Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 58
Filtrar
2.
J Clin Med ; 12(14)2023 Jul 18.
Artigo em Inglês | MEDLINE | ID: mdl-37510857

RESUMO

BACKGROUND: Concomitant mitral transcatheter edge-to-edge repair (M-TEER) and left atrial appendage closure (LAAC) showed to be a feasible approach to optimize the treatment of patients eligible for both procedures, but mid-term outcomes are unclear. METHODS: We retrospectively analyzed consecutive patients undergoing M-TEER and enrolled in the local prospective Getting Reduction of Mitral Insufficiency by Percutaneous Clip Implantation (GRASP) registry. We compared patients undergoing isolated M-TEER (n = 58, 58.5%) with those undergoing concomitant M-TEER and LAAC (n = 41, 41.5%) from January 2018 to December 2022. The primary endpoint was a composite of all-cause death, stroke or systemic embolism, hospitalization for heart failure, and bleeding at 1 year. The co-primary endpoint was procedural success. RESULTS: The primary endpoint was similar between patients undergoing concomitant M-TEER+LAAC or isolated M-TEER (Kaplan Meier (KM) estimates 36.6% vs. 44.8%; plog-rank = 0.75). Procedural success was also similar (92.7% vs. 94.8%; p = 0.69). At 1- year, minor bleeds were lower in patients undergoing concomitant M-TEER and LAAC (KM estimates 0.0% vs. 18.9%; plog-rank < 0.01). CONCLUSION: In patients with concomitant MR and AF and eligible for M-TEER and LAAC treatment, a combined approach of M-TEER and LAAC was as safe as an M-TEER-alone strategy and associated with lower minor bleeding at 1 year.

3.
J Cardiovasc Med (Hagerstown) ; 23(4): 216-227, 2022 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-35287156

RESUMO

Non-invasive cardiovascular imaging owns a pivotal role in the preoperative assessment of patients for transcatheter aortic valve implantation (TAVI), providing a wide range of crucial information to select the patients who will benefit the most and have the procedure done safely. Although advanced cardiac imaging with cardiac computed tomography is routinely used for a detailed anatomic assessment before TAVI, echocardiography remains the first imaging modality to assess aortic stenosis severity and to provide essential functional information. This document results from the collaboration between the Italian Society of Cardiology (SIC) and the Italian Society of Medical and Interventional Radiology (SIRM), aiming to produce an updated consensus statement about the pre-procedural imaging assessment in patient for TAVI. The writing committee is composed of radiologists and cardiologists, experts in the field of cardiac imaging and structural heart diseases. Part 1 of the document, after a brief overview of the clinical indication and basic technical aspects of TAVI, will focus on the role of echocardiography in TAVI pre-procedural planning.


Assuntos
Estenose da Valva Aórtica , Cardiologia , Implante de Prótese de Valva Cardíaca , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Ecocardiografia , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Radiologia Intervencionista , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos
4.
Radiol Med ; 127(3): 277-293, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35129758

RESUMO

Non-invasive cardiovascular imaging owns a pivotal role in the preoperative assessment of patient candidates for transcatheter aortic valve implantation (TAVI), providing a wide range of crucial information to select the patients who will benefit the most and have the procedure done safely. This document has been developed by a joined group of experts of the Italian Society of Cardiology and the Italian Society of Medical and Interventional Radiology and aims to produce an updated consensus statement about the pre-procedural imaging assessment in candidate patients for TAVI intervention. The writing committee consisted of members and experts of both societies who worked jointly to develop a more integrated approach in the field of cardiac and vascular radiology. Part 2 of the document will cover CT and MR angiography, standard medical reporting, and future perspectives.


Assuntos
Estenose da Valva Aórtica , Cardiologia , Substituição da Valva Aórtica Transcateter , Angiografia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Humanos , Tomografia Computadorizada por Raios X/métodos , Substituição da Valva Aórtica Transcateter/métodos
5.
Cardiovasc Revasc Med ; 40: 208-209, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35123915

RESUMO

The use of "Kissing Watchman" technique has been reported for left atrial appendage closure in particular case (i.e. large ostia). This case highlighted the feasibility of adapting this technique as bailout strategy in case of migration of a first device inside the LAA, due to a partial recapture of device.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Procedimentos Cirúrgicos Cardíacos , Acidente Vascular Cerebral , Apêndice Atrial/diagnóstico por imagem , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Cateterismo Cardíaco/efeitos adversos , Procedimentos Cirúrgicos Cardíacos/métodos , Humanos , Fatores de Tempo , Resultado do Tratamento
6.
J Clin Med ; 10(20)2021 Oct 16.
Artigo em Inglês | MEDLINE | ID: mdl-34682871

