Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Diabetes Obes Metab ; 17(12): 1166-72, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26260082

RESUMO

AIMS: To find an explanation for the lower potency of insulin detemir observed in humans compared with unmodified human insulin by investigating insulin detemir and human insulin concentrations directly at the level of peripheral insulin-sensitive tissues in humans in vivo. METHODS: Euglycaemic-hyperinsulinaemic clamp experiments were performed in healthy volunteers. Human insulin was administered i.v. at 6 pmol/kg/min and insulin detemir at 60 pmol/kg/min, achieving a comparable steady-state pharmacodynamic action. In addition, insulin detemir was doubled to 120 pmol/kg/min. Minimally invasive open-flow microperfusion (OFM) sampling methodology was combined with inulin calibration to quantify human insulin and insulin detemir in the interstitial fluid (ISF) of subcutaneous adipose and skeletal muscle tissue. RESULTS: The human insulin concentration in the ISF was ∼115 pmol/l or ∼30% of the serum concentration, whereas the insulin detemir concentration in the ISF was ∼680 pmol/l or ∼2% of the serum concentration. The molar insulin detemir interstitial concentration was five to six times higher than the human insulin interstitial concentration and metabolic clearance of insulin detemir from serum was substantially reduced compared with human insulin. CONCLUSIONS: OFM proved useful for target tissue measurements of human insulin and the analogue insulin detemir. Our tissue data confirm a highly effective retention of insulin detemir in the vascular compartment. The higher insulin detemir relative to human insulin tissue concentrations at comparable pharmacodynamics, however, indicate that the lower potency of insulin detemir in humans is attributable to a reduced effect in peripheral insulin-sensitive tissues and is consistent with the reduced in vitro receptor affinity.


Assuntos
Líquido Extracelular/metabolismo , Hipoglicemiantes/farmacocinética , Insulina Detemir/farmacocinética , Insulina Regular Humana/farmacocinética , Adulto , Disponibilidade Biológica , Calibragem , Estudos Cross-Over , Relação Dose-Resposta a Droga , Técnica Clamp de Glucose , Humanos , Hipoglicemiantes/administração & dosagem , Hipoglicemiantes/sangue , Hipoglicemiantes/metabolismo , Infusões Intravenosas , Insulina Detemir/administração & dosagem , Insulina Detemir/sangue , Insulina Detemir/metabolismo , Insulina Regular Humana/administração & dosagem , Insulina Regular Humana/sangue , Insulina Regular Humana/metabolismo , Inulina/administração & dosagem , Inulina/sangue , Inulina/metabolismo , Inulina/farmacocinética , Lipoilação , Masculino , Taxa de Depuração Metabólica , Músculo Esquelético/metabolismo , Gordura Subcutânea/metabolismo , Distribuição Tecidual , Adulto Jovem
2.
Biomed Microdevices ; 17(4): 73, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26141039

RESUMO

In this work we present a low cost, minimally invasive, and chip-based near infrared (NIR) sensor, combined with subcutaneous microdialysis, for continuous glucose monitoring (CGM). The sensor principle is based on difference absorption spectroscopy in the 1st overtone band known to be dominated by glucose-specific absorption features. The device comprises a multi-emitter LED and InGaAs-photodiodes, which are located on a single electronic board (non-disposable part), connected to a personal computer via Bluetooth. The disposable part consists of a chip containing the fluidic connections for microdialysis, two fluidic channels acting as optical transmission cells and total internally reflecting mirrors for in- and out-coupling of the light to the chip and to the detectors. The use of the sensor in conjunction with a subcutaneous microdialysis catheter to separate the glucose from the cells and proteins has been demonstrated to be extremely useful and advantageous for obtaining continuous glucose monitoring data and detecting glycemic levels in real time for a long period. Several in vitro and in vivo experiments were conducted to test the reliability of the device. In vitro measurements showed a linear relationship between glucose concentration and the integrated difference signal with a coefficient of determination of 99 % at the physiological concentration range. Clinical trial on 6 subjects with Type 1 diabetes showed that the NIR-CGM sensor data reflects the blood reference values adequately, if a proper calibration and signal drift compensation is applied. The MARD (mean absolute relative difference) value taken on retrospective data over all subjects is 8.5 % (range 6-11.5 %).


