Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
IEEE Trans Med Imaging ; PP2024 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-38640053

RESUMO

3D Imaging of the human heart at high frame rate is of major interest for various clinical applications. Electronic complexity and cost has prevented the dissemination of 3D ultrafast imaging into the clinic. Row column addressed (RCA) transducers provide volumetric imaging at ultrafast frame rate by using a low electronic channel count, but current models are ill-suited for transthoracic cardiac imaging due to field-of-view limitations. In this study, we proposed a mechanically curved RCA with an aperture adapted for transthoracic cardiac imaging (24 × 16 mm²). The RCA has a toroidal curved surface of 96 elements along columns (curvature radius rC = 4.47 cm) and 64 elements along rows (curvature radius rR = 3 cm). We implemented delay and sum beamforming with an analytical calculation of the propagation of a toroidal wave which was validated using simulations (Field II). The imaging performance was evaluated on a calibrated phantom. Experimental 3D imaging was achieved up to 12 cm deep with a total angular aperture of 30° for both lateral dimensions. The Contrast-to-Noise ratio increased by 12 dB from 2 to 128 virtual sources. Then, 3D Ultrasound Localization Microscopy (ULM) was characterized in a sub-wavelength tube diameter. Finally, 3D ULM was demonstrated on a perfused ex-vivo swine heart to image the coronary microcirculation.

2.
IEEE Trans Med Imaging ; 40(12): 3358-3368, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34048341

RESUMO

Row column addressing (RCA) transducers have the potential to provide volumetric imaging at ultrafast frame rate using a low channel count over a large field of view. In previous works we have shown that vascular imaging of large arteries as well as functional neuroimaging of the rat brain were feasible using RCA orthogonal plane wave imaging (OPW), but these applications required to transmit many plane waves, significantly reducing the frame rate. In this study, we introduce XDoppler imaging, a novel method to increase the performances of RCA flow imaging by taking advantage of the blood spatial decorrelation statistics combined with the limited spatial overlap of the point spread functions (PSF) of the two orthogonal apertures of the RCA transducer. We provide at first a theoretical basis to understand how the correlation operation reduces the sidelobe level. Then, we demonstrate both in vitro and in vivo in the human carotid artery and in the rat brain that XDoppler provides a significant gain in contrast-to-noise ratio (CNR) (between 3 and 6 dB depending on the application) compared to OPW. This improvement also leads to a sensitivity increase in the rat brain as more blood vessels are detected by XDoppler imaging.


Assuntos
Hemodinâmica , Imageamento Tridimensional , Animais , Artérias Carótidas/diagnóstico por imagem , Imagens de Fantasmas , Ratos , Ultrassonografia
3.
IEEE Trans Med Imaging ; 39(6): 1884-1893, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-31841403

RESUMO

Functional ultrasound imaging (fUS) recently emerged as a promising neuroimaging modality to image and monitor brain activity based on cerebral blood volume response (CBV) and neurovascular coupling. fUS offers very good spatial and temporal resolutions compared to fMRI gold standard as well as simplicity and portability. It was recently extended to 4D fUS imaging in preclinical settings although this approach remains limited and complex. Indeed 4D fUS requires a 2D matrix probe and specific hardware able to drive the N2 elements of the probe with thousands of electronic channels. Several under-sampling approaches are currently investigated to limit the channel count and spread ultrasound 4D modalities. Among them, the Row Column Addressing (RCA) approach combined with ultrafast imaging is a compelling alternative using only N + N channels. We present a large field of view RCA probe prototype of 128 + 128 channels and 15 MHz central frequency adapted for preclinical imaging. Based on the Orthogonal Plane Wave compounding scheme, we were able to perform 4D vascular brain acquisitions at high volume rate. Doppler volumes of the whole rat brain were obtained in vivo at high rates (23 dB CNR at 156 Hz and 19 dB CNR at 313 Hz). Visual and whiskers stimulations were performed and the corresponding CBV increases were reconstructed in 3D with successful functional activation detected in the superior colliculus and somato-sensorial cortex respectively. This proof of concept study demonstrates for the first time the use of a low-channel count RCA array for in vivo 4D fUS imaging in the whole rat brain.


Assuntos
Neuroimagem , Ultrassonografia Doppler , Animais , Encéfalo/diagnóstico por imagem , Imageamento Tridimensional , Ratos , Ultrassonografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...