Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 550
Filtrar
1.
Circ Cardiovasc Interv ; : e014143, 2024 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-38853766

RESUMO

Bioprosthetic aortic valve thrombosis is frequently detected after transcatheter and surgical aortic valve replacement due to advances in cardiac computed tomography angiography technology and standardized surveillance protocols in low-surgical-risk transcatheter aortic valve replacement trials. However, evidence is limited concerning whether subclinical leaflet thrombosis leads to clinical adverse events or premature structural valve deterioration. Furthermore, there may be net harm in the form of bleeding from aggressive antithrombotic treatment in patients with subclinical leaflet thrombosis. This review will discuss the incidence, mechanisms, diagnosis, and optimal management of bioprosthetic aortic valve thrombosis after transcatheter aortic valve replacement and bioprosthetic surgical aortic valve replacement.

3.
Am J Cardiol ; 2024 Jun 11.
Artigo em Inglês | MEDLINE | ID: mdl-38871158

RESUMO

The benefit of mechanical circulatory support (MCS) with Impella (Abiomed, Inc., Danvers, MA) for high-risk percutaneous coronary intervention (HR-PCI) is uncertain. PROTECT III registry data showed improved outcomes with Impella compared to historical data (PROTECT II) but lacks a direct comparison to the HR-PCI cohort without Impella support. We retrospectively identified patients meeting PROTECT III inclusion criteria for HR-PCI and compared this group (NonIMP) to the outcomes data from the PROTECT III registry (IMP). Baseline differences were balanced using inverse propensity weighting (IPW). The co-primary outcome was major adverse cardiac events (MACE) in-hospital and at 90 days. A total of 283 high-risk patients who did not receive Impella support; 200 patients had at 90-day event ascertainment and were included in the IPW analysis and compared with 504 patients in the IMP group. After calibration, few residual differences remained between groups. The primary outcome was not different in-hospital (3.0% vs. 4.8%, p=0.403) but lower in NonIMP at 90 days (7.5% vs. 13.8%, p=0.033). Periprocedural vascular complications, bleeding, and transfusion rate were not different between groups; however, acute kidney injury occurred more frequently in the NonIMP group (10.5% vs. 5.4%, p=0.023). In conclusion, under identical HR-PCI inclusion criteria for Impella use in PROTECT III, an institutional non-Impella-supported HR-PCI cohort demonstrated similar MACE in-hospital but lower MACE at 90 days, while there was no signal for periprocedural harm with Impella use. These results do not support routine usage of Impella for HR-PCI patients.

4.
Artigo em Inglês | MEDLINE | ID: mdl-38769727

RESUMO

BACKGROUND: The Evolut self-expanding valve (SEV) systems (Medtronic), were designed to accommodate varying valve sizes and reduce paravalvular leak (PVL) while maintaining a low delivery profile. These systems have evolved between product generations, alongside valve deployment techniques changing over time. AIMS: This study aimed to examine whether these changes impacted clinical outcomes. METHODS: EPROMPT is a prospective, investigator-initiated, postmarketing registry of consecutive patients undergoing transfemoral transcatheter aortic valve replacement (TAVR) using the Evolut PRO/PRO+ SEV system. A total of 300 patients were divided into three consecutive cohorts of 100 patients according to implantation date (January to October 2018, November 2018 to July 2020, and August 2020 to November 2021). Procedural and clinical outcomes over these time periods were compared. RESULTS: Valve Academic Research Consortium (VARC)-2 device implantation success improved over time (70.0% vs. 78.0% vs. 88.8%, p = 0.01), with a similar trend for VARC-3 device success (94.7% vs. 81.7% vs. 96.8%, p < 0.001). PVL (all degrees) frequency was likewise reduced over time (31.0% vs. 17.0% vs. 19.2%, p = 0.04). Furthermore, a trend was noticed toward shorter procedure times and shorter length of stay. However, postprocedural pacemaker implantation rates did not significantly differ (15.2% vs. 21.1% vs. 14.0%, p = 0.43). CONCLUSION: During a 3-year period, we demonstrated better TAVR outcomes with newer SEV iterations, alongside changes in implantation techniques, which might result in better procedural and clinical outcomes. However, we did not see a significant change in peri-procedural pacemaker rates for SEV.