Assuntos
Glicemia/análise , Microdiálise/instrumentação , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Técnicas Biossensoriais/instrumentação , Calibragem , Diabetes Mellitus Tipo 1/sangue , Desenho de Equipamento , Estudos de Viabilidade , Humanos , Miniaturização , Valores de Referência , Reprodutibilidade dos Testes
3.
Appl Clin Inform ; 5(2): 548-56, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25024768

RESUMO

BACKGROUND: Standardized insulin order sets for subcutaneous basal-bolus insulin therapy are recommended by clinical guidelines for the inpatient management of diabetes. The algorithm based GlucoTab system electronically assists health care personnel by supporting clinical workflow and providing insulin-dose suggestions. OBJECTIVE: To develop a toolbox for improving clinical decision-support algorithms. METHODS: The toolbox has three main components. 1) Data preparation: Data from several heterogeneous sources is extracted, cleaned and stored in a uniform data format. 2) Simulation: The effects of algorithm modifications are estimated by simulating treatment workflows based on real data from clinical trials. 3) ANALYSIS: Algorithm performance is measured, analyzed and simulated by using data from three clinical trials with a total of 166 patients. RESULTS: Use of the toolbox led to algorithm improvements as well as the detection of potential individualized subgroup-specific algorithms. CONCLUSION: These results are a first step towards individualized algorithm modifications for specific patient subgroups.


Assuntos
Algoritmos , Sistemas de Apoio a Decisões Clínicas , Cálculos da Dosagem de Medicamento , Insulina/administração & dosagem , Glicemia/metabolismo , Humanos , Insulina/farmacologia , Monitorização Fisiológica
4.
Diabetes Obes Metab ; 16(2): 137-46, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23910952

RESUMO

AIMS: To evaluate glycaemic control and usability of a workflow-integrated algorithm for basal-bolus insulin therapy in a proof-of-concept study to develop a decision support system in hospitalized patients with type 2 diabetes. METHODS: In this ward-controlled study, 74 type 2 diabetes patients (24 female, age 68 ± 11 years, HbA1c 8.7 ± 2.4% and body mass index 30 ± 7) were assigned to either algorithm-based treatment with a basal-bolus insulin therapy or to standard glycaemic management. Algorithm performance was assessed by continuous glucose monitoring and staff's adherence to algorithm-calculated insulin dose. RESULTS: Average blood glucose levels (mmol/l) in the algorithm group were significantly reduced from 11.3 ± 3.6 (baseline) to 8.2 ± 1.8 (last 24 h) over a period of 7.5 ± 4.6 days (p < 0.001). The algorithm group had a significantly higher percentage of glucose levels in the ranges from 5.6 to 7.8 mmol/l (target range) and 3.9 to 10.0 mmol/l compared with the standard group (33 vs. 23% and 73 vs. 53%, both p < 0.001). Physicians' adherence to the algorithm-calculated total daily insulin dose was 95% and nurses' adherence to inject the algorithm-calculated basal and bolus insulin doses was high (98 and 93%, respectively). In the algorithm group, significantly more glucose values <3.9 mmol/l were detected in the afternoon relative to other times (p < 0.05), a finding mainly related to pronounced morning glucose excursions and requirements for corrective bolus insulin at lunch. CONCLUSIONS: The workflow-integrated algorithm for basal-bolus therapy was effective in establishing glycaemic control and was well accepted by medical staff. Our findings support the implementation of the algorithm in an electronic decision support system.


Assuntos
Glicemia/efeitos dos fármacos , Diabetes Mellitus Tipo 2/tratamento farmacológico , Hemoglobinas Glicadas/efeitos dos fármacos , Hipoglicemiantes/administração & dosagem , Insulina de Ação Prolongada/administração & dosagem , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Glicemia/metabolismo , Automonitorização da Glicemia , Índice de Massa Corporal , Técnicas de Apoio para a Decisão , Diabetes Mellitus Tipo 2/sangue , Relação Dose-Resposta a Droga , Feminino , Hemoglobinas Glicadas/metabolismo , Humanos , Pacientes Internados , Masculino , Pessoa de Meia-Idade , Monitorização Fisiológica , Participação do Paciente , Reprodutibilidade dos Testes , Estudos Retrospectivos , Resultado do Tratamento , Fluxo de Trabalho
6.
Artigo em Inglês | MEDLINE | ID: mdl-23945606

