Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Surg Technol Int ; 39: 317-320, 2021 10 26.
Artigo em Inglês | MEDLINE | ID: mdl-34699598

RESUMO

Caval filters are placed in the inferior vena cava (IVC) to prevent pulmonary thromboembolism in patients with deep vein thrombosis. If there is no indication for thrombo-embolic risk prevention, the filter can be removed to reduce potential filter-related complications. Advanced endovascular techniques are frequently used to retrieve IVC filters. We describe an alternative filter-removal technique for use when standard techniques are not practicable. In our method, the filter hook is embedded within the IVC wall. To retrieve it, a long introducer is inserted; a guidewire and the "loop snare" retrieval system are then advanced through it with a coaxial system and positioned below the filter at the level of the common iliac vein confluence. The guidewire is then passed through the loop, creating a "sling" around the filter which allows the application of traction from the bottom upwards, releasing the hook from the wall. The loop is then held under tension with the filter aligned in the IVC lumen, and the introducer is advanced distally to completely cover the filter, allowing complete retrieval of the filter without damaging the vessel walls. This modified Sling technique is a safe and feasible method for complicated IVC filter retrieval.


Assuntos
Procedimentos Endovasculares , Filtros de Veia Cava , Remoção de Dispositivo , Humanos , Estudos Retrospectivos , Resultado do Tratamento , Veia Cava Inferior/cirurgia
2.
Emerg Radiol ; 28(5): 877-885, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34218365

RESUMO

PURPOSE: The study's aim is to analyse the diagnostic performance of chest radiography (CXR) in patients with suspected coronavirus disease 19 (COVID-19). METHODS: We retrospectively considered 826 consecutive patients with suspected COVID-19 presenting to our emergency department (ED) from February 21 to March 31, 2020, in a high disease prevalence setting. We enrolled patients who underwent CXR and rhino-oropharyngeal swab for real-time reverse transcription-polymerase chain reaction (rRT-PCR). CXRs were evaluated by an expert radiologist; a second independent analysis was performed by two residents in consensus. All readers, blinded to rRT-PCR results, classified CXRs positive/negative depending on presence/absence of typical findings of COVID-19, using rRT-PCR as reference standard. RESULTS: We finally analysed 680 patients (median age 58); 547 (80%) tested positive for COVID-19. The diagnostic performance of CXR, interpreted by the expert reader, was as follows: sensitivity (79.0%; 95% CI: 75.3-82.3), specificity (81.2%; 95% CI: 73.5-87.5), PPV (94.5%;95% CI: 92.0-96.4), NPV (48.4%; 95% CI: 41.7-55.2), and accuracy (79.3%; 95% CI: 76.0-82.2). For the residents: sensitivity (75.1%; 95% CI: 71.2-78.7), specificity (57.9%; 95% CI: 49.9-66.4), PPV (88.0%; 95% CI: 84.7-90.8), NPV (36.2%; 95% CI: 29.7-43.0), and accuracy (71.6%; 95% CI: 68.1-75.0). We found a significant difference between the reporting sensitivity (p = 0.013) and specificity (p < 0.0001) of expert radiologist vs residents. CXR sensitivity was higher in patients with symptom onset > 5 days before ED presentation compared to ≤ 5 days (84.4% vs 70.7%). CONCLUSIONS: CXR showed a sensitivity of 79% and a specificity of 81% in diagnosing viral pneumonia in symptomatic patients with clinical suspicion of COVID-19. Further studies in lower prevalence settings are needed.


Assuntos
COVID-19 , Hospitais , Humanos , Pessoa de Meia-Idade , Prevalência , Radiografia , Radiografia Torácica , Estudos Retrospectivos , SARS-CoV-2 , Sensibilidade e Especificidade
3.
Semin Ultrasound CT MR ; 42(1): 85-94, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33541592

RESUMO

The strict correlation between abnormal invasive placentation and postpartum hemorrhage suggests that a widespread antenatal diagnosis of placental anomalies would improve the management of these challenging patients; acting preventive solutions at the moment of delivery reduces blood loss and avoid hysterectomies. The role of endovascular procedures in this field has been encouraged by multiple studies reporting prophylactic uterine arteries embolization and iliac/aortic balloon catheters positioning. This paper aims to review the main imaging diagnostic findings of placental implant anomalies and summarize the principal preventive endovascular strategies proposed in literature.


