Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 99
Filtrar
1.
JPhys Photonics ; 6(3): 035021, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38975030

RESUMO

Lens biomechanical properties are critical for our eyes to accommodate. While it is well understood that lens mechanical properties change with age, different experimental techniques have been used over the years, with varying results on how the lens modulus changes. In this study, we developed a spatial-varying elasticity model to characterize the overall elastic modulus of the lens and establish its effect on accommodation. First, to validate the model, ex vivo porcine lenses underwent compression testing using biopsy punches of different diameters to change the percentage of nucleus within samples. Importantly, we found that, indeed, changing nucleus/cortex spatial ratio produces dramatic (∼7-fold) increase in overall sample modulus. Comparing the model with human lens spatial ratios, we demonstrate how changing spatial mechanics are more influential than peak modulus changes on overall elastic modulus. Next, in vivo clinical measurements of the spatial-varying lens modulus were used to generate a simplified mechanical-optical model of accommodation. We defined an ellipsoid lens with patient-derived modulus and geometry measurements, and a statics simulation and ray tracing analysis were performed through the deformed and undeformed lens. The resulting accommodation estimates agree with general accommodation expectations.

2.
JPhys Photonics ; 6(3): 032001, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38939757

RESUMO

Stimulated Brillouin scattering (SBS) microscopy is a nonlinear all-optical imaging method that provides mechanical contrast based on the interaction of laser radiation and acoustical vibrational modes. Featuring high mechanical specificity and sensitivity, three-dimensional sectioning, and practical imaging times, SBS microscopy with (quasi) continuous wave excitation is rapidly advancing as a promising imaging tool for label-free visualization of viscoelastic information of materials and living biological systems. In this article, we introduce the theory of SBS microscopy and review the current state-of-the-art as well as recent innovations, including different approaches to system designs and data analysis. In particular, various performance parameters of SBS microscopy and its applications in the life sciences are described and discussed. Future perspectives for SBS microscopy are also presented.

3.
Front Mol Neurosci ; 17: 1394058, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38828282

RESUMO

During the first month of pregnancy, the brain and spinal cord are formed through a process called neurulation. However, this process can be altered by low serum levels of folic acid, environmental factors, or genetic predispositions. In 2018, a surveillance study in Botswana, a country with a high incidence of human immunodeficiency virus (HIV) and lacking mandatory food folate fortification programs, found that newborns whose mothers were taking dolutegravir (DTG) during the first trimester of pregnancy had an increased risk of neural tube defects (NTDs). As a result, the World Health Organization and the U.S. Food and Drug Administration have issued guidelines emphasizing the potential risks associated with the use of DTG-based antiretroviral therapies during pregnancy. To elucidate the potential mechanisms underlying the DTG-induced NTDs, we sought to assess the potential neurotoxicity of DTG in stem cell-derived brain organoids. The gene expression of brain organoids developed in the presence of DTG was analyzed by RNA sequencing, Optical Coherence Tomography (OCT), Optical Coherence Elastography (OCE), and Brillouin microscopy. The sequencing data shows that DTG induces the expression of the folate receptor (FOLR1) and modifies the expression of genes required for neurogenesis. The Brillouin frequency shift observed at the surface of DTG-exposed brain organoids indicates an increase in superficial tissue stiffness. In contrast, reverberant OCE measurements indicate decreased organoid volumes and internal stiffness.

4.
Opt Express ; 32(11): 18572-18581, 2024 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-38859010

RESUMO

Brillouin spectrometers, used for characterizing material mechanical properties, traditionally employ etalons such as Fabry-Pérot interferometers and virtually imaged phased arrays (VIPA) that use spatial dispersion of the spectrum for measurement. Here, we introduce what we believe to be a novel approach to Brillouin spectroscopy using hot atomic vapors. Using laser induced circular dichroism of the rubidium D2 line in a ladder-type configuration, we developed a narrow-band monochromator for Brillouin analysis. Unlike etalon-based spectrometers, atomic line monochromators operate in free-space, facilitating Brillouin spectroscopy integration with microscopy instruments. We report the transmission and spectral resolution performances of the spectrometer and demonstrate Brillouin spectra measurements in liquids.

