1.
J Biomed Mater Res B Appl Biomater ; 86(2): 407-16, 2008 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-18161779

RESUMO

Stem modularity in total hip replacement introduces an additional taper joint between Ti-6Al-4V stem components with the potential for fretting corrosion processes. One possible way to reduce the susceptibility of the Ti-6Al-4V/Ti-6Al-4V interface to fretting is the surface modification of the Ti-6Al-4V alloy. Among the tested, industrially available surface treatments, a combination of two deep anodic spark deposition treatments followed by barrel polishing resulted in a four times lower material release with respect to untreated, machined fretting pad surfaces. The fretting release has been quantified by means of radiotracers introduced in the alloy surface by proton irradiation. In a simple sphere on flat geometry, the semispherical fretting pads were pressed against flat, dog-bone shaped Ti-6Al-4V fatigue samples cyclically loaded at 4 Hz. In this way a cyclic displacement amplitude along the surfaces of 20 mum has been achieved. A further simplification consisted in the use of deionized water as lubricant. A comparison of the radiotracer results with an electrochemical material characterization after selected treatments by potentiostatic tests of modular stems in 0.9% NaCl at 40 degrees C for 10 days confirmed the benefit of deep anodic spark deposition and subsequent barrel polishing for improving the fretting behavior of Ti-6Al-4V.


Assuntos
Ligas/química , Materiais Biocompatíveis/química , Alumínio , Propriedades de Superfície , Titânio , Vitálio
2.
J Biomed Mater Res B Appl Biomater ; 77(1): 79-88, 2006 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-16211570

RESUMO

A piezo-electrically driven fretting testing device has been constructed and fretting release and release rates have been determined with highest accuracy, using a radiotracer technique. First results on the fretting release and release rate of titanium alloy fretting pads against cobalt-chrome alloy fatigue specimens are reported. The frequency dependency of fretting release has been determined between 1 and 8 Hz and shows higher release rates for low frequencies, thus indicating that accelerated testing of materials and components of artificial joints must be analyzed extremely carefully. The present experiments under simple conditions present a base-line study for step-wise applying more complex and realistic testing conditions and for using radiotracer methods to quantify fretting release in simulated testing of artificial hip- and knee-prostheses.


Assuntos
Prótese Articular , Teste de Materiais , Titânio/química , Vitálio/química , Ligas , Animais , Materiais Biocompatíveis/química , Dureza , Humanos , Teste de Materiais/instrumentação , Teste de Materiais/métodos , Desenho de Prótese , Falha de Prótese , Radioisótopos/química , Estresse Mecânico , Propriedades de Superfície