1.
Biomicrofluidics ; 6(1): 12804-128049, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22662072

RESUMO

Clinical point of care testing often needs plasma instead of whole blood. As centrifugation is labor intensive and not always accessible, filtration is a more appropriate separation technique. The complexity of whole blood is such that there is still no commercially available filtration system capable of separating small sample volumes (10-100 µl) at the point of care. The microfluidics research in blood filtration is very active but to date nobody has validated a low cost device that simultaneously filtrates small samples of whole blood and reproducibly recovers clinically relevant biomarkers, and all this in a limited amount of time with undiluted raw samples. In this paper, we show first that plasma filtration from undiluted whole blood is feasible and reproducible in a low-cost microfluidic device. This novel microfluidic blood filtration element (BFE) extracts 12 µl of plasma from 100 µl of whole blood in less than 10 min. Then, we demonstrate that our device is valid for clinical studies by measuring the adsorption of interleukins through our system. This adsorption is reproducible for interleukins IL6, IL8, and IL10 but not for TNFα. Hence, our BFE is valid for clinical diagnostics with simple calibration prior to performing any measurement.

2.
Diabetes Res Clin Pract ; 97(1): 112-8, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22402305

RESUMO

Continuous subcutaneous glucose monitoring has been tested in type 1 diabetes (T1D). Since in critically ill patients vascular access is granted vascular microdialysis may be preferential. To test this hypothesis comparative accuracy data for microdialysis applied for peripheral venous and subcutaneous glucose monitoring was obtained in experiments in T1D patients. Twelve T1D patients were investigated for up to 30 h. Extracorporeal vascular (MDv) and subcutaneous microdialysis (MDs) was performed. Microdialysis samples were collected in 15-60 min intervals, analyzed for glucose and calibrated to reference. MDv and MDs glucose levels were compared against reference. Median absolute relative difference was 14.0 (5.0; 28.0)% (MDv) and 9.2 (4.4; 18.4)% (MDs). Clarke Error Grid analysis showed that 100% (MDv) and 98.8% (MDv) were within zones A and B. Extracorporeal vascular and standard subcutaneous microdialysis indicated similar performance in T1D. We suggest microdialysis as a versatile technology for metabolite monitoring in subcutaneous tissue and whole blood.


Assuntos
Glicemia/metabolismo , Estado Terminal , Diabetes Mellitus Tipo 1/sangue , Microdiálise , Monitorização Fisiológica/métodos , Tela Subcutânea/metabolismo , Adulto , Calibragem , Diabetes Mellitus Tipo 1/fisiopatologia , Feminino , Humanos , Masculino , Microdiálise/métodos , Microdiálise/tendências , Monitorização Fisiológica/tendências , Valores de Referência , Reprodutibilidade dos Testes , Tela Subcutânea/fisiopatologia , Fatores de Tempo
3.
J Diabetes Sci Technol ; 5(4): 901-5, 2011 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-21880232

RESUMO

BACKGROUND: Glycemic control can reduce the mortality and morbidity of intensive care patients. The CLINICIP (closed-loop insulin infusion for critically ill patients) project aimed to develop a closed-loop control system for this patient group. Following a stepwise approach, we combined three independently tested subparts to form a semiautomatic closed-loop system and evaluated it with respect to safety and performance aspects by testing it in subjects with type 1 diabetes mellitus (T1DM) in a first feasibility trial. METHODS: Vascular microdialysis, a multianalyte infrared spectroscopic glucose sensor, and a standard insulin infusion pump controlled by an adaptive model predictive control (MPC) algorithm were combined to form a closed-loop device, which was evaluated in four T1DM subjects during 30-hour feasibility studies. The aim was to maintain blood glucose concentration in the target range between 80 and 110 mg/dl. RESULTS: Mean plasma glucose concentration was 110.5 ± 29.7 mg/dl. The MPC managed to establish normoglycemia within 105 ± 78 minutes after trial start and managed to maintain glucose concentration within the target range for 47% of the time. The hyperglycemic index averaged to 11.9 ± 5.3 mg/dl. CONCLUSION: Data of the feasibility trial illustrate the device being effective in controlling glycemia in T1DM subjects. However, the monitoring part of the loop must be improved with respect to accuracy and precision before testing the system in the target population.


Assuntos
Algoritmos , Análise Química do Sangue/métodos , Glicemia/análise , Diabetes Mellitus Tipo 1/sangue , Unidades de Terapia Intensiva , Microdiálise/métodos , Monitorização Fisiológica/métodos , Adulto , Técnicas Biossensoriais/instrumentação , Técnicas Biossensoriais/métodos , Análise Química do Sangue/instrumentação , Glicemia/metabolismo , Vasos Sanguíneos/química , Diabetes Mellitus Tipo 1/diagnóstico , Diabetes Mellitus Tipo 1/tratamento farmacológico , Estudos de Viabilidade , Feminino , Humanos , Hipoglicemiantes/administração & dosagem , Insulina/administração & dosagem , Sistemas de Infusão de Insulina , Masculino , Microdiálise/estatística & dados numéricos , Pessoa de Meia-Idade , Modelos Estatísticos , Monitorização Fisiológica/instrumentação , Prognóstico , Espectrofotometria Infravermelho , Adulto Jovem
4.
Diabetes Technol Ther ; 13(2): 127-34, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21284479

