Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
BMC Musculoskelet Disord ; 23(1): 447, 2022 May 12.
Artigo em Inglês | MEDLINE | ID: mdl-35549696

RESUMO

BACKGROUND: Surgical treatment of displaced distal radius fractures (DRF) in older patients has increased, despite lacking evidence of its superiority over non-operative treatment. How treatment choice affects these patients after the initial 12-month period remains unknown. This study presents a clinical and radiographic follow up at an average of 3 years after treatment in the context of a randomized clinical trial comparing outcomes in patients aged ≥70 years, with a dorsally displaced distal radius fracture treated either surgically with volar locking plate or non-operatively. METHODS: Between 2009 and 2017, 140 patients aged ≥70 years with dorsally displaced DRF were randomized to surgery with volar locking plate (VLP) or non-operative treatment. At an average of 3 years after inclusion the participants were invited to an additional follow-up. The primary outcome was Patient Rated Wrist Evaluation (PRWE). Secondary outcomes included additional Patient Reported Outcome Measures (PROM), grip strength, range of motion, complications and radiological results. RESULTS: Sixty six patients were available for a 3 year follow-up, 33 in the non-operatively treated group and 33 in the VLP-group. The mean age at injury was 77 years. At 3 years the median PRWE was better (0 points) in the VLP-group than in the non-operative treatment group (9 points) p-value: 0.027. No statistically significant difference was found in Disabilities of the Arm, Hand, and Shoulder (DASH), EuroQol 5 Dimensions (EQ-5D) or grip strength. Total arc of range of motion was larger in the operatively treated group. No significant difference in osteoarthritis was found. Both groups had regained grip strength. The complication rate was similar. Outcomes improved from the 1 year to the 3 year follow-up. CONCLUSIONS: Surgery with volar locking plate gave less long-term disability compared to non-operative treatment for severely displaced distal radius fractures in patients aged ≥70 years. Our findings were statistically significant but in the lower range of clinical importance. TRIAL REGISTRATION: The study was registered at : NCT02154620 03/06/2014 and NCT01268397 30/12/2010. Ethical approval was obtained from Ethical Committee in Stockholm, Sweden (2009/37-31/3, 2013/105-31/2, 2014/1041-32, 2017/611-32).


Assuntos
Fraturas do Rádio , Idoso , Placas Ósseas , Seguimentos , Fixação Interna de Fraturas/efeitos adversos , Fixação Interna de Fraturas/métodos , Humanos , Fraturas do Rádio/diagnóstico por imagem , Fraturas do Rádio/cirurgia , Amplitude de Movimento Articular , Resultado do Tratamento
2.
PLoS One ; 15(10): e0240377, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33031472

RESUMO

AIM: To investigate the cost-effectiveness of Volar Locking Plate (VLP) compared to External Fixation (EF) for unstable dorsally displaced distal radius fractures in a 3-year perspective. METHODS: During 2009-2013, patients aged 50-74 years with an unstable dorsally displaced distal radius fracture were randomised to VLP or EF. Primary outcome was the incremental cost-effectiveness ratio (ICER) for VLP compared with EF. Data regarding health effects (Quality-adjusted life years, QALYs) was prospectively collected during the trial period until 3 years after surgery. Cost data was collected retrospectively for the same time period and included direct and indirect costs (production loss). RESULTS: One hundred and thirteen patients (VLP n = 58, EF n = 55) had complete data until 3 years and were used in the analysis. At one year, the VLP group had a mean incremental cost of 878 euros and a gain of 0.020 QALYs compared with the EF group, rendering an ICER of 43 900 euros per QALY. At three years, the VLP group had a mean incremental cost of 1 082 euros and a negative incremental effect of -0.005 QALYs compared to the EF group, which means that VLP was dominated by EF. The probability that VLP was cost-effective compared to EF at three years, was lower than 50% independent of the willingness to pay per QALY. CONCLUSION: Three years after distal radius fracture surgery, VLP fixation resulted in higher costs and a smaller effect in QALYs compared to EF. Our results indicate that it is uncertain if VLP is a cost-effective treatment of unstable distal radius fractures compared to EF.