RESUMO

Models of glucose metabolism are a valuable tool for fundamental and applied medical research in diabetes. Use cases range from pharmaceutical target selection to automatic blood glucose control. Standard compartmental models represent little biological detail, which hampers the integration of multiscale data and confines predictive capabilities. We developed a detailed, generic physiologically based whole-body model of the glucose-insulin-glucagon regulatory system, reflecting detailed physiological properties of healthy populations and type 1 diabetes individuals expressed in the respective parameterizations. The model features a detailed representation of absorption models for oral glucose, subcutaneous insulin and glucagon, and an insulin receptor model relating pharmacokinetic properties to pharmacodynamic effects. Model development and validation is based on literature data. The quality of predictions is high and captures relevant observed inter- and intra-individual variability. In the generic form, the model can be applied to the development and validation of novel diabetes treatment strategies.CPT: Pharmacometrics & Systems Pharmacology (2013) 2, e65; doi:10.1038/psp.2013.40; published online 14 August 2013.

7.
Skin Res Technol ; 19(4): 474-83, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23581539

RESUMO

BACKGROUND: Sampling the dermal interstitial fluid (ISF) allows the pharmacokinetics and pharmacodynamics of dermatological drugs to be studied directly at their site of action. Dermal open-flow microperfusion (dOFM) is a recently developed technique that can provide minimally invasive, continuous, membrane-free (thus unfiltered) access to the dermal ISF. Herein, we evaluate the clinical applicability and reliability of novel wearable dOFM devices in a clinical setting. METHODS: Physicians inserted 141 membrane-free dOFM probes into the dermis of 17 healthy and psoriatic volunteers and sampled dermal ISF for 25 h by using wearable push-pull pumps. The tolerability, applicability, reproducibility, and reliability of multiple insertions and 25 h continuous sampling was assessed by pain scoring, physician feedback, ultrasound probe depth measurements, and 25 h-drift and variability of the sodium relative recovery. RESULTS: Insertion pain was moderate and decreased with each additional probe. Probe insertion was precise, although slightly deeper in lesional skin. The wearable push-pull pump enabled uninterrupted ISF sampling over 25 h with low variability. The relative recovery was drift-free and highly reproducible. CONCLUSION: dOFM sampling devices are tolerable and reliable for prolonged continuous dermal sampling in a multiprobe clinical setting. These devices should enable the study of a wide range of drugs and their biomarkers in the skin.


Assuntos
Fármacos Dermatológicos/farmacocinética , Derme/metabolismo , Líquido Extracelular/metabolismo , Bombas de Infusão , Microdiálise/instrumentação , Perfusão/instrumentação , Administração Cutânea , Adulto , Biomarcadores/metabolismo , Fármacos Dermatológicos/administração & dosagem , Derme/efeitos dos fármacos , Feminino , Humanos , Masculino , Microdiálise/métodos , Microdiálise/normas , Pessoa de Meia-Idade , Agulhas , Perfusão/métodos , Perfusão/normas , Reprodutibilidade dos Testes , Sódio/metabolismo , Adulto Jovem
8.
Biosens Bioelectron ; 24(7): 2239-45, 2009 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-19135351

RESUMO

Intensive insulin therapy reduces mortality and morbidity in critically ill patients but imposes great demands on medical staff who must take frequent blood samples for the determination of glucose levels. A solution to this resourcing problem would be provided by an automated blood monitoring system. The aim of the present clinical study was to evaluate such a system comprising an automatic blood sampling unit linked to a glucose biosensor. Our approach was to determine the correlation and system error of the sampling unit alone and of the combined system with respect to reference levels over 12h in humans. Two venous cannulae were inserted to connect the automatic and reference systems to the subjects. Blood samples were taken at 15 and 30 min intervals. The median Pearson coefficient of correlation between manually and automatically withdrawn blood samples was 0.982 for the sampling unit alone and 0.950 for the complete system. The biosensor had a linear range up to 20 mmoll(-1) and a 95% response time of <2 min. Clark Error Grid analysis showed that 96.93% of the data (228 data pairs) was in zone A and 3.07% in zone B. Insulin Titration Error Grid analysis suggested an acceptable treatment in 99.56% of cases. Implementation of a "Keep Vein Open" saline infusion into the automated blood sampling system reduced blood withdrawal failures through occluded catheters fourfold. In summary, automated blood sampling from a peripheral vein coupled with automatic glucose determination is a promising alternative to frequent manual blood sampling.