RESUMO

OBJECTIVE: This study evaluated the predictive capability of simple linear extrapolation of continuous glucose data in postsurgical patients undergoing intensive care. METHODS: Twenty patients, both with or without an established diagnosis of diabetes mellitus, scheduled to undergo cardiothoracic surgery were included. Glucose was continuously monitored in the intensive care unit with a microdialysis-based subcutaneous glucose monitoring system. The prediction horizon (PH) with respect to a given glucose reading was calculated by extrapolating the linear trend of the glucose signal and subjected to both analytical and clinical assessment (by calculation of the average duration of consecutive positive and negative glucose signal trends, the root mean squared error [RMSE], and by insulin titration error grid [ITEG] analysis, respectively). RESULTS: In total, 609 h of continuous glucose data from 17 patients were analyzed. The average duration of consecutive positive and negative glucose signal trends was 7.97 (3.99-19.98) min (median, interquartile range). An increase in the RMSE of 0.5 mmol/L (9 mg/dL) was associated with a PH of 37 min. A strong increase in the number of data points in the unacceptable violation zone of the ITEG was associated with a PH of approximately 20 min. CONCLUSIONS: Our data provide evidence that simple linear extrapolation of glucose trend information obtained by continuous glucose monitoring can be used to predict the course of glycemia in critically ill patients for up to 20-30 min. This "glimpse into the future" can be used to proactively prevent the occurrence of adverse events.


Assuntos
Glicemia/análise , Microdiálise , Modelos Biológicos , Monitorização Fisiológica , Complicações Pós-Operatórias/prevenção & controle , Procedimentos Cirúrgicos Torácicos/efeitos adversos , Idoso , Índice de Massa Corporal , Diabetes Mellitus/sangue , Diabetes Mellitus/tratamento farmacológico , Feminino , Humanos , Hiperglicemia/prevenção & controle , Hipoglicemia/prevenção & controle , Hipoglicemiantes/administração & dosagem , Hipoglicemiantes/uso terapêutico , Insulina/administração & dosagem , Insulina/uso terapêutico , Unidades de Terapia Intensiva , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/sangue , Fatores de Tempo
5.
Diabetes Care ; 33(4): 833-8, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20097778

RESUMO

OBJECTIVE: To examine insulin's effect on the tissue glucose concentration at the site of subcutaneous insulin administration. RESEARCH DESIGN AND METHODS: A CMA-60 microdialysis (MD) catheter and a 24-gauge microperfusion (MP) catheter were inserted into the subcutaneous adipose tissue of fasting, healthy subjects (n = 5). Both catheters were perfused with regular human insulin (100 units/ml) over a 6-h period and used for glucose sampling and simultaneous administration of insulin at sequential rates of 0.33, 0.66, and 1.00 units/h (each rate was used for 2 h). Before and after the insulin delivery period, both catheters were perfused with an insulin-free solution (5% mannitol) for 2 h and used for glucose sampling only. Blood plasma glucose was clamped at euglycemic levels during insulin delivery. RESULTS: Start of insulin delivery with MD and MP catheters resulted in a decline of the tissue glucose concentration and the tissue-to-plasma glucose ratio (TPR) for approximately 60 min (P < 0.05). However, during the rest of the 6-h period of variable insulin delivery, tissue glucose concentration paralleled the plasma glucose concentration, and the TPR for MD and MP catheters remained unchanged at 83.2 +/- 3.1 and 77.1 +/- 4.8%, respectively. After subsequent switch to insulin-free perfusate, tissue glucose concentration and TPR increased slowly and reattained preinsulin delivery levels by the end of the experiments. CONCLUSIONS: The results show the attainment of a stable TPR value at the site of insulin administration, thus indicating that insulin delivery and glucose sensing may be performed simultaneously at the same adipose tissue site.


Assuntos
Glicemia/efeitos dos fármacos , Glucose/metabolismo , Hipoglicemiantes/administração & dosagem , Insulina/administração & dosagem , Tela Subcutânea/metabolismo , Adulto , Humanos , Hipoglicemiantes/farmacologia , Infusões Subcutâneas , Insulina/farmacologia , Masculino , Modelos Teóricos
6.
Biomed Microdevices ; 12(3): 399-407, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-20101469

RESUMO

Glycemic control of intensive care patients can be beneficial for this patient group but the continuous determination of their glucose concentration is challenging. Current continuous glucose monitoring systems based on the measurement of interstitial fluid glucose concentration struggle with sensitivity losses, resulting from biofouling or inflammation reactions. Their use as decision support systems for the therapeutic treatment is moreover hampered by physiological time delays as well as gradients in glucose concentration between plasma and interstitial fluid. To overcome these drawbacks, we developed and clinically evaluated a system based on microdialysis of whole blood. Venous blood is heparinised at the tip of a double lumen catheter and pumped through a membrane based micro-fluidic device where protein-free microdialysate samples are extracted. Glucose recovery as an indicator of long term stability was studied in vitro with heparinised bovine blood and remained highly stable for 72 h. Clinical performance was tested in a clinical trial in eight healthy volunteers undergoing an oral glucose tolerance test. Glucose concentrations of the new system and the reference method correlated at a level of 0.96 and their mean relative difference was 1.9 +/- 11.2%. Clinical evaluation using Clark's Error Grid analysis revealed that the obtained glucose concentrations were accurate and clinically acceptable in 99.6% of all cases. In conclusion, results of the technical and clinical evaluation suggest that the presented device delivers microdialysate samples suitable for accurate and long term stable continuous glucose monitoring in blood.


