Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
1.
Diagnostics (Basel) ; 14(7)2024 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-38611641

RESUMO

Currently, hepatitis B virus (HBV) core antibody (anti-HBc antibody) and HBV core-related antigen (HBcrAg) are widely used as serum markers for diagnosis based on the HBV core region. This review focused on anti-HBc antibodies and HBcrAg and aimed to summarize the clinical significance of currently used assay systems and the issues involved. While anti-HBc is very significant for clinical diagnosis, the clinical significance of quantitative assay of anti-HBc antibody has been reevaluated with improvements in diagnostic performance, including its association with clinical stage and prediction of carcinogenesis and reactivation. In addition, concerning the new HBcrAg, a high-sensitivity assay method has recently been established, and its diagnostic significance, including the prediction of reactivation, is being reevaluated. On the other hand, the quantitative level of anti-HBc antibody expressed in different units among assay systems complicates the interpretation of the results. However, it is difficult to standardize assay systems as they vary in advantages, and caution is needed in interpreting the assay results. In conclusion, with the development of highly sensitive HBcrAg and anti-HBc antibody, a rapid and sensitive detection assay system has been developed and used in clinical practice. In the future, it is hoped that a global standard will be created based on the many clinical findings.

2.
Sci Rep ; 14(1): 921, 2024 01 09.
Artigo em Inglês | MEDLINE | ID: mdl-38195988

RESUMO

Protein induced by vitamin K absence or antagonist-II (PIVKA-II) is avitamin K (VK) deficiency indicator in neonates. However, PIVKA-II detection frequency in neonatal blood at birth and the correlation between PIVKA-II and gestational age are unclear. We retrospectively analyzed infants admitted to our institution between June 1, 2018, and March 31, 2022, whose clinical and PIVKA-II data were available, and classified them into preterm and term infant groups. Overall incidence of PIVKA-II-positive cases (≥ 50 mAU/mL) was 42.8%, including 0.6% apparent VK deficiency (≥ 5000 mAU/mL), 3.1% experimental VK deficiency (1000-4999 mAU/mL), and 10.7% latent VK deficiency (200-999 mAU/mL) cases. Incidence of PIVKA-II-positive cases was significantly higher in the term group than in the preterm group (49.4% vs. 29.7%, p < 0.001). Gestational age correlated with PIVKA-II levels (r2 = 0.117, p < 0.0001). Median serum PIVKA-II levels and incidence of PIVKA-II-positive cases (≥ 50 mAU/mL, 16.4%) were lower at 5 days after birth than at birth, possibly reflecting the postnatal VK prophylaxis impact. Only one infant was diagnosed with VK deficiency bleeding (PIVKA-II levels, at birth: 10,567 mAU/mL; at day 5: 2418 mAU/mL). Thus, serum PIVKA-II levels after birth weakly correlated with gestational age. VK deficiency was more common in term infants than in preterm infants.


Assuntos
Recém-Nascido Prematuro , Vitamina K , Recém-Nascido , Lactente , Humanos , Estudos Retrospectivos , Idade Gestacional , Instalações de Saúde
3.
Lab Med ; 2023 Sep 14.
Artigo em Inglês | MEDLINE | ID: mdl-37706549

RESUMO

OBJECTIVE: The serum squamous cell carcinoma antigen (SCCA) level is a well-known tumor marker for squamous cell carcinoma. In this study, we examined the impact of immunoglobulin (Ig)-bound macromolecular SCCA on serum SCCA levels measured by 2 different methods. METHODS: Seventy-five serum samples with an SCCA level >5.0 ng/mL as determined by a chemiluminescent immunoassay (CLIA) were also analyzed using a chemiluminescent enzyme immunoassay (CLEIA). The levels of IgG- and IgA-type anti-SCCA antibodies, which form immunoglobulins and macromolecules, respectively, were determined using an enzyme-linked immunosorbent assay. An absorption test was performed to confirm the presence of anti-SCCA antibodies. RESULTS: The correlation coefficient between the values measured by CLEIA and CLIA was 0.768. The ratio of SCCA levels measured by CLEIA to those measured by CLIA in 14 samples with IgG-type anti-SCCA antibodies was significantly lower than that in samples without these antibodies (P < .031). Absorption tests showed that SCCA levels measured by CLIA might be falsely high in samples with IgG-type anti-SCCA antibodies, probably due to reactions with SCCA1. CONCLUSION: The level of SCCA as measured by CLIA and CLEIA methods correlate well, but the presence of SCCA antibodies can affect the results of the CLIA method.

4.
Clin Endocrinol (Oxf) ; 99(2): 217-227, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37278108

RESUMO

OBJECTIVE: Thyroid-stimulating hormone (TSH) harmonization is effective in minimizing differences between the results of immunoassays in healthy subjects. However, the effectiveness of TSH harmonization in clinical practice has not been investigated. The aim of this study was to evaluate the instability of TSH harmonization in clinical practice. METHODS: We compared the reactivities of four harmonized TSH immunoassays using combined difference plots of 431 patients. We selected patients with statistically significant deviations in TSH levels and analyzed their thyroid hormone levels and clinical characteristics. RESULTS: The combined difference plots showed that one harmonized TSH immunoassay exhibited markedly different reactivity even after TSH harmonization compared with the other three immunoassays. Among 109 patients with mild-to-moderate elevation of TSH levels, we selected 15 patients with statistically significant deviations in TSH levels according to the difference plots of three harmonized TSH immunoassays, excluding one immunoassay that showed different reactivity. The thyroid hormone levels of three patients were misclassified as hypothyroidism or normal due to deviating TSH levels. In terms of clinical characteristics, these patients were in poor nutritional status and general condition, possibly due to their severe illness (e.g., advanced metastatic cancer). CONCLUSION: We have confirmed that TSH harmonization in clinical practice is relatively stable. However, some patients showed deviating TSH levels in the harmonized TSH immunoassays, indicating the need for caution, particularly in poorly nourished patients. This finding suggests the presence of factors that contribute to the instability of TSH harmonization in such cases. Further investigation is warranted to validate these results.


Assuntos
Hipotireoidismo , Tireotropina , Humanos , Hormônios Tireóideos , Imunoensaio/métodos , Tiroxina
5.
Pract Lab Med ; 32: e00302, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36217361

RESUMO

Objectives: Rapid plasma reagin (RPR) and Treponema pallidum (TP) antibody test kits are often used to diagnose syphilis, although the relationship between their measured values is unclear. We aimed to reveal the relevance of these kits' results. Design and methods: In all, 143 sera from 110 patients were tested using 12 TP kits and 5 RPR kits and the results compared. Results: The specificity and sensitivity of RPR kits were 81-96% and 95-100%, respectively. The correlation coefficients (0.849-0.934) considerably differed between the manual RPR card test and latex agglutination (LA) assay kits. The following sensitivities were obtained: 82-91% for TP fluorescent treponemal antibody absorption assay (FTA-ABS), TP hemagglutination assay (HA), and TP particle agglutination assay (PA); 94-95% for TP LAs; and 92-100% for chemiluminescent immunoassay (CLIA), chemiluminescent enzyme immunoassay (CLEIA), and immunochromatography assay (IC). Correlation coefficients between TP kits were 0.753-0.974, and the measured values varied. Changes in RPR and quantifiable TP kits were the same for patients with reinfected syphilis and with syphilis under treatment. Conclusions: RPR tests had lower specificity than TP antibody tests. RPR card test and RPR LAs had similar specificity and sensitivity, but their measured values were different. RPR should be measured using automatic RPR LA without setting the upper limit of the reported value. RPR LA should also be standardized. The sensitivity of TP antibody was better in CLIA, CLEIA, and IC than in FTA-ABS, HA, PA, and LA. Therefore, TP antibody kits should be standardized and quantified.

6.
J Clin Med ; 11(17)2022 Aug 31.
Artigo em Inglês | MEDLINE | ID: mdl-36079066

RESUMO

(1) Background: Pseudohypoaldosteronism type 1 (PHA-1) is a disorder caused by renal tubular resistance to aldosterone and is characterized by problems with sodium regulation. PHA-1 is typically divided into primary PHA-1, which is caused by genetic mutation, and secondary PHA-1, which is associated with urinary tract abnormality. However, data on the clinical features of PHA-1 among newborn infants are limited. (2) Methods: We conducted a nationwide prospective surveillance study of neonatal PHA in Japan from 1 April 2019 to 31 March 2022 as part of a rare disease surveillance project of the Japan Society for Neonatal Health and Development. (3) Results: Fifteen cases (male:female = 7:8), including four primary, four secondary, and seven non-classified cases, were reported during the study period. The median gestational age and birthweight were 34 weeks (28-41) and 1852 g (516-4610), respectively. At the onset, the median serum Na and K levels were 132 mEq/L (117-137) and 6.3 mEq/L (4.7-8.3), respectively. The median plasma renin activity was 45 ng/mL/h (3.1-310, n = 9), active renin concentration was 1017 pg/mL (123-2909, n = 6), and serum aldosterone concentration was 5310 pg/mL (3250-43,700). (4) Conclusions: Neonatal PHA-1 was more common among preterm infants with no male predominance. It developed immediately after birth in cases without genetic or renal complications.

7.
PLoS One ; 17(4): e0266270, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35381036

RESUMO

Continuous appearance of SARS-CoV-2 variants and mass vaccination have been intricately influencing on the COVID-19 situation. To elucidate the current status in Japan, we analyzed totally 2,000 sera in August (n = 1,000) and December (n = 1,000) 2021 collected from individuals who underwent a health check-up. The anti-N seropositive rate were 2.1% and 3.9% in August and December 2021, respectively, demonstrating a Delta variant endemic during that time; it was approximately twofold higher than the rate based on the PCR-based diagnosis. The anti-S seropositive rate was 38.7% in August and it reached 90.8% in December, in concordance with the vaccination rate in Japan. In the December cohort, 78.7% of the sera showed neutralizing activity against the Delta variant, whereas that against the Omicron was much lower at 36.6%. These analyses revealed that effective immunity against the Delta variant was established in December 2021, however, prompt three-dose vaccination is needed to overcome Omicron's outbreak.


Assuntos
COVID-19 , SARS-CoV-2 , Anticorpos Neutralizantes , COVID-19/epidemiologia , COVID-19/prevenção & controle , Humanos , Japão/epidemiologia , Vacinação
8.
J Endocr Soc ; 5(6): bvab055, 2021 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-34061117

RESUMO

CONTEXT: Paradoxical increases in serum cortisol in the dexamethasone suppression test (DST) have been rarely observed in Cushing disease (CD). Its pathophysiology and prevalence remain unclear. CASE DESCRIPTION: A 62-year-old woman with suspected CD showed paradoxical increases in cortisol after both 1-mg and 8-mg DST (1.95-fold and 2.52-fold, respectively). The initiation of metyrapone paradoxically decreased plasma adrenocorticotropic hormone (ACTH) levels and suppressed cortisol levels. Moreover, the pituitary tumor considerably shrank during metyrapone treatment. EX VIVO EXPERIMENTS: The resected tumor tissue was enzymatically digested, dispersed, and embedded into Matrigel as 3D cultured cells. ACTH levels in the media were measured. In this tumor culture, ACTH levels increased 1.3-fold after dexamethasone treatment (P < 0.01) while control tumor cultures exhibited no increase in ACTH levels, but rather a 20% to 40% suppression (P < 0.05). CLINICAL STUDY: A cross-sectional, retrospective, multicenter study that included 92 patients with CD who underwent both low-dose and high-dose DST from 2014 to 2020 was performed. Eight cases (8.7%) showed an increase in serum cortisol after both low-dose and high-dose DST. CONCLUSION: This is the first report of a patient with glucocorticoid (GC)-driven positive feedback CD who showed both ACTH suppression and tumor shrinkage by metyrapone. Our cohort study revealed that 8.7% of patients with CD patients possibly possess GC-driven positive-feedback systems, thereby suggesting the presence of a new subtype of CD that is different from the majority of CD cases. The mechanisms exhibiting GC positive feedback in CD and the therapeutic approach for these patients remain to be investigated.

9.
JMA J ; 4(1): 41-49, 2021 Jan 29.
Artigo em Inglês | MEDLINE | ID: mdl-33575502

RESUMO

INTRODUCTION: The coronavirus disease 2019 (COVID-19) pandemic is spreading rapidly all over the world. The Japanese government lifted the state of emergency, announced in April 2020, on May 25, but there are still sporadic clusters. Asymptomatic patients who can transmit severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) cause some of these clusters. It is thus urgent to investigate the seroprevalence of antibodies against SARS-CoV-2 and their neutralizing activity. We conducted a cross-sectional study of >10,000 samples at hospitals in Hyogo Prefecture, Japan. METHODS: Between August 6 and October 1, 2020, we collected samples of residual blood from the patients who visited or were admitted to five hospitals and a foundation in Hyogo. We tested the samples for antibodies against SARS-CoV-2 by electrochemiluminescence immunoassay (ECLIA) and chemiluminescent enzyme immunoassay (CLEIA). Sera that were positive by ECLIA or CLEIA were analyzed by an immunochromatographic (IC) test and neutralizing activity assay. RESULTS: We tested 10,377 samples from patients aged between 0 and 99 years old; 27 cases (0.26%) were positive on the ECLIA, and 51 cases (0.49%) were positive on CLEIA. In the 14 cases that tested positive on both ECLIA and CLEIA, the positive rates on the IC test and for neutralizing activity were high (85% and 92%, respectively). In 50 cases (0.48%) that were positive by either ECLIA or CLEIA, the corresponding rates were low (20% and 6%, respectively). The positive rate of neutralizing antibody was 0.15%. CONCLUSIONS: These results indicate that most Hyogo Prefecture residents still do not have antibodies and should avoid the risk of incurring a SARS-CoV-2 infection. Two or more antibody tests should be required for seroepidemiological studies of the antibody for SARS-CoV-2, and a neutralizing activity assay is also essential.

10.
Clin Lab ; 66(1)2020 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-32013354

RESUMO

BACKGROUND: Considering the physiological changes in serum procalcitonin (PCT) levels in newborns due to age, we recently established an age-specific percentile-based reference curve for serum PCT level. The present study aimed to determine the best cutoff percentile line using this reference curve for the differentiation between infected and colonized preterm infants. METHODS: A total of 52 preterm infants with positive bacterial culture (9 with bacterial infection, 43 with colonization) were enrolled within the study period. The 97.5th, 95.0th, 92.5th, 90.0th, 80.0th, 70.0th, 60.0th, and 50.0th percentile lines were drawn in the reference curve. PCT levels in infected or colonized infants were used, and sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were calculated. The best cutoff percentile line was determined in the receiver operating characteristic curve analysis. RESULTS: Of the 52 preterm infants, 9 were infected (5 and 4 infants with an onset of < 7 days and ≥ 7 days after birth, respectively), whereas 43 were colonized (6 and 37 infants with an onset of < 7 days and ≥ 7 days after birth, respectively). The best cutoff percentile lines were the 90.0th percentile (sensitivity, 0.800; specificity, 0.833; PPV, 0.800; NPV, 0.833) and 97.5th percentile (sensitivity, 1.00; specificity, 0.973; PPV, 0.800; NPV, 1.00) in infants with an onset of < 7 days and ≥ 7 days after birth, respectively. CONCLUSIONS: The age-specific percentile-based reference curve for serum PCT level is clinically applicable as a new tool for diagnosing infections in preterm infants with positive culture results, particularly at ≥ 7 days after birth.


Assuntos
Infecções Bacterianas/diagnóstico , Recém-Nascido Prematuro , Pró-Calcitonina/sangue , Fatores Etários , Infecções Bacterianas/epidemiologia , Biomarcadores/sangue , Portador Sadio/diagnóstico , Portador Sadio/epidemiologia , Feminino , Humanos , Lactente , Recém-Nascido , Unidades de Terapia Intensiva Neonatal , Masculino , Sepse Neonatal/diagnóstico , Sepse Neonatal/epidemiologia , Valor Preditivo dos Testes , Valores de Referência , Estudos Retrospectivos
11.
Circ Genom Precis Med ; 11(1): e001782, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-29874176

RESUMO

BACKGROUND: Duchenne muscular dystrophy (DMD), the most common inherited muscular disease in childhood, is caused by dystrophin deficiency because of mutations in the DMD gene. Although DMD is characterized by fatal progressive muscle wasting, cardiomyopathy is the most important nonmuscle symptom threatening the life of patients with DMD. The relationship between cardiac involvement and dystrophin isoforms has not been analyzed. METHODS AND RESULTS: The results of 1109 echocardiograms obtained from 181 Japanese DMD patients with confirmed mutations in the DMD gene were retrospectively analyzed. Patients showed an age-related decline in left ventricular ejection fraction. Patients were divided by patterns of dystrophin isoform deficiency into 5 groups. The cardiac dysfunction-free survival was significantly higher in the group with mutations in the Dp116 coding region than the others, whereas no significant differences in the other 3 groups. At age 25 years, the cardiac dysfunction-free rate was 0.6 in the Dp116 group, but only 0.1 in others. PCR amplification of Dp116 transcript in human cardiac muscle indicated promoter activation. CONCLUSIONS: Left ventricular ejection fraction in DMD declined stepwise with age. Cardiac dysfunction was less frequent in Dp116-deficient than other patients with DMD. Dp116 transcript was identified in human cardiac muscle for the first time. These results indicate that Dp116 is associated with cardiac involvement in DMD.


