Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
1.
Minerva Cardioangiol ; 57(4): 367-87, 2009 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-19763064

RESUMO

Coronary artery disease remains the leading cause of death in adults in the United States. Non-invasive cardiac imaging is now central to the diagnosis and management of patients with known or suspected coronary disease. The generally accepted indications for stress testing include confirming a diagnosis of coronary disease, assessing prognosis, preoperative risk stratification, and evaluation of medical therapy. Stress echocardiography and single photon computed tomography are well-established non-invasive techniques for all the previously mentioned indications. These modalities provide a relatively high sensitivity and specificity along with an incremental value over clinical risk factors. Cardiac magnetic resonance imaging (CMRI) and multislice computed tomography are new imaging tools in the evaluation of patients with coronary disease. CMRI offers a comprehensive cardiac evaluation which includes wall motion analysis, myocardial tissue morphology, rest and stress first pass myocardial perfusion as well as systolic ventricular function. It is also considered a first line technique for the diagnosis of certain structural heart disease and chamber volume quantification. Cardiac computed tomography allows non-invasive anatomic imaging of the coronary tree. It has a high clinical utility especially in select intermediate risk patient population. Available tests all have advantages and drawbacks and none can be considered suitable for all patients. The choice of the imaging method should be tailored to each person based on the clinical judgment of the a priori risk of cardiac event, clinical history, and risk factors profile.


Assuntos
Doença das Coronárias/diagnóstico , Ecocardiografia sob Estresse , Síndrome Coronariana Aguda/diagnóstico , Adulto , Estudos de Coortes , Doença das Coronárias/diagnóstico por imagem , Ecocardiografia sob Estresse/métodos , Eletrocardiografia , Feminino , Humanos , Angiografia por Ressonância Magnética , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Prognóstico , Medição de Risco , Fatores de Risco , Sensibilidade e Especificidade , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Tomografia Computadorizada por Raios X/métodos
2.
Circulation ; 120(13): 1189-94, 2009 Sep 29.
Artigo em Inglês | MEDLINE | ID: mdl-19752326

RESUMO

BACKGROUND: Cardiac risk assessment for perioperative outcomes of liver transplantation patients is limited. We examined the outcomes of an older intermediate-cardiac-risk group of patients undergoing liver transplantation surgery. METHODS AND RESULTS: Patients who had liver transplantation surgery between 2001 and 2005 were studied. The 3 outcomes analyzed were nonfatal myocardial infarction, death, and either outcome within the first 30 days after the liver transplantation surgery. Of 403 patients (mean age, 52+/-9 years; 67% male), 106 (26%) were diabetic, 84 (21%) were hypertensive, and 173 (43%) had a history of smoking. There were 48 total events (12%), 25 myocardial infarctions (7%), and 38 deaths (9%) recorded during the perioperative period. From the final multivariate model, history of coronary artery disease, prior stroke, and postoperative sepsis predicted greater risk (P=0.014; odds ratio [OR], 4.0; 95% confidence interval [CI], 1.3 to 11.8; P=0.025; OR, 6.6; 95% CI, 1.3 to 33.8; and P<0.001; OR, 7.5; 95% CI, 3.3 to 17.1, respectively). Use of perioperative beta-blockers was protective (P=0.004; OR, 0.20; 95% CI, 0.1 to 0.6) for combined cardiac outcomes. For the outcome of death on multivariate analysis, postoperative sepsis and increased interventricular septal thickness predicted risk (P<0.001; OR, 8.6; 95% CI, 3.5 to 20.9; and P=0.027; OR, 2.8; 95% CI, 1.1 to 7.2, respectively), whereas the use of perioperative beta-blockers was again protective (P=0.012; OR, 0.07; 95% CI, 0.01 to 0.56). CONCLUSIONS: In our study of cardiac risk assessment for liver transplantation surgery, history of stroke, coronary artery disease, postoperative sepsis, and increased interventricular septal thickness were markers of adverse perioperative cardiac outcomes, whereas use of perioperative beta-blockers was significantly protective.


Assuntos
Transplante de Fígado/mortalidade , Infarto do Miocárdio/mortalidade , Complicações Pós-Operatórias/mortalidade , Antagonistas Adrenérgicos beta/uso terapêutico , Adulto , Diabetes Mellitus/mortalidade , Intervalo Livre de Doença , Teste de Esforço , Feminino , Humanos , Hipertensão/mortalidade , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Infarto do Miocárdio/tratamento farmacológico , Complicações Pós-Operatórias/tratamento farmacológico , Valor Preditivo dos Testes , Fatores de Risco , Sepse/mortalidade , Distribuição por Sexo , Fumar/mortalidade , Acidente Vascular Cerebral/mortalidade
3.
J Am Soc Echocardiogr ; 14(9): 917-20, 2001 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-11547278