RESUMO

OBJECTIVES: To investigate how the changes of left ventricle ejection fraction (LVEF) between admission and discharge affected the long-term outcome in patients who underwent percutaneous edge-to-edge mitral valve repair for secondary mitral regurgitation. BACKGROUND: An acute impairment of LVEF after surgical repair of mitral regurgitation, known as afterload mismatch, has been associated with increased all-cause mortality. Afterload mismatch after percutaneous edge-to-edge mitral valve repair has been postulated to be a transient phenomenon. METHODS: This study is based on a single-center, retrospective, observational registry of patients who underwent percutaneous edge-to-edge mitral valve repair with the MitraClip (Abbot Vascular) system for the treatment of symptomatic, moderate-to-severe mitral regurgitation. We included data on 399 patients who underwent percutaneous edge-to-edge mitral valve repair for secondary mitral regurgitation. Expert echocardiographers assessed LVEF before the procedure and at discharge. The patients were divided into three groups according to the difference of periprocedural LVEF measurements: unchanged (n = 318), improved (n = 40), and decreased (n = 41) LVEF. RESULTS: The median follow-up time was 2.0 years. When adjusted for gender, NYHA class and estimated glomerular filtration rate, decreased postprocedural LVEF was associated with an increased risk of death (adjusted HR 2.05, 95% CI 1.26-3.34) and increased postprocedural LVEF with a reduced risk of death (adjusted HR 0.47, 95% CI 0.24-0.91) compared to unchanged LVEF. Conclusion: Among patients who underwent percutaneous edge-to-edge mitral valve repair, decreased postprocedural LVEF was associated with increased mortality, while improved LVEF was associated with lower mortality compared to unchanged LVEF.

8.
Cardiovasc Revasc Med ; 21(9): 1057-1062, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32001165

RESUMO

BACKGROUND: Available scientific evidence of transcatheter mitral valve repair with the MitraClip comes from randomized controlled trials, which showed controversial results that hardly translate into real-world practice, and from registries of relatively small sample size. AIM: To collect real-world data in a multicenter, prospective, country-level registry. METHODS AND RESULT: The Italian Society of Interventional Cardiology (GIse) Registry Of Transcatheter Treatment of Mitral Valve RegurgitaTiOn (GIOTTO) is an ongoing single-arm, multicenter, prospective registry that started enrollment in February 2016. Clinical end points were defined according to the Mitral Valve Academic Research Consortium (MVARC) criteria. From February 2016 to December 2018, 1189 patients (mean age 76 ±â€¯9.1 years) were enrolled. The main MR etiology was functional (64.9%). MVARC technical success was 96.6%. At 30-day follow-up (n = 1131), MVARC device and procedural success were 92.5% and 87% respectively, and all-cause death was 3%. The majority of patients who died at 30-day had functional MR (69.7%). Mixed etiology (OR 0.94, 95% CI 0.02-0.61) and prolonged length of stay in ICU (OR 0.97, 95% CI 0.95-0.99) were found to be negative independent predictors of device success at 30-day. The EuroSCORE II (OR 0.96, 95% CI 0.93-0.99), LVEDV-I (OR 0.99, 95% CI 0.98-0.99) and prolonged length of stay in ICU (OR 0.98, 95% CI 0.97-0.99) were negative independent factors of MVARC procedural success at 30-day. CONCLUSIONS: The GIOTTO registry is one of the largest prospective registries available on MitraClip and shows favorable acute and 30-day safety and efficacy.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Idoso , Idoso de 80 Anos ou mais , Cateterismo Cardíaco , Cardiologia , Humanos , Itália , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/cirurgia , Sistema de Registros , Resultado do Tratamento
9.
Am Heart J ; 217: 32-41, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31473325

