Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Rofo ; 173(10): 942-8, 2001 Oct.
Artigo em Alemão | MEDLINE | ID: mdl-11588684

RESUMO

UNLABELLED: Comparison of digital selenium radiography with an analog screen-film system in the diagnostic process of pneumoconiosis according to ILO classification. PURPOSE: The aim of the study was to determine the diagnostic value of digital selenium radiography in patients with pneumoconiosis. For this purpose chest x-rays by digital selenium radiography and analog screen-film system were compared according to the ILO classification of pneumoconiosis. METHOD: After approval of the study by the local ethic commission and the Federal German Office for Radiation Protection 50 patients were subjected to x-rays by digital selenium radiography (Thoravision; Philips Medical Systems, Hamburg, Germany) and analog screen-film system of the same day within the scope of an industrial medicine preventive checkup. Four investigators rated the chest x-rays according to the ILO classification of pneumoconiosis. RESULTS: The findings demonstrated by chest x-rays according to ILO classification were rated similar by digital selenium radiography and analog screen film systems. Image quality of the digital pictures was rated significantly better. CONCLUSION: The use of digital selenium radiography in evaluating chest x-rays according to the ILO classification does not result in over- or underestimation of pulmonary pathologies. Hence, in the diagnosis of pneumoconiosis, digital selenium radiography can replace the tested analog screen-film system.


Assuntos
Mineração , Pneumoconiose/diagnóstico por imagem , Intensificação de Imagem Radiográfica , Selênio , Ecrans Intensificadores para Raios X , Adulto , Idoso , Humanos , Masculino , Programas de Rastreamento , Pessoa de Meia-Idade , Pneumoconiose/classificação , Sensibilidade e Especificidade
2.
Rofo ; 167(5): 509-15, 1997 Nov.
Artigo em Alemão | MEDLINE | ID: mdl-9440898

RESUMO

PURPOSE: Development and experimental validation of a method tor the quantification of pulmonary oedema by measurement of total lung water and intravascular lung water and by calculation of extravascular lung water. MATERIAL AND METHODS: Isolated sheep lung preparations with unilateral pulmonary oedema were perfused (pulsatile pump) and examined under ventilatory arrest and during ventilation. Total lung water was calculated from proton density obtained from a multi-spin echo sequence and gravimetrically (reference method). Pulmonary intravascular volume was calculated from signal intensity histograms obtained from 3D-TOF MR-angiograms before and after application of the macromolecular contrast medium gadolinium-DTPA-polylysine. The reference method was a dye-dilution technique. Extravascular lung water was calculated as the difference between total lung water and pulmonary intravascular volume. RESULTS: Under ventilatory arrest, the magnetic resonance technique for the measurement of extravascular lung water correlated well with the reference technique (r = 0.89, n = 42 lungs). In 10 lungs the correlation coefficients were r = 0.95 (ventilatory arrest) and r = 0.92 (ventilated lungs). CONCLUSION: The results demonstrate that magnetic resonance imaging enhanced by a macromolecular contrast medium may be applicable for quantification of pulmonary oedema.


Assuntos
Meios de Contraste , Gadolínio DTPA , Angiografia por Ressonância Magnética , Polilisina/análogos & derivados , Edema Pulmonar/diagnóstico , Animais , Técnica de Diluição de Corante , Água Extravascular Pulmonar , Substâncias Macromoleculares , Angiografia por Ressonância Magnética/métodos , Respiração , Ovinos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...