Assuntos
Análise Custo-Benefício , Fixação de Fratura/economia , Fraturas do Rádio/cirurgia , Idoso , Placas Ósseas , Fixadores Externos , Feminino , Seguimentos , Fixação de Fratura/métodos , Humanos , Pessoa de Meia-Idade , Anos de Vida Ajustados por Qualidade de Vida , Estudos Retrospectivos
3.
J Bone Joint Surg Am ; 101(11): 961-969, 2019 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-31169572

RESUMO

BACKGROUND: The usage of volar locking plate fixation for distal radial fractures has increased in older patient populations, despite the fact that surgical treatment in the elderly population has not clearly been proven to be superior to nonoperative treatment. The purpose of the present study was to compare nonoperative treatment with volar locking plate fixation with regard to clinical outcome for elderly patients with dorsally displaced distal radial fractures. METHODS: In this study, 140 patients were randomly allocated to nonoperative treatment with a plaster splint (n = 72) or volar locking plate fixation (n = 68). The outcome variables were the Patient-Rated Wrist Evaluation (PRWE) score, Disabilities of the Arm, Shoulder and Hand (DASH) questionnaire score, EuroQol-5 Dimensions (EQ-5D) score, range of motion, grip strength, radiographic outcomes, and complications. Evaluation was performed at 3 and 12 months by unblinded observers. RESULTS: At 3 months, 122 patients were evaluated, and at 12 months, 119 patients were evaluated. At 3 months, the volar locking plate group, compared with the nonoperative treatment group, had a better median PRWE score (10.3 compared with 35.5 points; p = 0.002), DASH score (14.4 compared with 29.2 points; p = 0.016), and grip strength (71.0% of the uninjured hand compared with 53.9%; p < 0.001). Significant differences in favor of the volar locking plate group remained at 12 months; compared with the nonoperative treatment group, the volar locking plate group had a better median PRWE score (7.5 points compared with 17.5 points; p = 0.014), DASH score (8.3 points compared with 19.9 points; p = 0.028), and grip strength (96.8% compared with 80.0%; p = 0.001). Radiographic measurements favored volar locking plate fixation at 3 and 12 months. Complication rates were similar, with 11% major complications in the nonoperative group compared with 14% major complications in the volar locking plate group (p = 0.606) and 11% minor complications in the nonoperative group compared with 20% minor complications in the volar locking plate group (p = 0.197). CONCLUSIONS: The PRWE scores, DASH scores, and grip strength were better for the volar locking plate group compared with the nonoperative group at 3 and 12 months. The complication rates were similar. Our results imply that there is a benefit for the elderly patient with an unstable dorsally displaced distal radial fracture to be treated with a volar locking plate. LEVEL OF EVIDENCE: Therapeutic Level I. See Instructions for Authors for a complete description of levels of evidence.


Assuntos
Fixação de Fratura/métodos , Fraturas do Rádio/terapia , Contenções , Idoso , Idoso de 80 Anos ou mais , Feminino , Força da Mão , Humanos , Masculino , Qualidade de Vida , Amplitude de Movimento Articular
4.
J Hand Surg Am ; 44(1): 18-26, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30420192

RESUMO

PURPOSE: To determine if a volar locking plate (VLP) is superior to external fixation (EF) 3 years after surgery for unstable, dorsally displaced, distal radius fractures caused by low-energy injury in patients 50 to 74 years of age. METHODS: During 2009 to 2013, 140 patients with an unstable dorsally displaced distal radius fracture were randomized to either VLP or EF. One hundred eighteen patients (EF 56, VLP 62) were available for a 3-year follow-up. The primary outcome was the Disabilities of the Arm, Shoulder, and Hand (DASH) score at 3 years. Secondary outcomes were Patient-Related Wrist Evaluation (PRWE) score, EuroQol-5 Dimensions (EQ-5D) score, range of motion (ROM), grip strength, and radiological signs of osteoarthritis (OA) at 3 years. Moreover, reoperations and minor complications during the first 3 years were recorded. RESULTS: There were no differences regarding DASH, PRWE, EQ-5D, ROM or grip strength. The reoperation rate was 21% (13 of 62) in the VLP group compared with 14% (8 of 56) in the EF group. The OA rate was 42% (25 of 59) in the VLP group compared with 28% (15 of 53) in the EF group. CONCLUSIONS: Three years after surgery for unstable dorsally displaced distal radius fractures, the clinical and radiological results for VLP and EF were comparable. TYPE OF STUDY/LEVEL OF EVIDENCE: Therapeutic II.


