Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Drug Deliv Transl Res ; 12(2): 368-375, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34655041

RESUMO

Microneedle array patch (MAP) technology is a promising new delivery technology for vaccines and pharmaceuticals, yet due to several differing and novel production methods, barriers to full-scale manufacturing exist. PATH conducted a manufacturing readiness assessment and follow-up interviews to identify both the current manufacturing readiness of the industry as well as how readiness varies by developer type and MAP type. Follow-up interviews identified barriers the industry faces in reaching full manufacturing readiness, including the perceived regulatory and investment risk of manufacturing MAPs at scale due to quality requirements and control methods, uncertain sterility requirements, lack of standard production methods (especially around dissolvable MAP drying methods), and the lack of available contract manufacturing organizations with MAP manufacturing capabilities. A Regulatory Working Group has been established to identify and address critical quality issues specific to MAP manufacturing with the aim of providing developers insight into what will be expected for MAP product approvals. Standardizing MAP production equipment and automatic, visual quality control could reduce the overall investment risk to developers and contract manufacturing organizations in pursuing pilot-scale manufacturing capabilities and ultimately lower barriers to the scale-up of full medical MAP product lines.


Assuntos
Sistemas de Liberação de Medicamentos , Vacinas , Comércio , Preparações Farmacêuticas , Controle de Qualidade
2.
Vaccine ; 35(14): 1789-1796, 2017 03 27.
Artigo em Inglês | MEDLINE | ID: mdl-28189403

RESUMO

INTRODUCTION: Intradermal delivery of a fractional dose of inactivated poliovirus vaccine (IPV) offers potential benefits compared to intramuscular (IM) delivery, including possible cost reductions and easing of IPV supply shortages. Objectives of this study were to assess intradermal delivery devices for dead space, wastage generated by the filling process, dose accuracy, and total number of doses that can be delivered per vial. METHODS: Devices tested included syringes with staked (fixed) needles (autodisable syringes and syringes used with intradermal adapters), a luer-slip needle and syringe, a mini-needle syringe, a hollow microneedle device, and disposable-syringe jet injectors with their associated filling adapters. Each device was used to withdraw 0.1-mL fractional doses from single-dose IM glass vials which were then ejected into a beaker. Both vial and device were weighed before and after filling and again after expulsion of liquid to record change in volume at each stage of the process. Data were used to calculate the number of doses that could potentially be obtained from multidose vials. RESULTS: Results show wide variability in dead space, dose accuracy, overall wastage, and total number of doses that can be obtained per vial among intradermal delivery devices. Syringes with staked needles had relatively low dead space and low overall wastage, and could achieve a greater number of doses per vial compared to syringes with a detachable luer-slip needle. Of the disposable-syringe jet injectors tested, one was comparable to syringes with staked needles. DISCUSSION: If intradermal delivery of IPV is introduced, selection of an intradermal delivery device can have a substantial impact on vaccine wasted during administration, and thus on the required quantity of vaccine that needs to be purchased. An ideal intradermal delivery device should be not only safe, reliable, accurate, and acceptable to users and vaccine recipients, but should also have low dead space, high dose accuracy, and low overall wastage to maximize the potential number of doses that can be withdrawn and delivered.


Assuntos
Vacina Antipólio de Vírus Inativado/administração & dosagem , Vacinação/instrumentação , Vacinação/métodos , Humanos , Injeções Intradérmicas/instrumentação , Injeções Intradérmicas/métodos , Agulhas , Poliomielite/prevenção & controle , Poliovirus/imunologia , Seringas
3.
Vaccine ; 33(36): 4540-7, 2015 Aug 26.
Artigo em Inglês | MEDLINE | ID: mdl-26192359

RESUMO

Disposable-syringe jet injectors (DSJIs) with single-use, auto disable, needle-free syringes offer the opportunity to avoid hazards associated with injection using a needle and syringe. Clinical studies have evaluated DSJIs for vaccine delivery, but most studies have focused on inactivated, subunit, or DNA vaccines. Questions have been raised about possible damage to live attenuated viral vaccines by forces generated during the jet injection process. This study examines the effect of jet injection on the integrity of measles, mumps, and rubella vaccine (MMR), measured by viral RNA content and infectivity. Three models of DSJIs were evaluated, each generating a different ejection force. Following jet injection, the RNA content for each of the vaccine components was measured using RT-qPCR immediately after injection and following passage in Vero cells. Jet injection was performed with and without pig skin as a simulation of human skin. There was little to no reduction of RNA content immediately following jet injection with any of the three DSJIs. Samples passaged in Vero cells showed no loss in infectivity of the measles vaccine following jet injection. Mumps vaccine consistently showed increased replication following jet injection. Rubella vaccine showed no loss after jet injection alone but some infectivity loss following injection through pig skin with two of the devices. Overall, these data demonstrated that forces exerted on a live attenuated MMR vaccine did not compromise vaccine infectivity. The bench model and protocol used in this study can be applied to evaluate the impact of jet injection on other live virus vaccines.