Assuntos
Técnicas Biossensoriais/instrumentação , Glicemia/análise , Microdiálise/instrumentação , Monitorização Fisiológica/instrumentação , Adulto , Desenho de Equipamento , Análise de Falha de Equipamento , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
7.
Diabetes Care ; 33(3): 595-601, 2010 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-20040654

RESUMO

OBJECTIVE To simplify and improve the treatment of patients with type 1 diabetes, we ascertained whether the site of subcutaneous insulin infusion can be used for the measurement of glucose. RESEARCH DESIGN AND METHODS Three special indwelling catheters (24-gauge microperfusion [MP] catheters) were inserted into the subcutaneous adipose tissue of subjects with type 1 diabetes (n = 10; all C-peptide negative). One MP catheter was perfused with short-acting insulin (100 units/ml, Aspart) and used for insulin delivery and simultaneous glucose sampling during an overnight fast and after ingestion of a standard glucose load (75 g). As controls, the further two MP catheters were perfused with an insulin-free solution (5% mannitol) and used for glucose sampling only. Plasma glucose was measured frequently at the bedside. RESULTS Insulin delivery with the MP catheter was adequate to achieve and maintain normoglycemia during fasting and after glucose ingestion. Tissue glucose concentrations derived with the insulin-perfused catheter agreed well with plasma glucose levels. Median correlation coefficient and median absolute relative difference values were found to be 0.93 (interquartile range 0.91-0.97) and 10.9%, respectively. Error grid analysis indicated that the percentage number of tissue values falling in the clinically acceptable range is 99.6%. Comparable analysis results were obtained for the two mannitol-perfused catheters. CONCLUSIONS Our data suggest that estimation of plasma glucose concentrations from the glucose levels directly observed at the site of subcutaneous insulin infusion is feasible and its quality is comparable to that of estimating plasma glucose concentrations from glucose levels measured in insulin-unexposed subcutaneous tissue.


Assuntos
Glicemia/análise , Coleta de Amostras Sanguíneas/métodos , Diabetes Mellitus Tipo 1/sangue , Diabetes Mellitus Tipo 1/tratamento farmacológico , Insulina/administração & dosagem , Adulto , Coleta de Amostras Sanguíneas/instrumentação , Cateteres de Demora , Diabetes Mellitus Tipo 1/diagnóstico , Técnicas de Diagnóstico Endócrino/instrumentação , Estudos de Viabilidade , Feminino , Humanos , Bombas de Infusão , Infusões Subcutâneas , Masculino , Modelos Biológicos , Prognóstico , Fatores de Tempo
8.
J Diabetes Sci Technol ; 3(1): 110-6, 2009 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-20046655

RESUMO

BACKGROUND: Intensive insulin therapy reduces mortality and morbidity in critically ill patients but places great demands on medical staff who must take frequent blood samples for the determination of glucose levels. A cost-effective solution to this resourcing problem could be provided by an effective and reliable automated blood sampling (ABS) system suitable for ex vivo glucose determination. METHOD: The primary study aim was to compare the performance of a prototype ABS system with a manual reference system over a 30 h sampling period under controlled conditions in humans. Two venous cannulae were inserted to connect the ABS system and the reference system. Blood samples were taken with both systems at 15, 30, and 60 min intervals and analyzed using a Beckman glucose analyzer. During the study, blood glucose levels were altered through four meal ingestions. RESULTS: The median Pearson coefficient of correlation between manually and automatically withdrawn blood samples was 0.976 (0.953-0.996). The system error was -3.327 ± 5.546% (-6.03-0.49). Through Clark error grid analysis, 420 data pairs were analyzed, showing that 98.6% of the data were in zone A and 1.4% were in zone B. Insulin titration error grid analysis revealed an acceptable treatment in 100% of cases. A 17.5-fold reduction in the occurrence of blood-withdrawal failures through occluded catheters was moreover achieved by the added implementation in the ABS system of a "keep vein open" saline infusion. CONCLUSIONS: Our study showed that the ABS system described provides a user-friendly, reliable automated means for reproducible and accurate blood sampling from a peripheral vein for blood glucose determination and thus represents a promising alternative to frequent manual blood sampling.


Assuntos
Glicemia/análise , Monitorização Fisiológica/métodos , Adulto , Humanos , Masculino , Reprodutibilidade dos Testes