Assuntos
Placas Ósseas , Fixadores Externos , Fixação Interna de Fraturas , Instabilidade Articular/cirurgia , Fraturas do Rádio/cirurgia , Idoso , Avaliação da Deficiência , Feminino , Seguimentos , Força da Mão , Humanos , Instabilidade Articular/etiologia , Instabilidade Articular/fisiopatologia , Masculino , Pessoa de Meia-Idade , Osteoartrite/diagnóstico por imagem , Osteoartrite/fisiopatologia , Qualidade de Vida , Fraturas do Rádio/fisiopatologia , Amplitude de Movimento Articular , Reoperação/estatística & dados numéricos , Articulação do Punho/diagnóstico por imagem , Articulação do Punho/fisiopatologia , Articulação do Punho/cirurgia
5.
PLoS One ; 13(11): e0207702, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30444926

RESUMO

OBJECTIVES: After recent technical innovations of fracture surgery implants, treatment traditions are changing for distal radius fractures, the most common orthopaedic injury. The aim of this study was to determine if the choice of surgical method for treatment of distal radius fractures differ between healthcare regions in Sweden. METHOD: The study was based on all (n = 22 378) adult patients who were registered with a surgical procedure due to a distal radius fracture during 2010-2013 in Sweden. Consecutive data was collected from the Swedish National Patient Registry. RESULTS: The proportions of use of surgical method varied among the 21 healthcare regions between 41% and 95% for internal fixation, between 2.3% and 44% for percutaneous fixation and between 0.6% and 19% for external fixation. Differences between regions were statistically significant in all but 6 comparisons when controlled for age and gender. Incidence rates of surgical treatment of a distal radius fracture varied between 4.2 and 9.2/10 000 person-years. CONCLUSION: We conclude that there is a large variation in operative management of distal radius fractures between Swedish healthcare regions.


Assuntos
Fixação de Fratura/classificação , Fixação de Fratura/estatística & dados numéricos , Fraturas do Rádio/cirurgia , Adulto , Fixadores Externos/estatística & dados numéricos , Feminino , Fixação Interna de Fraturas/estatística & dados numéricos , Humanos , Incidência , Fixadores Internos/estatística & dados numéricos , Masculino , Suécia
6.
J Shoulder Elbow Surg ; 20(7): 1025-33, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21783385

RESUMO

BACKGROUND: The aim of the study was to report the 2-year outcome after a displaced 4-part fracture of the proximal humerus in elderly patients randomized to treatment with a hemiarthroplasty (HA) or nonoperative treatment. PATIENTS AND METHODS: We included 55 patients, mean age 77 (range, 58-92) years, 86% being women. Follow-up examinations were done at 4, 12, and 24 months. The main outcome measures were health-related quality of life (HRQoL) according to the EQ-5D and the DASH and Constant scores. RESULTS: At the final 2-year follow-up the HRQoL was significantly better in the HA group compared to the nonoperative group, EQ-5D (index) score 0.81 compared to 0.65 (P = .02). The results for DASH and pain assessment were both in favor of the HA group, DASH score 30 versus 37 (P = .25) and pain according to VAS 15 versus 25 (P = .17). There were no significant differences regarding the Constant score or range of motion (ROM). Both groups achieved a mean flexion of approximately 90-95° and a mean abduction of 85-90°. The need for additional surgery was low: 3 patients in the HA group and 1 patient in the nonoperative group. CONCLUSION: The results of the study demonstrated a significant advantage in quality of life in favor of HA, as compared to nonoperative treatment in elderly patients with a displaced 4-part fracture of the proximal humerus. The main advantage of HA appeared to be less pain while there were no differences in ROM.