5.
J Am Heart Assoc ; 13(11): e032291, 2024 Jun 04.
Artigo em Inglês | MEDLINE | ID: mdl-38818933

RESUMO

BACKGROUND: Hemoglobin (Hgb) drop without bleeding is common among patients undergoing transcatheter aortic valve replacement; however, the clinical implications of significant Hgb drop have not been fully evaluated. METHODS AND RESULTS: Consecutive patients undergoing transcatheter aortic valve replacement at our institution from 2011 to 2021 were retrospectively reviewed. Three groups were assessed: no Hgb drop and no bleed (NoD-NoB [reference group]), Hgb drop with bleed, and Hgb drop and no bleed (D-NoB). Hgb drop was defined as ≥3 g/dL decrease from pre- to post-transcatheter aortic valve replacement. Outcomes of interest were in-hospital death and 1-year all-cause mortality. A total of 1851 cases with complete Hgb data were included: NoD-NoB: n=1579 (85.3%); D-NoB: n=49 (2.6%); Hgb drop with bleed: n=223 (12.6%). Compared with NoD-NoB, the D-NoB group was older (81.1 versus 78.9 years of age) with higher preprocedure Hgb (12.9 versus 11.7 g/dL). In-hospital death rate was higher among patients with D-NoB versus NoD-NoB (4.5% versus 0.8%, P<0.001) and similar to Hgb drop with bleed (4.5% versus 4.1%, P=0.999). Predictors of in-hospital death were D-NoB (odds ratio [OR], 3.45 [95% CI, 1.32-8.69]) and transfusion (OR, 10.6 [95% CI, 4.25-28.2]). Landmark survival analysis found that D-NoB experienced 1-year mortality rate comparable to NoD-NoB, whereas Hgb drop with bleed had higher midterm mortality (hazard ratio [HR], 3.2 [95% CI, 1.83-5.73]), and transfusion continued to impact mortality (HR, 2.5 [95% CI, 1.79-3.63]). CONCLUSIONS: Hgb drop without bleeding is common among patients undergoing transcatheter aortic valve replacement and may represent a higher risk of periprocedural death. Blood transfusion increases short- and midterm mortality risk in patients with and without bleeding, supporting a restrictive transfusion strategy.


Assuntos
Estenose da Valva Aórtica , Hemoglobinas , Mortalidade Hospitalar , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Masculino , Feminino , Idoso de 80 Anos ou mais , Idoso , Estudos Retrospectivos , Hemoglobinas/metabolismo , Hemoglobinas/análise , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/mortalidade , Fatores de Risco , Resultado do Tratamento , Medição de Risco/métodos
6.
Artigo em Inglês | MEDLINE | ID: mdl-38797580

RESUMO

BACKGROUND: Outflow graft obstruction (OGO) is an uncommon yet life-threatening complication in patients with left ventricular assist devices (LVADs). In this retrospective, single-center case series, we identify the baseline demographics and presenting features of patients who develop LVAD OGO and the procedural details and outcomes surrounding percutaneous endovascular intervention (PEI). METHODS: We conducted a retrospective review of patients with LVADs at our institution between January 2010 and February 2023 who developed OGO and were treated with PEI. Details of the PEI including procedure time, fluoroscopy time, contrast use, stent size, number of stents, change in gradient, and change in flow after intervention were collected. RESULTS: A total of 12 patients who had 14 cases of OGO were identified from January 2010 to February 2023. The average age at presentation was 64.78 years. Nine of the 14 cases occurred in male patients. Eleven of the 14 cases occurred with Heartware devices (2 recurrences), 2 in Heartmate 2 and 1 in Heartmate 3. Notable procedural details include a mean procedure time of 90.86 min and mean contrast use of 162.5 mL. The initial gradient across the OGO was reduced by an average of 72 %, to a mean post-PEI of 11.57 mmHg. The average number of stents to achieve this gradient was around 2.08, with the most common stent diameter being 10 mm. Thirty-day mortality after PEI was 7 % (1/14) in this high-risk patient population. CONCLUSION: In our single-center experience, PEI can be a safe and effective treatment for LVAD OGO.