Assuntos
Procedimentos Endovasculares/métodos , Imageamento por Ressonância Magnética/métodos , Hemorragia Pós-Parto/diagnóstico por imagem , Hemorragia Pós-Parto/prevenção & controle , Ultrassonografia/métodos , Feminino , Humanos , Hemorragia Pós-Parto/cirurgia , Gravidez
4.
Ann Gastroenterol ; 33(6): 675-679, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33162745

RESUMO

BACKGROUND: The aim of this study was to evaluate the diagnosis and management of postoperative bile leaks, reporting typical diagnostic findings and available percutaneous techniques in association with other diagnostic and management methods. METHODS: Thirty-six patients (28 male) were treated for postoperative bile leaks. A biliary leak was clinically suspected in case of persistent leakage of bilious material from a surgical drain, or in the presence of non-specific symptoms such as abdominal pain, fever and anorexia, with or without laboratory alteration of liver enzymes. Radiological confirmation was mainly based on noninvasive methods such as ultrasound, computed tomography, and magnetic resonance cholangiopancreatography. We assessed each treatment by evaluating multiple factors, including technical success (TS) and clinical effectiveness (CE), defined as primary or secondary. We also evaluated overall CE (OCE), defined as leak control with either single or multiple procedures. RESULTS: TS and OCE were achieved in all patients (36/36; 100%) with a grade A or B biliary leak. No grade C was observed. There were no major complications. Minor complications were observed in 7/36 (19.4%) patients. No procedure-related deaths occurred. CONCLUSIONS: In our study, considering all percutaneous techniques, leak healing was achieved in all the patients with a grade A or B biliary leak. These procedures provide a less invasive approach and are increasingly recognized as having a significant role in the management of complications and should be considered as an integral component in the postoperative management of these patients.

5.
Acta Biomed ; 91(10-S): e2020007, 2020 09 23.
Artigo em Inglês | MEDLINE | ID: mdl-33245074

RESUMO

Bone metastases are a common cause of cancer-related debilitating pain, especially when -localized in the vertebral column and not responsive to standard treatment. In such cases, various treatment options are available; among these is Radiofrequency, whose role has been rapidly growing over the past few years. In this study, we used the innovative Osteocool RF Ablation System (Medtronic) on a patient with a painful bone metastasis localized in the 5th lumbar vertebra, with encouraging results. The radiofrequency ablation of bone metastases with palliative aim represents an excellent treatment option, as it is a minimally invasive and safe procedure, and can be repeated multiple times.


Assuntos
Ablação por Radiofrequência , Neoplasias da Coluna Vertebral , Humanos , Dor , Cuidados Paliativos , Neoplasias da Coluna Vertebral/cirurgia , Tecnologia , Resultado do Tratamento
6.
Med Oncol ; 37(5): 41, 2020 Apr 07.
Artigo em Inglês | MEDLINE | ID: mdl-32266568