RESUMO

Previous studies of intravenous contrast agents have excluded patients in the intensive care unit. These patients remain among the most technically difficult to image with ultrasound. We studied the effect of different imaging modalities with and without intravenous contrast (Optison) on endocardial border visualization during echocardiography. Fifty patients in the intensive care unit (32 men, 24 on mechanical ventilator, 10 with chest bandages; mean age, 59 years; mean weight, 91.7 kg; mean height, 67.6 inches) were considered to have technically difficult images when the endocardium could not be visualized in at least 2 of the 6 segments in either apical view. Each patient was studied with the use of fundamental (F), harmonic (H), fundamental + Optison (F + O), and H + O techniques, with standard long-axis, short-axis, and apical 4- and 2-chamber views. Intravenous Optison (0.5 to 1.5 mL) was given before F + O and H + O imaging. There were no contrast-related side effects noted. All images were stored digitally in a quad-screen format. For each set of images, segments (n = 22) were given an endocardial border visualization score of 0 if not visualized, 1 if visualized in either systole or diastole, and 2 if visualized in both. There was stepwise improvement in endocardial border visualization, with mean endocardial border visualization score of 1.09 +/- 0.83 (F), 1.33 +/- 0.81 (H), 1.64 +/- 0.62 (F + O), and 1.90 +/- 0.35 (H + O). There was a statistically significant difference between each group (P <.001). The incremental benefit of Optison was greater with harmonic imaging than with fundamental (P <.001). The use of Optison is safe and effective in the intensive care unit. In combination with harmonic imaging, contrast provides maximal endocardial border delineation during echocardiographic imaging of technically difficult patients in the intensive care unit.


Assuntos
Albuminas , Ecocardiografia/métodos , Endocárdio/diagnóstico por imagem , Fluorocarbonos , Albuminas/administração & dosagem , Meios de Contraste/administração & dosagem , Feminino , Fluorocarbonos/administração & dosagem , Humanos , Injeções Intravenosas , Unidades de Terapia Intensiva , Masculino , Microesferas , Pessoa de Meia-Idade , Ultrassom
4.
J Am Coll Cardiol ; 37(5): 1422-9, 2001 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-11300456

RESUMO

OBJECTIVES: We evaluated whether two-dimensional high-resolution transthoracic echocardiography (HR-2DTTE) can detect changes in arterial wall thickness and size associated with subclinical coronary artery disease (CAD). BACKGROUND: Arterial wall thickening, compensatory arterial enlargement and a preserved arterial lumen characterize subclinical atherosclerosis. Detection of these changes during the asymptomatic stage of CAD may allow early treatment and prevention of acute coronary events. METHODS: Twenty-six patients with angiographically proven CAD and 29 normal volunteers underwent HR-2DTTE evaluation of the left anterior descending coronary artery (LAD) using an ATL 5000 echograph (Advanced Technology Laboratories, Bothell, Washington) with a 4 to 7 MHz transducer. Significant (>70%) LAD stenosis was present in 15 patients (mean 82%); 11 patients did not have significant LAD stenosis (mean 26%) and represented a surrogate for subclinical LAD disease. Wall thickness, maximal luminal diameter and external diameter of the LAD were measured. RESULTS: Left anterior descending coronary artery wall thickness was larger in patients (1.9 +/- 0.4 mm) than it was in volunteers (0.9 +/- 0.1 mm, p < 0.001). The external diameter of the LAD was (6.0 +/- 1.1 mm) in patients and (3.9 +/- 0.7 mm) in volunteers (p < 0.001). Luminal diameter was 2.2 +/- 0.5 mm in patients and 2.1 +/- 0.6 mm in volunteers (p = NS). There was no difference in wall thickness (1.9 +/- 0.4 mm vs. 2.0 +/- 0.4 mm), luminal diameter (2.2 +/- 0.5 mm vs. 2.2 +/- 0.4 mm) and external diameter (5.9 +/- 1.0 mm vs. 6.2 +/- 1.2 mm) between the patients with <70% and >70% LAD stenosis. CONCLUSIONS: Left anterior descending coronary artery wall thickness and external diameter are significantly increased in patients with CAD as compared with normal subjects, and HR-2DTTE is sensitive enough to detect these differences. Wall thickness and external diameter are increased to the same extent in patients with obstructive and subclinical LAD disease.


Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Ecocardiografia , Aumento da Imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Vasos Coronários/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade
5.
J Am Soc Echocardiogr ; 14(2): 138-48, 2001 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-11174448