7.
Artigo em Inglês | MEDLINE | ID: mdl-38719633

RESUMO

BACKGROUND: High-sensitivity troponin (hsTnI) is correlated with cardiac mortality; however, studies on the relationship of markedly elevated hsTnI with in-hospital mortality after cardiac surgery are sparse. Therefore, we aimed to define this relationship in order to help guide in-hospital, acute management of post-surgical patients. METHODS: We retrospectively analyzed all cardiac surgeries completed at our institution between January 2020 and June 2022 in which a peak hsTnI was noted to be >35× upper limit of normal (ULN = 34 ng/L). The primary outcome was in-hospital death. Subgroup analysis was performed to assess differences between coronary artery bypass grafting (CABG) and other cardiac surgeries. RESULTS: A total of 1382 cases met inclusion criteria. The patients' mean age was 64.8 years and 68.2 % were male. Median peak hsTnI after surgery was 4202 ng/L (interquartile ratio: 2427-7654). Univariate analysis of troponin level with mortality found that for every 1000 ng/L increase in hsTnI, odds of in-hospital death increased by 3.8 % (odds ratio [OR]: 1.038; 95 % confidence interval [CI] 1.027-1.050; p < 0.0001). In a multivariate model, troponin (OR 1.02; 95 % CI 1.01-1.04; p = 0.004) maintained a significant association with in-hospital death. CABG was associated with a lower risk of in-hospital death for any given hsTnI level up to 60,000 ng/L compared to other cardiac surgeries. CONCLUSION: Increasing hsTnI level is associated with increasing probability of in-hospital mortality and, therefore, serves as an additional, objective measure of risk to help guide in-hospital clinical management.

8.
Artigo em Inglês | MEDLINE | ID: mdl-38631936

RESUMO

BACKGROUND: Coronary microvascular dysfunction (CMD) is a prevalent condition among patients with cardiovascular risk factors, leading to a reduced quality of life and an increased risk of major adverse cardiovascular events. Novel invasive techniques have emerged to more accurately diagnose CMD. However, CMD's natural history remains poorly understood due to limited data. To address this knowledge gap, the Coronary Microvascular Disease Registry (CMDR) was established with the primary aim of standardizing comprehensive coronary functional testing and understanding of CMD. DESIGN: CMDR is a prospective, multicenter registry enrolling an unlimited number of consecutive subjects who undergo comprehensive invasive hemodynamic assessment of the entire coronary arterial vasculature. Patients undergoing acetylcholine provocation test for coronary vasospasm will also be included. Follow-up assessments will be conducted at 30 days and annually for up to 5 years. The primary endpoint is Canadian Cardiovascular Society angina grade over time. Secondary endpoints, including all-cause mortality, cardiovascular death, acute myocardial infarction, stroke, hospitalizations, medication changes, and subsequent coronary interventions, will be analyzed to establish long-term safety and clinical outcomes in patients undergoing invasive CMD assessment. SUMMARY: CMDR aims to characterize the clinical and physiologic profile of patients undergoing comprehensive invasive coronary functional testing, simultaneously providing crucial longitudinal information on the natural history and outcomes of these patients. This will shed light on CMD's course and clinical implications, which, in turn, holds the potential to significantly improve diagnostic and treatment strategies for CMD patients, ultimately leading to the enhancement of their overall prognosis and quality of life. CLINICAL TRIAL REGISTRATION: clinicaltrials.gov, NCT05960474.

9.
Catheter Cardiovasc Interv ; 103(6): 917-923, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38605682

RESUMO

The advent of excimer laser coronary atherectomy (ELCA) nearly four decades ago heralded a novel way to treat complex lesions, both coronary and peripheral, which were previously untraversable and thus untreatable. These complex lesions include heavily calcified lesions, ostial lesions, bifurcation lesions, chronic total occlusions, in-stent restenosis (including stent underexpansion), and degenerative saphenous vein grafts. We discuss the technology of ELCA, its indications, applications, and complications, and suggest the "MAXCon ELCA" technique for better outcomes without increased risk. Lastly, we present a case of MAXCon ELCA effectively treating a complex lesion.


Assuntos
Aterectomia Coronária , Angiografia Coronária , Doença da Artéria Coronariana , Lasers de Excimer , Humanos , Meios de Contraste , Doença da Artéria Coronariana/terapia , Doença da Artéria Coronariana/diagnóstico por imagem , Lasers de Excimer/uso terapêutico , Solução Salina/administração & dosagem , Resultado do Tratamento
11.
Cardiovasc Revasc Med ; 59: 9-13, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37550124

RESUMO

BACKGROUND/PURPOSE: The cusp overlap technique has standardized implantation for self-expanding valves with the goal of achieving more consistent implantation depths and lowering permanent pacemaker (PPM) implantation rates. We retrospectively compared short-term outcomes in patients undergoing transcatheter aortic valve replacement (TAVR) with a self-expanding valve implanted using the cusp overlap technique vs. the traditional coplanar technique in a large tertiary referral center. METHODS: We conducted a retrospective study among PPM-naïve patients who underwent TAVR using the CoreValve Evolut PRO/PRO+. We compared in-hospital PPM rates in patients who underwent TAVR using the cusp overlap technique vs. the coplanar technique. Additional outcomes included in-hospital all-cause mortality, stroke, major vascular complications, annular rupture, and >mild paravalvular leak. Furthermore, we compared outcomes over time to see whether there was evidence of a learning curve. RESULTS: Of the 528 patients included, 270 underwent TAVR using the coplanar technique and 258 underwent TAVR using the cusp overlap technique. The rate of new PPM implantation did not differ between cohorts (17.0 % vs. 16.7 %; p = 0.910). Additionally, rates of in-hospital all-cause mortality (0.0 % vs. 0.4 %; p = 0.328), stroke (3.7 % vs. 1.6 %; p = 0.124), major vascular complications (0.7 % vs. 1.2 %; p = 0.617), annular rupture (0.4 % vs. 0.0 %; p = 0.328) and >mild paravalvular leak (0.0 % vs. 0.4 %; p = 0.444) were similar. Our secondary analysis did not identify any evidence of a learning curve. CONCLUSIONS: The cusp overlap technique may not yield a reduction in PPM rates when compared with the coplanar technique. Other confounders should be explored to further minimize in-hospital PPM rates.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Marca-Passo Artificial , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estudos Retrospectivos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Fatores de Risco , Desenho de Prótese
12.
Cardiovasc Revasc Med ; 59: 76-80, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37689575

RESUMO

BACKGROUND: Computed tomography with fractional flow reserve (CT-FFR) is increasingly common in assessing coronary artery disease. CASE PRESENTATION: We report five cases of discrepancies that led to changes in treatment. CONCLUSIONS: This report highlights discordant findings between modalities, which should be considered during the diagnostic assessment of chest pain.


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Humanos , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/terapia , Angiografia Coronária/métodos , Sensibilidade e Especificidade , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Tomografia Computadorizada por Raios X/métodos , Angiografia por Tomografia Computadorizada/métodos , Valor Preditivo dos Testes , Estudos Retrospectivos
13.
Cardiovasc Revasc Med ; 58: 45-49, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37393190

RESUMO

PURPOSE: Explore gender disparities in patients undergoing transseptal puncture (TSP) for selected transcatheter cardiac intervention procedures. METHODS: Patients who underwent TSP from January 2015 through September 2021 were reviewed. Primary outcomes were procedural and in-hospital major adverse events. Secondary endpoints were procedural success and hospitalization length of stay (LOS) >1 day. Unadjusted and multivariable-adjusted logistic regression analyses were performed to assess gender differences for in-hospital adverse events. RESULTS: The study cohort comprised 510 patients (mean [SD] age, 74 [14.0] years); 246 women (48 %) underwent TSP for left atrial appendage occlusion (LAAO) or transcatheter edge-to-edge-repair (TEER). Compared with men, women were younger, had higher CHA2DS2-VASc scores, and were more likely to have had a prior ischemic stroke, but were less likely to have paroxysmal atrial fibrillation. After multivariable adjustment, there were no differences between genders in aborted or canceled procedures (odds ratio [OR]: 0.43; 95 % confidence interval [CI]: 0.10-1.96; p = 0.277), any adverse events (OR: 1.00; 95 % CI: 0.58-1.70; p = 0.98), major adverse events (OR: 1.60; 95 % CI: 0.90-2.80; p = 0.11), or death (OR: 1.00; 95 % CI: 0.20-5.00; p = 0.31). Subgroup analysis for LAAO procedures showed that at 30 days, women had higher rates of adverse events, major adverse cardiac events, and LOS >1 day. CONCLUSIONS: Men and women showed no differences in procedural success and in-hospital adverse outcomes in unadjusted analysis and after multivariable adjustment, despite women having a higher risk profile among patients undergoing TSP. However, compared with men, women undergoing LAAO experienced a higher rate of in-hospital adverse events irrespective of TSP.


Assuntos
Apêndice Atrial , Fibrilação Atrial , AVC Isquêmico , Acidente Vascular Cerebral , Humanos , Masculino , Feminino , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/terapia , Fibrilação Atrial/complicações , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/métodos , AVC Isquêmico/etiologia , Fatores de Tempo , Resultado do Tratamento , Acidente Vascular Cerebral/etiologia
14.
Int J Cardiol ; 395: 131431, 2024 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-37832606

RESUMO

BACKGROUND: Recent randomized studies have broadened the indication of transcatheter aortic valve replacement (TAVR) to also include low-surgical-risk patients. However, the data on self-expanding (SE) and balloon-expandable (BE) valves in low-risk patients remain sparse. METHODS: The current study is a post hoc analysis of combined data from both LRT 1.0 and 2.0 trials comparing BE and SE transcatheter heart valves. RESULTS: A total of 294 patients received a BE valve, and 102 patients received an SE valve. The 30-day clinical outcomes were similar across both groups except for stroke (4.9% vs. 0.7%, p = 0.014) and permanent pacemaker implantation (17.8% vs. 5.8%, p < 0.001), which were higher in the SE cohort than the BE cohort. No difference was observed in terms of paravalvular leak (≥moderate) between the groups (0% vs. 1.5%, p = 0.577). SE patients had higher aortic valve area (1.92 ± 0.43 mm2 vs. 1.69 ± 0.45 mm2, p < 0.001) and lower mean gradient (8.93 ± 3.53 mmHg vs. 13.41 ± 4.73 mmHg, p < 0.001) than BE patients. In addition, the rate of subclinical leaflet thrombosis was significantly lower in SE patients (5.6% vs. 13.8%, p = 0.038). CONCLUSION: In this non-randomized study assessing SE and BE valves in low-risk TAVR patients, SE valves are associated with better hemodynamics and lesser leaflet thrombosis, with increased rates of stroke and permanent pacemaker implantation at 30 days; however, this could be due to certain patient-dependent factors not fully evaluated in this study. The long-term implications of these outcomes on structural valve durability remain to be further investigated. CLINICAL TRIAL REGISTRY: LRT 1.0: NCT02628899 LRT 2.0: NCT03557242.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Acidente Vascular Cerebral , Trombose , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/etiologia , Acidente Vascular Cerebral/etiologia , Trombose/etiologia , Resultado do Tratamento , Desenho de Prótese , Fatores de Risco
17.
Am J Cardiol ; 206: 108-115, 2023 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-37690148