5.
Development ; 151(10)2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38682273

RESUMO

Neurulation is a highly synchronized biomechanical process leading to the formation of the brain and spinal cord, and its failure leads to neural tube defects (NTDs). Although we are rapidly learning the genetic mechanisms underlying NTDs, the biomechanical aspects are largely unknown. To understand the correlation between NTDs and tissue stiffness during neural tube closure (NTC), we imaged an NTD murine model using optical coherence tomography (OCT), Brillouin microscopy and confocal fluorescence microscopy. Here, we associate structural information from OCT with local stiffness from the Brillouin signal of embryos undergoing neurulation. The stiffness of neuroepithelial tissues in Mthfd1l null embryos was significantly lower than that of wild-type embryos. Additionally, exogenous formate supplementation improved tissue stiffness and gross embryonic morphology in nullizygous and heterozygous embryos. Our results demonstrate the significance of proper tissue stiffness in normal NTC and pave the way for future studies on the mechanobiology of normal and abnormal embryonic development.


Assuntos
Defeitos do Tubo Neural , Tubo Neural , Neurulação , Tomografia de Coerência Óptica , Animais , Tomografia de Coerência Óptica/métodos , Camundongos , Defeitos do Tubo Neural/genética , Defeitos do Tubo Neural/metabolismo , Defeitos do Tubo Neural/patologia , Tubo Neural/metabolismo , Neurulação/genética , Metilenotetra-Hidrofolato Desidrogenase (NADP)/genética , Metilenotetra-Hidrofolato Desidrogenase (NADP)/metabolismo , Formiatos/metabolismo , Embrião de Mamíferos/metabolismo , Feminino , Formiato-Tetra-Hidrofolato Ligase/genética , Formiato-Tetra-Hidrofolato Ligase/metabolismo , Mutação/genética , Fenômenos Biomecânicos , Microscopia Confocal , Camundongos Knockout
6.
Curr Opin Cell Biol ; 88: 102341, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38471195

RESUMO

Recent research has highlighted the growing significance of the mechanical properties of cells and tissues in the proper execution of physiological functions within an organism; alterations to these properties can potentially result in various diseases. These mechanical properties can be assessed using various techniques that vary in spatial and temporal resolutions as well as applications. Due to the wide range of mechanical behaviors exhibited by cells and tissues, a singular mapping technique may be insufficient in capturing their complexity and nuance. Consequently, by utilizing a combination of methods-multimodal mechanical mapping-researchers can achieve a more comprehensive characterization of mechanical properties, encompassing factors such as stiffness, modulus, viscoelasticity, and forces. Furthermore, different mapping techniques can provide complementary information and enable the exploration of spatial and temporal variations to enhance our understanding of cellular dynamics and tissue mechanics. By capitalizing on the unique strengths of each method while mitigating their respective limitations, a more precise and holistic understanding of cellular and tissue mechanics can be obtained. Here, we spotlight Brillouin microscopy (BM) as a noncontact, noninvasive, and label-free mechanical mapping modality to be coutilized alongside established mechanical probing methods. This review summarizes some of the most widely adopted individual mechanical mapping techniques and highlights several recent multimodal approaches demonstrating their utility. We envision that future studies aim to adopt multimodal techniques to drive advancements in the broader realm of mechanobiology.


Assuntos
Microscopia , Humanos , Animais , Fenômenos Biomecânicos
7.
Dev Dyn ; 2024 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-38501709

RESUMO

BACKGROUND: The brain and spinal cord formation is initiated in the earliest stages of mammalian pregnancy in a highly organized process known as neurulation. Environmental or genetic interferences can impair neurulation, resulting in clinically significant birth defects known collectively as neural tube defects. The Fuz gene encodes a subunit of the CPLANE complex, a macromolecular planar polarity effector required for ciliogenesis. Ablation of Fuz in mouse embryos results in exencephaly and spina bifida, including dysmorphic craniofacial structures due to defective cilia formation and impaired Sonic Hedgehog signaling. RESULTS: We demonstrate that knocking Fuz out during embryonic mouse development results in a hypoplastic hindbrain phenotype, displaying abnormal rhombomeres with reduced length and width. This phenotype is associated with persistent reduction of ventral neuroepithelial stiffness in a notochord adjacent area at the level of the rhombomere 5. The formation of cranial and paravertebral ganglia is also impaired in these embryos. CONCLUSIONS: This study reveals that hypoplastic hindbrain development, identified by abnormal rhombomere morphology and persistent loss of ventral neuroepithelial stiffness, precedes exencephaly in Fuz ablated murine mutants, indicating that the gene Fuz has a critical function sustaining normal neural tube development and neuronal differentiation.