RESUMO

At low doses, dobutamine has potent inotropic, but limited chronotropic, effects-properties that may be necessary for detection of hibernating myocardium. The efficacy of other catecholamines, which have more closely coupled inotropic and chronotropic effects, for the detection of viable myocardium is unknown. This study evaluated the efficacy of arbutamine, a catecholamine with potent chrono-tropic effects, for the detection of viable myocardium in a canine model of hibernating myocardium. Contractile reserve was assessed during stepwise arbutamine infusion (dosages of 2.5, 5, 10, 50, and 100 ng/kg/min) at 3 days (early) and 4 weeks (late) after coronary ligation. Segment shortening, wall thickening, and segmental wall motion were assessed by sonomicrometry and echocardiography. After 4 weeks of occlusion, functional recovery was assessed after revascularization. During the early arbutamine study, the sensitivity for predicting functional recovery was highest at a dosage of 50 ng/kg/min, which also produced tachycardia. The sensitivity was 50% for segment shortening, 20% for wall thickening, and 75% for wall motion score. The late arbutamine study had improved sensitivity. The sensitivity was 100% for segment shortening, 80% for wall thickening, and 90% for wall motion score at a dosage of 50 ng/kg/min. At the late arbutamine study, myocardial perfusion reserve in the ischemic zone of dogs with functional recovery was only mildly reduced (2.0 versus 2.6 in nonischemic zones, P =.53). After coronary occlusion, viable myocardium can be detected with high doses of arbutamine that produce tachycardia. However, the sensitivity of arbutamine stimulation for predicting functional recovery is low early after occlusion, but it is improved by 4 weeks after occlusion with adequate perfusion reserve.


Assuntos
Cardiotônicos , Catecolaminas , Miocárdio Atordoado/diagnóstico , Animais , Doença Crônica , Modelos Animais de Doenças , Cães , Hemodinâmica , Contração Miocárdica/efeitos dos fármacos , Miocárdio Atordoado/diagnóstico por imagem , Fluxo Sanguíneo Regional , Sensibilidade e Especificidade , Ultrassonografia , Disfunção Ventricular Esquerda/diagnóstico
6.
J Am Soc Echocardiogr ; 12(9): 714-9, 1999 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-10477415

RESUMO

Conventional echocardiograms are typically recorded on videotape and later reviewed and interpreted by a physician. Although videotape recording is an excellent medium for this purpose, it does have several disadvantages, which may be overcome by digital storage. This study compared the diagnostic accuracy of digitized and videotape recorded echocardiograms. Echocardiographic examinations (n = 110) were recorded simulta-neously on videotape and were digitized with a commercially available frame grabber system. Images were transmitted by an Ethernet link to the network-based computer system and compressed with a nondestructive compression algorithm. Images were reviewed on a personal computer. Images were interpreted by 3 observers, and differences in interpretation were documented. There were 274 findings in 110 patients. Exact agreement in interpretation was found in 83%. A major discrepancy occurred in 2%, and a minor discrepancy occurred in 15%. Most discrepancies occurred in the setting of valvular heart disease. When compared with a consensus interpretation, no significant difference was seen in the number of errors between the digital and videotape interpretation. We conclude that the interpretation of a properly recorded digitized echocardiographic examination yields interpretations equivalent to those of videotape recordings.


Assuntos
Ecocardiografia , Interpretação de Imagem Assistida por Computador , Gravação de Videoteipe , Humanos , Variações Dependentes do Observador , Projetos Piloto , Estudos Prospectivos
7.
Circulation ; 100(2): 135-40, 1999 Jul 13.
Artigo em Inglês | MEDLINE | ID: mdl-10402442

RESUMO

BACKGROUND: Transmyocardial laser revascularization (TMR) has been shown to improve refractory angina not amenable to conventional coronary interventions. However, the mechanism of action remains controversial, because improved myocardial perfusion has not been consistently demonstrated. We hypothesized that TMR relieves angina by causing myocardial sympathetic denervation. METHODS AND RESULTS: PET imaging of resting and stress myocardial perfusion with [13N]ammonia (NH3) and of sympathetic innervation with [11C]hydroxyephedrine (HED) was performed before and after TMR in 8 patients with class IV angina ineligible for CABG or PTCA. A mean of 50+/-11 channels were created in the left ventricle (LV) with a holmium:YAG laser. A semiautomated program was used to determine NH3 uptake and HED retention in the LV. Perfusion and innervation defects were defined as the percentage of LV with tracer uptake or retention >2 SD below normal mean values. All patients experienced improvement in their angina by 2.4+/-0.5 angina classes after surgery, P=0.008. Sympathetic innervation defects exceeded resting perfusion defects in all patients before TMR (34.6+/-27.3% for HED versus 9.4+/-10.8% for NH3, P=0.008). TMR did not significantly affect resting or stress myocardial perfusion but increased the extent of sympathetic denervation in 6 of 8 patients by 27.5+/-15.9%, P=0.03. In the remaining 2 patients, both sympathetic denervation and stress perfusion defects decreased after surgery. CONCLUSIONS: TMR causes decreased myocardial HED uptake in most patients without significant change in resting or stress myocardial perfusion, suggesting that the improvement in angina may be at least in part due to sympathetic denervation.


