Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Methods Mol Biol ; 2100: 189-198, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31939124

RESUMO

The development of enzyme immobilization techniques that will not affect catalytic activity and conformation is an important research task. Affinity tags that are present or added at a specific position far from the active site in the structure of the native enzyme could be used to create strong affinity bonds between the protein structure and a surface functionalized with the complementary affinity ligand. These immobilization techniques are based on affinity interactions between biotin and (strept)avidin molecules, lectins and sugars, or metal chelate and histidine tag.Recent developments involve immobilization of tagged enzymes onto magnetic nanoparticles. These supports can improve the performance of immobilized biomolecules in analytical assay because magnetic beads provide a relative large numbers of binding sites for biochemical reactions resulting in faster assay kinetics.This chapter describes immobilization procedures of tagged enzymes onto various magnetic beads.


Assuntos
Enzimas Imobilizadas/química , Imãs , Microesferas , Sítios de Ligação , Biotina/química , Carboidratos/química , Catálise , Domínio Catalítico , Ativação Enzimática , Íons/química , Cinética , Metais/química , Ligação Proteica
2.
Anal Bioanal Chem ; 406(23): 5657-67, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24939134

RESUMO

This paper reports on electrochemiluminescent sensors and biosensors based on polyluminol/hydrogel composite sensing layers using chemical or biological membranes as hydrogel matrices. In this work, luminol is electropolymerized under near-neutral conditions onto screen-printed electrode (SPE)-supported hydrogel films. The working electrode coated with a hydrogel film is soaked in a solution containing monomeric luminol units, allowing the monomeric luminol units to diffuse inside the porous matrix to the electrode surface where they are electropolymerized by cyclic voltammetry (CV). Sensors and enzymatic biosensors for H2O2 and choline detection, respectively, have been developed, using choline oxidase (ChOD) as a model enzyme. In this case, hydrogel is used both as the enzymatic immobilization matrix and as a template for the electrosynthesis of polyluminol. The enzyme was immobilized by entrapment in the gel matrix during its formation before electropolymerization of the monomer. Several parameters have been optimized in terms of polymerization conditions, enzyme loading, and average pore size. Using calcium alginate or tetramethoxysilane (TMOS)-based silica as porous matrix, H2O2 and choline detection are reported down to micromolar concentrations with three orders of magnitude wide dynamic ranges starting from 4 × 10(-7) M. Polyluminol/hydrogel composites appear as suitable electrochemiluminescence (ECL)-active sensing layers for the design of new reagentless and disposable easy-to-use optical sensors and biosensors, using conventional TMOS-based silica gel or the more original and easier to handle calcium alginate, reported here for the first time in such a configuration, as the biocompatible hydrogel matrix.


Assuntos
Técnicas Biossensoriais/instrumentação , Hidrogel de Polietilenoglicol-Dimetacrilato/química , Medições Luminescentes/instrumentação , Luminol/química , Polímeros/química , Oxirredutases do Álcool/química , Técnicas Biossensoriais/métodos , Enzimas Imobilizadas/química , Peróxido de Hidrogênio/química , Medições Luminescentes/métodos , Polímeros/síntese química
3.
Methods Mol Biol ; 1051: 139-48, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23934803

RESUMO

The development of enzyme immobilization techniques that will not affect catalytic activity and conformation is an important research task. Affinity tags that are present or added at a specific position far from the active site in the structure of the native enzyme could be used to create strong affinity bonds between the protein structure and a surface functionalized with the complementary affinity ligand. These immobilization techniques are based on affinity interactions between biotin and (strept)avidin molecules, lectins and sugars, or metal chelate and histidine tag. Recent developments involve immobilization of tagged enzymes onto magnetic nanoparticles. These supports can improve the performance of immobilized biomolecules in analytical assay because magnetic beads provide a relative large numbers of binding sites for biochemical reactions resulting in faster assay kinetics. This chapter describes immobilization procedures of tagged enzymes onto various magnetic beads.


