Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Br J Anaesth ; 77(5): 636-41, 1996 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-8957981

RESUMO

We have examined a new approach, using fuzzy logic, to the closed-loop feedback control of mechanical ventilation during general anaesthesia. This control system automatically adjusts ventilatory frequency (f) and tidal volume (VT) in order to achieve and maintain the end-tidal carbon dioxide fraction (FE'CO2) at a desired level (set-point). The controller attempts to minimize the deviation of both f and VT per kg body weight from 10 bpm and 10 ml kg-1, respectively, and to maintain the plateau airway pressure within suitable limits. In 30 patients, undergoing various surgical procedures, the fuzzy control mode was compared with human ventilation control. For a set-point of FE'CO2 = 4.5 vol% and during measurement periods of 20 min, accuracy, stability and breathing pattern did not differ significantly between fuzzy logic and manual ventilation control. After step-changes in the set-point of FE'CO2 from 4.5 to 5.5 vol% and vice versa, overshoot and rise time did not differ significantly between the two control modes. We conclude that to achieve and maintain a desired FE'CO2 during routine anaesthesia, fuzzy logic feedback control of mechanical ventilation is a reliable and safe mode of control.


Assuntos
Anestesia Geral , Dióxido de Carbono/fisiologia , Lógica Fuzzy , Respiração Artificial/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Dióxido de Carbono/sangue , Criança , Simulação por Computador , Retroalimentação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Oxigênio/sangue , Pressão Parcial
2.
J Chromatogr ; 143(2): 171-81, 1977 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-838829

RESUMO

A selective, sensitive and precise gas-liquid chromatographic method for the determination of diphenylhydantoin in micro samples of blood plasma is described. After a double extraction with chloroform containing an analogue of diphenylhydantoin as an internal standard, the drug and standard are N,N-dimethylated in alkaline aqueous solution with methyl iodide followed by extraction into acetone. The methylated derivatives are separated gas chromatographically and measured using a flame-ionization detector. The lowest concentration of diphenylhydantoin in plasma which can be measured in a 100 mul sample is 1 mug/ml, which is well below the normal therapeutic concentration of 10-20 mug/ml in plasma. The methylated derivatives of diphenylhydantoin and the internal standard have been identified by their proton magnetic resonance spectra and mass spectra.


Assuntos
Cromatografia Gasosa , Fenitoína/sangue , Cromatografia Líquida , Espectroscopia de Ressonância Magnética , Espectrometria de Massas , Metilação , Microquímica , Solventes
3.
J Chromatogr ; 118(3): 363-70, 1976 Apr 07.
Artigo em Inglês | MEDLINE | ID: mdl-3515

RESUMO

A gas-liquid chromatographic method for the quantitative determination of phanquone is described, based on the formation of a dimethoxine prior to its extraction from biological material. The sensitivity of the procedure is about 15 ng/ml in biological fluid.


Assuntos
Cromatografia Gasosa , Fenantrolinas/análise , Adulto , Fenômenos Químicos , Química , Cromatografia Líquida , Humanos , Concentração de Íons de Hidrogênio , Isomerismo , Métodos , Pessoa de Meia-Idade , Oximas , Fenantrolinas/sangue , Fenantrolinas/urina
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...