Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Surg Clin North Am ; 103(4): 703-731, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37455033

RESUMO

This article provides an overview of acute mesenteric ischemia, chronic mesenteric ischemia, and visceral aneurysms, with a focus on treatment. Acute mesenteric ischemia can be a challenging diagnosis. Early recognition and adequate revascularization are key to patient outcomes. Chronic mesenteric ischemia is a more insidious process, typically caused by atherosclerosis. Various options for revascularization exist, which must be tailored to each patient. Visceral aneurysms are rare and the natural history is not well defined. However, given the risk of rupture and high mortality, treatment may be complex.


Assuntos
Aneurisma , Isquemia Mesentérica , Oclusão Vascular Mesentérica , Humanos , Isquemia Mesentérica/diagnóstico , Isquemia Mesentérica/etiologia , Isquemia Mesentérica/cirurgia , Aneurisma/diagnóstico , Aneurisma/cirurgia , Procedimentos Cirúrgicos Vasculares , Isquemia , Doença Crônica , Resultado do Tratamento , Oclusão Vascular Mesentérica/terapia
2.
Trauma Surg Acute Care Open ; 6(1): e000617, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33490605

RESUMO

BACKGROUND: Resuscitative endovascular balloon occlusion of the aorta (REBOA) is an emerging technique used for non-compressible torso hemorrhage. However, its current use continues to be limited and there is a need for a simple, fast, and low profile REBOA device. Our objective was to evaluate the feasibility of a novel 4 French REBOA device called the COBRA-OS (Control of Bleeding, Resuscitation, Arterial Occlusion System). METHODS: This study is the first-in-human feasibility trial of the COBRA-OS. Due to the difficulty of trialing the device in the trauma setting, we performed a feasibility study using organ donors (due to the potential usefulness of the COBRA-OS for normothermic regional perfusion) after neurological determination of death (NDD) prior to organ retrieval. Bilateral 4 French introducer sheaths were placed in both femoral arteries and the COBRA-OS was advanced up the right side and deployed in the thoracic aorta (Zone 1). Once aortic occlusion was confirmed via the left-sided arterial line, the device was deflated, moved to the infrarenal aorta (Zone 3), and redeployed. RESULTS: A total of 7 NDD organ donors were entered into the study, 71% men, with a mean age 46.6 years (range 26 to 64). The COBRA-OS was able to occlude the aorta in Zones 1 and 3 in all patients. The mean time of placing a 4 French sheath was 47.7 seconds (n=13, range 28 to 66 seconds). The mean time from skin to Zone 1 aortic occlusion was 70.1 seconds (range 58 to 105 seconds); mean balloon volumes were 15 mL for Zone 1 (range 13 to 20 mL) and 9 mL for Zone 3 (range 6 to 15 mL); there were no complications and visual inspection of the aorta in all patients revealed no injury. DISCUSSION: The COBRA-OS is a novel 4 French REBOA device that has demonstrated fast and safe aortic occlusion in this first-in-human feasibility study. LEVEL OF EVIDENCE: Level V, therapeutic.

3.
J Vasc Surg ; 73(6): 1966-1972, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33249208

RESUMO

OBJECTIVE: Little evidence is available supporting the optimal treatment of type II endoleaks associated with aortic sac growth. Previous studies have lacked comparisons between treatment methods and long-term follow-up. The purpose of the present study was to review our center's experience with the treatment of type II endoleaks comparing Onyx (a liquid embolization agent consisting of ethylene vinyl alcohol; Medtronic, Minneapolis, Minn) embolization and coil embolization. METHODS: A retrospective review of prospectively collected data from a vascular surgery database was performed to identify all patients who had undergone embolization of a type II endoleak for aortic sac growth after endovascular aneurysm repair from 2005 to 2018. The Onyx and coil embolization groups were compared using univariate statistics. RESULTS: A total of 58 patients had undergone 77 embolization procedures for type II endoleaks with either Onyx (27 patients; 37 procedures) or coils (31 patients; 40 procedures). The average aneurysm size at embolization was larger in the Onyx group (77.9 ± 15.1 mm) compared with coil embolization (73.4 ± 11.9 mm). The mean follow-up was 57 months for the Onyx group and 74 months for the coil embolization group. Of the 27 patients who had undergone Onyx embolization, 2 (7.4%) had required graft explantation compared with 5 of the 31 patients (16.1%) who had undergone coil embolization (P = .33). The results of the per-patient analysis showed that the coil embolization group had a significantly greater rate of the need for further reintervention compared with the Onyx group (55% vs 19%; P < .01). Clinical success was observed in 13 patients (48%) in the Onyx embolization group compared with 10 patients (32%) in the coil embolization group (P = .04). Two patients in each group had presented with secondary rupture of the aneurysm sac after attempted embolization. CONCLUSIONS: Type II endoleaks associated with sac growth treated with Onyx were less likely to require further reinterventions than were those treated with coil embolization. A trend was found toward a greater need for endovascular aneurysm repair explant after coil embolization. With a high rate of further reintervention and potential for sac rupture, diligent follow-up is required after attempted type II embolization, regardless of the technique used.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/efeitos adversos , Dimetil Sulfóxido/administração & dosagem , Embolização Terapêutica/instrumentação , Endoleak/terapia , Procedimentos Endovasculares/efeitos adversos , Polivinil/administração & dosagem , Bases de Dados Factuais , Dimetil Sulfóxido/efeitos adversos , Embolização Terapêutica/efeitos adversos , Endoleak/diagnóstico por imagem , Endoleak/etiologia , Feminino , Humanos , Masculino , Polivinil/efeitos adversos , Retratamento , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
4.
J Vasc Surg ; 71(4): 1162-1168, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-31519509