Assuntos
Distrofina/genética , Distrofia Muscular de Duchenne/genética , Função Ventricular Esquerda/fisiologia , Adolescente , Adulto , Criança , Pré-Escolar , Intervalo Livre de Doença , Distrofina/metabolismo , Humanos , Estimativa de Kaplan-Meier , Distrofia Muscular de Duchenne/mortalidade , Distrofia Muscular de Duchenne/patologia , Fases de Leitura Aberta/genética , Polimorfismo Genético , Regiões Promotoras Genéticas , Isoformas de Proteínas/genética , Isoformas de Proteínas/metabolismo , Estudos Retrospectivos , Adulto Jovem
12.
Ann Clin Biochem ; 55(3): 400-403, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-28656818

RESUMO

Background Our aim was to determine whether the postnatal age or postmenstrual age is a more appropriate criterion for evaluating foetal haemoglobin concentrations. Methods Blood samples ( n = 1095) were obtained from 394 infants and were divided into two groups based on gestational age at birth: <37 weeks ( n = 491) and ≥37 weeks ( n = 604). (1) Foetal haemoglobin concentrations divided by one month at age after birth were compared between the groups. (2) Foetal haemoglobin concentrations divided into ≤9 months from last menstruation and one month thereafter were compared between the groups. Results In samples from infants ≥37 weeks' gestational age at birth, the median foetal haemoglobin concentrations were 69.5%, 21.4% and 3.6% at 0-1 month, 2-3 months and ≥5 months after birth, respectively. The median foetal haemoglobin concentrations in infants <37 weeks' gestational age at birth were 75.5%, 62.7% and 5.1% at 0-1 month, 2-3 months and ≥5 months after birth, respectively. The median foetal haemoglobin concentrations in infants <37 weeks' gestational age at birth were significantly higher than that in infants ≥37 weeks' gestational age at birth at all postnatal age points. (2) There was no significant difference between the groups at all age points after nine months of postmenstrual age: 72.5 and 75.3% at 9-10 months, 25.1 and 26.6% at 11-12 months and 5.5 and 4.6% at >13 months after last menstruation in infants ≥37 and <37 weeks' gestational age at birth, respectively. Conclusions Evaluation of foetal haemoglobin concentrations at postmenstrual age is unaffected by gestational age at birth.


Assuntos
Hemoglobina Fetal/análise , Idade Gestacional , Menarca , Adolescente , Pré-Escolar , Cromatografia Líquida de Alta Pressão , Feminino , Humanos , Lactente , Recém-Nascido , Recém-Nascido Prematuro , Masculino
13.
Rinsho Byori ; 65(2): 131-137, 2017 02.
Artigo em Japonês | MEDLINE | ID: mdl-30762978

RESUMO

The fully automated HELIOS® system for antinuclear antibody (ANA) test is capable of automatically per- forming all IFA procedures. We evaluated the analytical performance, characteristics and utility of HELIOS system as ANA screening test. We compared HELIOS system and the conventional methods in sera from 161 connective tissue disease (CTD) patients and 250 healthy individuals. The presence and titer of ANA were automatically determined by performing HELIOS system at 1:80 dilution and the ANA titers were com- pensated by several dilution and visual determination in sera with a high ANA titer and ANA-positive sera combined with anti-cytoplasmic antibody. The ANA staining patterns were assessed by visual determination of the digital image on HELIOS system. The total concordance rate between the conventional method and HELIOS system was 94.4%. The concordance of ANA titer (within ± 1 tube difference) between the con- ventional method and automated or compensated evaluation of HELIOS system was 85.7% or 98.8%, respec- tively. The concordance rate of six nuclear staining patterns was from 81.4% to 100% and the discrepancies of granular staining pattern might be caused by the fixation of HEp-2 cells. The positive rates of ANA in CTD patients and healthy individuals were comparable with the conventional methods. Taken together, HELIOS system can appropriately perform the automated determination of ANA except in some cases and is useful as ANA screening test. Furthermore, this system can contribute not only an efficient IFA procedure but also the ANA standardization by IFA. [Original].


Assuntos
Anticorpos Antinucleares , Automação Laboratorial , Doenças do Tecido Conjuntivo , Técnica Indireta de Fluorescência para Anticorpo , Doenças Autoimunes , Doenças do Tecido Conjuntivo/diagnóstico , Técnica Indireta de Fluorescência para Anticorpo/métodos , Humanos
14.
Rinsho Byori ; 65(3): 245-251, 2017 03.
Artigo em Japonês | MEDLINE | ID: mdl-30802006