Assuntos
Enzimas Imobilizadas/química , Nanopartículas de Magnetita/química , Quelantes/química , Histidina/química , Fenômenos Magnéticos , Níquel/química , Ácido Nitrilotriacético/química , Oligopeptídeos/química , Lectinas de Plantas/química , Ligação Proteica , Estreptavidina/química
4.
Methods Mol Biol ; 1051: 209-16, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23934806

RESUMO

This paper describes a novel, simple, and versatile protocol for covalent immobilization of enzyme on electrode. The immobilization method is based on the combination of diazonium salt electrografting and click chemistry. The ethynyl-terminated monolayers are obtained by diazonium salt electrografting, then, in the presence of copper (I) catalyst, the ethynyl modified surfaces reacts efficiently and rapidly with enzyme bearing an azide function (azido-enzyme), thus forming a covalent 1,2,3-triazole linkage by means of click chemistry. The ethynyl-terminated film preserves the activity of the immobilized enzyme. The click chemistry along with binary film of diazonium salts offers a variety of good characteristics including high sensitivity, good repeatability and reusability, rapid response and long term stability of the system. Thus, because of the chemoselective reactivity and quantitative yield of the click reaction, an ethynyl-terminated monolayer can be treated as a general platform for obtaining reliable coverage of a wide range of azido-terminated species of interest for various sensing applications.


Assuntos
Alcinos/química , Química Click , Reagentes de Ligações Cruzadas/química , Enzimas Imobilizadas/química , Azidas/química , Técnicas Biossensoriais , Reação de Cicloadição , Eletrodos , Prata/química , Compostos de Trimetilsilil/química
5.
Methods Mol Biol ; 1051: 229-39, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23934808

RESUMO

This chapter provides a detailed description of the three immobilization methods based on the biomolecules entrapment into polymer matrices. The poly (vinyl alcohol) bearing styrylpyridinium groups (PVA-SbQ), a soluble pre-polymer bearing photo-cross-linkable groups, has widely been used to entrap enzymes, and several bioassays based on this immobilization matrix have been reported. Similarly, immobilization of enzymes via sol-gel has been described in this chapter. Sol-gel process is based on the ability to form solid metal or semi-metal oxides via the aqueous process of hydrolytically labile precursors. Enzymes can also be entrapped in an agarose gel. Contrary to synthetic polymers such as polyacrylamide, this matrix is biocompatible, non-toxic, provides natural microenvironment to the enzyme and also gives sufficient accessibility to electrons to shuttle between the enzyme and the electrode. The entrapment strategies are easy-to-perform, and permit to deposit enzyme, mediators, and additives in the same sensing layer. Moreover, the activity of the enzyme is preserved during the immobilization process, as biological element is not modified. Biosensors based on physically entrapped enzymes are often characterized by increased operational and storage stability.


Assuntos
Enzimas Imobilizadas/química , Acetilcolinesterase/química , Técnicas Biossensoriais , Reagentes de Ligações Cruzadas/química , Estabilidade Enzimática , Géis/química , Transição de Fase , Polimerização , Álcool de Polivinil/química , Compostos de Piridínio/química , Sefarose/química , Soluções
6.
Talanta ; 105: 306-16, 2013 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-23598023

RESUMO

Diarrheic Shellfish Poisoning (DSP) is a gastrointestinal illness caused by consumption of shellfish contaminated with DSP toxins such as okadaic acid (OA) and dinophysistoxins (DTX). The occurrences of OA in bivalves induce not only public health problems but also economic damages to shellfish farming. Consequently, the development of fast, reliable and sensitive detection methods is an evident necessity. The mouse bioassay has been the reference and most commonly used analysis method. However, this technique suffers from low accuracy, specificity and ethical problems due to the animal experimentation. Thus, the development of alternative and efficient detection systems is required. Several biological, chemical, and immunological methods have been developed to evaluate the presence of DSP toxins in seafood. This review gives an overview of different analytical methods and new trends for the detection of OA. Over the past decade, considerable attention has been given to the development of biosensors for the efficient detection of marine toxin. Recent advances in the field of aptamers and nanomaterial offer exciting new opportunities to develop improved and more reliable devices allowing the detection of OA.


Assuntos
Biologia Marinha , Ácido Okadáico/toxicidade , Alimentos Marinhos/análise , Cromatografia Líquida , Eletroforese Capilar , Espectrometria de Massas , Espectrometria de Fluorescência
7.
Talanta ; 103: 14-9, 2013 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-23200352