Assuntos
Técnicas Biossensoriais/instrumentação , Análise Química do Sangue/instrumentação , Glicemia/análise , Cateterismo/instrumentação , Análise de Injeção de Fluxo/instrumentação , Flebotomia/instrumentação , Robótica/instrumentação , Análise Química do Sangue/métodos , Cateterismo/métodos , Desenho de Equipamento , Análise de Falha de Equipamento , Análise de Injeção de Fluxo/métodos , Humanos , Flebotomia/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
9.
Diabet Med ; 23(1): 90-3, 2006 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-16409572

RESUMO

AIMS: To evaluate an algorithm with glucose prediction capacity and continuous adaptation of patient parameters-a model predictive control (MPC) algorithm-to control blood glucose concentration during fasting conditions in patients with Type 1 diabetes. In the subcutaneous (sc) route within a closed loop system. METHODS: Paired experiments were performed in six patients. Over 8 h the MPC algorithm was used to control glucose with s.c. insulin administration and two different glucose monitoring protocols: first, the algorithm was provided with intravenous (i.v.) glucose values for insulin dosage calculation directly (i.v.-s.c. route). Then, in the second experiment, i.v. glucose values were fed to the MPC with a delay of 30 min to simulate s.c. glucose measurements ('s.c.'-s.c. route). In both experiments plasma glucose, insulin dosage, and serum insulin levels were analysed. RESULTS: Glucose concentration was brought from hyper- to normoglycaemia and kept in the physiological range (6-7 mmol/l) with both routes in all subjects. Mean glucose concentration reached the threshold of 7 mmol/l approximately 2 (i.v.-s.c. route) and 3 ('s.c.'-s.c. route) hours after the start of glucose control with the MPC. During the last 2 h of automated glucose control, mean glucose concentration was 6.3 +/- 0.2 mmol/l and 6.6 +/- 0.3 mmol/l for i.v.-s.c. and 's.c.'-s.c. route, respectively. Glucose concentration, insulin doses, and serum insulin levels did not differ significantly between routes (P > 0.05). CONCLUSIONS: The MPC algorithm is suitable for glucose control during fasting within an extracorporeal artificial beta-cell in the subcutaneous route Type 1 diabetic patients.


Assuntos
Algoritmos , Glicemia/análise , Diabetes Mellitus Tipo 1/sangue , Administração Cutânea , Simulação por Computador , Esquema de Medicação , Jejum , Feminino , Humanos , Insulina/administração & dosagem , Insulina/sangue , Sistemas de Infusão de Insulina , Masculino , Modelos Biológicos
10.
Diabetologia ; 44(3): 305-8, 2001 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-11317660

RESUMO

AIMS/HYPOTHESIS: The AERx insulin Diabetes Management system (AERx iDMS) is a liquid aerosol device that enables insulin to be administered to the peripheral parts of the lung. This study aimed to compare the pharmacokinetic and pharmacodynamic properties of insulin which is inhaled using AERx iDMS with insulin which is subcutaneously administered. METHODS: In total, 18 C-peptide negative patients with Type I (insulin-dependent) diabetes mellitus participated in this randomised, open-label, 5-period crossover trial. Human regular insulin was administered subcutaneously (0.12 U/kg body weight) or inhaled by means of the AERx iDMS (dosages 0.3, 0.6, 1.2, and 1.8 U/kg body weight). Thereafter plasma glucose was kept constant at 7.2 mmol/l for a 10-h period (glucose clamp technique). RESULTS: Inhaled insulin provided a dose-response relation that was close to linear for both pharmacokinetic (AUC-Ins(0-10 h); Cmax-Ins) and pharmacodynamic (AUC-GIR(0-10 h); GIRmax) parameters. Time to maximum insulin concentration (Tmax-Ins) and time to maximum glucose infusion rate (TGIRmax) were shorter with inhaled insulin than with subcutaneous administration. The pharmacodynamic system efficiency of inhaled insulin (AUC-GIR(0-6 h) was 12.7% (95% C.I.: 10.2-15.6). CONCLUSION/INTERPRETATION: The inhalation of soluble human insulin using the AERx iDMS is feasible and provides a clear dose response. Further long-term studies are required to investigate safety aspects, HbA1c values, incidence of hypoglycaemic events and the quality of life.