RESUMO

To retrospectively assess the predictive value of the CT performed at 24 h, compared with the CT performed at 1 month, in the evaluation of the technical success of microwave (MW) ablation of hepatic lesions. In a single center, 50 patients with HCC underwent percutaneous MW ablation between November 2016 and March 2019. Each patient underwent a contrast-enhanced CT exam at 24 h and at 1 month after the procedure. For each patient, was assessed the presence or absence of residual disease, the appearance of a new lesion, complications, and the involvement of the hepatic capsule, both at 24-h and at 1 month. Overall correlation between residual disease, appearance of a new nodule and complications was also assessed. A total of 50 hepatic lesions were treated with US-guided MW ablation. Patients' mean age was 70.9 years (range 28-87 years). Mean nodule diameter was 17.6 mm (range 7-35 mm). Contingency tables and the χ2 test showed a strong association when looking at capsule involvement (accuracy: 100%), residual disease (accuracy: 90%; p-value 0.003), and the appearance of a new HCC nodule (accuracy: 88%; p-value 0.007); regarding complications, the accuracy was 78% (p-value 0.014). Optimal correlation was reached in 62% of cases, moderate correlation in 26%, minimum correlation in 10% of cases; no cases of zero correlation were recorded. CT at 24 h and 1 month showed comparable efficacy in evaluating residual disease after MW thermal ablation of liver lesions. However, further studies are needed to assess which factors may cause false-negative results at the 24-h CT.


Assuntos
Carcinoma Hepatocelular/diagnóstico por imagem , Neoplasias Hepáticas/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Adulto , Idoso , Idoso de 80 Anos ou mais , Carcinoma Hepatocelular/patologia , Carcinoma Hepatocelular/cirurgia , Ablação por Cateter , Feminino , Seguimentos , Humanos , Fígado/diagnóstico por imagem , Fígado/patologia , Fígado/cirurgia , Neoplasias Hepáticas/patologia , Neoplasias Hepáticas/cirurgia , Masculino , Micro-Ondas/uso terapêutico , Pessoa de Meia-Idade , Neoplasia Residual , Estudos Retrospectivos , Cirurgia Assistida por Computador , Fatores de Tempo , Resultado do Tratamento , Ultrassonografia
7.
AJR Am J Roentgenol ; 214(2): 348-354, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31670584

RESUMO

OBJECTIVE. The purpose of this study was to evaluate the accuracy of CT colonography (CTC) in the diagnosis of synchronous colonic lesions in a cohort of patients with an occlusive colorectal cancer (CRC) causing incomplete colonoscopy. SUBJECTS AND METHODS. Among 109 patients with CRC causing incomplete colonoscopy who underwent CTC with IV contrast enhancement after cathartic purgation, fecal tagging, and colon distention, 70 (mean age, 70 years) for whom reference standards (surgical reports, first surveillance colonoscopy) were available were evaluated. Per-patient and per-lesion sensitivity, specificity, negative predictive value (NPV), and positive predictive value (PPV) of CTC in the diagnosis of synchronous colonic lesions measuring 6 mm or larger were assessed. RESULTS. Twenty-seven of the 70 patients (39%) had at least one 6-mm or larger synchronous lesion, and four patients (6%) had a total of five synchronous CRCs. Per-patient sensitivity in diagnosing synchronous CRC was 1.00 (4/4). There were 59 lesions: 20 with a diameter of 10 mm or greater; 30, 6-9 mm; and nine, 5 mm or less. The overall per-patient CTC sensitivity in detecting synchronous lesions 6 mm or larger was 0.93 (25/27); specificity, 0.98 (42/43); PPV, 0.96; and NPV, 0.95. Per-patient sensitivity for the diagnosis of synchronous advanced neoplasia (advanced adenoma and colorectal cancers) was 0.94 (15/16). Per-lesion CTC sensitivity for detecting synchronous lesions 6 mm or larger was 0.88 (37/42); all adenomatous lesions, 0.89 (55/62); and advanced neoplasia, 0.92 (22/24). CONCLUSION. CTC is a highly accurate test for detecting synchronous colonic lesions in patients with occlusive CRC. The prevalence of advanced neoplasia is high (23%).


Assuntos
Colonografia Tomográfica Computadorizada/métodos , Neoplasias Colorretais/diagnóstico por imagem , Neoplasias Primárias Múltiplas/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Colonoscopia , Neoplasias Colorretais/patologia , Meios de Contraste , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Neoplasias Primárias Múltiplas/patologia , Valor Preditivo dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...