RESUMO

The aptamer immobilization onto organized mixed layers of diazonium salts via click chemistry was explored. The immobilized aptamer was employed in the fabrication of a highly sensitive and reusable electrochemical impedimetric aptasensor for the detection of ochratoxin A (OTA). The screen-printed carbon electrodes (SPCEs) were first modified by electrografting of a protected 4-((trimethylsilyl)ethynyl) benzene (TMSi-Eth-Ar) layer followed by a second one of p-nitrobenzene (p-NO(2)-Ar) by means of electrochemical reduction of their corresponding diazonium salts, (TMSi-Eth-Ar-N(2)(+)) and (p-NO(2)-ArN(2)(+)). After deprotection, a layer with active ethynyl groups was obtained. In the presence of copper (I) catalyst, the ethynyl groups reacted efficiently with aptamer bearing an azide function, thus forming a covalent 1,2,3-triazole linkage. Cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) in the presence of ferri/ferrocyanide redox probe [Fe(CN)(6)](4-/3-) were used to characterize each step in the aptasensor development. The increase in electron-transfer resistance (R(et)) values due to the specific aptamer-OTA interaction was proportional to the concentration of OTA in a range between 1.25 ng/L and 500 ng/L, with a detection limit of 0.25 ng/L.


Assuntos
Aptâmeros de Nucleotídeos/química , Azidas/química , Técnicas Biossensoriais , Química Click , Espectroscopia Dielétrica , Ocratoxinas/análise , Cerveja/análise , Carbono/química , Catálise , Eletrodos
8.
Talanta ; 99: 232-7, 2012 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-22967546

RESUMO

An electrochemical immunosensor for okadaic acid (OA) detection has been developed, and used in an indirect competitive immunoassay format under automated flow conditions. The biosensor was fabricated by injecting OA modified magnetic beads onto screen printed carbon electrode (SPCE) in the flow system. The OA present in the sample competed with the immobilized OA to bind with anti-okadaic acid monoclonal antibody (anti-OA-MAb). The secondary alkaline phosphatase labeled antibody was used to perform electrochemical detection. The current response obtained from the labeled alkaline phosphatase to 1-naphthyl phosphate decreased proportionally to the concentration of free OA in the sample. The calculated limit of detection (LOD) was 0.15 µg/L with a linear range of 0.19-25 µg/L. The good recoveries percentages validated the immunosensor application for real mussel samples. The developed system automatically controlled the incubation, washing and current measurement steps, showing its potential use for OA determination in field analysis.


Assuntos
Técnicas Biossensoriais/métodos , Bivalves/química , Eletroquímica/métodos , Análise de Injeção de Fluxo/métodos , Imunoensaio/métodos , Ácido Okadáico/análise , Animais , Automação , Monitoramento Ambiental , Imãs , Microesferas , Sistemas On-Line
9.
Anal Chim Acta ; 724: 92-7, 2012 Apr 29.
Artigo em Inglês | MEDLINE | ID: mdl-22483215

RESUMO

Okadaic acid (OA), a lipophilic phycotoxin is mainly produced by toxigenic dinoflagellates. The need to develop high performing methods for OA analysis able to improve the traditional ones is evident. In this work, a novel experimental methodology for label-free detection of OA was developed. Protein G magnetic beads (protein-G-MBs) modified gold electrode was used to immobilize anti-OA monoclonal antibody (anti-OA-MAb). Preliminary, colorimetric tests were performed in order to validate protein-G-MBs and anti-OA-MAb reaction. Electrochemical detection was carried out by differential pulse voltammetry in ferri/ferrocyanide solution. The limit of detection value obtained (0.5 µg L(-1)) validated the developed electrochemical immunosensor as a promising tool for routine use. The matrix effect and the recovery rate were also assessed with real samples, showing a good percentage of recovery.


Assuntos
Técnicas Biossensoriais/métodos , Bivalves/química , Ácido Okadáico/análise , Animais , Anticorpos Imobilizados/química , Anticorpos Imobilizados/imunologia , Anticorpos Monoclonais/química , Anticorpos Monoclonais/imunologia , Proteínas de Bactérias/química , Proteínas de Bactérias/imunologia , Calibragem , Colorimetria , Eletroquímica , Eletrodos , Ferricianetos/química , Ferrocianetos/química , Ouro/química , Limite de Detecção , Nanopartículas de Magnetita/química
10.
Biotechnol Adv ; 30(3): 489-511, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-21951558

RESUMO

Immobilization of enzymes on the transducer surface is a necessary and critical step in the design of biosensors. An overview of the different immobilization techniques reported in the literature is given, dealing with classical adsorption, covalent bonds, entrapment, cross-linking or affinity as well as combination of them and focusing on new original methods as well as the recent introduction of promising nanomaterials such as conducting polymer nanowires, carbon nanotubes or nanoparticles. As indicated in this review, various immobilization methods have been used to develop optical, electrochemical or gravimetric enzymatic biosensors. The choice of the immobilization method is shown to represent an important parameter that affects biosensor performances, mainly in terms of sensitivity, selectivity and stability, by influencing enzyme orientation, loading, mobility, stability, structure and biological activity.


