne ; 33(7): 401-4, 2012 Jul.
Artigo em Francês | MEDLINE | ID: mdl-22658166

RESUMO

INTRODUCTION: Acquired hemophilia A (AH) is a rare hemorrhagic disorder, secondary to the occurrence of factor VIII inhibitor. In young patients, this disorder is commonly observed during the post-partum period, and has been rarely documented in the prepartum. We report a new case of a prepartum AH and review literature data. CASE REPORT: An isolated prolongation of the activated partial thromboplastin time (APTT) was fortuitously discovered in a 31-year-old pregnant women, with spontaneous ecchymosis of her lower limbs few days prior to delivery. Coagulation tests revealed decreased factor VIII activity (18%) and the presence of factor VIII inhibitor (1,4 Bethesda unit). In order to eradicate the autoantibody, the patient was first treated with prednisone and then with rituximab. CONCLUSION: Prepartum factor VIII inhibitors need to be precociously recognized to allow prophylactic management of the delivery bleeding.


Assuntos
Fator VIII/antagonistas & inibidores , Hemofilia A/diagnóstico , Complicações Hematológicas na Gravidez/diagnóstico , Adulto , Coagulação Sanguínea , Equimose/etiologia , Fator VIII/imunologia , Feminino , Humanos , Tempo de Tromboplastina Parcial , Gravidez
16.
Ann Dermatol Venereol ; 139(1): 54-7, 2012 Jan.
Artigo em Francês | MEDLINE | ID: mdl-22225744

RESUMO

BACKGROUND: Dowling-Degos disease is a rare and benign inherited dermatosis. PATIENTS AND METHODS: A 53-year-old woman presented with generalized histologically confirmed Dowling-Degos disease revealed 8 years after psoralen photochemotherapy (PUVA) for psoriasis. This presentation was special in terms of its considerable spread as well as the absence of comedone-like and punctate scars. DISCUSSION: Dowling-Degos disease is a reticulate pigmentary disorder of the flexures associating prominent comedone-like lesions and pitted scars. Diagnosis is based on clinical and histopathological examination, which allows this entity to be differentiated from other reticulate pigmentary disorders. A literature review failed to provide any indication that PUVA therapy either aggravates or reveals Dowling-Degos disease, a finding which we feel merits mention.


Assuntos
Melanose/complicações , Terapia PUVA/efeitos adversos , Psoríase/tratamento farmacológico , Acitretina/uso terapêutico , Genes Dominantes , Humanos , Queratina-5/genética , Melanose/diagnóstico , Melanose/genética , Melanose/patologia , Melanossomas/patologia , Pessoa de Meia-Idade , Penetrância , Psoríase/complicações , Psoríase/patologia , Raios Ultravioleta/efeitos adversos
17.
G Ital Med Lav Ergon ; 34(3 Suppl): 275-7, 2012.
Artigo em Italiano | MEDLINE | ID: mdl-23405640

RESUMO

Unbiased estimates of incidence rates of accidents with blood contaminations (ABC) and time trends is the milieu for assessing the effectiveness of preventive interventions. A standardised procedure for registration and follow-up of ABC was et up in a North Italian hospital since 2002. Accurate estimates of rate denominator, as full-time equivalent (FTE) person-years, was calculated, for exposed workers only and excluding periods of prolonged absence. In the observation period (2004-2011), training courses for head nurses on security procedures were repeatedly carried out as well as the progressive introduction of vacuum blood collection systems (since 2009). 1287 ABC have been reported, corresponding to an overall annual crude incidence rate of 4.73 per 100 FTE. Temporal trends, calculated on the biennial incidence, resulted in a reductions over the time period considered, in particular for needlestick injuries. Our results support the notions on the efficacy of the adopted prevention measures.


