Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Appl Radiat Isot ; 204: 111109, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38029636

RESUMO

The goal of this study is to provide a benchmark for the use of Monte Carlo simulation when applied to coincidence summing corrections. The examples are based on simple geometries: two types of germanium detectors and four kinds of sources, to mimic eight typical measurement conditions. The coincidence corrective factors are computed for four radionuclides. The exercise input files and calculation results with practical recommendations are made available for new users on a dedicated webpage.

2.
Appl Radiat Isot ; 155: 108921, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31629294

RESUMO

An internal consistency test of the calculation of coincidence-summing correction factors FC for volume sources is presented. The test is based on exact equations relating the values of FC calculated for three ideal measurement configurations. The test is applied to a number of 33 sets of FC values sent by 21 teams. Most sets passed the test, but not the results obtained using the quasi-point source approximation; in the latter case the test qualitatively indicated the magnitude of the bias of FC.

3.
Appl Radiat Isot ; 154: 108850, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31476556

RESUMO

Monte Carlo (MC) simulation is widely used in gamma-ray spectrometry, however, its implementation is not always easy and can provide erroneous results. The present action provides a benchmark for several MC software for selected cases. The examples are based on simple geometries, two types of germanium detectors and four kinds of sources, to mimic eight typical measurement conditions. The action outputs (input files and efficiency calculation results, including practical recommendations for new users) are made available on a dedicated webpage.

4.
Appl Radiat Isot ; 134: 466-469, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28712862

RESUMO

Natural radionuclides, such as short lived radon daughters and 7Be, have been analyzed in aerosols at the Nuclear Engineering Department of the National Technical University of Athens (NED-NTUA) since many years, with high accuracy and precision. During this research, an effort to detect 22Na and determine 7Be/22Na ratio in aerosols is presented. In order to study the role of precipitation in surface air 7Be and 22Na activity concentration, a procedure for collecting and analyzing rainwater was developed. With this technique 22Na was detected in air samples, although with relatively high uncertainties.

5.
Appl Radiat Isot ; 109: 563-565, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26671791

RESUMO

The purpose of this work was to investigate the effect of particle size on radionuclides in soil, particularly in relation to depth. A set of soil samples at the 0-10cm and 10-20cm depth layers were collected, separated into size fractions using a sieving machine and analyzed by gamma spectrometry to determine (238)U, (226)Ra, (210)Pb, and (137)Cs. Significant variations between different size fractions and depth layers were observed. A 0-20cm depth profile was also investigated.

6.
Appl Radiat Isot ; 87: 361-4, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24315283

RESUMO

This paper presents the Compton Suppression System, recently installed at the Nuclear Engineering Department of NTUA. The system consists of an XtRa Ge detector coupled with a NaI(Tl) guard detector. The electronic set-up allows for the simultaneous collection of both the suppressed and the unsuppressed spectra. System performance is investigated using certified point and volume sources. Parameters such as Peak Suppression Factors, peak-to-Compton ratios and minimum detectable activity for specific radionuclides are determined.

7.
Radiat Prot Dosimetry ; 156(4): 465-74, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23604742

RESUMO

The radionuclides released during the accident at the Fukushima Daichii nuclear power plant following the Tohoku earthquake and tsunami on 11 March 2011 were dispersed in the whole north hemisphere. Traces of (131)I, (134)Cs and (137)Cs reached Greece and were detected in air, grass, sheep milk, ground deposition, rainwater and drainage water. Members of Six Greek laboratories of the national network for environmental radioactivity monitoring have collaborated with the Greek Atomic Energy Commission (GAEC) and carried out measurements during the time period between 11 March 2011 and 10 May 2011 and reported their results to GAEC. These laboratories are sited in three Greek cities, Athens, Thessaloniki and Ioannina, covering a large part of the Greek territory. The concentrations of the radionuclides were studied as a function of time. The first indication for the arrival of the radionuclides in Greece originating from Fukushima accident took place on 24 March 2011. After 28 April 2011', concentrations of all the radionuclides were below the minimum detectable activities (<10 µBq m(-3) for (131)I). The range of concentration values in aerosol particles was 10-520 µBq m(-3) for (131)I, 10-200 µBq m(-3) for (134)Cs and 10-200 µBq m(-3) for (137)Cs and was 10-2200 µBq m(-3) for (131)I in gaseous phase. The ratios of (131)I/(137)Cs and (134)Cs/(137)Cs concentrations are also presented. For (131)I, the maximum concentration detected in grass was 2.2 Bq kg(-1). In the case of sheep milk, the maximum concentration detected for (131)I was 2 Bq l(-1). Furthermore, more than 200 samples of imported foodstuff have been measured in Greece, following the EC directives on the inspection of food and feeding stuffs.


Assuntos
Contaminação Radioativa de Alimentos/análise , Acidente Nuclear de Fukushima , Monitoramento de Radiação/métodos , Ar , Poluentes Radioativos do Ar/análise , Animais , Bovinos , Radioisótopos de Césio/análise , Exposição Ambiental/análise , Geografia , Grécia , Humanos , Radioisótopos do Iodo/análise , Leite , Controle de Qualidade , Doses de Radiação , Poluentes Radioativos/análise , Análise de Regressão , Ovinos , Espectrometria gama/métodos , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...