Assuntos
Técnicas Biossensoriais/métodos , Técnicas Eletroquímicas/métodos , Enzimas Imobilizadas/química , Polímeros/química , Adsorção , Técnicas Biossensoriais/classificação , Estrutura Molecular , Nanoestruturas/química , Transição de Fase
11.
Talanta ; 85(5): 2498-503, 2011 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-21962674

RESUMO

A colorimetric protein phosphatase (PP) inhibition test for the detection of microcystin-LR (MC-LR) has been developed. Three PP2As, one recombinant and two natural versions, as well as one PP1 produced by molecular engineering, were tested. First, assays were performed using the enzymes in solution to compare their sensitivity to MC-LR. The PP2A purchased from ZEU Immunotec and PP1 appeared more sensitive to the toxin than the other enzymes. With PP2A from ZEU Immunotec, the colorimetric test showed a detection limit of 0.0039 µg L(-1) and an IC(50) value of 0.21 µg L(-1). With PP1, the assay gave a detection limit of 0.05 µg L(-1) and an IC(50) value of 0.56 µg L(-1). Therefore, this assay allowed the detection of lower microcystin-LR (MC-LR) concentrations than the maximum level (1 µg L(-1)) recommended by the World Health Organisation (WHO). The main drawback of this PP-based approach in solution is poor enzyme stabilisation. To overcome this problem, enzymes were entrapped within either a photopolymer or an agarose gel. PP2A from ZEU Immunotec and PP1 were immobilised at the bottom of microwells. The agarose-based tests performed better than the photopolymer-based assay for all of the enzymes. Therefore, the agarose gel is a good candidate to replace the photopolymer, which is generally used in PP-immobilising membranes. The assays based on enzyme-entrapping agarose gels showed detection limits equal to 0.17 µg L(-1) and 0.29 µg L(-1) with immobilised PP2A from ZEU and PP1, respectively. In view of these performances, these tests can potentially be used for monitoring water quality.


Assuntos
Colorimetria , Microcistinas/análise , Fosfoproteínas Fosfatases/metabolismo , Concentração Inibidora 50 , Toxinas Marinhas , Microcistinas/farmacologia , Sefarose
12.
Anal Chim Acta ; 702(2): 262-8, 2011 Sep 30.
Artigo em Inglês | MEDLINE | ID: mdl-21839207

RESUMO

Okadaic acid (OA), responsible for gastrointestinal problems, inhibits protein phosphatase 2A (PP2A). Therefore, the inhibition exerted by the toxin on PP2A could be used to detect the presence of OA in aqueous solution and in shellfish sample. In this work, two commercial PP2As (from ZEU Immunotec and Millipore) and one produced by molecular engineering (from GTP Technology) were tested. Enzymes were used in solution and also immobilized within a polymeric gel. In solution, best performances were obtained using PP2A purchased from ZEU Immunotec (Spain). OA was detected in aqueous solution in concentration as low as 0.0124 µg L(-1) using the enzyme from ZEU Immunotec whereas the detection limits were 0.47 µg L(-1) and 0.123 µg L(-1) with PP2As from Millipore and GTP Technology, respectively. Considering that the immobilization step contributes to stabilize the PP2A activity, enzymes were entrapped within a photopolymer and an agarose gel. These different polymeric matrices were optimized, tested and compared. Agarose gel seems to be a good alternative to the photopolymer largely used in our group. For instance, the IC(50) value obtained with the test based on PP2A from ZEU Immunotec immobilized within an agarose gel was 1.98 µg L(-1). This value was 1.8-fold lower than those obtained with the photopolymer test using the same enzyme. The proposed test is sensitive, fast and does not require expensive equipment. To evaluate the efficiency of the assay, PP inhibition tests based on PP2A from ZEU Immunotec in solution or immobilized within a gel were used for OA detection in contaminated shellfish.


