Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Vet Immunol Immunopathol ; 125(1-2): 126-34, 2008 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-18573542

RESUMO

Horse IL-7 (HIL-7) cDNA was isolated from adult lymph node tissue by reverse transcription polymerase chain reaction (RT-PCR) using oligonucleotide primers based on horse genomic sequences (The Broad Institute). In addition, to the full-length (FL) 531bp reading frame encoding 176 amino acids, shorter open-reading frames of 477, 396 and 264bp were also amplified. Nucleotide sequence analysis of these RT-PCR products demonstrated they were homologous except the shorter species were missing internal sequences consistent with multiple RNA splicing events. Consequently, the shorter open-reading frames were re-named splice variant (SV) 1 (477bp), 2 (396bp) and 3 (264bp). Organization of the horse IL-7 is predicted to be similar to that in humans with exon 5 deleted from SV1, exons 3, 5 deleted from SV2 and exons 3, 4, and 5 missing from SV3. Each of these open-reading frames has the potential to be stably expressed as demonstrated using a polyclonal antiserum against human IL-7 to visualize the protein products produced when the FL HIL-7 and each SV were molecularly cloned into pCI and transfected in brefeldin A treated HEK 293 cells. Furthermore, addition of supernatants to horse PBMC from HEK cells transfected (without brefeldin A treatment) with pCI HIL-7 FL, pCI HIL-7SV1, pCI HIL-7SV2 and pCI IL-7SV3 all induced significant incorporation of (3)H-thymidine in the presence of sub-stimulatory amounts of concanavalin A compared to supernatants from mock-transfected cells. Therefore, all isoforms of horse IL-7 described in this report have the ability to stimulate proliferative responses in ex vivo horse PBMC cultures.


Assuntos
Cavalos/genética , Interleucina-7/genética , Linfonodos/imunologia , Sequência de Aminoácidos , Animais , Proliferação de Células/efeitos dos fármacos , Clonagem Molecular , DNA Complementar/genética , Cavalos/imunologia , Interleucina-7/biossíntese , Interleucina-7/imunologia , Leucócitos Mononucleares/imunologia , Dados de Sequência Molecular , Isoformas de Proteínas , RNA/química , RNA/genética , Reação em Cadeia da Polimerase Via Transcriptase Reversa/veterinária , Alinhamento de Sequência , Transfecção/veterinária
3.
Spine (Phila Pa 1976) ; 33(12): E378-85, 2008 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-18496333

RESUMO

STUDY DESIGN: Thoracic pedicle screw location and the current needed to stimulate adjacent neural tissue was evaluated using brief, high-frequency pulse trains and monitoring electromyography (EMG) from muscles in the lower limbs. OBJECTIVE: To establish a safe and reliable method for detecting medial malpositioning of pedicle screws placed in the thoracic spine during instrumentation and fusion. SUMMARY OF BACKGROUND DATA: Neurophysiologic studies for testing thoracic pedicle screw placement used single-pulse stimulation and monitored EMG from thoracic-innervated muscles. We propose that with this approach, stimulation fails to activate lower motor neurons innervated by spinal cord axons, such that medial malplacement of screws will go largely undetected. METHODS: EMG was monitored from multiple lower-limb muscles. Pedicle tracks were created free-hand, using a curved pedicle finder. A ball-tipped probe-insulated along its shaft-was used to palpate the walls of the pedicle tracks. During probing, constant-current, high-frequency 4-pulse stimulus trains were delivered through the ball tip, and the minimum current (i.e., threshold) needed to evoke EMG was determined for each pedicle track. The threshold current for stimulation through each screw was also determined. Postoperative serial computed tomography scans of all implanted thoracic and L1 screws were rated with respect to screw position and the pedicle wall. RESULTS: A total of 116 screws were implanted in 7 subjects. Two pedicle tracks were redirected during surgery because of particularly low thresholds to stimulation. Definite medial defects were found in 19 screws, 18 of which were detected by the experimental technique. For these screws, the average threshold to probe stimulation of their associated pedicle tracks was 7.9 +/- 4.6 mA, much lower than current thresholds for less medially placed pedicle tracks. Stimulation of these screws resulted in high thresholds (19.8 +/- 5.3 mA) when a response was evoked at all; stimulating 8 of these 19 medially malpositioned screws failed to elicit any lower-limb EMG at considerably higher (25 or 30 mA) stimulus intensities. CONCLUSION: This preliminary study supports the hypothesis that high-frequency stimulus pulse trains areeffective at detecting defects in the medial wall of pedicles in the thoracic spine during instrumentation, thereby improving on techniques using single-pulse stimulus protocols.


Assuntos
Parafusos Ósseos , Estimulação Elétrica , Cifose/cirurgia , Monitorização Intraoperatória/métodos , Escoliose/cirurgia , Fusão Vertebral/instrumentação , Vértebras Torácicas/cirurgia , Adulto , Eletromiografia , Potenciais Somatossensoriais Evocados , Feminino , Humanos , Cifose/diagnóstico por imagem , Cifose/fisiopatologia , Masculino , Pessoa de Meia-Idade , Músculo Esquelético/inervação , Projetos Piloto , Escoliose/diagnóstico por imagem , Escoliose/fisiopatologia , Limiar Sensorial , Fusão Vertebral/efeitos adversos , Nervos Torácicos/fisiopatologia , Vértebras Torácicas/diagnóstico por imagem , Vértebras Torácicas/fisiopatologia , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA