Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
1.
Anal Bioanal Chem ; 400(4): 1105-12, 2011 May.
Artigo em Inglês | MEDLINE | ID: mdl-21455654

RESUMO

γ-Hydroxybutyric acid (GHB) is an endogenous short-chain fatty acid popular as a recreational drug due to sedative and euphoric effects, but also often implicated in drug-facilitated sexual assaults owing to disinhibition and amnesic properties. Whilst discrimination between endogenous and exogenous GHB as required in intoxication cases may be achieved by the determination of the carbon isotope content, such information has not yet been exploited to answer source inference questions of forensic investigation and intelligence interests. However, potential isotopic fractionation effects occurring through the whole metabolism of GHB may be a major concern in this regard. Thus, urine specimens from six healthy male volunteers who ingested prescription GHB sodium salt, marketed as Xyrem(®), were analysed by means of gas chromatography/combustion/isotope ratio mass spectrometry to assess this particular topic. A very narrow range of δ(13)C values, spreading from -24.81‰ to -25.06‰, was observed, whilst mean δ(13)C value of Xyrem(®) corresponded to -24.99‰. Since urine samples and prescription drug could not be distinguished by means of statistical analysis, carbon isotopic effects and subsequent influence on δ(13)C values through GHB metabolism as a whole could be ruled out. Thus, a link between GHB as a raw matrix and found in a biological fluid may be established, bringing relevant information regarding source inference evaluation. Therefore, this study supports a diversified scope of exploitation for stable isotopes characterized in biological matrices from investigations on intoxication cases to drug intelligence programmes.


Assuntos
Isótopos de Carbono/análise , Medicina Legal/métodos , Hidroxibutiratos/urina , Adulto , Cromatografia Gasosa-Espectrometria de Massas , Humanos , Hidroxibutiratos/administração & dosagem , Hidroxibutiratos/farmacocinética , Drogas Ilícitas , Masculino , Detecção do Abuso de Substâncias/métodos
2.
Endocrinol Metab Clin North Am ; 39(1): 59-73, viii-ix, 2010 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-20122450

RESUMO

The Athlete Biological Passport (ABP) is an individual electronic document that collects data regarding a specific athlete that is useful in differentiating between natural physiologic variations of selected biomarkers and deviations caused by artificial manipulations. A subsidiary of the endocrine module of the ABP, that which here is called Athlete Steroidal Passport (ASP), collects data on markers of an altered metabolism of endogenous steroidal hormones measured in urine samples. The ASP aims to identify not only doping with anabolic-androgenic steroids, but also most indirect steroid doping strategies such as doping with estrogen receptor antagonists and aromatase inhibitors. Development of specific markers of steroid doping, use of the athlete's previous measurements to define individual limits, with the athlete becoming his or her own reference, the inclusion of heterogeneous factors such as the UDPglucuronosyltransferase B17 genotype of the athlete, the knowledge of potentially confounding effects such as heavy alcohol consumption, the development of an external quality control system to control analytical uncertainty, and finally the use of Bayesian inferential methods to evaluate the value of indirect evidence have made the ASP a valuable alternative to deter steroid doping in elite sports. The ASP can be used to target athletes for gas chromatography/combustion/ isotope ratio mass spectrometry (GC/C/IRMS) testing, to withdraw temporarily the athlete from competing when an abnormality has been detected, and ultimately to lead to an antidoping infraction if that abnormality cannot be explained by a medical condition. Although the ASP has been developed primarily to ensure fairness in elite sports, its application in endocrinology for clinical purposes is straightforward in an evidence-based medicine paradigm.


Assuntos
Anabolizantes/análise , Androgênios/análise , Atletas , Dopagem Esportivo/prevenção & controle , Fatores Etários , Anabolizantes/administração & dosagem , Androgênios/administração & dosagem , Androstano-3,17-diol/análise , Teorema de Bayes , Biomarcadores/análise , Desidroepiandrosterona/análise , Epitestosterona/análise , Etiocolanolona/análise , Feminino , Variação Genética , Humanos , Masculino , Resistência Física/efeitos dos fármacos , Resistência Física/fisiologia , Valores de Referência , Fatores Sexuais , Testosterona/análise , Testosterona/fisiologia
3.
Forensic Sci Int ; 198(1-3): 46-52, 2010 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-20056363

RESUMO

Popularity of gamma-hydroxybutyric acid (GHB) is fairly stable among drug users, while the consumption of its chemical precursor, gamma-butyrolactone (GBL), is a growing phenomenon. Although conventional analytical methods allow to detect this substance in various matrices, linking a trace and a source is still a difficult challenge. However, as several synthesis pathways and chemical precursors exist for the production of GBL, its carbon isotopic signature may vary extensively. For that purpose, a method has been developed to determine the carbon isotopes content of GBL by means of gas chromatography/combustion/isotope ratio mass spectrometry (GC/C/IRMS). The delta(13)C-values of 19 bulk samples purchased worldwide were in the range from -23.1 to -45.8 per thousand (SD<0.3 per thousand). Furthermore, testing on the purification of GBL by distillation has not been found to be consistent with such a large range of delta(13)C-values, which are likely to result from the isotopic composition of the organic precursors used to produce GBL together with the kinetic isotope effect associated with the synthesis routes. Finally, inter- and intra-variability measurements of the delta(13)C-values demonstrated the high potential of IRMS for discriminating between seizures of GBL and for source determination.

4.
J Chromatogr B Analyt Technol Biomed Life Sci ; 877(29): 3767-70, 2009 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-19800302

RESUMO

Stimulants are banned in-competition for all categories of sports by the World Anti-Doping Agency. A simple liquid chromatography-tandem mass spectrometry (LC-MS/MS) assay employing electrospray ionisation in positive mode was developed in that work for the quantification in urine specimens of 4-methyl-2-hexaneamine, a primary amine exhibiting sympathomimetic properties. Following a simple pretreatment procedure, the analyte was separated using a gradient mobile phase on reverse phase C8 column. Selected reaction monitoring m/z 116.2-->57.3 was specific for detection of 4-methyl-2-hexaneamine and the assay exhibited a linear dynamic range of 50-700 ng/mL. The validated method has been successfully applied to analyze the target compound in food supplements as well as in urine specimens. The administered drug (40 mg) was detected at the level of 350 ng/mL in the urine up to 4 days.


Assuntos
Aminas/urina , Aminas/química , Aminas/farmacocinética , Cromatografia Líquida/métodos , Dopagem Esportivo , Cromatografia Gasosa-Espectrometria de Massas/métodos , Humanos , Reprodutibilidade dos Testes , Espectrometria de Massas em Tandem/métodos
5.
J Chromatogr B Analyt Technol Biomed Life Sci ; 877(23): 2321-9, 2009 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-19117813

RESUMO

Carbon isotope ratio of androgens in urine specimens is routinely determined to exclude an abuse of testosterone or testosterone prohormones by athletes. Increasing application of gas chromatography/combustion/isotope ratio mass spectrometry (GC/C/IRMS) in the last years for target and systematic investigations on samples has resulted in the demand for rapid sample throughput as well as high selectivity in the extraction process particularly in the case of conspicuous samples. For that purpose, we present herein the complimentary use of an SPE-based assay and an HPLC fractionation method as a two-stage strategy for the isolation of testosterone metabolites and endogenous reference compounds prior to GC/C/IRMS analyses. Assays validation demonstrated acceptable performance in terms of intermediate precision (range: 0.1-0.4 per thousand) and Bland-Altman analyses revealed no significant bias (0.2 per thousand). For further validation of this two-stage analyses strategy, all the specimens (n=124) collected during a major sport event were processed.