Assuntos
Colorimetria/métodos , Inibidores Enzimáticos/análise , Toxinas Marinhas/análise , Ácido Okadáico/análise , Proteína Fosfatase 2/metabolismo , Animais , Bivalves/metabolismo , Inibidores Enzimáticos/toxicidade , Toxinas Marinhas/toxicidade , Ácido Okadáico/toxicidade , Fotoquímica , Proteína Fosfatase 2/antagonistas & inibidores , Sensibilidade e Especificidade , Sefarose/química , Soluções/química , Água/química
13.
Talanta ; 85(1): 513-8, 2011 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-21645734

RESUMO

In this work, an electrochemical method based on the diazonium-coupling reaction mechanism for the immobilization of okadaic acid (OA) on screen printed carbon electrode was developed. At first, 4-carboxyphenyl film was grafted by electrochemical reduction of 4-carboxyphenyl diazonium salt, followed by terminal carboxylic group activation by N-hydroxysuccinimide (NHS), N-(3-dimethylaminopropyle)-N'-ethyle-carbodiimide hydrochloride (EDC). Hexamethyldiamine was then covalently bound by one of its terminal amine group to the activated carboxylic group. The carboxyl group of okadaic acid was activated by EDC/NHS and then conjugated to the second terminal amine group on other side of the hexamethyldiamine through amide bond formation. After immobilization of OA, an indirect competitive immunoassay format was employed to detect OA. The immunosensor obtained using this novel approach allowed detection limit of 1.44 ng/L of OA, and was also validated with certified reference mussel samples.


Assuntos
Compostos de Diazônio/química , Técnicas Eletroquímicas/instrumentação , Imunoensaio/métodos , Impressão Molecular/métodos , Ácido Okadáico/isolamento & purificação , Adsorção , Animais , Bivalves/química , Eletrodos , Limite de Detecção , Ácido Okadáico/análise , Padrões de Referência
14.
Biosens Bioelectron ; 26(9): 3725-36, 2011 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-21419619

RESUMO

Advances in the development and the applications of optical biosensing systems based on immobilized aptamers are presented. These nucleic acid sequences have been used as new molecular recognition elements to develop heterogeneous assays, biosensors and microarrays. Among different detection modes that have been employed, optical ones which are described here are among the most used. Since their first report in 1996, numerous optical detection systems using aptamers and mainly based on fluorescence have been developed. Two main approaches have been used: label-based (using fluorophore, luminophore, enzyme, nanoparticles) or aptamer label-free detection systems (e.g. surface plasmon resonance, optical resonance). Most methods are based on a labeling approach. Some targets can be optically detected using not only colorimetry, chemiluminescence or the most developed fluorescence mode but also more recent non conventional optical methods such as surface plasmon-coupled directional emission (SPCDE). The first SPCDE-based aptasensor for thrombin detection has recently been reported in 2009. Aptasensors based on surface-enhanced Raman scattering spectroscopy (SERS) which presents advantages compared to fluorescence have also been described. Different label-free techniques have recently been shown to be suitable for developing performant aptasensors or aptamer-based microarrays, such as surface plasmon resonance (SPR), diffraction grating, evanescent-field-coupled (EFC) waveguide-mode, optical resonance or Brewster angle straddle interferometry (BASI). Important advances have been realized on optical aptamer-based detection systems that appear as highly efficient devices with enormous potential.


Assuntos
Aptâmeros de Nucleotídeos/química , Técnicas Biossensoriais/métodos , Dispositivos Ópticos , Ressonância de Plasmônio de Superfície/métodos , Colorimetria/métodos , Nanopartículas/química , Trombina/química , Trombina/isolamento & purificação
15.
Analyst ; 136(2): 257-74, 2011 Jan 21.
Artigo em Inglês | MEDLINE | ID: mdl-20949139

RESUMO

Aptamers are DNA or RNA oligonucleotides that can bind with high affinity and specificity to a wide range of targets such as proteins, metal ions or pathogenic microorganisms. Soluble aptamers and aptazymes have been used as sensing elements for developing homogeneous assays in a solution phase, the whole sensing process being carried out in a homogeneous solution. Contrary to most conventional heterogeneous assays that are time-consuming and labor-intensive, aptamer-based homogeneous assays are simple, easy-to-perform, rapid and do not require immobilization nor washing steps. To our knowledge, this review is the first entirely dedicated to aptamer-based homogeneous assays. Optical detection appears as the most developed technique. Colorimetry represents the simplest sensing mode that occupies a very important position among aptamer-based assays, involving gold nanoparticle aggregation (with unmodified or aptamer-modified gold NPs), the formation of HRP-mimicking DNAzyme with hemin, dye displacement or interactions with a cationic polymer. Fluorescence that is highly sensitive offers the most developed detection mode. Aptamers can be labeled or not, to give rise to turn-on or usually less sensitive turn-off fluorescent assays. Newly reported and thus less developed non-conventional magnetic resonance imaging (MRI) and electrochemistry also recently appeared in the literature, thrombin still remains the main detected target. Homogeneous assays based on aptazyme, an aptamer sequence connected to a known ribozyme motif, are also described in this review, involving optical detection, by colorimetry or fluorescence.