Assuntos
Sistema de Condução Cardíaco/fisiopatologia , Terapia a Laser , Revascularização Miocárdica , Sistema Nervoso Simpático/fisiopatologia , Idoso , Angina Pectoris/diagnóstico por imagem , Angina Pectoris/fisiopatologia , Angina Pectoris/cirurgia , Circulação Coronária/fisiologia , Denervação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Resistência Física/fisiologia , Período Pós-Operatório , Tomografia Computadorizada de Emissão
8.
J Am Soc Echocardiogr ; 12(7): 559-63, 1999 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-10398914

RESUMO

The diagnostic value of echocardiography hinges on the reader's ability to adequately visualize the endocardium of the left ventricle. This study was designed to evaluate the potential benefit of noncontrast harmonic imaging to enhance endocardial visualization. Eighty consecutive outpatients who underwent treadmill stress echocardiography were randomly assigned to either fundamental or harmonic imaging. The echoes were interpreted by 2 experienced readers. Compared with fundamental imaging, harmonic imaging of tissue improved the overall endocardial visualization score by 35% and 21% for readers 1 and 2, respectively (P <.001). Harmonic imaging also reduced the percentage of nondiagnostic segments by one half (P <.01). In patients undergoing treadmill stress echo, harmonic imaging offers a clinically significant improvement in endocardial visualization.


Assuntos
Ecocardiografia/métodos , Cardiopatias/diagnóstico por imagem , Endocárdio/diagnóstico por imagem , Teste de Esforço , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Função Ventricular Esquerda
9.
Am J Cardiol ; 82(11): 1434-6, A9, 1998 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-9856935

RESUMO

The location of left anterior descending arterial stents was documented in 10 of 13 patients using 3-dimensionally acquired, 2-dimensionally displayed transthoracic echocardiography. The echocardiographic appearance of stents was characterized, and the location of the proximal and mid-left anterior descending artery was objectively documented.


Assuntos
Doença das Coronárias/diagnóstico por imagem , Ecocardiografia Doppler , Ecocardiografia Tridimensional , Stents , Adulto , Idoso , Ecocardiografia Transesofagiana , Humanos , Pessoa de Meia-Idade
10.
J Am Soc Echocardiogr ; 11(10): 989-91, 1998 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-9804107

RESUMO

Power motion imaging allows interrogation of low-velocity tissue. By means of power motion imaging with 2 different late-model echographs we identified an intra-atrial tumor that was undetectable on conventional transthoracic echocardiograms.


Assuntos
Neoplasias Cardíacas/diagnóstico por imagem , Linfoma Difuso de Grandes Células B/diagnóstico por imagem , Idoso , Ecocardiografia Transesofagiana , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Estudos Retrospectivos
11.
Am Heart J ; 135(2 Pt 1): 253-60, 1998 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-9489973

RESUMO

We investigated the clinical utility of cardiac troponin T (TnT) and echocardiography in the emergency department to predict subsequent in-hospital diagnosis and adverse cardiac events. TnT is a cardiac-specific protein released during cell injury such as that following acute myocardial inFarction (MI). Unlike creatine kinase-MB isoenzymes, TnT is increased in a subset of patients with unstable angina, and these may be at higher risk for subsequent cardiac events. Echocardiography is a useful noninvasive imaging technique for the assessment of ischemic heart disease in acute care settings because of its mobility and rapid results. Serial TnT determinations and echocardiographic images were prospectively evaluated in 100 patients with chest discomfort and admitted to the hospital. Serum was obtained for CKMB and TnT on presentation to the emergency department and 4, 8, 16 and 24 hours later. TnT was considered increased when at values greater than 0.1 microg/L. Echocardiograms were recorded on videotape in the emergency department and images reviewed in a blinded fashion for wall-motion abnormalities. When available, current echocardiographic results were compared with previous results to determine whether a new wall-motion abnormality was present. Of the 100 patients (57 men, 43 women), TnT was increased in 21 of 21 with acute MI and 15 of 41 with unstable angina. One of the 38 patients with stable angina had an increased TnT value and died 5 months later of a noncardiac cause. Ninety percent of patients who sustained acute MI had a TnT increase detected within 4 hours of presentation. Fifteen of 18 patients with acute MI and 9 of 37 patients with unstable angina had a new wall-motion abnormality on echocardiography. The combination of TnT levels with echocardiography yielded a positive predictive value of 84% and a negative predictive value of 90% for adverse cardiac events in the follow-up population, which was more accurate than either test analyzed separately. TnT and echocardiography are useful tests in emergency department triage of unstable coronary syndromes. Both tests are predictive of discharge diagnosis and follow-up events. However, the combined utility of TnT levels and echocardiographic imaging is a more powerful predictor of adverse cardiac events than isolated results.