Assuntos
Equipamentos Descartáveis , Injeções a Jato/métodos , Vacina contra Sarampo-Caxumba-Rubéola/química , Vacina contra Sarampo-Caxumba-Rubéola/imunologia , Animais , Chlorocebus aethiops , Vírus do Sarampo/crescimento & desenvolvimento , Viabilidade Microbiana , Vírus da Caxumba/crescimento & desenvolvimento , RNA Viral/análise , Reação em Cadeia da Polimerase em Tempo Real , Reação em Cadeia da Polimerase Via Transcriptase Reversa , Vírus da Rubéola/crescimento & desenvolvimento , Células Vero , Cultura de Vírus
4.
Contraception ; 88(1): 58-66, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23177261

RESUMO

BACKGROUND: There is considerable interest in developing new multipurpose prevention technologies to address women's reproductive health needs. This study describes an innovative barrier contraceptive device--based on the SILCS diaphragm--that also provides long-term controlled release of the lead candidate anti-HIV microbicide dapivirine. STUDY DESIGN: Diaphragm devices comprising various dapivirine-loaded polymer spring cores overmolded with a nonmedicated silicone elastomer sheath were fabricated by injection molding processes. In vitro release testing, thermal analysis and mechanical characterization were performed on the devices. RESULTS: A diaphragm device containing a polyoxymethylene spring core loaded with 10% w/w dapivirine provided continuous and controlled release of dapivirine over a 6-month period, with a mean in vitro daily release rate of 174 mcg/day. The mechanical properties of the new diaphragm were closely matched to the SILCS diaphragm. CONCLUSIONS: The study demonstrates proof of concept for a dapivirine-releasing diaphragm with daily release quantities potentially capable of preventing HIV transmission. In discontinuous clinical use, release of dapivirine may be readily extended over 1 or more years.


Assuntos
Fármacos Anti-HIV/química , Dispositivos Anticoncepcionais Femininos , Transcriptase Reversa do HIV/química , Pirimidinas/química , Fármacos Anti-HIV/administração & dosagem , Fármacos Anti-HIV/uso terapêutico , Varredura Diferencial de Calorimetria , Fenômenos Químicos , Temperatura Baixa/efeitos adversos , Preparações de Ação Retardada/administração & dosagem , Preparações de Ação Retardada/química , Preparações de Ação Retardada/uso terapêutico , Feminino , Infecções por HIV/prevenção & controle , Infecções por HIV/transmissão , Transcriptase Reversa do HIV/administração & dosagem , Transcriptase Reversa do HIV/uso terapêutico , Temperatura Alta/efeitos adversos , Humanos , Cinética , Teste de Materiais , Fenômenos Mecânicos , Pirimidinas/administração & dosagem , Pirimidinas/uso terapêutico , Solubilidade
5.
Artigo em Inglês | MEDLINE | ID: mdl-21096558

RESUMO

Contraceptive diaphragms offer a discreet method of pregnancy protection that women can use when needed with no side effects. Incorporating antiretroviral HIV microbicides into such devices may also provide protection against HIV infection. The paper gives a brief outline of the work being conducted by PATH, CONRAD and QUB on the development of a microbicide-releasing SILCS diaphragm. The design, engineering and manufacturing challenges that have been encountered will be discussed, as well as the potential impact such a device could have in the developing world.


Assuntos
Fármacos Anti-HIV/administração & dosagem , Anti-Infecciosos Locais/administração & dosagem , Dispositivos Anticoncepcionais Femininos , Implantes de Medicamento/administração & dosagem , Infecções por HIV/prevenção & controle , Fármacos Anti-HIV/química , Anti-Infecciosos Locais/química , Implantes de Medicamento/química , Desenho de Equipamento , Análise de Falha de Equipamento , Feminino , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...