Assuntos
Androgênios/urina , Isótopos de Carbono/análise , Detecção do Abuso de Substâncias/métodos , Testosterona/urina , Cromatografia Gasosa/métodos , Cromatografia Líquida de Alta Pressão/métodos , Dopagem Esportivo , Espectrometria de Massas/métodos
6.
Steroids ; 74(3): 359-64, 2009 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-19056413

RESUMO

19-Norandrosterone (19-NA) as its glucuronide derivative is the target metabolite in anti-doping testing to reveal an abuse of nandrolone or nandrolone prohormone. To provide further evidence of a doping with these steroids, the sulfoconjugate form of 19-norandrosterone in human urine might be monitored as well. In the present study, the profiling of sulfate and glucuronide derivatives of 19-norandrosterone together with 19-noretiocholanolone (19-NE) were assessed in the spot urines of 8 male subjects, collected after administration of 19-nor-4-androstenedione (100mg). An LC/MS/MS assay was employed for the direct quantification of sulfoconjugates, whereas a standard GC/MS method was applied for the assessment of glucuroconjugates in urine specimens. Although the 19-NA glucuronide derivative was always the most prominent at the excretion peak, inter-individual variability of the excretion patterns was observed for both conjugate forms of 19-NA and 19-NE. The ratio between the glucuro- and sulfoconjugate derivatives of 19-NA and 19-NE could not discriminate the endogenous versus the exogenous origin of the parent compound. However, after ingestion of 100mg 19-nor-4-androstenedione, it was observed in the urine specimens that the sulfate conjugates of 19-NA was detectable over a longer period of time with respect to the other metabolites. These findings indicate that more interest shall be given to this type of conjugation to deter a potential doping with norsteroids.


Assuntos
Corticosterona/análogos & derivados , Dopagem Esportivo , Estranos/urina , Detecção do Abuso de Substâncias/métodos , Adulto , Cromatografia Líquida , Corticosterona/urina , Cromatografia Gasosa-Espectrometria de Massas , Humanos , Masculino , Espectrometria de Massas em Tandem , Adulto Jovem
9.
J Chromatogr A ; 1196-1197: 153-60, 2008 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-18501914

RESUMO

Together with steroid glucuronides, sulfoconjugates may be used as markers of steroid administration as well as endogenous steroid production. A fast and sensitive analytical procedure has been developed for the simultaneous separation, determination and quantification of sulfate and glucuronide derivatives of testosterone (T), epitestosterone (E), androsterone (A), etiocholanolone (Etio) and dehydroepiandrosterone (DHEA) in human urine. First, a weak anion-exchange solid-phase extraction support (SPE Oasis WAX) was used for complete and rapid separation of sulfates and glucuronides in two extracts after loading of urine sample (2 mL). Then sulfates were analyzed directly by high-performance liquid chromatography-ion-trap mass spectrometry (LC-MS/MS) with electrospray ionization in negative mode. Chromatographic separation of the targeted sulfoconjugates was achieved using a Waters XBridge C18 column (150 mm x 4.6 mm I.D., 5 microm) with gradient elution. Assay validation demonstrated good performance for instance for T sulfate (TS) and E sulfate (ES) in terms of trueness (89-107%), repeatability (3.4-22%) and intermediate precision (5.8-22%) over the range of 2-200 ng/mL (corresponding to 1.5-147 ng/mL as free steroids). Results obtained on biological samples demonstrated the suitability of this analytical strategy for direct measurement of androgen sulfoconjugates and glucuroconjugates in human urine.


Assuntos
Androgênios/urina , Cromatografia Líquida de Alta Pressão/métodos , Espectrometria de Massas/métodos , Androgênios/análise , Androgênios/isolamento & purificação , Androsterona/análise , Androsterona/isolamento & purificação , Androsterona/urina , Desidroepiandrosterona/análise , Desidroepiandrosterona/isolamento & purificação , Desidroepiandrosterona/urina , Epitestosterona/análise , Epitestosterona/isolamento & purificação , Epitestosterona/urina , Etiocolanolona/análise , Etiocolanolona/isolamento & purificação , Etiocolanolona/urina , Humanos , Reprodutibilidade dos Testes , Extração em Fase Sólida , Testosterona/análise , Testosterona/isolamento & purificação , Testosterona/urina
10.
Anal Chim Acta ; 613(2): 228-37, 2008 Apr 21.
Artigo em Inglês | MEDLINE | ID: mdl-18395062