RESUMO

Limited evidence is available on 5-year clinical outcomes after percutaneous edge-to-edge mitral valve repair. METHODS: The Getting Reduction of mitrAl inSufficiency by Percutaneous clip implantation in ITaly (GRASP-IT) is a multicenter registry including 304 consecutive patients undergoing Mitraclip between October 2008 and October 2013 at 4 Italian centers. Primary end point (all-cause mortality) and secondary end point (all-cause mortality or heart failure [HF] hospitalization) were evaluated up to 5 years and between 1 and 5 years. RESULTS: Cumulative incidence of the primary and secondary end points at 1, 2, 3, 4, and 5 years were 15.1%, 26.4%, 35.5%, 42.1%, and 47.3% and 29.1%, 41.7%, 49.8%, 56%, and 62.3%, respectively. Landmark analysis between 1 and 5 years showed an incidence of primary and secondary end point of 37.9% and 46.8%, respectively. Five-year event rates were significantly higher in patients with functional ischemic mitral regurgitation (MR) compared to other etiologies. MR recurrence and left ventricular ejection fraction <30% were associated with an increased risk of both primary and secondary end points. EuroSCORE II >5% was associated with an increased risk of 5-year mortality. Ischemic etiology of MR, baseline serum creatinine >1.5 mg/dL, chronic obstructive pulmonary disease, and previous HF hospitalizations were independent predictors of 5-year secondary end point. CONCLUSIONS: At 5-year follow-up after Mitraclip, nearly half of patients died and almost two thirds died or were admitted for HF. MR recurrence, ischemic etiology, high comorbidity burden (ie, EuroSCORE II >5%, chronic obstructive pulmonary disease), and advanced cardiomyopathy (ie, left ventricular ejection fraction <30%, prior HF admission, creatinine >1.5 mg/dL) significantly increase the relative risk of 5-year clinical events.


Assuntos
Insuficiência Cardíaca/epidemiologia , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Complicações Pós-Operatórias/epidemiologia , Idoso , Procedimentos Cirúrgicos Cardíacos/instrumentação , Procedimentos Cirúrgicos Cardíacos/métodos , Causas de Morte , Feminino , Insuficiência Cardíaca/etiologia , Hospitalização/estatística & dados numéricos , Humanos , Incidência , Itália , Masculino , Insuficiência da Valva Mitral/epidemiologia , Insuficiência da Valva Mitral/mortalidade , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/mortalidade , Doença Pulmonar Obstrutiva Crônica/epidemiologia , Recidiva , Sistema de Registros/estatística & dados numéricos , Estudos Retrospectivos , Volume Sistólico , Fatores de Tempo , Resultado do Tratamento , Função Ventricular Esquerda
10.
Am J Cardiol ; 121(10): 1253-1259, 2018 05 15.
Artigo em Inglês | MEDLINE | ID: mdl-29650238

RESUMO

The pattern and reasons for re-hospitalization (RH) after MitraClip implantation are not well characterized. A total of 322 consecutive MitraClip patients were included, with data stratified by RH status. Multivariate analyses were conducted to identify predictors of early (30-day) and late (30-day to 12-month) RH. Eighty-nine patients (27.6%) were readmitted to hospital during the study period and early RH occurred in 27%. The median time from MitraClip to RH was 99 days. RH was mostly related to cardiovascular causes (66.3%). Anemia and gastrointestinal bleeding were the most frequent noncardiovascular causes. Independent predictors of early RH were length of stay ≥3 days during the index procedure (odds ratio [OR] 4.13, 95% confidence interval [CI] 1.32 to 12.91), reduction of left ventricular ejection fraction ≥5% after MitraClip implantation (OR 4.88, 95% CI 1.36 to 18.91), and severe systolic pulmonary artery pressure ≥60 mm Hg at discharge (OR 3.72, 95% CI 1.23 to 11.26). Conversely, the independent predictors of late RH were device failure (OR 4.02, 95% CI 1.22 to 13.25) and systolic pulmonary artery pressure ≥60 mm Hg at discharge (OR 2.34, 95% CI 1.01 to 5.44). In patients with early RHs, survival was significantly worse at 12 months compared with patients with late RH and no-RH (69.3% vs 82.6% vs 86%, p <0.001). In conclusion, RH is not uncommon after MitraClip implantation and cardiovascular causes represent its most frequent etiology. Clinical and echocardiographic predictors of early and late RH can be identified at discharge. Early RH carries a worse prognosis than late RH.


