Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sci Rep ; 8(1): 4659, 2018 03 15.
Artigo em Inglês | MEDLINE | ID: mdl-29545518

RESUMO

This study develops a method to determine toricity ratios used by arbitrary toric intraocular lens calculators. Access to this information allows for the improvement of refractive results. We derive the Sayegh-Gabra formula, which uses input and output parameters in a toric calculator to extract toricity ratios that are typically not disclosed. We illustrate the method on a number of commercial calculators. For each calculator, high, average, and low axial length values are crossed with high, average, and low mean corneal power values to generate a 3 × 3 matrix. A toricity ratio is generated for each axial length and mean corneal power pair. We thus identify several toric lens manufacturers' calculators that use a constant toricity ratio, often 1.46. Some others use a variable ratio centered at 1.46, but varying as axial length and mean K increases over a range of values corresponding to physiological myopia and hyperopia. There is an emerging trend away from constant toricity ratios. Using our methodology, it is possible to extract the toricity ratio used by specific calculators/manufacturers, distinguish those using constant versus variable toricity ratios, and use this information to improve surgical outcomes by refining current and future toric intraocular lens calculators.

2.
Transl Vis Sci Technol ; 3(3): 10, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25068092

RESUMO

PURPOSE: The goal of this study was to evaluate the ability of our handheld optical coherence tomography (OCT) scanner to image the posterior and anterior structures of the human eye, and especially the individual layers of the retina, and to compare its diagnostic performance with that of a fixed desktop commercial ophthalmic OCT system. METHODS: We compared the clinical imaging results of our handheld OCT with a leading commercial desktop ophthalmic system (RTVue) used in specialist offices. Six patients exhibiting diabetes-related retinal pathology had both eyes imaged with each OCT system. RESULTS: In both sets of images, the structural irregularities of the retinal layers could be identified such as retinal edema and vitreomacular traction. CONCLUSIONS: Our handheld OCT system can be used to identify relevant anatomical structures and pathologies in the eye, potentially enabling earlier screening, disease detection, and treatment. Images can be acquired quickly, with sufficient resolution and negligible motion artifacts that would normally limit its diagnostic use. TRANSLATIONAL RELEVANCE: Following screening and early disease detection in primary care via our optimized handheld OCT system, patients can be referred to a specialist for treatment, preventing further disease progression. While many primary care physicians are adept at using the ophthalmoscope, they can definitely take advantage of more advanced technologies.

3.
J Biophotonics ; 7(7): 525-33, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23606343

RESUMO

Optical coherence tomography (OCT) has long been used as a diagnostic tool in the field of ophthalmology. The ability to observe microstructural changes in the tissues of the eye has proved very effective in diagnosing ocular disease. However, this technology has yet to be introduced into the primary care office, where indications of disease are first encountered. We have developed a portable, handheld imaging probe for use in the primary care setting and evaluated its tissue site accessibility, ability to observe diseased tissue, and screening capabilities in in vivo human patients, particularly for pathologies related to the eye, ear and skin. Various stages of diabetic retinopathy were investigated using the handheld probe and early-stage diabetic retinopathy was flagged as abnormal from the OCT images. At such early stages of disease, it is difficult to observe abnormalities with the limited tools that are currently available to primary care physicians. These results indicate that OCT shows promise to transform from being a diagnostic technology in the medical and surgical specialities to a screening technology in the primary care office and at the front-line of healthcare.


Assuntos
Interpretação de Imagem Assistida por Computador/instrumentação , Programas de Rastreamento/instrumentação , Consultórios Médicos , Atenção Primária à Saúde/métodos , Tomografia de Coerência Óptica/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Aumento da Imagem/instrumentação , Miniaturização , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...