RESUMO

19-Nortestosterone (nandrolone) major metabolites in human urine are excreted as sulfoconjugated and glucuroconjugated forms. A sensitive and selective liquid chromatography/tandem mass spectrometry (LC/MS/MS) method in negative ESI mode was developed for direct quantification of 19-norandrosterone sulfate (19-NAS) and 19-noretiocholanolone sulfate (19-NES). For both sulfoconjugates, the [M-H](-) ion at m/z 355 and the fragment ion at m/z 97 were used as the precursor and product ions, respectively. The purification method involved a complete and rapid separation of sulfates and glucuronides in two extracts after loading the sample on a weak anion exchange solid phase extraction support (SPE Oasis WAX). Then, sulfates were separated by LC (Uptisphere ODB, 150 mm x 3.0 mm, 5 microm) and analyzed on a linear trap and a triple quadrupole mass spectrometer. The lower limit of detection (LLOD) and lowest limit of quantification (LLOQ) were of 100 pg mL(-1) and 1 ng mL(-1), respectively. Assay validation demonstrated good performances in terms of trueness (92.0-104.9%), repeatability (0.6-7.2%) and intermediate precision (1.3-10.8%) over the range of 1-2500 ng mL(-1). Finally, 19-NAS and 19-NES in urine samples collected after intake of 19-norandrostenedione (nandrolone precursor) were quantified. This assay may be easily implemented to separate glucuronide and sulfate steroids from urine specimens prior to quantification by LC/MS/MS.


Assuntos
Cromatografia Líquida/métodos , Espectrometria de Massas por Ionização por Electrospray/métodos , Esteroides/urina , Espectrometria de Massas em Tandem/métodos , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
11.
Forensic Sci Int ; 178(1): e7-10, 2008 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-18282674

RESUMO

Tribulus terrestris is a nutritional supplement highly debated regarding its physiological and actual effects on the organism. The main claimed effect is an increase of testosterone anabolic and androgenic action through the activation of endogenous testosterone production. Even if this biological pathway is not entirely proven, T. terrestris is regularly used by athletes. Recently, the analysis of two female urine samples by GC/C/IRMS (gas chromatography/combustion/isotope-ratio-mass-spectrometry) conclusively revealed the administration of exogenous testosterone or its precursors, even if the testosterone glucuronide/epitestosterone glucuronide (T/E) ratio and steroid marker concentrations were below the cut-off values defined by World Anti-Doping Agency (WADA). To argue against this adverse analytical finding, the athletes recognized having used T. terrestris in their diet. In order to test this hypothesis, two female volunteers ingested 500 mg of T. terrestris, three times a day and for two consecutive days. All spot urines were collected during 48 h after the first intake. The (13)C/(12)C ratio of ketosteroids was determined by GC/C/IRMS, the T/E ratio and DHEA concentrations were measured by GC/MS and LH concentrations by radioimmunoassay. None of these parameters revealed a significant variation or increased above the WADA cut-off limits. Hence, the short-term treatment with T. terrestris showed no impact on the endogenous testosterone metabolism of the two subjects.


Assuntos
Desidroepiandrosterona/urina , Suplementos Nutricionais , Dopagem Esportivo , Tribulus , Adulto , Androstenóis/urina , Androsterona/urina , Etiocolanolona/urina , Feminino , Humanos , Hormônio Luteinizante/urina , Espectrometria de Massas/métodos , Radioimunoensaio
12.
Forensic Sci Int ; 174(2-3): 166-72, 2008 Jan 30.
Artigo em Inglês | MEDLINE | ID: mdl-17485185