8.
Ophthalmology ; 131(5): e23-e24, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38219143
9.
bioRxiv ; 2024 Mar 06.
Artigo em Inglês | MEDLINE | ID: mdl-38234798

RESUMO

Tissues are active materials where epithelial turnover, immune surveillance, and remodeling of stromal cells such as macrophages all regulate form and function. Scattering modalities such as Brillouin microscopy (BM) can non-invasively access mechanical signatures at GHz. However, our traditional understanding of tissue material properties is derived mainly from modalities which probe mechanical properties at different frequencies. Thus, reconciling measurements amongst these modalities remains an active area. Here, we compare optical tweezer active microrheology (OT-AMR) and Brillouin microscopy (BM) to longitudinally map brain development in the larval zebrafish. We determine that each measurement is able to detect a mechanical signature linked to functional units of the brain. We demonstrate that the corrected BM-Longitudinal modulus using a density factor correlates well with OT-AMR storage modulus at lower frequencies. We also show that the brain tissue mechanical properties are dependent on both the neuronal architecture and the presence of macrophages. Moreover, the BM technique is able to delineate the contributions to mechanical properties of the macrophage from that due to colony stimulating factor 1 receptor (CSF1R) mediated stromal remodeling. Here, our data suggest that macrophage remodeling is instrumental in the maintenance of tissue mechanical homeostasis during development. Moreover, the strong agreement between the OT-AM and BM further demonstrates that scattering-based technique is sensitive to both large and minute structural modification in vivo.

10.
ACS Photonics ; 11(1): 267-275, 2024 Jan 17.
Artigo em Inglês | MEDLINE | ID: mdl-38249682

RESUMO

Microlasers have been widely used in biosensing applications because of their high sensitivity to changes in local conditions. However, in most applications, the sensitivity limit is not dictated by the microlaser line width but rather by the much worse spectral resolution of the detection system, typically a grating spectrometer. To address this issue, we built and characterized a two-dimensional (2D) dispersion spectrometer with a virtually imaged phase array etalon and a diffraction grating. The spectrometer can analyze microlaser emission with a spectral resolution of better than 0.300 pm, which enables high-precision measurements of spectral shifts in laser peak emission wavelength and sufficient resolution to detect changes in peak line width. Using commercial fluorescent microspheres as the microlasers, the 2D dispersion spectrometer demonstrated a detection limit for the refractive index change of a liquid medium of 1.37 × 10-5 RIU and a detection limit for absorption changes of less than 0.02 cm-1.

11.
Ophthalmology ; 131(3): 310-321, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37839561

RESUMO

PURPOSE: To characterize focal biomechanical alterations in subclinical keratoconus (SKC) using motion-tracking (MT) Brillouin microscopy and evaluate the ability of MT Brillouin metrics to differentiate eyes with SKC from normal control eyes. DESIGN: Prospective cross-sectional study. PARTICIPANTS: Thirty eyes from 30 patients were evaluated, including 15 eyes from 15 bilaterally normal patients and 15 eyes with SKC from 15 patients. METHODS: All patients underwent Scheimpflug tomography and MT Brillouin microscopy using a custom-built device. Mean and minimum MT Brillouin values within the anterior plateau region and anterior 150 µm were generated. Scheimpflug metrics evaluated included inferior-superior (IS) value, maximum keratometry (Kmax), thinnest corneal thickness, asymmetry indices, Belin/Ambrosio display total deviation, and Ambrosio relational thickness. Receiver operating characteristic (ROC) curves were generated for all Scheimpflug and MT Brillouin metrics evaluated to determine the area under the ROC curve (AUC), sensitivity, and specificity for each variable. MAIN OUTCOME MEASURES: Discriminative performance based on AUC, sensitivity, and specificity. RESULTS: No significant differences were found between groups for age, sex, manifest refraction spherical equivalent, corrected distance visual acuity, Kmax, or KISA% index. Among Scheimpflug metrics, significant differences were found between groups for thinnest corneal thickness (556 µm vs. 522 µm; P < 0.001), IS value (0.29 diopter [D] vs. 1.05 D; P < 0.001), index of vertical asymmetry (IVA; 0.10 vs. 0.19; P < 0.001), and keratoconus index (1.01 vs. 1.05; P < 0.001), and no significant differences were found for any other Scheimpflug metric. Among MT Brillouin metrics, clear differences were found between control eyes and eyes with SKC for mean plateau (5.71 GHz vs. 5.68 GHz; P < 0.0001), minimum plateau (5.69 GHz vs. 5.65 GHz; P < 0.0001), mean anterior 150 µm (5.72 GHz vs. 5.68 GHz; P < 0.0001), and minimum anterior 150 µm (5.70 GHz vs. 5.66 GHz; P < 0.001). All MT Brillouin plateau and anterior 150 µm mean and minimum metrics fully differentiated groups (AUC, 1.0 for each), whereas the best performing Scheimpflug metrics were keratoconus index (AUC, 0.91), IS value (AUC, 0.89), and IVA (AUC, 0.88). CONCLUSIONS: Motion-tracking Brillouin microscopy metrics effectively characterize focal corneal biomechanical alterations in eyes with SKC and clearly differentiated these eyes from control eyes, including eyes that were not differentiated accurately using Scheimpflug metrics. FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.