Assuntos
Artroplastia de Substituição/métodos , Aparelhos Ortopédicos , Modalidades de Fisioterapia , Fraturas do Ombro/terapia , Idoso , Idoso de 80 Anos ou mais , Avaliação da Deficiência , Feminino , Humanos , Prótese Articular , Masculino , Pessoa de Meia-Idade , Medição da Dor , Qualidade de Vida , Amplitude de Movimento Articular
7.
J Shoulder Elbow Surg ; 20(5): 747-55, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21435907

RESUMO

BACKGROUND: The aim of the study was to report the 2-year outcome after a displaced 3-part fracture of the proximal humerus in elderly patients randomized to treatment with a locking plate or nonoperative treatment. PATIENTS AND METHODS: We included 60 patients, mean age 74 years (range, 56-92), 81% being women. The main outcome measures were the Constant and Disabilities of the Arm, Shoulder and Hand (DASH) scores and the health-related quality of life (HRQoL) according to the EQ-5D. RESULTS: At the final 2-year follow-up, the results for range of motion (ROM), function and HRQoL were all in favor of the locking plate group. The mean flexion in the locking plate group was 120° compared to 111° in the nonoperative group (P = .36) and the mean abduction was 114° compared to 106° (P = .28). The corresponding values for the Constant score were 61 versus 58 (P = .64), for DASH 26 versus 35 (P = .19), and the mean EQ-5D (index) score was 0.70 compared to 0.59 (P = .26). In spite of good primary reduction in 86% of the fractures in the locking plate group, 13% of the patients had a fracture complication requiring a major reoperation and 17% had a minor reoperation. CONCLUSION: The results of our study indicate an advantage in functional outcome and HRQoL in favor of the locking plate compared to nonoperative treatment in elderly patients with a displaced 3-part fracture of the proximal humerus, but at the cost of additional surgery in 30% of the patients.


Assuntos
Placas Ósseas , Fixação Interna de Fraturas/métodos , Consolidação da Fratura , Amplitude de Movimento Articular/fisiologia , Fraturas do Ombro/cirurgia , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Fraturas do Ombro/fisiopatologia , Resultado do Tratamento
8.
J Shoulder Elbow Surg ; 19(6): 814-22, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20303288

RESUMO

BACKGROUND: The aim of the study was to report the 2-year outcome after a displaced 2-part fracture of the proximal humerus in elderly patients treated with a locking plate, including an assessment of the health-related quality of life (HRQoL). MATERIAL AND METHODS: We included 50 patients, mean age 75 (range, 55-93) years with 80% women. The fracture inclusion criteria were a displacement of the shaft of >50% of its width and/or >45 degrees of angulation. Follow-up examinations were performed at 4, 12, and 24 months. The main outcome measures were the Constant and DASH scores and HRQoL according to the EQ-5D. RESULTS: Eight patients (16%) were re-operated upon during the study period. At the final follow-up the mean Constant score was 61 and the mean DASH score 32. The EQ-5D (index) score decreased from 0.86 before the fracture to 0.62 at 4 months. At 12 months the EQ-5D (index) score was 0.65 and at 24 months 0.68. The values at all follow-ups were significantly lower than before the fracture (P < .001 in all 3 comparisons). CONCLUSION: Locking plates appear to be a good treatment alternative in elderly patients with a displaced 2-part fracture of the surgical neck of the proximal humerus with an acceptable complication rate and an acceptable functional outcome; however, rigorous attention has to be paid to avoid screw penetration. Despite the overall acceptable functional outcome, the patients reported a substantial negative effect upon their HRQoL.


Assuntos
Placas Ósseas , Fixação Interna de Fraturas/instrumentação , Qualidade de Vida , Amplitude de Movimento Articular/fisiologia , Fraturas do Ombro/cirurgia , Idoso , Idoso de 80 Anos ou mais , Parafusos Ósseos , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Desenho de Prótese , Fraturas do Ombro/fisiopatologia , Fraturas do Ombro/psicologia , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...