Assuntos
Angina Instável/diagnóstico , Ecocardiografia , Infarto do Miocárdio/diagnóstico , Troponina/sangue , Angina Instável/epidemiologia , Biomarcadores/sangue , Creatina Quinase/sangue , Eletrocardiografia , Serviço Hospitalar de Emergência , Feminino , Humanos , Isoenzimas , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/epidemiologia , Valor Preditivo dos Testes , Estudos Prospectivos , Fatores de Tempo , Triagem , Troponina T , Gravação de Videoteipe
12.
J Am Soc Echocardiogr ; 9(4): 501-7, 1996.
Artigo em Inglês | MEDLINE | ID: mdl-8827633

RESUMO

We prospectively compared digital echocardiographic images, by a minimal digital-acquisition strategy, with videotape images to determine the diagnostic utility of digital imaging in patients admitted to the emergency department with chest pain. Digital acquisition has many potential advantages for evaluating echocardiographic images, especially in the acute-care setting. It is not yet known how much the imaging study can be condensed with digital technology and still provide the necessary information needed for clinical echocardiographic diagnosis. One hundred seventeen patients with diagnoses consisting of coronary artery disease, pericardial disease, and valvular disease were studied. Overall agreement between videotape and digital recordings with regard to normal versus abnormal wall motion was 94% (p < 0.001). The wall motion score index, a semiquantitative measure of global function, also correlated well (r = 0.94). Complete concordance was noted in all patients with aortic stenosis and pericardial effusion. Digital echocardiographic imaging, by a minimal-acquisition strategy, is an accurate summary of the complete echocardiographic examination and provides the relevant diagnostic data needed for the assessment of patients with chest pain in the emergency department.


Assuntos
Dor no Peito/diagnóstico por imagem , Ecocardiografia/métodos , Processamento de Imagem Assistida por Computador , Processamento de Sinais Assistido por Computador , Gravação de Videoteipe , Serviço Hospitalar de Emergência , Feminino , Cardiopatias/diagnóstico por imagem , Doenças das Valvas Cardíacas/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Pericárdio
13.
Am J Cardiol ; 77(2): 175-9, 1996 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-8546087

RESUMO

The purpose of this study was to examine the ability of dobutamine stress echocardiography to stratify patients with juvenile onset, insulin-dependent diabetes mellitus who are being considered for kidney and/or pancreas transplantation, into high-or low-risk groups for future cardiac events. Fifty-three such patients underwent dobutamine stress echocardiography before kidney and/or pancreas transplantation. Cardiac events, including cardiac death, nonfatal myocardial infarction, unstable angina, pulmonary edema, and need for coronary revascularization, occurring between the time of the dobutamine stress echocardiogram and the last patient follow-up contact were retrospectively identified. Twenty patients 938%) had an abnormal dobutamine stress echocardiogram. Eleven patients had 15 cardiac events over a mean (+/- SD) follow-up period of 418 +/- 269 days. Event rates were 45% among those with an abnormal, versus 6% among those with a normal dobutamine stress echocardiogram (p = 0.002). The result of the dobutamine stress test independently predicted prognosis in a multivariate analysis (p = 0.003, odds ratio = 12.7). We conclude that dobutamine stress echocardiography accurately stratifies patients with juvenile onset, insulin-dependent diabetes being considered for kidney and/or pancreas transplantation for risk of future cardiac events.


Assuntos
Diabetes Mellitus Tipo 1/diagnóstico por imagem , Dobutamina , Ecocardiografia , Cardiopatias/diagnóstico por imagem , Transplante de Rim , Transplante de Pâncreas , Adulto , Fatores de Confusão Epidemiológicos , Angiografia Coronária , Ecocardiografia/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Valor Preditivo dos Testes , Risco
14.
J Am Coll Cardiol ; 26(5): 1348-55, 1995 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-7594053

RESUMO

OBJECTIVES: The purpose of this study was to 1) develop an animal model of hibernating myocardium, and 2) evaluate the ability of dobutamine stimulation to detect hibernating myocardium using both qualitative and quantitative assessment of regional myocardial function. BACKGROUND: Left ventricular dysfunction may be due to chronic ischemia with or without myocardial infarction and may improve after coronary blood flow is enhanced by revascularization procedures. This condition has been coined "hibernating myocardium" and variably defined in recent years. The results of recent clinical studies suggest that dobutamine echocardiography may be useful for detecting viable myocardium in patients with left ventricular dysfunction. METHODS: Twenty-one dogs underwent initial operation. Sonomicrometer crystals were implanted, and baseline measurements of segment shortening and wall thickening (by echocardiography) were made. A coronary artery was ligated; the chest was closed; and measurements were repeated. Dobutamine was incrementally infused with determination of wall thickening and segment shortening at baseline and on days 3 and 7 and weeks 2 and 4 after coronary artery occlusion. Finally, the chest was reopened; the ligated vessel was bypassed; and measurements were repeated. RESULTS: Of the 10 dogs that completed the entire protocol, 7 had varying degrees of nontransmural myocardial infarction (group 1), and 3 had complete transmural myocardial infarction (group 2). In group 1, baseline function was significantly impaired compared with preligation function but increased during dobutamine infusion. When reperfused after 4 weeks, both wall thickening and segment shortening increased significantly. In group 2, significant changes were not seen during the dobutamine studies or after reperfusion. Myocardial perfusion during dobutamine infusion increased in group 1 but did not change in group 2. CONCLUSIONS: We demonstrated improvement in chronically dysfunctional myocardium after restoration of previously interrupted myocardial blood flow in dogs after nontransmural myocardial infarction, thus validating a canine model of hibernating myocardium. As assessed by two independent methods, dobutamine infusion identified hibernating myocardium in an animal model.


Assuntos
Dobutamina , Isquemia Miocárdica/diagnóstico , Animais , Modelos Animais de Doenças , Dobutamina/administração & dosagem , Cães , Ecocardiografia , Função Ventricular Esquerda
15.
J Am Soc Echocardiogr ; 8(1): 9-14, 1995.
Artigo em Inglês | MEDLINE | ID: mdl-7710756

RESUMO

The purpose of our study was to compare the ability of dobutamine and dipyridamole infusion to induce myocardial ischemia. In a population of 16 anesthetized open-chest swine, a coronary artery stenosis sufficient to abolish the hyperemic response to a 15-second total occlusion was created. Heart rate, systolic blood pressure, and dP/dt were recorded. Myocardial segment shortening was determined by sonomicrometry in all animals. In a subset of seven animals regional myocardial blood flow was measured by injection of radiolabeled microspheres. Dipyridamole was infused according to a high-dose protocol. After a washout period and reestablishment of a baseline state, dobutamine was infused incrementally. There was no significant difference between the baseline states. Dipyridamole did not affect heart rate but did significantly decrease blood pressure and rate-pressure product. Myocardial segment shortening decreased in the ischemic zone by 0.07 +/- 0.08 (p = 0.004). Dobutamine infusion significantly increased heart rate, blood pressure, and rate-pressure product. Myocardial segment shortening in the ischemic zone decreased by 0.17 +/- 0.09 (p < 0.001). Dobutamine decreased blood flow in the ischemic zone relative to baseline. Both dobutamine and dipyridamole infusion resulted in myocardial ischemia. The magnitude of the ischemic response is greater for dobutamine than for dipyridamole.


Assuntos
Dipiridamol/efeitos adversos , Dobutamina/efeitos adversos , Isquemia Miocárdica/induzido quimicamente , Animais , Pressão Sanguínea/efeitos dos fármacos , Constrição , Circulação Coronária/efeitos dos fármacos , Vasos Coronários , Feminino , Frequência Cardíaca/efeitos dos fármacos , Masculino , Contração Miocárdica/efeitos dos fármacos , Isquemia Miocárdica/fisiopatologia , Suínos , Disfunção Ventricular Esquerda/induzido quimicamente , Disfunção Ventricular Esquerda/fisiopatologia
16.
J Am Coll Cardiol ; 24(4): 934-9, 1994 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-7930227

RESUMO

OBJECTIVES: This study attempted to determine the safety and accuracy of dobutamine stress echocardiography for detection of coronary artery disease in patients with dilated cardiomyopathy. BACKGROUND: Detection of regional wall motion abnormalities at rest does not reliably distinguish ischemic from nonischemic cardiomyopathy. Previous studies have shown that dobutamine stress echocardiography safely and accurately identifies coronary artery disease in patients without dilated cardiomyopathy. METHODS: Seventy patients with dilated cardiomyopathy underwent dobutamine stress echocardiography. Echocardiograms were obtained at baseline and at low (5 to 10 micrograms/kg body weight per min) and peak doses of dobutamine. Rest and stress left ventricular wall motion scores were derived from analysis of regional wall motion. Fifty-four subjects underwent coronary angiography. RESULTS: Dobutamine infusion was terminated after achievement of the target heart rate or maximal protocol dose in 49 patients (70%), ischemia in 12 (17%), arrhythmia in 4 (6%) and side effects in 5 (7%). No patient had prolonged ischemia or sustained arrhythmia. Of those with angiographic studies, 40 had significant coronary artery disease (> or = 50% diameter stenosis). Use of the change in global wall motion score index from low to peak dose resulted in a sensitivity of 83% for dobutamine stress echocardiography and a specificity of 71% for detection of coronary artery disease. Sensitivity for detection of triple-, double- and single-vessel disease was 100%, 83% and 69%, respectively. CONCLUSIONS: Dobutamine stress echocardiography safely provides diagnostic information in patients with dilated cardiomyopathy. This technique has high sensitivity for multivessel coronary artery disease but only moderate specificity.