Assuntos
Ceratocone , Humanos , Ceratocone/diagnóstico , Topografia da Córnea/métodos , Microscopia , Estudos Transversais , Estudos Prospectivos , Paquimetria Corneana
12.
Biomacromolecules ; 25(2): 955-963, 2024 Feb 12.
Artigo em Inglês | MEDLINE | ID: mdl-38156622

RESUMO

Even though the physical nature of shear and longitudinal moduli are different, empirical correlations between them have been reported in several biological systems. This correlation is of fundamental interest and immense practical value in biomedicine due to the importance of the shear modulus and the possibility to map the longitudinal modulus at high-resolution with all-optical spectroscopy. We investigate the origin of such a correlation in hydrogels. We hypothesize that both moduli are influenced in the same direction by underlying physicochemical properties, which leads to the observed material-dependent correlation. Matching theoretical models with experimental data, we quantify the scenarios in which the correlation holds. For polymerized hydrogels, a correlation was found across different hydrogels through a common dependence on the effective polymer volume fraction. For hydrogels swollen to equilibrium, the correlation is valid only within a given hydrogel system, as the moduli are found to have different scalings on the swelling ratio. The observed correlation allows one to extract one modulus from another in relevant scenarios.


Assuntos
Hidrogéis , Polímeros , Hidrogéis/química , Polímeros/química , Análise Espectral , Modelos Teóricos , Viscosidade
13.
Bioengineering (Basel) ; 10(10)2023 Sep 22.
Artigo em Inglês | MEDLINE | ID: mdl-37892838

RESUMO

Over the last two decades, there has been growing interest in assessing corneal biomechanics in different diseases, such as keratoconus, glaucoma, and corneal disorders. Given the interaction and structural continuity between the cornea and sclera, evaluating corneal biomechanics may give us further insights into the pathogenesis, diagnosis, progression, and management of glaucoma. Therefore, some authorities have recommended baseline evaluations of corneal biomechanics in all glaucoma and glaucoma suspects patients. Currently, two devices (Ocular Response Analyzer and Corneal Visualization Schiempflug Technology) are commercially available for evaluating corneal biomechanics; however, each device reports different parameters, and there is a weak to moderate agreement between the reported parameters. Studies are further limited by the inclusion of glaucoma subjects taking topical prostaglandin analogues, which may alter corneal biomechanics and contribute to contradicting results, lack of proper stratification of patients, and misinterpretation of the results based on factors that are confounded by intraocular pressure changes. This review aims to summarize the recent evidence on corneal biomechanics in glaucoma patients and insights for future studies to address the current limitations of the literature studying corneal biomechanics.