RESUMO

A high sensitivity quantitative assay for hepatitis B virus (HBV) surface antigen (HBsAg-HQ assay) was recently developed and is useful for earlier detection of HBV reactivation. We created HBsAg-HQ assay operational proce- dures by the sample transport system and laboratory information system. In this study, we evaluated the perfor- mance and utility of the HBsAg-HQ assay based on our operational procedures using internal quality control (IQC) data and 13,762 samples routinely measured for 8 months. The IQC data of the HBsAg-HQ assay demonstrated good accuracy (CV: 1.6-2.7%). The difference in IQC data between two of the same analyzers or several reagent lots had no clinical significance. Of 13,762 samples, HBsAg titer was negative in 12,592(91.5%) and positive in 1,169(8.5%), and HBsAg negative samples were remarkably lower(<0.001 IU/mL) than the cut-off value(0.005 IU/mL). Among 114 HBsAg weakly positive samples ranging from 0.005 to 1.000 IU/mL, false positive results occurred in 12 samples, which were converted into negative results after re-measurement. We could effectively perform carry-over prevention and dilution of high titer samples using our operational procedures. Furthermore, we performed inhibition test in 52 HBsAg weakly positive samples, and 20 samples, most of which were taken from patients with connective tissue disease or malignancy, were judged as non-specific reactivity. Taken together, our operational HBsAg-HQ assay procedures may contribute to efficient workflow for routine testing. Moreover, the HBsAg-HQ assay may be clinically useful for not only highly sensitive assays, but also for reducing false positives.


Assuntos
Antígenos de Superfície da Hepatite B , Hepatite B , Técnicas Imunoenzimáticas , Hepatite B/diagnóstico , Antígenos de Superfície da Hepatite B/imunologia , Vírus da Hepatite B/imunologia , Humanos , Sensibilidade e Especificidade , Testes Sorológicos
15.
Rinsho Byori ; 64(2): 142-51, 2016 Feb.
Artigo em Japonês | MEDLINE | ID: mdl-27311277

RESUMO

Antinuclear antibody (ANA) testing is indispensable for diagnosing and understanding clinical conditions of autoimmune diseases. The indirect immunofluorescence assay (IFA) is the gold standard for ANA screening, and it can detect more than 100 different antibodies, such as anti-PCNA as well as anti-cytoplasmic antibodies. However, complicated procedures of conventional IFA and visual interpretation require highly skilled laboratory staff. This study evaluates the capability, characteristics, and applicability of the recently developed ANA detection system (EUROPattern Cosmic IFA System, EPA) using HEp20-10 cells and the automated pattern recognition microscope. Findings using EPA and conventional methods were compared in 282 sera obtained from connective tissue disease patients and 250 sera from healthy individuals. The concordance of the positivity rate, antibody titer (within +/- 1 tube difference), and the accurate recognition rate of ANA patterns between the automated EPA method and the microscopic judgement of the EPA image by eye was 98.9, 97.4, and 55.3%, respectively. The EPA method showed concordance of the positivity rate as high as 93.3% and concordance of the antibody titer as high as 94.0% (within +/- 1 titer) compared with the conventional method. Regarding the four typical patterns of ANA (homogeneous, speckled, nucleolar, and centromere), large differences between the EPA and conventional methods were not observed, and the rate of concordance between the final EPA result and the conventional method was from 94.1 to 100%. The positivity rate of ANA using the EPA and conventional methods showed marked agreement among the six connective tissue diseases (SLE, MCTD, SSc, PM/DM, and SS) and healthy individuals. Although the EPA system is not considered a complete system and laboratory staff should verify the results, it is a useful system for routine ANA analysis because it contributes to ANA standardization and an efficient workflow.


Assuntos
Anticorpos Antinucleares/sangue , Doenças Autoimunes/diagnóstico , Técnica Indireta de Fluorescência para Anticorpo/métodos , Processamento de Imagem Assistida por Computador/métodos , Microscopia/métodos , Kit de Reagentes para Diagnóstico , Biomarcadores/sangue , Feminino , Humanos , Masculino , Antígeno Nuclear de Célula em Proliferação/imunologia , Reprodutibilidade dos Testes
16.
Sci Rep ; 6: 23871, 2016 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-27033746

RESUMO

Procalcitonin (PCT) levels are elevated early after birth in newborn infants; however, the physiological features and reference of serum PCT concentrations have not been fully studied in preterm infants. The aims of the current study were to establish an age-specific percentile-based reference curve of serum PCT concentrations in preterm infants and determine the features. The PCT concentration peaked in infants at 1 day old and decreased thereafter. At 1 day old, serum PCT concentrations in preterm infants <34 weeks' gestational age were higher than those in late preterm infants between 34 and 36 weeks' gestational age or term infants ≥37 weeks' gestational age. Although the 50-percentile value in late preterm and term infants reached the adult normal level (0.1 ng/mL) at 5 days old, it did not in preterm infants. It took 9 weeks for preterm infants to reach it. Serum PCT concentrations at onset in late-onset infected preterm infants were over the 95-percentile value. We showed that the physiological feature in preterm infants was significantly different from that in late preterm infants, even in those <37 weeks' gestational age. To detect late-onset bacterial infection and sepsis, an age-specific percentile-based reference curve may be useful in preterm infants.