Assuntos
Diabetes Mellitus Tipo 1/tratamento farmacológico , Insulina/administração & dosagem , Administração por Inalação , Adulto , Aerossóis , Área Sob a Curva , Glicemia/efeitos dos fármacos , Glicemia/metabolismo , Peptídeo C/sangue , Diabetes Mellitus Tipo 1/sangue , Relação Dose-Resposta a Droga , Humanos , Hipoglicemiantes/administração & dosagem , Hipoglicemiantes/uso terapêutico , Injeções Subcutâneas , Insulina/farmacocinética , Insulina/uso terapêutico , Fatores de Tempo
11.
Diabet Med ; 17(5): 371-5, 2000 May.
Artigo em Inglês | MEDLINE | ID: mdl-10872536

RESUMO

AIMS: In intensified insulin therapy, the recent development of short-acting insulin analogues with a very rapid onset of action forces a new discussion in terms of the optimal injection-meal interval. This study evaluated prandial glycaemia in patients with Type 1 diabetes following the subcutaneous injection of soluble human insulin (HI) and the insulin analogue insulin aspart (IAsp) at different injection-meal intervals and investigated whether administration of IAsp after the meal might provide satisfactory metabolic control. METHODS: In a randomized, double-blind, double-dummy, four-period crossover study, 20 Type 1 diabetic patients were investigated. Prandial insulin was administered 15 min before the start of the meal (HI(-15min)), immediately before the meal (HI(0min); IAsp(0min)) and 15 min after the start of the meal (IAsp(+15min)). RESULTS: Plasma glucose excursions from baseline levels during the 4 h (PGexc) were highest with HI(0min) (17.9 mmol.l(-1).h; P < 0.05 vs. other treatments) and were not statistically different for HI(-15min), IAsp(0min) and IAsp(15min) (13.6, 11.9 and 14.2 mmol.l(-1).h, respectively). Maximum concentration of plasma glucose (PGmax) was lowest with IAsp(0min) (11.2 mmol/l; P < 0.05 vs. other treatments). PGmax was comparable with HI(-15min), HI(0min) and IAsp(+15min) (13.3, 14.1 and 13.2 mmol/l, respectively). CONCLUSIONS: With regard to prandial glycaemia IAsp(+15min) is as effective as HI(-5min) and superior to HI(0min). Thus, post-prandial dosing of the insulin analogue IAsp offers an attractive and feasible therapeutic option for well-controlled patients with Type 1 diabetes mellitus.


Assuntos
Diabetes Mellitus Tipo 1/tratamento farmacológico , Alimentos , Hipoglicemiantes/administração & dosagem , Insulina/análogos & derivados , Insulina/administração & dosagem , Adulto , Glicemia/metabolismo , Estudos Cross-Over , Diabetes Mellitus Tipo 1/sangue , Método Duplo-Cego , Feminino , Humanos , Hipoglicemiantes/uso terapêutico , Insulina/uso terapêutico , Insulina Aspart , Masculino , Pessoa de Meia-Idade
12.
Am J Physiol Endocrinol Metab ; 278(2): E352-6, 2000 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-10662720

RESUMO

The absolute concentration of albumin was measured in the interstitial fluid of subcutaneous adipose tissue and skeletal muscle in six healthy volunteers by combining the method of open-flow microperfusion and the no-net-flux calibration technique. By use of open-flow microperfusion, four macroscopically perforated double lumen catheters were inserted into the tissue regions of interest and constantly perfused. Across the macroscopic perforations of the catheters interstitial fluid was partially recovered in the perfusion fluid. Catheters were perfused with five solutions, each containing different concentrations of albumin. Absolute interstitial albumin concentrations were calculated by applying linear regression analysis to perfusate vs. sampled albumin concentration (no-net-flux calibration technique). Interstitial albumin concentrations were significantly lower (P < 0.0001) in adipose tissue (7.36 g/l; r = 0.99, P < 0.0003; range: 4.3-10.7 g/l) and in skeletal muscle (13.25 g/l; r = 0.99, P < 0.0012; range: 9.7 to 15.7 g/l) compared with the serum concentration (48.9 +/- 0.7 g/l, mean +/- SE, n = 6; range: 46.4-50.4 g/l). Furthermore, interstitial albumin concentrations were significantly higher in skeletal muscle compared with adipose tissue (P < 0.01). The study indicates that open-flow microperfusion allows stable sampling of macromolecules from the interstitial space of peripheral tissue compartments. Moreover, the present data report for the first time in healthy humans in vivo the true albumin concentrations of interstitial fluid of adipose tissue and skeletal muscle.