14.
bioRxiv ; 2023 Aug 04.
Artigo em Inglês | MEDLINE | ID: mdl-37577618

RESUMO

The formation of the brain and spinal cord is initiated in the earliest stages of mammalian pregnancy in a highly organized process known as neurulation. Convergent and extension movements transforms a flat sheet of ectodermal cells into a narrow and elongated line of neuroepithelia, while a major source of Sonic Hedgehog signaling from the notochord induces the overlying neuroepithelial cells to form two apposed neural folds. Afterward, neural tube closure occurs by synchronized coordination of the surface ectoderm and adjacent neuroepithelial walls at specific axial regions known as neuropores. Environmental or genetic interferences can impair neurulation resulting in neural tube defects. The Fuz gene encodes a subunit of the CPLANE complex, which is a macromolecular planar polarity effector required for ciliogenesis. Ablation of Fuz in mouse embryos results in exencephaly and spina bifida, including dysmorphic craniofacial structures due to defective cilia formation and impaired Sonic Hedgehog signaling. In this work, we demonstrate that knocking Fuz out during embryonic mouse development results in a hypoplastic hindbrain phenotype, displaying abnormal rhombomeres with reduced length and width. This phenotype is associated with persistent loss of ventral neuroepithelial stiffness, in a notochord adjacent area at the level of the rhombomere 5, preceding the development of exencephaly in Fuz ablated mutants. The formation of cranial and paravertebral ganglia is also impaired in these embryos, indicating that Fuz has a critical function sustaining normal neural tube development and neuronal differentiation. SIGNIFICANCE STATEMENT: Neural tube defects (NTDs) are a common cause of disability in children, representing the second most common congenital structural malformation in humans following only congenital cardiovascular malformations. NTDs affect approximately 1 to 2 pregnancies per 1000 births every year worldwide, when the mechanical forces folding the neural plate fails to close at specific neuropores located anteriorly (cranial) or posteriorly (caudal) along the neural tube, in a process known as neurulation, which happens throughout the third and fourth weeks of human pregnancy.

16.
Nat Methods ; 20(5): 677-681, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36894684

RESUMO

Brillouin microscopy is a technique for mechanical characterization of biological material without contact at high three-dimensional resolution. Here, we introduce dual line-scanning Brillouin microscopy (dLSBM), which improves acquisition speed and reduces irradiation dose by more than one order of magnitude with selective illumination and single-shot analysis of hundreds of points along the incident beam axis. Using tumor spheroids, we demonstrate the ability to capture the sample response to rapid mechanical perturbations as well as the spatially resolved evolution of the mechanical properties in growing spheroids.


Assuntos
Iluminação , Neoplasias , Humanos , Microscopia Confocal/métodos
17.
Am J Ophthalmol ; 254: 128-140, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-36963605

RESUMO

PURPOSE: To characterize focal biomechanical differences between normal, keratoconic, and post-laser vision correction (LVC) corneas using motion-tracking Brillouin microscopy. DESIGN: Prospective cross-sectional study. METHODS: Thirty eyes from 30 patients (10 normal controls [Controls], 10 post-LVC, and 10 stage I or II keratoconus [KC]) had Scheimpflug and motion-tracking Brillouin microscopy imaging using a custom-built device. Mean, maximum (max) and minimum (min) Brillouin shift, spatial standard deviation, and max-min values were compared. Min values were correlated with local Brillouin values at multiple Scheimpflug imaging locations. RESULTS: Mean (P < .0003), min (P < .00001), spatial standard deviation (P < .01), and max-min (P < .001) were significantly different between the groups. In post hoc pairwise comparisons, the best differentiators for group comparisons were mean (P = .0004) and min (P = .000002) for Controls vs KC, min (P = .0022) and max-min (P = .002) for Controls vs LVC, and mean (P = .0037) and min (P = .0043) for LVC vs KC. Min (area under the receiver operating characteristic = 1.0) and mean (area under the receiver operating characteristic =  0.96) performed well in differentiating Control and KC eyes. Min values correlated best with Brillouin shift values at the thinnest corneal point (r2 = 0.871, P = .001) and maximum keratometry value identified in the tangential curvature map (r2 = 0.840, P = .002). CONCLUSIONS: Motion-tracking Brillouin microscopy effectively characterized focal corneal biomechanical alterations in LVC and KC and clearly differentiated these groups from Controls. Primary motion-tracking Brillouin metrics performed well in differentiating groups as compared with basic Scheimpflug metrics, in contrast to previous Brillouin studies, and identified focal changes after LVC where prior Brillouin studies did not.


