Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Clin Imaging ; 41: 118-124, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-27840263

RESUMO

PURPOSE: The purpose was to assess image quality of portal-venous phase dual-energy computed tomography (DECT) for liver lesions. METHODS: We performed 120-kVp-equivalent linear-blended (LB) and monoenergetic reconstructions from 40 to 190 keV by standard (VMI) and advanced virtual monoenergetic (VMI+) methods. Diagnostic performance, and quantitative and qualitative image analyses were assessed and compared. RESULTS: Liver contrast to noise ratio peaked at 40 keV_VMI+, while image quality and reader preference peaked at 50 keV_VMI+. 50 keV_VMI+ scored overall higher diagnostic performance: lesion sensitivity 95.4% vs. 83.3% for both 75 keV_VMI and LB. CONCLUSIONS: DECT improves assessment of hypoenhancing liver lesions on portal venous phase. 50 keV_VMI+ demonstrated the highest image quality and diagnostic performance over VMI and LB.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Neoplasias Hepáticas/diagnóstico por imagem , Veia Porta/diagnóstico por imagem , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Feminino , Humanos , Fígado/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Razão Sinal-Ruído
2.
Eur J Radiol ; 85(4): 695-9, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26971410

RESUMO

OBJECTIVES: To evaluate optimal window settings for display of virtual monoenergetic reconstructions in third-generation dual-source, dual-energy computed tomography (DECT) of the liver. METHODS: Twenty-nine subjects were prospectively evaluated with DECT in arterial (AP) and portal venous (PVP) phases. Three reconstructed datasets were calculated: standard linearly-blended (LB120), 70-keV standard virtual monoenergetic (M70), and 50-keV advanced image-based virtual monoenergetic (M50+). Two readers assessed optimal window settings (width and level, W/L), establishing a mean for each reconstruction which was used for a blinded assessment of liver lesions. RESULTS: The optimal W/L for M50+ were significantly higher for both AP (W=429.3 ± 44.6 HU, L=129.4 ± 9.7 HU) and PVP (W=376.1 ± 14.2HU, L=146.6 ± 7.0 HU) than for LB120 (AP, W=215.9 ± 16.9 HU, L=82.3 ± 9.4 HU) (PVP, W=173.4 ± 8.9 HU, L=69.3 ± 6.0 HU) and M70 (AP, W=247.1 ± 22.2 HU, L=72.9 ± 6.8 HU) (PVP, W=232.0 ± 27.9 HU, L=91.6 ± 14.4 HU). Use of the optimal window setting for M50+ vs. LB120 resulted in higher sensitivity (AP, 100% vs. 86%; PVP, 96% vs. 63%). CONCLUSIONS: Application of dedicated window settings results in improved liver lesion detection rates in advanced image-based virtual monoenergetic DECT when customized for arterial and portal venous phases.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Neoplasias Hepáticas/diagnóstico por imagem , Fígado/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Estudos Prospectivos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
3.
Breast J ; 21(4): 395-402, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25864435

RESUMO

The purpose of this study is to characterize sternal lesions detected on breast magnetic resonance imaging (MRI), compare MRI detection of sternal lesions with other imaging modalities (bone scan, positron emission tomography/computed tomography (PET/CT) and chest CT), and ascertain how often patient management is altered by discovery of sternal lesions. Retrospective review of 1143 breast MRIs between 2007 and 2012 identified 17 patients with sternal lesions including 15 patients with newly diagnosed breast cancer and two patients with remote history of breast cancer. Tumor size, histopathology, receptor status, nodal and distant metastasis, and images of breast MRI, and other modalities were reviewed. Sternal lesions in 9 of the 17 patients were determined to be malignant (metastasis) either by biopsy or presence of widespread metastases. Sternal lesions in 8 of the 17 were benign, confirmed by biopsy or presumed benign as not detected by other modalities. The malignant group had statistically significant larger breast cancer size (malignant: 6.4 cm; benign: 2.3 cm), a higher percentage of diffuse sternal lesions (malignant: 56%; benign: 0%), and more frequently showed rapid initial enhancing (malignant: 100%; benign: 63%) and delayed washout curves (malignant: 67%; benign: 13%). Although not statistically significant, the malignant group had a higher frequency of invasive lobular carcinoma (malignant: 44%; benign: 13%) and more lymph node involvement (malignant: 78%; benign: 50%). Breast MRI detected more sternal lesions than did bone scan, PET/CT and chest CT. Four of the 17 (24%) patients were upgraded to stage 4 due to unsuspected metastatic sternal lesions on breast MRI. In conclusion, breast MRI is more sensitive than other modalities in detecting sternal lesions. Sternal metastases occur more frequently in aggressive breast cancer and exhibit malignant-type dynamics on breast MRI. Detection of unsuspected sternal metastasis alters staging and improves patient management with more appropriate treatment.


Assuntos
Neoplasias Ósseas/diagnóstico , Neoplasias Ósseas/secundário , Neoplasias da Mama/diagnóstico , Neoplasias da Mama/patologia , Esterno/patologia , Adulto , Neoplasias Ósseas/diagnóstico por imagem , Neoplasias da Mama/diagnóstico por imagem , Feminino , Humanos , Imageamento por Ressonância Magnética , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Radiografia , Estudos Retrospectivos , Ultrassonografia
4.
ScientificWorldJournal ; 2013: 678156, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23533356

RESUMO

The amnion is a specialized tissue in contact with the amniotic fluid, which is in a constantly changing state. To investigate the importance of epigenetic events in this tissue in the physiology and pathophysiology of pregnancy, we performed genome-wide DNA methylation profiling of human amnion from term (with and without labor) and preterm deliveries. Using the Illumina Infinium HumanMethylation27 BeadChip, we identified genes exhibiting differential methylation associated with normal labor and preterm birth. Functional analysis of the differentially methylated genes revealed biologically relevant enriched gene sets. Bisulfite sequencing analysis of the promoter region of the oxytocin receptor (OXTR) gene detected two CpG dinucleotides showing significant methylation differences among the three groups of samples. Hypermethylation of the CpG island of the solute carrier family 30 member 3 (SLC30A3) gene in preterm amnion was confirmed by methylation-specific PCR. This work provides preliminary evidence that DNA methylation changes in the amnion may be at least partially involved in the physiological process of labor and the etiology of preterm birth and suggests that DNA methylation profiles, in combination with other biological data, may provide valuable insight into the mechanisms underlying normal and pathological pregnancies.


Assuntos
Âmnio/citologia , Metilação de DNA , Estudos de Associação Genética/métodos , Proteínas de Transporte de Cátions/genética , Ilhas de CpG , Epigênese Genética , Feminino , Perfilação da Expressão Gênica , Loci Gênicos , Idade Gestacional , Humanos , Recém-Nascido , Trabalho de Parto/genética , Trabalho de Parto/fisiologia , Análise de Sequência com Séries de Oligonucleotídeos , Placenta/citologia , Gravidez , Nascimento Prematuro/genética , Nascimento Prematuro/fisiopatologia , Análise de Componente Principal , Regiões Promotoras Genéticas , Receptores de Ocitocina/genética
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...