Assuntos
Anemia/epidemiologia , Doenças Cardiovasculares/epidemiologia , Hemorragia Gastrointestinal/epidemiologia , Hipertensão Pulmonar/epidemiologia , Tempo de Internação/estatística & dados numéricos , Anuloplastia da Valva Mitral , Insuficiência da Valva Mitral/cirurgia , Readmissão do Paciente/estatística & dados numéricos , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Hipertensão Pulmonar/fisiopatologia , Incidência , Itália/epidemiologia , Masculino , Mortalidade , Análise Multivariada , Razão de Chances , Prognóstico , Índice de Gravidade de Doença , Volume Sistólico , Instrumentos Cirúrgicos , Fatores de Tempo
12.
J Clin Endocrinol Metab ; 102(10): 3756-3764, 2017 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-28973588

RESUMO

Context: Prediabetes is associated with subclinical cardiac changes associated with heart failure development. Objective: We investigated diastolic function and its association with markers of glycation and inflammation related to cardiovascular disease in patients with prediabetes. We focused on individuals with prediabetes identified only by glycated hemoglobin A1c [HbA1c; 5.7% to 6.4% and normal fasting glucose (NFG) and normal glucose tolerance (NGT) after an oral glucose tolerance test (OGTT)]. Design: Cross-sectional study. Setting: Departments of Clinical and Experimental Medicine and Cardiology, University of Catania, Catania, Italy. Main Outcome Measures: HbA1c, OGTT, Doppler echocardiography, soluble receptor for advanced glycation end products (sRAGEs), and endogenous secretory RAGE (esRAGE) were evaluated. Patients: We recruited 167 subjects with NFG/NGT who were stratified according to HbA1c level: controls (HbA1c <5.7%) and HbA1c prediabetes (HbA1c 5.7% to 6.4%). Results: Patients with HbA1c prediabetes (n = 106) showed a lower peak mitral inflow in early diastole (E wave) to late diastolic atrial filling velocity (A wave) ratio (E/A ratio) than controls (n = 61) (1.10 ± 0.24 vs 1.18 ± 0.23; P < 0.05). They showed a higher left atrium volume (LAV) (28.4 ± 5 vs 22.1 ± 3; P < 0.05) and sphericity index (SI) (0.6 ± 0.06 vs 0.5 ± 0.05; P < 0.05). After multiple regression analyses, HbA1c, sRAGE, and esRAGE were the major determinants of E/A ratio, LAV, and SI. Conclusions: Subjects with HbA1c prediabetes exhibited subclinical cardiac alterations associated with sRAGE, esRAGE, and HbA1c. These subjects would not have been classified as having prediabetes on the basis of fasting glycemia or post-OGTT values.


Assuntos
Hemoglobinas Glicadas/análise , Estado Pré-Diabético/sangue , Estado Pré-Diabético/complicações , Estado Pré-Diabético/diagnóstico , Disfunção Ventricular Esquerda/complicações , Disfunção Ventricular Esquerda/diagnóstico , Adolescente , Adulto , Idoso , Doenças Assintomáticas , Glicemia/análise , Estudos Transversais , Diástole , Jejum , Feminino , Teste de Tolerância a Glucose , Humanos , Masculino , Pessoa de Meia-Idade , Estado Pré-Diabético/classificação , Disfunção Ventricular Esquerda/sangue , Adulto Jovem
13.
JACC Cardiovasc Interv ; 10(16): 1662-1670, 2017 08 28.
Artigo em Inglês | MEDLINE | ID: mdl-28838477

RESUMO

OBJECTIVES: This study is the first report of 2 cases of HighLife (HighLife, Paris, France) implantation in humans. BACKGROUND: Transcatheter mitral valve implantation represents a promising approach to treating mitral regurgitation in patients at increased risk of perioperative mortality. The HighLife transcatheter mitral valve is a 2-component system. The valve is implanted in the mitral position and is anchored by interacting and then reaching an equilibrium position with a previously positioned subannular implant. METHODS: The procedures were successfully performed in a 69-year-old man and a 65-year-old woman with severe functional mitral regurgitation. Both patients were in New York Heart Association functional class IV heart failure with depressed left ventricular ejection fraction and additional comorbidities. RESULTS: The valve was implanted uneventfully in both patients. General anesthesia was used. The subannular implant was deployed through the transfemoral access, whereas the transcatheter mitral valve was released using the transapical access. Patients maintained hemodynamically stable. There were no intraoperative complications. Acutely, post-procedural echocardiograms demonstrated excellent prosthetic valve function with a low transvalvular gradient and no paravalvular leak and left ventricular outflow tract obstruction. Both patients had mild intraprosthetic regurgitation. Patient #1 survived at 5-months follow-up in New York Heart Association functional class II with excellent prosthesis performance. Patient #2 expired 4 days after a technically successful procedure, because the left ventricle did not tolerate the reduction of mitral regurgitation and despite a high dose of inotropic agents the left ventricular function rapidly deteriorated. CONCLUSIONS: Transcatheter mitral valve implantation using the 2-component HighLife system is technically feasible and can be performed safely. Early hemodynamic performance of the prosthesis was excellent.