Assuntos
Infecções Bacterianas/sangue , Calcitonina/sangue , Doenças do Prematuro/sangue , Recém-Nascido Prematuro/sangue , Povo Asiático , Biomarcadores , Enterobacter cloacae , Infecções por Enterobacteriaceae/sangue , Infecções por Enterobacteriaceae/microbiologia , Feminino , Seguimentos , Idade Gestacional , Humanos , Recém-Nascido , Masculino , Pneumonia Associada à Ventilação Mecânica/sangue , Pneumonia Associada à Ventilação Mecânica/microbiologia , Infecções por Pseudomonas/sangue , Valores de Referência , Sepse/sangue
17.
Rinsho Byori ; 63(4): 427-34, 2015 Apr.
Artigo em Japonês | MEDLINE | ID: mdl-26536775

RESUMO

PURPOSE: Measurement of matrix metalloproteinase-3(MMP-3), a marker for rheumatoid arthritis, by means of latex agglutination turbidimetric immunoassay (LTIA), has come to replace ELISA kit, but pre-improvement LTIA kit S(Sekisui Medical) frequently shows false values resulting from non-specific reactions. We analyzed factors influencing the frequency of non-specific reactions for MMP-3 detection using various methods. METHOD: Serum MMP-3 levels were measured in 1,214 routine samples or 57 panels with various immunoserological abnormalities by means of pre-improvement and improved kit S, LTIA kit E (Eiken Chemical) and ELISA kit. Non-specific reaction samples were selected either from the routine samples based on the results of correlativity tests between the kits and of dilution linearity tests, or from 57 panels with immunoserological abnormalities based on the results of recovery tests. To explore the factors causing non- specific reactions, titers of rheumatoid factor (RF), immunoglobulins and four heterophil antibodies were measured in these samples. In addition, changes in findings as a result of reduction treatment or IgM absorption were examined in selected samples to clarify the effect of heterophil antibodies. RESULTS: Samples which showed suspected false values probably due to non-specific reaction numbered 75, 15, 5 and 17 as measured with pre-improvement kit S, improved kit S, kit E and ELISA kit, respectively. Kit S also showed high rate of deviation in recovery tests on panels with immunoserological abnormalities. Rate of RF titer in samples with non-specific reactions was higher than that of other factors. Non-specific reaction could be inhibited in two samples as a result of reduction treatment or absorption of IgM subtype. CONCLUSION: Pre-improvement kit S showed a higher rate of non-specific reactions than other kits. The most common cause of non-specific reactions is thought to be high RF titer, but high levels of IgM, including heterophil antibodies, may also affect the values of MMP-3.


Assuntos
Imunoensaio/métodos , Testes de Fixação do Látex/métodos , Metaloproteinase 3 da Matriz/sangue , Nefelometria e Turbidimetria/métodos , Kit de Reagentes para Diagnóstico , Anticorpos Heterófilos , Artrite Reumatoide/diagnóstico , Biomarcadores/sangue , Ensaio de Imunoadsorção Enzimática , Humanos , Imunoglobulina M , Fator Reumatoide
18.
Brain Dev ; 37(8): 753-7, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25638486

RESUMO

BACKGROUND: This study aimed to evaluate peak serum total bilirubin (TB) and unbound bilirubin (UB) levels in preterm infants with clinical kernicterus (KI) who were diagnosed by clinical findings during infancy. DESIGN/SUBJECTS: For this multicenter retrospective study, 18 Japanese extremely low birth weight (ELBW) infants with clinical KI were included. Clinical KI was diagnosed based on the presence of motor developmental impairment with/without athetosis, and abnormal magnetic resonance imaging or brainstem auditory evoked potential findings during infancy. High and low TB or UB levels were defined as serum TB levels ⩾ and <15 mg/dL or serum UB levels ⩾ and <0.8 µg/dL, respectively. The clinical characteristics of KI preterm infants were analyzed. The proportion of infants with high or low serum TB levels and with high or low serum UB levels was then investigated. Sensitivity and specificity were calculated. RESULTS: In 18 KI infants, the median age when serum TB levels peaked was 28 days after birth. In eight KI infants with low serum TB levels, 88% of them had high serum UB levels. For comparison of the number of infants who had high or low serum TB and UB levels, the sensitivity was 90% and specificity was 13%. CONCLUSIONS: Serum TB and UB levels peak at a later age than expected. Chronic serum UB monitoring may be helpful for identifying ELBW infants at risk for developing KI, even when they do not have high serum TB levels.


