1.
Case Rep Womens Health
; 31: e00333, 2021 Jul.
Artigo
em Inglês
| MEDLINE
| ID: mdl-34168964
RESUMO
BACKGROUND: While Gore-Tex® sutures have excellent handling and cause minimal fibroblast activity and a less inflammatory response compared with other materials, they carry a risk of persistent sinus tract formation. CASE: A patient underwent an autologous rectus fascial sling using Gore-Tex® and we describe a novel technique for identification and excision of the sinus tract. CONCLUSION: Preoperative imaging and staining of the sinus tract with methylene blue can aid in successful identification of the tract during surgery and may improve rates of successful treatment.