Assuntos
Cardiomiopatia Dilatada/complicações , Doença das Coronárias/diagnóstico por imagem , Dobutamina , Ecocardiografia , Adulto , Idoso , Cardiomiopatia Dilatada/fisiopatologia , Constrição Patológica/complicações , Constrição Patológica/diagnóstico por imagem , Angiografia Coronária , Doença das Coronárias/complicações , Eletrocardiografia , Teste de Esforço , Feminino , Hemodinâmica , Humanos , Masculino , Pessoa de Meia-Idade , Contração Miocárdica , Valor Preditivo dos Testes , Sensibilidade e Especificidade , Função Ventricular Esquerda
17.
J Am Soc Echocardiogr ; 7(4): 363-9, 1994.
Artigo em Inglês | MEDLINE | ID: mdl-7917344

RESUMO

Color coding is a new software application for digitized echocardiograms that displays a reference image of end diastole throughout the cardiac cycle. With color-coded digitized echocardiograms, we determined the frequency of, and corrected for cardiac translation in 21 bicycle stress echocardiograms in patients who were known to be without significant coronary artery disease or wall motion abnormalities. Translation was present in 4%, 40%, and 74% of rest, postexercise, and peak exercise images, respectively, and was noted most frequently in the apical views, 59% of four-chamber views and 40% of two-chamber views. Interobserver and intraobserver agreement for detection of translation was 81% and 86%, respectively. Translation was corrected by shifting digitized images to eliminate transverse displacement of the mitral valve anulus and restore normal basal-to-apical shortening. Ventricular contraction was assessed as normal in 92% of the images in which correction for translation was performed. In the remaining images, poor image quality (3%) and apparent wall motion abnormalities (5%) prevented the studies from being graded as normal. We conclude that color coding of digitized echocardiograms is a useful new technique that can be applied to detect and correct for cardiac translation.


Assuntos
Apresentação de Dados , Ecocardiografia , Coração/anatomia & histologia , Processamento de Imagem Assistida por Computador , Processamento de Sinais Assistido por Computador , Diástole , Teste de Esforço , Feminino , Septos Cardíacos/diagnóstico por imagem , Ventrículos do Coração/diagnóstico por imagem , Humanos , Processamento de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Valva Mitral/diagnóstico por imagem , Contração Miocárdica , Sístole
18.
J Am Coll Cardiol ; 23(1): 92-8, 1994 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-8277101

RESUMO

OBJECTIVES: The purpose of this study was to determine the relative value of single-photon emission computed tomographic (SPECT) imaging at rest using technetium-99m methoxyisobutyl isonitrile (technetium-99m sestamibi) with positron emission tomography for detection of viable myocardium. BACKGROUND: Recent studies comparing positron emission tomography and thallium-201 reinjection with rest technetium-99m sestamibi imaging have suggested that the latter technique underestimates myocardial viability. METHODS: Twenty patients with a previous myocardial infarction underwent rest technetium-99m sestamibi imaging and positron emission tomography using fluorine (F)-18 deoxyglucose and nitrogen (N)-13 ammonia. In each patient, circumferential profile analysis was used to determine technetium-99m sestamibi, F-18 deoxyglucose and N-13 ammonia activity (expressed as percent of peak activity) in nine cardiac segments and in the perfusion defect defined by the area having technetium-99m sestamibi activity < 60%. Technetium-99m sestamibi defects were graded as moderate (50% to 59% of peak activity) and severe (< 50% of peak activity). Estimates of perfusion defect size were compared between technetium-99m sestamibi and N-13 ammonia. RESULTS: Sixteen (53%) of 30 segments with moderate defects and 16 (47%) of 34 segments with severe defects had > or = 60% F-18 deoxyglucose activity considered indicative of viability. Fluorine-18 deoxyglucose evidence of viability was still present in 50% of segments with technetium-99m sestamibi activity < 40%. There was no significant difference in the mean (+/- SD) technetium-99m sestamibi activity in segments with viable (40 +/- 7%) and nonviable segments (49 +/- 7%, p = 0.84). Of the 18 patients who had adequate F-18 deoxyglucose studies, the area of the technetium-99m sestamibi defect was viable in 5 (28%). In 16 patients (80%), perfusion defect size determined by technetium-99m sestamibi exceeded that measured by N-13 ammonia. The difference in defect size between technetium-99m sestamibi and N-13 ammonia was significantly greater in patients with viable (21 +/- 9%) versus nonviable segments (7 +/- 9%, p = 0.007). CONCLUSIONS: Moderate and severe rest technetium-99m sestamibi defects frequently have metabolic evidence of viability. Technetium-99m sestamibi SPECT yields larger perfusion defects than does N-13 ammonia positron emission tomography when the same threshold values are used.


Assuntos
Coração/diagnóstico por imagem , Infarto do Miocárdio/diagnóstico por imagem , Tecnécio Tc 99m Sestamibi , Tomografia Computadorizada de Emissão de Fóton Único , Adulto , Idoso , Sobrevivência Celular , Feminino , Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/patologia , Infarto do Miocárdio/fisiopatologia , Miocárdio/patologia , Valor Preditivo dos Testes , Tomografia Computadorizada de Emissão
19.
Circulation ; 88(1): 15-9, 1993 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-8319327