Assuntos
Cateterismo Cardíaco/instrumentação , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Idoso , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/métodos , Ecocardiografia Tridimensional , Ecocardiografia Transesofagiana , Evolução Fatal , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Hemodinâmica , Humanos , Masculino , Valva Mitral/diagnóstico por imagem , Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/fisiopatologia , Tomografia Computadorizada Multidetectores , Desenho de Prótese , Recuperação de Função Fisiológica , Volume Sistólico , Fatores de Tempo , Resultado do Tratamento , Função Ventricular Esquerda
14.
Echocardiography ; 34(9): 1379-1381, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28612452

RESUMO

We present a case of a patient with severe mitral regurgitation referred to our Institution for an echocardiographic examination as part of the routine workup to assess the eligibility for mitral valve percutaneous repair with either the MitraClip or Cardioband systems. Echocardiography showed the presence of an unusual interatrial membrane in the left atrium that represented a contraindication for the puncture of the interatrial septum. The patient was finally deferred to percutaneous mitral valve replacement using transapical access.


Assuntos
Septo Interatrial/cirurgia , Cateterismo Cardíaco/métodos , Procedimentos Cirúrgicos Cardíacos/métodos , Átrios do Coração/diagnóstico por imagem , Comunicação Interatrial/cirurgia , Insuficiência da Valva Mitral/cirurgia , Idoso , Septo Interatrial/diagnóstico por imagem , Ecocardiografia Doppler em Cores , Ecocardiografia Transesofagiana , Comunicação Interatrial/complicações , Comunicação Interatrial/diagnóstico , Humanos , Masculino , Valva Mitral , Insuficiência da Valva Mitral/diagnóstico , Insuficiência da Valva Mitral/etiologia
15.
Am J Cardiol ; 119(9): 1443-1449, 2017 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-28274574

RESUMO

There is a lack of specific tools for risk stratification in patients who undergo MitraClip implantation. We aimed at combining preprocedural variables with prognostic impact into a specific risk model for the prediction of 1-year mortality in patients undergoing MitraClip implantation. A total of 311 consecutive patients who underwent MitraClip implantation were included. A lasso-penalized Cox-proportional hazard regression model was used to identify independent predictors of 1-year all-cause mortality. A nomogram (GRASP [Getting Reduction of mitrAl inSufficiency by Percutaneous clip implantation] nomogram) was obtained from the Cox model. Validation was performed using internal bootstrap resampling. Forty-two deaths occurred at 1-year follow-up. The Kaplan-Meier estimate of 1-year survival was 0.845 (95% confidence interval, 0.802 to 0.895). Four independent predictors of mortality (mean arterial blood pressure, hemoglobin natural log-transformed pro-brain natriuretic peptide levels, New York Heart Association class IV at presentation) were identified. At internal bootstrap resampling validation, the GRASP nomogram had good discrimination (area under receiver operating characteristic curve of 0.78, Somers' Dxy statistic of 0.53) and calibration (le Cessie-van Houwelingen-Copas-Hosmer p value of 0.780). Conversely, the discriminative ability of the EuroSCORE II (the European System for Cardiac Operative Risk Evaluation II) and the STS-PROM (the Society of Thoracic Surgeons Predicted Risk of Mortality score) was fairly modest with area under the curve values of 0.61 and 0.55, respectively. A treatment-specific risk model in patients who undergo MitraClip implantation may be useful for the stratification of mortality at 1 year. Further studies are needed to provide external validation and support the generalizability of the GRASP nomogram.


Assuntos
Anuloplastia da Valva Mitral/mortalidade , Insuficiência da Valva Mitral/cirurgia , Sistema de Registros , Idoso , Idoso de 80 Anos ou mais , Pressão Arterial , Causas de Morte , Feminino , Hemoglobinas/metabolismo , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Insuficiência da Valva Mitral/sangue , Insuficiência da Valva Mitral/fisiopatologia , Peptídeo Natriurético Encefálico/sangue , Nomogramas , Fragmentos de Peptídeos/sangue , Modelos de Riscos Proporcionais , Curva ROC , Reprodutibilidade dos Testes , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Instrumentos Cirúrgicos , Resultado do Tratamento
16.
Cardiology ; 137(2): 114-120, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28324874

