Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Clin Chem Lab Med ; 57(2): 296-304, 2018 12 19.
Artigo em Inglês | MEDLINE | ID: mdl-30281512

RESUMO

Background We previously showed, in patients with diabetes, that >50% of monitoring tests for glycated haemoglobin (HbA1c) are outside recommended intervals and that this is linked to diabetes control. Here, we examined the effect of tests/year on achievement of commonly utilised HbA1c targets and on HbA1c changes over time. Methods Data on 20,690 adults with diabetes with a baseline HbA1c of >53 mmol/mol (7%) were extracted from Clinical Biochemistry Laboratory records at three UK hospitals. We examined the effect of HbA1c tests/year on (i) the probability of achieving targets of ≤53 mmol/mol (7%) and ≤48 mmol/mol (6.5%) in a year using multi-state modelling and (ii) the changes in mean HbA1c using a linear mixed-effects model. Results The probabilities of achieving ≤53 mmol/mol (7%) and ≤48 mmol/mol (6.5%) targets within 1 year were 0.20 (95% confidence interval: 0.19-0.21) and 0.10 (0.09-0.10), respectively. Compared with four tests/year, having one test or more than four tests/year were associated with lower likelihoods of achieving either target; two to three tests/year gave similar likelihoods to four tests/year. Mean HbA1c levels were higher in patients who had one test/year compared to those with four tests/year (mean difference: 2.64 mmol/mol [0.24%], p<0.001). Conclusions We showed that ≥80% of patients with suboptimal control are not achieving commonly recommended HbA1c targets within 1 year, highlighting the major challenge facing healthcare services. We also demonstrated that, although appropriate monitoring frequency is important, testing every 6 months is as effective as quarterly testing, supporting international recommendations. We suggest that the importance HbA1c monitoring frequency is being insufficiently recognised in diabetes management.


Assuntos
Diabetes Mellitus Tipo 2/sangue , Hemoglobinas Glicadas/análise , Adulto , Glicemia/análise , Feminino , Humanos , Masculino , Probabilidade
2.
Gerontol Geriatr Med ; 3: 2333721417697843, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28491910

RESUMO

Introduction: There is increasing evidence concerning adverse health consequences of low vitamin D levels. We determined whether there is any surrogate for measuring vitamin D in people older than 70 years and the relation between index of multiple deprivation (IMD) and vitamin D levels. Methods: Blood samples from 241 patients were included in this analysis. Concurrent measurements for 25-hydroxyvitamin D (25(OH)D), parathyroid hormone (PTH), and bone profile are reported. Results: The prevalence of total vitamin D insufficiency/deficiency (defined as total vitamin D <50 nmol/L) was 57.5% overall. Even for patients with vitamin D deficiency, a significant proportion had PTH, normal calcium, phosphate, and alkaline phosphatase levels. For patients with vitamin D <25 nmol/L, 62.7% had a PTH within reference range, 83.1% had normal serum-adjusted calcium, 80.6% had normal phosphate, and 85.1% had a normal serum alkaline phosphatase. With increasing quintiles of IMD, there was a 22% increased risk of vitamin D deficiency/insufficiency from quintiles 1 to 5, in age- and sex-adjusted logistic regression models (odds ratio [OR] = 1.22, 95% confidence interval [1.01, 1.47]; p = .034). Conclusion: No other parameter is currently adequate for screening for vitamin D deficiency in older people. A higher IMD is associated with lower vitamin D levels in older people.