RESUMO

BACKGROUND: The use of dobutamine stress echocardiography for the evaluation of coronary artery disease is rapidly expanding. New applications of the technique are being investigated in a wide variety of patients including those with advanced coronary artery disease. Despite its widespread use, the safety of dobutamine stress echocardiography has not been sufficiently documented. METHODS AND RESULTS: A consecutive series of 1118 patients undergoing dobutamine stress echocardiography for evaluation of known or suspected coronary artery disease form the basis of this report. Dobutamine stress testing was performed for evaluation of chest pain, risk assessment before noncardiac surgery, after recent myocardial infarction, or as a part of ongoing research protocols. Over the study period, the maximal dose of dobutamine used was increased from 30 to 50 micrograms/kg per minute, and atropine was used in 420 (37%) patients. There were no occurrences of death, myocardial infarction, or episodes of sustained ventricular tachycardia as a result of dobutamine stress testing. The major reasons for test termination were achievement of target heart rate in 583 patients (52.1%), maximum dose in 255 (22.8%), and angina pectoris in 142 (13%). The test was terminated in 36 (3%) patients because of noncardiac side effects including nausea, anxiety, headache, tremor, and urgency. Angina pectoris occurred in 216 (19.3%) patients. Sublingual nitroglycerin, a short-acting beta-blocker, or both types of medication were administered in 80 of these patients for relief of angina pectoris. None required intravenous nitroglycerin. A total of 736 (65%) patients had stable sinus rhythm throughout the test. The most common arrhythmias were frequent premature ventricular complexes (six or more per minute) in 172 patients (15%), and frequent premature atrial complexes in 86 (8%). There were 40 patients with nonsustained ventricular tachycardia. None had symptoms associated with the tachycardia, and only one received specific pharmacological treatment to prevent recurrence of the arrhythmia after the test was terminated. The patients who were evaluated after recent myocardial infarction and those who received atropine did not have a higher frequency of ventricular tachycardia compared with those without recent infarction and those not receiving atropine. CONCLUSIONS: Dobutamine stress echocardiography was safely performed using supplemental atropine and an aggressive dosing protocol. Noncardiac side effects were usually minor. Arrhythmias were well tolerated and rarely required treatment. In this study, serious complications from myocardial ischemia did not occur. Symptomatic ischemia was effectively treated with test termination, sublingual nitroglycerin, or short-acting beta-blockers.


Assuntos
Doença das Coronárias/diagnóstico por imagem , Dobutamina/efeitos adversos , Ecocardiografia/métodos , Angina Pectoris/induzido quimicamente , Arritmias Cardíacas/induzido quimicamente , Atropina , Teste de Esforço/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Taquicardia Ventricular/induzido quimicamente
20.
J Am Soc Echocardiogr ; 6(2): 186-97, 1993.
Artigo em Inglês | MEDLINE | ID: mdl-8481247

RESUMO

This study examined the advantages and limitations of upright bicycle exercise echocardiography in the evaluation of a large series of patients with known or suspected coronary artery disease. The study population consisted of 309 patients (231 men, mean age 57 +/- 11 years) who underwent exercise echocardiography within 8.5 +/- 16.1 days of coronary angiography. All stress electrocardiographic, echocardiographic, and angiographic data were reinterpreted in a blinded manner by the investigators. No patient was excluded because of poor echocardiographic image quality. Wall motion was analyzed at baseline, peak exercise, and immediately after exercise with a 16-segment model, and a regional wall motion score index was calculated at each stage. Abnormalities were ascribed to the distribution of the three coronary arteries and correlated with qualitative angiography. There were 126 patients with wall motion abnormalities at rest and 211 (75%) with coronary artery disease. The stress electrocardiogram (ECG) was negative in 61, positive in 144, and nondiagnostic in 104, yielding a sensitivity of 40% and a specificity of 89%. Echocardiography was normal in 76 of 98 patients without coronary disease (78% specificity) and abnormal in 193 of 211 patients with disease (91% sensitivity). Sensitivity was higher among patients with multivessel disease compared with those with single vessel disease (95% versus 86%, respectively, p = 0.03). Among patients with normal wall motion at rest (n = 183), sensitivity was 83% and specificity was 84%. Of the 104 patients with a nondiagnostic stress ECG, echocardiography correctly identified 95% of those with coronary disease and 75% of those without disease. Among 82 patients with a wall motion abnormality at rest, an additional exercise-induced wall motion abnormality developed in 32 of 46 patients (70%) with multivessel disease and seven of 32 (22%) with single-vessel disease. Overall, echocardiography detected 258 of 392 (66%) individual coronary lesions. Accuracy was higher for lesions in the left anterior descending and right coronary arteries (both 79%) compared with the left circumflex artery (36%, p < 0.001). In conclusion, upright bicycle exercise echocardiography is an accurate technique for the evaluation of patients with known or suspected coronary artery disease and is especially valuable in patients with a nondiagnostic stress ECG. The test provides supplemental information on the extent and location of coronary lesions and is useful in patients with and without prior myocardial infarction.


Assuntos
Doença das Coronárias/diagnóstico por imagem , Ecocardiografia , Teste de Esforço , Angiografia Coronária , Doença das Coronárias/diagnóstico , Eletrocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...