RESUMO

Percutaneous mitral valve repair (PMVR) with the MitraClip system (Abbott Vascular, Santa Clara, CA, USA) is a valid therapeutic option for patients with severe mitral regurgitation (MR) deemed to be at high or prohibitive surgical risk. Despite the reassuring data on efficacy and long-term durability of the procedure, the proportion of patients with residual or relapsing severe MR after MitraClip therapy is not negligible. In light of the detrimental prognostic impact of severe MR, repeat interventions are increasingly performed in clinical practice using different techniques. In high-risk settings, percutaneous procedures have proven to be effective and safe at reducing MR. Building on this, we sought to summarize the current landscape and clinical experience of reinterventions after failed MitraClip therapy, so as to assist physicians facing the clinical hurdle of proper treatment management after failed PMVR.


Assuntos
Cateterismo Cardíaco/instrumentação , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/terapia , Valva Mitral/diagnóstico por imagem , Idoso , Cateterismo Cardíaco/efeitos adversos , Ecocardiografia Transesofagiana , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/fisiopatologia , Recidiva , Fatores de Risco , Índice de Gravidade de Doença , Resultado do Tratamento
17.
Heart ; 103(12): 931-936, 2017 06.
Artigo em Inglês | MEDLINE | ID: mdl-28069638

RESUMO

BACKGROUND: Percutaneous edge-to-edge mitral valve repair (PMVR) recently emerged as an effective treatment modality for patients with severe mitral regurgitation (MR). Length of postprocedural hospital stay may represent a modifiable cost associated with percutaneous treatment. We looked at feasibility, predictors and safety of early discharge (ED), defined as hospital discharge within 72 hours, in patients undergoing PMVR. METHODS AND RESULTS: Consecutive patients treated with MitraClip from October 2008 to December 2015 were analysed. Primary outcomes of interest were cardiovascular and non-cardiovascular mortality, rehospitalisation for heart failure and major adverse events at 30 days and 90 days. A total of 269 patients were included. Of these, 115 patients were early discharged (ED group). Rates of ED increased from 25.9% for the biennium 2008-2009 to 59.1% in 2014-2015 (p<0.001 for trend). In a penalised logistic regression model, male gender (OR=2.13, 95% CI 1.17 to 3.95) and procedural year (OR=2.13, 95% CI 1.51 to 3.11) were associated with higher probability of ED. Conversely, atrial fibrillation (OR=0.48, 95% CI 0.27 to 0.85), any Mitral Valve Academic Research Consortium bleeding (OR=0.07, 95% CI 0.01 to 0.60), log-transformed N-terminal pro-brain natriuretic peptide levels (OR=0.79, 95% CI 0.63 to 0.99) and postimplant MR grade (OR=0.60, 95% CI 0.37 to 0.94) conferred a lower likelihood of ED. In propensity score-weighted analyses, overall survival, freedom from heart failure and major adverse events at 30 days and 90 days were not different in ED and non-ED groups (all weighted log-rank p value>0.05). CONCLUSIONS: In selected patients undergoing PMVR, ED may be feasible and safe.


Assuntos
Cateterismo Cardíaco/métodos , Implante de Prótese de Valva Cardíaca/métodos , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Alta do Paciente/tendências , Idoso , Ecocardiografia , Estudos de Viabilidade , Feminino , Seguimentos , Humanos , Masculino , Insuficiência da Valva Mitral/diagnóstico , Prognóstico , Sistema de Registros , Estudos Retrospectivos , Índice de Gravidade de Doença , Fatores de Tempo
20.
Ann Thorac Surg ; 102(6): e517-e519, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27847070

RESUMO

New-onset systolic anterior motion of the anterior mitral valve leaflet in patients undergoing transcatheter aortic valve replacement is a rare pathophysiologic mechanism leading to postprocedural development of mitral regurgitation and, eventually, left ventricular outflow obstruction. We report the first human case of successful MitraClip implantation to treat new-onset systolic anterior motion of the mitral valve after transcatheter aortic valve replacement causing severe obstruction to left ventricular outflow that was unresponsive to standard medical therapy.


Assuntos
Insuficiência da Valva Mitral/etiologia , Insuficiência da Valva Mitral/cirurgia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Obstrução do Fluxo Ventricular Externo/etiologia , Obstrução do Fluxo Ventricular Externo/cirurgia , Idoso , Feminino , Humanos , Insuficiência da Valva Mitral/diagnóstico por imagem , Obstrução do Fluxo Ventricular Externo/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...