Assuntos
Ceratocone , Microscopia , Humanos , Estudos Transversais , Estudos Prospectivos , Topografia da Córnea/métodos , Córnea , Ceratocone/diagnóstico , Ceratocone/cirurgia , Curva ROC , Lasers , Paquimetria Corneana
18.
Opt Express ; 31(3): 4334-4346, 2023 Jan 30.
Artigo em Inglês | MEDLINE | ID: mdl-36785404

RESUMO

Spectral imaging techniques extract spectral information using dispersive elements in combination with optical microscopes. For rapid acquisition, multiplexing spectral information along one dimension of imaged pixels has been demonstrated in hyperspectral imaging, as well as in Raman and Brillouin imaging. Full-field spectroscopy, i.e., multiplexing where imaged pixels are collected in 2D simultaneously while spectral analysis is performed sequentially, can increase spectral imaging speed, but so far has been attained at low spectral resolutions. Here, we extend 2D multiplexing to high spectral resolutions of ∼80 MHz (∼0.0001 nm) using high-throughput spectral discrimination based on atomic transitions.

19.
J Refract Surg ; 39(2): 78-88, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36779469

RESUMO

PURPOSE: To provide a comprehensive analysis of the most highly cited articles and authors in refractive surgery. METHODS: The Scopus database was searched for articles pertaining to refractive surgery using multiple search terms to identify the top 100 most cited articles in refractive surgery. A publicly available database of more than 100,000 scientists that provides standardized information on multiple variables resulting in a composite indicator (C score) was searched to identify refractive surgery authors. A refractive surgery-specific composite score was created using only the authors' publications that were directly related to refractive surgery. RESULTS: The 100 most cited articles and 40 refractive surgery authors with the highest ranked C score were identified. The article with the most citations by Trokel et al has garnered nearly 800 citations to date. All articles included in the top 100 had 200 or more citations. The peak publication years were 1998 to 2001. Laser in situ keratomileusis (22), photorefractive keratectomy (18), and postoperative corneal ectasia and/or corneal biomechanics (16) were the most represented topics. Emory University generated the most articles (7) and the majority of publications (48%) originated in the United States. Steven E. Wilson, MD, had the highest refractive C score and Jorge L. Alió, MD, PhD, had the most refractive surgery articles and citations. Among all authors listed, the average number of refractive surgery publications was 97, with 35% of the group having more than 100 refractive surgery articles published. All authors on the list had more than 2,000 citations for their refractive surgery articles, whereas 38% had 4,000 or more citations. CONCLUSIONS: This list provides a comprehensive assessment of the most cited articles and authors in refractive surgery and demonstrates key focuses and trends in the field over time. [J Refract Surg. 2023;39(2):78-88.].


Assuntos
Ceratomileuse Assistida por Excimer Laser In Situ , Oftalmologia , Ceratectomia Fotorrefrativa , Humanos , Estados Unidos , Bibliometria , Bases de Dados Factuais
20.
Sci Rep ; 13(1): 263, 2023 01 06.
Artigo em Inglês | MEDLINE | ID: mdl-36609620

RESUMO

Neural tube closure (NTC) is a complex process of embryonic development involving molecular, cellular, and biomechanical mechanisms. While the genetic factors and biochemical signaling have been extensively investigated, the role of tissue biomechanics remains mostly unexplored due to the lack of tools. Here, we developed an optical modality that can conduct time-lapse mechanical imaging of neural plate tissue as the embryo is experiencing neurulation. This technique is based on the combination of a confocal Brillouin microscope and a modified ex ovo culturing of chick embryo with an on-stage incubator. With this technique, for the first time, we captured the mechanical evolution of the neural plate tissue with live embryos. Specifically, we observed the continuous increase in tissue modulus of the neural plate during NTC for ex ovo cultured embryos, which is consistent with the data of in ovo culture as well as previous studies. Beyond that, we found that the increase in tissue modulus was highly correlated with the tissue thickening and bending. We foresee this non-contact and label-free technique opening new opportunities to understand the biomechanical mechanisms in embryonic development.


Assuntos
Microscopia , Neurulação , Animais , Feminino , Gravidez , Embrião de Galinha , Microscopia/métodos , Tubo Neural , Imagem com Lapso de Tempo , Desenvolvimento Embrionário
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...