Assuntos
Aptâmeros de Nucleotídeos/metabolismo , Técnicas Biossensoriais/métodos , Animais , Aptâmeros de Nucleotídeos/química , Sequência de Bases , Colorimetria/métodos , Técnicas Eletroquímicas/métodos , Fluorescência , Humanos , Imageamento por Ressonância Magnética/métodos , Dados de Sequência Molecular , RNA Catalítico/metabolismo
16.
Anal Bioanal Chem ; 394(4): 971-80, 2009 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-19390845

RESUMO

Performant reagentless electrochemiluminescent (ECL) (bio)sensors have been developed using polymeric luminol as the luminophore. The polyluminol film is obtained by cyclic voltammetry (CV) on a screen-printed electrode either in a commonly used H(2)SO(4) medium or under more original near-neutral buffered conditions. ECL responses obtained after performing polymerization either at acidic pH or at pH 6 have been compared. It appears that polyluminol formed in near-neutral medium gives the best responses for hydrogen peroxide detection. Polymerization at pH 6 by cyclic voltammetry gives a linear range extending from 8 x 10(-8) to 1.3 x 10(-4) M H(2)O(2) concentrations. Based on this performant sensor for hydrogen peroxide detection, an enzymatic biosensor has been developed by associating the polyluminol film with an H(2)O(2)-producing oxidase. Here, choline oxidase (ChOD) has been chosen as a model enzyme. To develop the biosensor, luminol has been polymerized at pH 6 by CV, and then an enzyme-entrapping matrix has been formed on the above modified working electrode. Different biological (chitosan, agarose, and alginate) and chemical (silica gels, photopolymers, or reticulated matrices) gels have been tested. Best performances have been obtained by associating a ChOD-immobilizing photopolymer with the polyluminol film. In this case, choline can be detected with a linear range extending from 8 x 10(-8) to 1.3 x 10(-4) M.


Assuntos
Oxirredutases do Álcool/metabolismo , Técnicas Biossensoriais/métodos , Eletroquímica/instrumentação , Enzimas Imobilizadas/metabolismo , Medições Luminescentes/métodos , Luminol/química , Polímeros/química , Oxirredutases do Álcool/química , Colina/análise , Eletrodos , Enzimas Imobilizadas/química , Peróxido de Hidrogênio/análise , Concentração de Íons de Hidrogênio , Luminol/síntese química , Polímeros/síntese química , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
18.
Anal Bioanal Chem ; 390(3): 865-71, 2008 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-18060392

RESUMO

A performant reagentless electrochemiluminescent (ECL) detection system for H(2)O(2) is presented, based on an electropolymerized polyluminol film prepared under near-neutral conditions. Such an original polyluminol electrodeposition is reported for the first time and on a screen-printed electrode (SPE) surface. Electropolymerized luminol acts as an active luminophore of the electrochemiluminescent reaction, as the monomer does. Polymerization conditions have been optimized in order to obtain the best ECL responses to H(2)O(2). By performing electrodeposition in a potentiostatic mode, at 425 mV vs. Ag|AgCl, in 0.1 mol L(-1) phosphate/0.1 mol L(-1) KCl pH 6 and 1 mmol L(-1) luminol, with a total charge of 0.5 mC, the linear range for H(2)O(2) detection extends from 7.9 x 10(-8) mol L(-1) to 1.3 x 10(-3) mol L(-1). Such performant disposable reagentless easy-to-use miniaturized systems based on SPEs should be applicable to the electrochemiluminescent detection of many oxidase-substrate compounds.


Assuntos
Técnicas Biossensoriais , Eletroquímica/métodos , Luminescência , Luminol/química , Eletrodos , Desenho de Equipamento , Peróxido de Hidrogênio/química , Modelos Químicos , Oxigênio/química , Polímeros/química , Cloreto de Potássio/química , Potenciometria/métodos , Prata/química , Compostos de Prata/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...