Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Eur J Heart Fail ; 26(3): 686-694, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38481353

RESUMO

AIMS: A common feature of various forms of pulmonary hypertension (PH) is progressive decline of pulmonary arterial compliance (CPA), which correlates with reduced survival. In this acute study, we evaluated feasibility, safety and haemodynamic performance of the Aria pulmonary endovascular device in patients with PH associated with left heart disease (PH-LHD) and chronic lung disease (PH-CLD). METHODS AND RESULTS: Eight patients with PH-LHD and 10 patients with PH-CLD were included in this study. The device was placed in the main pulmonary artery via the right femoral vein and was connected by a catheter to a gas-filled reservoir outside the body. During systole, gas shifts from the balloon to the reservoir, leading to deflation of the balloon. In diastole, the gas returns from the reservoir to the balloon, leading to balloon inflation and enhancing diastolic blood flow to the distal pulmonary capillary bed. Haemodynamics were assessed at baseline, and again with device off, device on and device off. The primary safety endpoint was the incidence of serious adverse events through 30 days after the procedure. No complications or investigational device-related serious adverse events occurred. Device activation in PH-LHD and PH-CLD patients decreased pulmonary arterial pulse pressure by 5.6 ± 4.2 mmHg (-12%; p = 0.003) and 4.2 ± 2.2 mmHg (-11%; p < 0.001), increased CPA by 0.4 ± 0.2 ml/mmHg (+23%; p = 0.004) and 0.4 ± 0.3 ml/mmHg (+25%; p = 0.001), and increased right ventricular-to-pulmonary vascular (RV-PV) coupling by 0.24 ± 0.18 (+40%; p = 0.012) and 0.11 ± 0.07 (+21%; p = 0.001), respectively. CONCLUSIONS: Temporary implantation of the Aria endovascular device was feasible and safe. Device activation resulted in acute improvement of CPA and RV-PV coupling.


Assuntos
Hipertensão Pulmonar , Humanos , Masculino , Feminino , Hipertensão Pulmonar/fisiopatologia , Pessoa de Meia-Idade , Idoso , Resultado do Tratamento , Hemodinâmica/fisiologia , Estudos de Viabilidade , Artéria Pulmonar/fisiopatologia , Procedimentos Endovasculares/métodos , Desenho de Equipamento
2.
Pulm Circ ; 14(1): e12310, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38205098

RESUMO

Pulmonary hypertension (PH) due to interstitial lung disease (ILD), a commonly encountered complication of fibrotic ILDs, is associated with significant morbidity and mortality. Until recently, the studies of pulmonary vasodilator therapy in PH-ILD have been largely disappointing, with some even demonstrating the potential for harm. This paper is part of a series of Consensus Statements from the Pulmonary Vascular Research Institute's Innovative Drug Development Initiative for Group 3 Pulmonary Hypertension, with prior publications covering pathogenesis, prevalence, clinical features, phenotyping, clinical trials, and impact of PH-ILD. It offers a comprehensive review of and a holistic approach to treatment of PH-ILD, including the management of underlying interstitial lung diseases, importance of treating the comorbidities, emphasis on importance of exercise and palliation of dyspnea, and review of the most up-to-date guidelines for referral for potential lung transplant work up. It also summarizes the prior, ongoing, and possibly future studies in treatment of the vascular derangement of this morbid condition.

4.
Ann Am Thorac Soc ; 13(2): 276-84, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26848601

RESUMO

The normal pulmonary circulation is a low-pressure, high-compliance system. Pulmonary arterial compliance decreases in the presence of pulmonary hypertension because of increased extracellular matrix/collagen deposition in the pulmonary arteries. Loss of pulmonary arterial compliance has been consistently shown to be a predictor of increased mortality in patients with pulmonary hypertension, even more so than pulmonary vascular resistance in some studies. Decreased pulmonary arterial compliance causes premature reflection of waves from the distal pulmonary vasculature, leading to increased pulsatile right ventricular afterload and eventually right ventricular failure. Evidence suggests that decreased pulmonary arterial compliance is a cause rather than a consequence of distal small vessel proliferative vasculopathy. Pulmonary arterial compliance decreases early in the disease process even when pulmonary artery pressure and pulmonary vascular resistance are normal, potentially enabling early diagnosis of pulmonary vascular disease, especially in high-risk populations. With the recognition of the prognostic importance of pulmonary arterial compliance, its impact on right ventricular function, and its contributory role in the development and progression of distal small-vessel proliferative vasculopathy, pulmonary arterial compliance is an attractive target for the treatment of pulmonary hypertension.


Assuntos
Hipertensão Pulmonar/fisiopatologia , Artéria Pulmonar/fisiopatologia , Circulação Pulmonar/fisiologia , Rigidez Vascular/fisiologia , Disfunção Ventricular Direita/fisiopatologia , Complacência (Medida de Distensibilidade)/fisiologia , Insuficiência Cardíaca , Humanos , Neovascularização Patológica/fisiopatologia , Prognóstico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...