RESUMO

In elite sports, indirect testing of testosterone abuse is mainly based on the testosterone over epitestosterone (T/E) ratio. Since this marker is characterized by a small ratio of intra- to inter-individual variation, it is surprising that current anti-doping strategy uses a screening test based on a population-based limit. From a database of more than 15,000 steroid profiles obtained from routine controls, the collection of steroids profiles of 11 elite athletes followed during 2 years, and a longitudinal study involving 17 amateur athletes, 8 of which were orally administrated testosterone undecanoate pills, we selected 12 case studies to represent the possible scenarios to which the anti-doping laboratories are confronted. Various detection strategies at the disposal of the laboratories are employed and discussed, including isotope ratio mass spectrometry (IRMS) analysis and a Bayesian interpretation of the T/E-time profile. The weak sensitivity versus specificity relation of a population-based limit for the T/E ratio is outlined. As a result, we propose a Bayesian screening test whose T/E threshold progressively evolves from a population basis to a subject basis as the number of individual test results increases. We found that this screening test heightens drastically the capacity to detect testosterone abuse, at no additional financial and administrative expenses for anti-doping authorities.


Assuntos
Dopagem Esportivo , Epitestosterona/urina , Testosterona/urina , Teorema de Bayes , Biomarcadores/urina , Ensaios Clínicos como Assunto , Reações Falso-Positivas , Feminino , Toxicologia Forense , Cromatografia Gasosa-Espectrometria de Massas , Glucuronosiltransferase/genética , Humanos , Masculino , Antígenos de Histocompatibilidade Menor , Polimorfismo Genético , Sensibilidade e Especificidade , Detecção do Abuso de Substâncias/métodos , Testosterona/administração & dosagem , Testosterona/análogos & derivados , Congêneres da Testosterona/administração & dosagem
13.
Rapid Commun Mass Spectrom ; 21(24): 3956-62, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17990278

RESUMO

Since GHB (gamma-hydroxybutyric acid) is naturally produced in the human body, clinical and forensic toxicologists must be able to discriminate between endogenous levels and a concentration resulting from exposure. To suggest an alternative to the use of interpretative concentration cut-offs, the detection of exogenous GHB in urine specimens was investigated by means of gas chromatography/combustion/isotope ratio mass spectrometry (GC/C/IRMS). GHB was isolated from urinary matrix by successive purification on Oasis MCX and Bond Elute SAX solid-phase extraction (SPE) cartridges prior to high-performance liquid chromatography (HPLC) fractioning using an Atlantis dC18 column eluted with a mixture of formic acid and methanol. Subsequent intramolecular esterification of GHB leading to the formation of gamma-butyrolactone (GBL) was carried out to avoid introduction of additional carbon atoms for carbon isotopic ratio analysis. A precision of 0.3 per thousand was determined using this IRMS method for samples at GHB concentrations of 10 mg/L. The (13)C/(12)C ratios of GHB in samples of subjects exposed to the drug ranged from -32.1 to -42.1 per thousand, whereas the results obtained for samples containing GHB of endogenous origin at concentration levels less than 10 mg/L were in the range -23.5 to -27.0 per thousand. Therefore, these preliminary results show that a possible discrimination between endogenous and exogenous GHB can be made using carbon isotopic ratio analyses.


Assuntos
Cromatografia Gasosa-Espectrometria de Massas/métodos , Hidroxibutiratos/urina , Detecção do Abuso de Substâncias/métodos , Isótopos de Carbono/análise , Medicina Legal/métodos , Humanos , Hidroxibutiratos/farmacocinética , Reprodutibilidade dos Testes
15.
J Chromatogr B Analyt Technol Biomed Life Sci ; 852(1-2): 491-6, 2007 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-17321808

RESUMO

19-Norandrosterone sulfate (19-NAS) is the sulfoconjugated form of 19-norandrosterone (19-NA), the major metabolite of the steroid nandrolone. A sensitive and accurate liquid chromatography/tandem mass spectrometry (LC-MS/MS) assay was developed for the direct measurement of 19-NAS in human urine samples. The method involved a quaternary amine SPE protocol and subsequently injection of the extract onto an analytical column (Uptisphere ODB, 150 mm x 3.0 mm, 5 microm) for chromatographic separation and mass spectrometry detection in negative electrospray ionisation mode. The sulfoconjugate of 19-NA was identified in urine by comparison of mass spectra and retention time with a reference substance. The limit of detection (LOD) and lowest limit of quantification (LLOQ) of 19-NAS were of 40 pg/mL and 200 pg/mL, respectively. For a nominal concentration of 2 ng/mL, recovery (94%), intra-day precision (2.7%), intra-assay precision (6.6%) and inter-assay precision (14.3%) were determined. Finally, this analytical method was applied for quantifying the concentration of 19-NAS in doping samples, using calibration curves (0.2-20 ng/mL) and the standard-addition method. The results show the feasibility of applying this LC-MS/MS assay as a complementary tool to detect misuse of nandrolone or nandrolone precursors.