RESUMO

Subclinical leaflet thrombosis occurs with transcatheter heart valves (THVs) and could be associated with structural valve deterioration. The current guidelines recommend the use of antiplatelet agents after transcatheter aortic valve replacement (TAVR) but not the routine use of oral anticoagulation. Our study examines the effects of short-term warfarin therapy on THV hemodynamics at 24 months after TAVR in low-risk patients. Low-risk patients who underwent TAVR were randomly allocated 1:1 to receive low-dose aspirin (n = 50) or low-dose aspirin plus warfarin (n = 44). After 30 days of treatment, ongoing medication regimens, including anticoagulation, were at the physicians' discretion. Follow-up after a period of 24 months was available for clinical and echocardiographic outcomes. At the 24-month mark, follow-up echocardiography of the randomly allocated patients revealed just 1 additional case of new structural valve deterioration in the aspirin group (compared with the occurrence within 30 days), based on the Valve Academic Research Consortium 3 definitions. There were also no differences in mean pressure gradients (11.5 ± 0.5 mm Hg vs 11.05 ± 4.0 mm Hg, p = 0.6) or peak velocity (2.2 ± 0.5 m/s vs 2.1 ± 0.4 m/s, p = 0.7) between the groups. A composite end point (mortality, stroke, and myocardial infarction) did not show any difference between the groups at long-term follow-up (p = 0.07). In conclusion, in low-risk patients who underwent TAVR, short-term anticoagulation with warfarin did not impact clinical outcomes or THV hemodynamics by echocardiography at 24 months.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Varfarina/uso terapêutico , Aspirina/uso terapêutico , Valva Aórtica/cirurgia , Seguimentos , Anticoagulantes/uso terapêutico , Estenose da Valva Aórtica/etiologia , Próteses Valvulares Cardíacas/efeitos adversos , Resultado do Tratamento
18.
JACC Cardiovasc Interv ; 16(18): 2211-2227, 2023 09 25.
Artigo em Inglês | MEDLINE | ID: mdl-37758379

RESUMO

BACKGROUND: The MITRAL (Mitral Implantation of Transcatheter Valves) trial is the first prospective trial to evaluate the safety and feasibility of balloon-expandable aortic transcatheter heart valves in patients with failed surgical bioprostheses or annuloplasty rings and severe mitral annular calcification treated with mitral valve-in-valve (MViV), valve-in-ring (MViR), or valve-in-mitral annular calcification (ViMAC). OBJECTIVES: The aim of this study was to evaluate 5-year outcomes among these patients. METHODS: A multicenter prospective study was conducted among patients at high surgical risk at 13 U.S. sites. Patients underwent MViV (n = 30), MViR (n = 30), or ViMAC (n = 31) and were followed annually for 5 years. Kansas City Cardiomyopathy Questionnaire scores were obtained at baseline and follow-up visits. Echocardiograms were analyzed at independent core laboratories. RESULTS: A total of 91 patients underwent transcatheter mitral valve replacement (February 2015 to December 2017). The mean age was 74.3 ± 8.9 years. At 5-year follow-up, the lowest all-cause mortality was observed in the MViV group (21.4%), 94.7% of patients were in NYHA functional class I or II, and the mean mitral gradient was 6.6 ± 2.5 mm Hg. The MViR and ViMAC groups had higher all-cause mortality (65.5% and 67.9%), most survivors were in NYHA functional classes I and II (50% and 55.6%), and mean mitral gradients remained stable (5.8 ± 0.1 and 6.7 ± 2.5 mm Hg). Significant improvements in Kansas City Cardiomyopathy Questionnaire scores were observed when all 3 arms were pooled. CONCLUSIONS: MViV, MViR, and ViMAC procedures were associated with sustained improvement of heart failure symptoms and quality of life among survivors at 5 years. Transcatheter heart valve function remained stable in all 3 groups. Patients treated with MViV had excellent survival at 5 years, whereas survival was lower in the MViR and ViMAC groups, consistent with underlying disease severity. Patients with more residual mitral regurgitation had higher mortality.