Assuntos
Acidentes de Trabalho/estatística & dados numéricos , Acidentes de Trabalho/tendências , Patógenos Transmitidos pelo Sangue , Hospitais de Ensino , Adulto , Feminino , Humanos , Incidência , Itália , Masculino , Ferimentos Penetrantes Produzidos por Agulha , Fatores de Tempo
18.
Arch Pediatr ; 18(1): 23-7, 2011 Jan.
Artigo em Francês | MEDLINE | ID: mdl-20952167

RESUMO

Dermatofibrosarcoma protuberans (DFSP) is a relatively rare skin neoplasm. Usually affecting adults, the incidence in children is even less frequent. Through a report of three pediatric cases of DFSP, we describe the particularities of this tumor in children. Three boys aged 8, 9, and 15 years presented with a firm nodular skin lesion of the trunk, varying in size from 1 to 5 cm. No previous trauma event had occurred. Diagnosis was confirmed in all cases by immunohistological study. Surgical excision was performed in all cases. No recurrence was evident during the follow-up period of, respectively, 15, 36, and 49 months. The DFSP is an infiltrative tumor of intermediate malignancy, with a limited potential for metastasis (<5%) but a high rate of local recurrence (≥ 50%). The incidence in children is even less frequent. In children, its seemingly benign clinical appearance may explain delays in diagnosis; the majority of lesions affect the extremities, suggesting a potential role-played by injury. In our observations, however, as in adults, the trunk was the site of occurrence. Despite the uncertain pathogenesis of this tumor, the finding of certain characteristic histopathological features helps establish an accurate diagnosis. As in adults, surgical treatment with large surgical margins remains the best practice for children with DFSP, directly affecting the prognosis.


Assuntos
Dermatofibrossarcoma , Neoplasias Cutâneas , Adolescente , Criança , Dermatofibrossarcoma/patologia , Dermatofibrossarcoma/cirurgia , Humanos , Masculino , Neoplasias Cutâneas/patologia , Neoplasias Cutâneas/cirurgia
20.
Br J Health Psychol ; 15(Pt 3): 479-510, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-19840495

RESUMO

OBJECTIVES: This qualitative study aims at understanding the consequences of body deconstruction through mastectomy on corporality and identity in women with breast cancer. DESIGN: Nineteen women were contacted through the hospital. All had to undergo mastectomy. Some were offered immediate breast reconstruction, others, because of cancer treatments, had no planned reconstruction. A qualitative reflexive methodological background was chosen. METHOD: Women were invited to participate in three semi-structured interviews, one shortly before or after mastectomy, and the other interviews later in their illness courses, after surgery. All interviews were transcribed verbatim. Thematic analysis was performed. The analysis of the first interview of each woman is presented in this article. RESULTS: Mastectomy provokes a painful experience of body deconstruction. Even when immediate reconstruction is proposed, contrasted feelings and dissonance are expressed when comparing the former healthy body to the present challenged body entity. Body transformations are accompanied with experiences of mutilation, strangeness, and modify the physical, emotional social, symbolic and relational dimensions of the woman's gendered identity. Although the opportunity of breast reconstruction is seen as a possible recovery of a lost physical symmetry and body integrity, grieving the past body and integrating a new corporality leads to a painful identity crisis. CONCLUSION: With mastectomy, the roots of the woman's identity are challenged, leading to a re-evaluation of her existential values. The consequences of mastectomy transform the woman's corporality and embodiment, and question her identity. Psychological support is discussed in the perspective of our results.


Assuntos
Imagem Corporal , Neoplasias da Mama/psicologia , Neoplasias da Mama/cirurgia , Carcinoma Ductal/psicologia , Carcinoma Ductal/cirurgia , Carcinoma Intraductal não Infiltrante/psicologia , Carcinoma Intraductal não Infiltrante/cirurgia , Carcinoma Lobular/psicologia , Carcinoma Lobular/cirurgia , Identidade de Gênero , Crise de Identidade , Mamoplastia/psicologia , Mastectomia Segmentar/psicologia , Mastectomia/psicologia , Adaptação Psicológica , Adulto , Feminino , Pesar , Humanos , Entrevista Psicológica , Pessoa de Meia-Idade , Pesquisa Qualitativa , Reoperação/psicologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...