Assuntos
Cromatografia Líquida/métodos , Estranos/urina , Espectrometria de Massas por Ionização por Electrospray/métodos , Espectrometria de Massas em Tandem/métodos , Humanos , Padrões de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
16.
Biostatistics ; 8(2): 285-96, 2007 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-16785250

RESUMO

We developed a test that compares sequential measurements of a biomarker against previous readings performed on the same individual. A probability mass function expresses prior information on interindividual variations of intraindividual parameters. Then, the model progressively integrates new readings to more accurately quantify the characteristics of the individual. This Bayesian framework generalizes the two main approaches currently used in forensic toxicology for the detection of abnormal values of a biomarker. The specificity is independent of the number n of previous test results, with a model that gradually evolves from population-derived limits when n = 0 to individual-based cutoff thresholds when n is large. We applied this model to detect abnormal values in an athlete's steroid profile characterized by the testosterone over epitestosterone (T/E) marker. A cross-validation procedure was used for the estimation of prior densities as well as model validation. The heightened sensitivity/specificity relation obtained on a large data set shows that longitudinal monitoring of an athlete's steroid profile may be used efficiently to detect the abuse of testosterone and its precursors in sports. Mild assumptions make the model interesting for other areas of forensic toxicology.


Assuntos
Teorema de Bayes , Interpretação Estatística de Dados , Epitestosterona/urina , Estudos Longitudinais , Modelos Estatísticos , Testosterona/urina , Biomarcadores/análise , Biomarcadores/urina , Dopagem Esportivo , Humanos , Masculino , Sensibilidade e Especificidade
17.
J Pharm Biomed Anal ; 43(1): 270-6, 2007 Jan 04.
Artigo em Inglês | MEDLINE | ID: mdl-16884883

RESUMO

Urine luteinizing hormone (LH) concentration is routinely measured in all anti-doping laboratories to exclude recombinant LH abuse and to test any potential alteration of the hypophyseal-gonadal axis. Before establishing proper reference values among professional top level athletes, an extended validation of two commercial immunoassays for LH measurements was performed. Elecsys 1010 and Access are two automated immunoanalyzers for central laboratories. The limit of detection, the limit of quantification, intra-laboratory, inter-technique correlation, precision, accuracy were determined. Furthermore, reference urinary LH distribution values for male and female top level athletes were determined. Stability studies of LH in urine following freezing and thawing cycles (n=3) as well as storage conditions at room temperature, 4 degrees C and -20 degrees C were performed. Male and female subjects showed important urinary corrected (specific gravity correction) LH distribution differences. Intra-assay precision for the Access analyzer was less than 8.0% whereas inter-assay was close to 11%. Intra and inter-assay precision for the Elecsys 1010 analyzer was slightly better. A good inter-technique correlation was obtained ([Elecsys 1010]=1.0434[Access]+1.146, R=0.953). No urinary LH loss was observed after two freezing and thawing cycles. On the other hand, time and bad storage conditions such as elevated temperature can deteriorate rapidly urinary LH. In conclusion, both analyzers showed acceptable performances and are suitable for screening anti-doping analyses. Each anti-doping laboratory has to settle its own reference distribution values and then determine when to launch a confirmation procedure. This takes place then depending on the positivity criteria the anti-doping laboratory has established and validated. This study also clearly showed that the time delay between the urine collection and the analysis should be reduced as much as possible and urine samples should be transported in optimal conditions (low temperature and quickly) to decrease urinary LH deterioration.