3.
Exp Clin Endocrinol Diabetes ; 125(9): 625-633, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28407667

RESUMO

With demand for endocrine tests steadily increasing year-on-year, we examined thyroid function test (TFT) frequencies in patients on levothyroxine replacement therapy to assess the effect of initial TFT results and request source on TFT re-testing interval. All TFTs performed by the Clinical Biochemistry Departments at the Salford Royal Hospital (2009-2012; 288 263 requests from 139 793 patients) and University Hospital of North Midlands (2011-2014; 579 156 requests from 193 035 patients) were extracted from the laboratory computer systems. Of these, 54 894 tests were on 13 297 patients confirmed to be on levothyroxine therapy in the test cohort (Salford) and 67 298 requests on 11 971 patients in the confirmatory cohort (North Midlands). In the test cohort, median TFT re-testing interval in the total group was 19.1 weeks (IQR 9.1-37.7 weeks), with clearly defined peaks in TFT re-testing evident at 6 and 12 months and a prominent broad peak at 1-3 months. Median re-test interval was much lower than recommended (52 weeks) for those with normal TFTs at 31.3 weeks (30.6 weeks for the confirmatory cohort). Where thyroid-stimulating hormone (TSH) was elevated and free thyroxine (fT4) was below the reference range, re-test interval was much longer than is recommended (8 weeks) at 13.4-17.6 weeks (7.1-23.4 weeks in the confirmatory cohort), as was the interval when TSH was below and fT4 was above the normal range, at 16.7-25.6 weeks (27.5-31.9 weeks in the confirmatory cohort). Our findings show that the majority of TFT requests are requested outside recommended intervals and within-practice variability is high. A new approach to ensuring optimum monitoring frequency is required. Direct requesting from the clinical laboratory may provide one such solution.


Assuntos
Fidelidade a Diretrizes/estatística & dados numéricos , Hipotireoidismo/tratamento farmacológico , Monitorização Fisiológica/métodos , Monitorização Fisiológica/normas , Padrões de Prática Médica , Glândula Tireoide/fisiologia , Tiroxina/uso terapêutico , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Terapia de Reposição Hormonal , Humanos , Hipotireoidismo/diagnóstico , Hipotireoidismo/epidemiologia , Hipotireoidismo/fisiopatologia , Masculino , Pessoa de Meia-Idade , Monitorização Fisiológica/estatística & dados numéricos , Padrões de Prática Médica/normas , Padrões de Prática Médica/estatística & dados numéricos , Testes de Função Tireóidea/normas , Testes de Função Tireóidea/estatística & dados numéricos , Glândula Tireoide/efeitos dos fármacos , Adulto Jovem
5.
Diabetes Care ; 37(10): 2731-7, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25249670

RESUMO

OBJECTIVE: We previously showed that in patients with diabetes mellitus, glycated hemoglobin (HbA1c) monitoring outside international guidance on testing frequency is widespread. Here we examined the relationship between testing frequency and diabetes control to test the hypothesis that retest interval is linked to change in HbA1c level. RESEARCH DESIGN AND METHODS: We examined repeat HbA1c tests (400,497 tests in 79,409 patients, 2008-2011) processed by three U.K. clinical laboratories. We examined the relationship between retest interval and 1) percentage change in HbA1c and 2) proportion of cases showing a significant HbA1c rise. The effect of demographics factors on these findings was also explored. RESULTS: Our data showed that the optimal testing frequency required to maximize the downward trajectory in HbA1c was four times per year, particularly in those with an initial HbA1c of ≥7% (≥53 mmol/mol), supporting international guidance. Testing 3-monthly was associated with a 3.8% reduction in HbA1c compared with a 1.5% increase observed with annual testing; testing more frequently provided no additional benefit. Compared with annual monitoring, 3-monthly testing was associated with a halving of the proportion showing a significant rise in HbA1c (7-10 vs. 15-20%). CONCLUSIONS: These findings provide, in a large, multicenter data set, objective evidence that testing outside guidance on HbA1c monitoring frequency is associated with a significant detrimental effect on diabetes control. To achieve the optimum downward trajectory in HbA1c, monitoring frequency should be quarterly, particularly in cases with suboptimal HbA1c. While this impact appears small, optimizing monitoring frequency across the diabetes population may have major implications for diabetes control and comorbidity risk.


Assuntos
Diabetes Mellitus/sangue , Diabetes Mellitus/tratamento farmacológico , Hemoglobinas Glicadas/análise , Cooperação do Paciente/estatística & dados numéricos , Idoso , Automonitorização da Glicemia/estatística & dados numéricos , Comorbidade , Progressão da Doença , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Fisiológica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...