Assuntos
Calcinose , Cardiomiopatias , Doenças das Valvas Cardíacas , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral , Doenças Vasculares , Humanos , Idoso , Idoso de 80 Anos ou mais , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Estudos Prospectivos , Qualidade de Vida , Resultado do Tratamento , Cateterismo Cardíaco/métodos , Doenças das Valvas Cardíacas/diagnóstico por imagem , Doenças das Valvas Cardíacas/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/etiologia , Calcinose/cirurgia , Doenças Vasculares/etiologia
19.
JACC Case Rep ; 18: 101915, 2023 Jul 19.
Artigo em Inglês | MEDLINE | ID: mdl-37545687

RESUMO

We present a case of post-myocardial infarction free-wall rupture in a critically ill patient presenting to the emergency department. Through our case we highlight the prompt evaluation, diagnosis, and management necessary to improve survival in a patient with this life-threatening condition. (Level of Difficulty: Beginner.).

20.
Int J Cardiol ; 389: 131196, 2023 10 15.
Artigo em Inglês | MEDLINE | ID: mdl-37479148

RESUMO

BACKGROUND: The self-expanding CoreValve Evolut PRO/PRO+ transcatheter aortic valve was designed to overcome the limitations of its forerunner, Evolut R. Evolut PRO/PRO+ offers the lowest delivery profile for 23-29 mm valves, with an external tissue wrap on all valve sizes. We compared safety and efficacy of Evolut PRO/PRO+ and Evolut R. METHODS: We analyzed 300 patients enrolled in the EPROMPT Registry against a historical control cohort of 242 patients who received Evolut R. The two arms were matched (1:1) via propensity-score methodology by accounting for differences in Society of Thoracic Surgeons Predicted Risk of Mortality scores, yielding 440 patients. The endpoints included in-hospital safety clinical outcomes, all-cause mortality, and echocardiographic parameters at 30 days and 1 year. RESULTS: After propensity-score matching, cardiac death (0.5% vs. 0.5%, p = 0.995), stroke (1.6% vs. 2.8%, p = 0.410), life-threatening bleeding (1.1% vs. 3.3%, p = 0.139), major vascular complications (0.5% vs. 0.9%, p = 0.653), and pacemaker implantation (16.9% vs. 13.6%, p = 0.345) were comparable between the Evolut PRO/PRO+ and Evolut R groups. Likewise, the rates of all-cause mortality were similar both at 30 days (0.5% vs. 1.4%, p = 0.315) and 1 year (1.8% vs. 4.1%, p = 0.159). The rates of moderate paravalvular leak (5.7% vs. 2.6%, p = 0.402), and mean gradient (7.27 ± 3.25 mmHg vs. 8.84 ± 4.36 mmHg, p = 0.105) were also comparable between groups at 1 year. CONCLUSION: Our largest-to-date observational study suggests that the Evolut PRO/PRO+ system is safe and effective in treating severe aortic stenosis, with commensurate 30-day and 1-year mortality and similar 1-year echocardiographic hemodynamic outcomes in comparison to Evolut R.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Desenho de Prótese , Resultado do Tratamento , Complicações Pós-Operatórias/etiologia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...