Assuntos
Dopagem Esportivo , Hormônio Luteinizante/urina , Adulto , Reações Cruzadas , Feminino , Congelamento , Humanos , Imunoensaio , Técnicas Imunoenzimáticas , Masculino , Reprodutibilidade dos Testes , Manejo de Espécimes , Esportes
18.
Artigo em Inglês | MEDLINE | ID: mdl-16891159

RESUMO

A simple method using liquid chromatography-linear ion trap mass spectrometry for simultaneous determination of testosterone glucuronide (TG), testosterone sulfate (TS), epitestosterone glucuronide (EG) and epitestosterone sulfate (ES) in urine samples was developed. For validation purposes, a urine containing no detectable amount of TG, TS and EG was selected and fortified with steroid conjugate standards. Quantification was performed using deuterated testosterone conjugates to correct for ion suppression/enhancement during ESI. Assay validation was performed in terms of lower limit of detection (1-3ng/mL), recovery (89-101%), intraday precision (2.0-6.8%), interday precision (3.4-9.6%) and accuracy (101-103%). Application of the method to short-term stability testing of urine samples at temperature ranging from 4 to 37 degrees C during a time-storage of a week lead to the conclusion that addition of sodium azide (10mg/mL) is required for preservation of the analytes.


Assuntos
Epitestosterona/urina , Espectrometria de Massas/métodos , Testosterona/urina , Calibragem , Pré-Escolar , Feminino , Humanos , Sensibilidade e Especificidade
19.
Steroids ; 71(5): 364-70, 2006 May.
Artigo em Inglês | MEDLINE | ID: mdl-16438998

RESUMO

The metabolic effect of multiple oral testosterone undecanoate (TU) doses over 4 weeks was assessed in seven voluntary men. The protocol was designed to detect accumulation of the substance by choosing the appropriate spot urines collections time and to study the urinary clearance of the substance after weeks of treatment. Urines were analysed by a new GC/C/isotope ratio mass spectrometry (IRMS) method to establish the delta(13)C-values of testosterone metabolites (androsterone and etiocholanolone) together with an endogenous reference compound (16(5alpha)-androsten-3alpha-ol). The significant differences in inter-individual metabolism following TU intake was illustrated by large variations in delta(13)C-values of both T metabolites (maximum Deltadelta(13)C-values = 5.5 per thousand), as well as by very stable longitudinal T/E profiles and carbon isotopic ratios in the first hours following administration. According to T/E ratios and delta(13)C-values, the washout period after 80 mg TU intake was less than 48 h for all subjects and no accumulation phenomenon was observed upon chronic oral administration.


Assuntos
Dopagem Esportivo , Variação Genética , Detecção do Abuso de Substâncias/métodos , Testosterona/análogos & derivados , Administração Oral , Adulto , Isótopos de Carbono , Cromatografia Gasosa-Espectrometria de Massas/métodos , Humanos , Masculino , Valores de Referência , Testosterona/administração & dosagem , Testosterona/metabolismo , Testosterona/urina , Fatores de Tempo
20.
Forensic Sci Int ; 163(1-2): 148-51, 2006 Nov 10.
Artigo em Inglês | MEDLINE | ID: mdl-16337352

RESUMO

The case of seven urine samples collected for anti-doping purposes during a cycling stage race with moderately elevated testosterone and epitestosterone ratio (T/E) is reported. The very low probability of having all seven urine samples with such similar elevated T/E ratio (from 3.2 to 4.7) was very suspicious. Different pattern classification tools were tested to categorize the most similar steroid profiles, but none of the models enabled a clear classification of the different urine samples. Subsequently, genetic profiling of all urine samples was performed and demonstrated that three of the seven samples were collected from the same cyclist. Finally, the International Federation confirmed DNA profiling results. This suggests that urinary steroid data using several methodologies are not appropriate for identification purposes and to an extent not unique to individuals.


Assuntos
Ciclismo , Dopagem Esportivo , Epitestosterona/urina , Manejo de Espécimes , Testosterona/urina , Impressões Digitais de DNA , Cromatografia Gasosa-Espectrometria de Massas , Humanos , Manejo de Espécimes/normas , Detecção do Abuso de Substâncias
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...