RESUMO

OBJECTIVE: Patients older than 80 years have significantly lower early mortality with endovascular aneurysm repair (EVAR) compared with open repair for abdominal aortic aneurysms (AAAs), but long-term results remain poorly studied. We analyzed the results of both emergent and elective AAA repair in patients aged 80 years or older who had at least 5 years of follow-up. METHODS: Retrospective review of a prospectively collected vascular surgery database was performed to identify all patients who underwent elective repair of an AAA between 2007 and 2012 and were 80 years of age or older at the time of surgery. Open and EVAR groups were compared using univariate statistics. RESULTS: The study cohort was composed of 314 patients 80 years of age or older (median, 83 years; interquartile range, 5 years) who underwent repair (96 open, 218 EVAR). The groups had similar comorbidities, except that EVAR patients were more likely to be male and open repair patients were more likely to have larger aneurysms. Compared with open repair, elective early postoperative mortality was significantly lower for EVAR patients (1% vs 14%; P < .001). Overall mean life expectancy was 5.9 years (EVAR, 5.8 years; open repair, 5.8 years; P = .98). The 1-year survival was significantly higher for EVAR (92.9%) than for open repair (84.1%; P = .02). The 2-year survival (EVAR, 83.4%; open repair, 74.6%; P = .07) and 5-year survival (EVAR, 57.8%; open repair, 60.3%; P = .98) did not differ between EVAR and open repair. Reintervention rates (EVAR, 18%; open repair, 2%; P = .05) were higher in the endovascular treatment group. CONCLUSIONS: EVAR results in an improved 1-year mortality in octogenarians compared with open repair, although 5-year survival is similar between the groups. With average life expectancies of >5 years and an 18% reintervention rate, diligent follow-up is required after EVAR even in elderly patients.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Procedimentos Endovasculares , Procedimentos Cirúrgicos Vasculares/métodos , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/mortalidade , Feminino , Humanos , Expectativa de Vida , Masculino , Estudos Retrospectivos , Taxa de Sobrevida
5.
J Vasc Surg ; 70(3): 756-761.e1, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-30837183

RESUMO

OBJECTIVE: Infrarenal aortic neck angulation is one of the most powerful predictors of endovascular aneurysm repair failure. Whereas the "gold standard" to measure this angle is three-dimensional (3D) reconstruction and centerline measurement, many surgeons rely on estimations of angulation based on two-dimensional (2D) views of computed tomography imaging. Unfortunately, these views do not accurately represent the true angle, particularly if aortic angulation is oblique to the standard views. In response to this issue, our group has developed a novel trigonometric formula that uses coronal and sagittal measured angles to calculate the true angle. The purpose of this study was to compare the paired angle formula with 3D centerline measurements for estimating true aortic neck angulation. METHODS: Fifty randomly selected patients treated by endovascular aneurysm repair at The Ottawa Hospital between 2010 and 2015 were studied. The 3D centerline aortic neck angle measurements were made by a radiology staff physician. The paired angle formula was applied by a vascular surgeon, resident, and student using 2D coronal and sagittal angles from computed tomography imaging to estimate the true angle. RESULTS: The average age was 78 years; 74% of patients were male, and average preoperative aneurysm diameter was 5.7 cm. The mean neck length was 1.9 cm (1.1-3.2 cm), and mean neck angulation calculated by the gold standard measurements was 39 degrees (2-84 degrees). Linear regression demonstrated strong association between 3D measurements and the paired angle formula, with correlations comparable to the intraobserver variability (intraclass correlation coefficient values range, 0.74-0.87). The average user estimates deviated minimally from the gold standard (absolute difference, 6 degrees; 95% confidence interval, 4-8 degrees) without systemic bias. The paired angle formula accurately ruled out severe angulation >60 degrees with an overall negative predictive value of >99%. Compared with isolated 2D measurements, application of the paired angle formula significantly decreased the false-negative rate of unappreciated severe angulation >60 degrees from 4.8% to 0.7% (P = .032). CONCLUSIONS: The paired angle formula detects significantly more severe angles than isolated 2D measurements and can accurately rule out severe angulation >60 degrees compared with the 3D measurements. The implementation of this angle estimation method is a useful adjunct in the measurement of aortic neck angulation, especially if 3D reconstruction software is not readily available. Furthermore, the importance of accurate angle measurement is not limited to vascular surgery and has direct relevance to any procedural specialty that relies on preoperative angle measurements.


Assuntos
Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aortografia/métodos , Angiografia por Tomografia Computadorizada , Idoso , Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular , Bases de Dados Factuais , Procedimentos Endovasculares , Feminino , Humanos , Imageamento Tridimensional , Masculino , Variações Dependentes do Observador , Ontário , Valor Preditivo dos Testes , Interpretação de Imagem Radiográfica Assistida por Computador , Reprodutibilidade dos Testes , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...