Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Front Neurosci ; 16: 976594, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36570841

RESUMO

Motion capture systems are widely accepted as ground-truth for gait analysis and are used for the validation of other gait analysis systems. To date, their reliability and limitations in manual labeling of gait events have not been studied. Objectives: Evaluate manual labeling uncertainty and introduce a hybrid stride detection and gait-event estimation model for autonomous, long-term, and remote monitoring. Methods: Estimate inter-labeler inconsistencies by computing the limits-of-agreement. Develop a hybrid model based on dynamic time warping and convolutional neural network to identify valid strides and eliminate non-stride data in inertial (walking) data collected by a wearable device. Finally, detect gait events within a valid stride region. Results: The limits of inter-labeler agreement for key gait events heel off, toe off, heel strike, and flat foot are 72, 16, 24, and 80 ms, respectively; The hybrid model's classification accuracy for stride and non-stride are 95.16 and 84.48%, respectively; The mean absolute error for detected heel off, toe off, heel strike, and flat foot are 24, 5, 9, and 13 ms, respectively, when compared to the average human labels. Conclusions: The results show the inherent labeling uncertainty and the limits of human gait labeling of motion capture data; The proposed hybrid-model's performance is comparable to that of human labelers, and it is a valid model to reliably detect strides and estimate the gait events in human gait data. Significance: This work establishes the foundation for fully automated human gait analysis systems with performances comparable to human-labelers.

2.
Artigo em Inglês | MEDLINE | ID: mdl-37015703

RESUMO

Detecting gait phases with wearables unobtrusively and reliably in real-time is important for clinical gait rehabilitation and early diagnosis of neurological diseases. Due to hardware limitations of microcontrollers in wearable devices (e.g., memory and computation power), reliable real-time gait phase detection on the microcontrollers remains a challenge, especially for long-term real-world free-living gait. In this work, a novel algorithm based on a reduced support vector machine (RSVM) and a finite state machine (FSM) is developed to address this. The RSVM is developed by exploiting the cascaded K-means clustering to reduce the model size and computation time of a standard SVM by 88% and a factor of 36, with only minor degradation in gait phase prediction accuracy of around 4%. For each gait phase prediction from the RSVM, the FSM is designed to validate the prediction and correct misclassifications. The developed algorithm is implemented on a microcontroller of a wearable device and its real-time (on the fly) classification performance is evaluated by twenty healthy subjects walking along a predefined real-world route with uncontrolled free-living gait. It shows a promising real-time performance with an accuracy of 91.51%, a sensitivity of 91.70%, and a specificity of 95.77%. The algorithm also demonstrates its robustness with varying walking conditions.

3.
Sensors (Basel) ; 21(23)2021 Dec 04.
Artigo em Inglês | MEDLINE | ID: mdl-34884118

RESUMO

We present a system capable of providing visual feedback for ergometer training, allowing detailed analysis and gamification. The presented solution can easily upgrade any existing ergometer device. The system consists of a set of pedals with embedded sensors, readout electronics and wireless communication modules and a tablet device for interaction with the users, which can be mounted on any ergometer, transforming it into a full analytical assessment tool with interactive training capabilities. The methods to capture the forces and moments applied to the pedal, as well as the pedal's angular position, were validated using reference sensors and high-speed video capture systems. The mean-absolute error (MAE) for load is found to be 18.82 N, 25.35 N, 0.153 Nm for Fx, Fz and Mx respectively and the MAE for the pedal angle is 13.2°. A fully gamified experience of ergometer training has been demonstrated with the presented system to enhance the rehabilitation experience with audio visual feedback, based on measured cycling parameters.


Assuntos
, Gamificação , Ciclismo , Gravitação
4.
Sensors (Basel) ; 21(8)2021 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-33921846

RESUMO

The deterioration of gait can be used as a biomarker for ageing and neurological diseases. Continuous gait monitoring and analysis are essential for early deficit detection and personalized rehabilitation. The use of mobile and wearable inertial sensor systems for gait monitoring and analysis have been well explored with promising results in the literature. However, most of these studies focus on technologies for the assessment of gait characteristics, few of them have considered the data acquisition bandwidth of the sensing system. Inadequate sampling frequency will sacrifice signal fidelity, thus leading to an inaccurate estimation especially for spatial gait parameters. In this work, we developed an inertial sensor based in-shoe gait analysis system for real-time gait monitoring and investigated the optimal sampling frequency to capture all the information on walking patterns. An exploratory validation study was performed using an optical motion capture system on four healthy adult subjects, where each person underwent five walking sessions, giving a total of 20 sessions. Percentage mean absolute errors (MAE%) obtained in stride time, stride length, stride velocity, and cadence while walking were 1.19%, 1.68%, 2.08%, and 1.23%, respectively. In addition, an eigenanalysis based graphical descriptor from raw gait cycle signals was proposed as a new gait metric that can be quantified by principal component analysis to differentiate gait patterns, which has great potential to be used as a powerful analytical tool for gait disorder diagnostics.


Assuntos
Análise da Marcha , Sapatos , Adulto , Envelhecimento , Marcha , Humanos , Caminhada
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...