Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Am J Case Rep ; 22: e931058, 2021 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-34078850

RESUMO

BACKGROUND Strangulation of the coronary guidewire is an infrequent complication of percutaneous coronary intervention (PCI), and it can lead to disastrous outcomes of stent thrombosis, vessel occlusion, and vessel damage. CASE REPORT Early-generation stents were made from stainless steel and had a bulky design as compared to cobalt-chromium or platinum chromium alloys, which have superior trackability at the cost of a thin core and low-strength struts, resulting in increased incidence of longitudinal stent deformation. We present a case of a 62-year-old active smoker with effort angina of Canadian Cardiovascular Society (CCS) class III. His coronary angiogram revealed a totally occluded right coronary artery (RCA). After placing 2 coronary guidewires (Run-through and Balanced middle-weight), Xience Xpedition (3.25×48 mm) and Promus Element (2.75×32 mm) were deployed through the whole length of the RCA. While placing the distal stent, the guidewire securing the posterior left ventricular (PLV) was trapped between 2 stents and all attempted maneuvers were unsuccessful in retrieving the wire. The stents sustained longitudinal deformation by the guide catheter, and subsequent arteriotomy for stent and wire retrieval and coronary artery bypass graft surgery were (CABG) performed. CONCLUSIONS Despite the remarkable safety profiles of the percutaneous equipment, complications still occur even with experienced operators. Calcified and tortuous vessels are primarily at risk for wire strangulation between stents or side-branches, and better deliverability of newer drug-eluting stents (DES) comes at the cost of reduced longitudinal strength.


Assuntos
Doença da Artéria Coronariana , Intervenção Coronária Percutânea , Canadá , Angiografia Coronária , Doença da Artéria Coronariana/cirurgia , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/cirurgia , Humanos , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Desenho de Prótese , Stents/efeitos adversos , Resultado do Tratamento
2.
PLoS One ; 15(1): e0225077, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31951610

RESUMO

BACKGROUND: The data on infective endocarditis after transcatheter aortic valve implantation (TAVI) is scarce and limited to case reports and case series in the literature. It is the need of the hour to analyze the available data on post-TAVI infective endocarditis from the available literature. The objectives of this systematic review were to evaluate the incidence of infective endocarditis after transcatheter aortic valve implantation, its microbiological profile and clinical outcomes. It will help us to improve the antibiotic prophylaxis strategies and treatment options for infective endocarditis in the context of TAVI. METHODS: EMBASE, Medline and the CENTRAL trials registry of the Cochrane Collaboration were searched for articles on infective endocarditis in post-TAVI patients till October 2018. Eleven articles were included in the systematic review. The outcomes assessed werethe incidence of infective endocarditis, its microbiological profile andclinical outcomes including major adverse cardiac event (MACE), net adverse clinical event (NACE), surgical intervention and valve-in-valve procedure. RESULTS: The incidence of infective endocarditis varied from 0%-14.3% in the included studies, the mean was3.25%. The average duration of follow-up was 474 days (1.3 years). Enterococci were the most common causative organism isolated from 25.9% of cases followed by Staphylococcus aureus (16.1%) and coagulase-negative Staphylococcus species (14.7%). The mean in-hospital mortality and mortality at follow-up was 29.5% and 29.9%, respectively. The cumulative incidence of heart failure, stroke and major bleeding were 37.1%, 5.3% and 11.3%,respectively. Only a single study by Martinez-Selles et al. reported arrhythmias in 20% cases. The septic shock occurred in 10% and 27.7% post-TAVI infective endocarditis patients according to 2 studies. The surgical intervention and valve-in-valve procedure were reported in 11.4% and 6.4% cases, respectively. CONCLUSION: The incidence of post-TAVI infective endocarditis is low being 3.25% but it is associated with high mortality and complications. The most common complication is heart failure with a cumulative incidence of 37.1%. Enterococciare the most common causative organism isolated from 25.9% of cases followed by Staphylococcus aureus in 16.1% of cases. Appropriate measures should be taken to prevent infective endocarditis in post-TAVI patients including adequate antibiotics prophylaxis directed specifically against these organisms. STUDY REGISTRATION: PROSPERO registration number CRD42018115943.


Assuntos
Endocardite Bacteriana/microbiologia , Endocardite/microbiologia , Infecções Relacionadas à Prótese/microbiologia , Infecções Estafilocócicas/microbiologia , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Antibioticoprofilaxia/métodos , Endocardite/tratamento farmacológico , Endocardite/epidemiologia , Endocardite/patologia , Endocardite Bacteriana/tratamento farmacológico , Endocardite Bacteriana/epidemiologia , Endocardite Bacteriana/patologia , Enterococcus/efeitos dos fármacos , Enterococcus/patogenicidade , Feminino , Próteses Valvulares Cardíacas/microbiologia , Mortalidade Hospitalar , Humanos , Masculino , Pessoa de Meia-Idade , Infecções Relacionadas à Prótese/tratamento farmacológico , Infecções Relacionadas à Prótese/epidemiologia , Infecções Relacionadas à Prótese/patologia , Fatores de Risco , Caracteres Sexuais , Infecções Estafilocócicas/tratamento farmacológico , Infecções Estafilocócicas/epidemiologia , Infecções Estafilocócicas/patologia , Staphylococcus aureus/patogenicidade , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...