Assuntos
Bilirrubina/sangue , Kernicterus/sangue , Feminino , Humanos , Lactente , Recém-Nascido de Baixo Peso , Recém-Nascido , Recém-Nascido Prematuro , Unidades de Terapia Intensiva Neonatal , Kernicterus/diagnóstico , Masculino , Estudos Retrospectivos
19.
Ann Clin Biochem ; 51(Pt 6): 680-7, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24604629

RESUMO

BACKGROUND: Few studies have reported the characterization of postnatal serum concentrations of endogenous free fatty acids (FFAs) in high-risk newborns and their effects on unbound bilirubin (UB). METHODS: Serum concentrations of FFA, albumin (Alb), UB and total bilirubin (TB) were measured in 713 samples obtained within 5 days after birth from 439 newborns without intravenous lipid supplementation admitted to the neonatal intensive care unit (NICU). Serum FFA was reported as the day-specific percentile-based curve. Serum FFA and FFA/Alb ratios were compared in term and preterm patients. To assess the impact of FFA on UB, daily changes in FFA/Alb and UB/TB ratios were compared in term patients without receiving phototherapy or any drugs, and linear regression analysis was performed between FFA/Alb ratio and serum UB concentration or UB/TB ratio using 140 sera with hyperbilirubinemia of term and preterm patients. RESULTS: A percentile-based curve showed that serum FFA peaked at 1 day of age and progressively decreased. Serum FFA and the FFA/Alb ratio were significantly higher in term than in preterm patients at birth and 1 and 3 days of age. FFA/Alb ratio significantly changed over 5 days after birth, but UB/TB ratio remained constant. FFA/Alb ratio did not correlate with serum UB concentration or UB/TB ratio in sera with hyperbilirubinemia. CONCLUSIONS: We assessed postnatal concentrations of serum FFA in a large number of high-risk newborns admitted to the NICU. The concentration of endogenous FFAs in newborns admitted to the NICU was not rising until it influenced UB.


Assuntos
Bilirrubina/sangue , Ácidos Graxos não Esterificados/sangue , Feminino , Humanos , Hiperbilirrubinemia/sangue , Recém-Nascido de Baixo Peso , Recém-Nascido , Recém-Nascido Prematuro , Recém-Nascido de muito Baixo Peso , Unidades de Terapia Intensiva Neonatal , Masculino , Fatores de Risco , Albumina Sérica/análise
20.
Pediatr Int ; 55(1): 54-9, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22978498

RESUMO

BACKGROUND: Serum unbound bilirubin (UB) is a measure of bilirubin not bound to albumin, and has been reported to be better than total bilirubin level at identifying infants at risk of developing bilirubin-induced neurotoxicity, including auditory abnormalities. A detailed treatment strategy for newborns with high serum UB has not been established. The aim of this study was to assess auditory outcomes in newborns with serum UB ≥1.00 µg/dL who were treated according to a novel treatment protocol. METHODS: A prospective clinical study was conducted in newborns weighing >1500 g with serum UB ≥1.00 µg/dL who were admitted to Kobe University Hospital and Kakogawa Municipal Hospital, Japan from 2006 to 2011. Enrolled newborns were treated as follows: (i) if serum UB was 1.00-1.50 µg/dL, phototherapy and infusion were given with or without albumin or immunoglobulin therapy; and (ii) if serum UB was >1.50 µg/dL, exchange transfusion was performed immediately. Auditory brainstem responses were evaluated at the time of discharge. RESULTS: A total of 89 Japanese newborns with UB ≥1.00 µg/dL were enrolled at a median age of 4 days. Of these, 85 had UB 1.00-1.50 µg/dL and four had UB >1.50 µg/dL. After being treated according to the protocol, no newborns were diagnosed with auditory brainstem response abnormalities. CONCLUSIONS: The present treatment protocol for Japanese newborns with serum UB ≥1.00 µg/dL may be useful for the prevention of bilirubin-induced auditory abnormalities.


Assuntos
Albuminas/uso terapêutico , Transfusão Total , Perda Auditiva Neurossensorial/prevenção & controle , Hiperbilirrubinemia Neonatal/terapia , Imunoglobulinas Intravenosas/uso terapêutico , Fatores Imunológicos/uso terapêutico , Fototerapia , Protocolos Clínicos , Terapia Combinada , Feminino , Perda Auditiva Neurossensorial/etiologia , Humanos , Hiperbilirrubinemia Neonatal/complicações , Hiperbilirrubinemia Neonatal/diagnóstico , Recém-Nascido , Infusões Intravenosas , Japão , Masculino , Estudos Prospectivos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...