Assuntos
Tecido Adiposo/química , Albuminas/análise , Espaço Extracelular/química , Músculo Esquelético/química , Adulto , Humanos , Masculino , Perfusão , Albumina Sérica/análise
13.
Diabetes ; 48(5): 1070-81, 1999 May.
Artigo em Inglês | MEDLINE | ID: mdl-10331412

RESUMO

Recent experimental evidence suggests that estimates of glucose effectiveness (S(G)) from the minimal model of unlabeled glucose disappearance (Cold-MM) are in error. The single-compartment glucose distribution assumption embedded in the model has been indicated as a possible source of error. In this study, to directly examine the single-compartment assumption, we measured plasma and interstitial glucose concentrations after intravenous glucose injection. Additionally, we compared the accuracy of the estimates of glucose effectiveness from the Cold-MM and the single-compartment tracer minimal model (Hot-MM). Paired labeled intravenous glucose tolerance tests (IVGTTs) were performed in each of six C-peptide-negative type 1 diabetic subjects. Two different insulin infusion protocols were used: an infusion at constant basal rates and an infusion at variable rates to mimic a normal insulin response. During the labeled IVGTT with basal insulin infusion, the microperfusion technique was employed to sample adipose tissue interstitial fluid. Marked differences between the plasma and interstitial dynamics of (cold) glucose were observed during the first 22 min after glucose injection. These results suggest that the requirements for a single-compartment representation of glucose kinetics are not satisfied during at least the first 22 min of an IVGTT. Data from the labeled IVGTT with normal insulin response were used to identify the minimal-model parameters. The measure of S(G) derived using the Cold-MM was 3.44-fold higher than the direct measure obtained from the labeled IVGTT with basal insulin infusion (0.0179+/-0.0027 vs. 0.0052+/-0.0010 min(-1), P<0.01). The measure of glucose effectiveness (S(G)*) derived by the Hot-MM was 1.36-fold higher than the direct measure available from the labeled IVGTT with basal insulin infusion (0.0079+/-0.0013 vs. 0.0058+/-0.0004 min(-1), P>0.26). These results suggest that the Hot-MM is more appropriate for the evaluation of glucose effectiveness than the Cold-MM.


Assuntos
Glicemia/metabolismo , Diabetes Mellitus Tipo 1/metabolismo , Glucose/administração & dosagem , Adulto , Peptídeo C/sangue , Deutério , Espaço Extracelular/química , Feminino , Glucose/análise , Teste de Tolerância a Glucose , Humanos , Injeções Intravenosas , Insulina/sangue , Cinética , Masculino , Matemática , Pessoa de Meia-Idade , Modelos Biológicos , Sódio/sangue
14.
Am J Physiol ; 276(2): E401-8, 1999 02.
Artigo em Inglês | MEDLINE | ID: mdl-9950802

RESUMO

To gain direct access to the interstitial fluid (ISF), a new technique called open-flow microperfusion has been evaluated. This method is based on a double-lumen catheter with macroscopic (0.3-0.5 mm diameter) perforations that is inserted into the subcutaneous adipose tissue and constantly perfused. Thus partial equilibration between the ISF and the perfusion fluid occurs. The glucose concentration of the ISF was determined by established (zero flow rate, no net flux, and recirculation procedures) and new (ionic reference and suction technique) calibration methods by use of open-flow microperfusion. The data show that 1) the glucose concentration in the ISF is significantly lower than the corresponding arterialized venous plasma values during basal steady-state conditions (adipose tissue 3.2 +/- 0.10 mM, plasma 5.27 +/- 0.12 mM) as well as during hyperglycemic clamp experiments (adipose tissue 7.3 +/- 0.13 mM, plasma 9.91 +/- 0.16 mM), and 2) it is possible to determine the recovery continuously by using the ion concentration of the ISF as an internal standard (ionic reference).


Assuntos
Tecido Adiposo/metabolismo , Espaço Extracelular/metabolismo , Perfusão/métodos , Adulto , Calibragem , Glucose/metabolismo , Homeostase/fisiologia , Humanos , Hiperglicemia/metabolismo , Microdiálise/métodos , Concentração Osmolar , Valores de Referência , Sucção/métodos
15.
J Clin Endocrinol Metab ; 83(12): 4394-401, 1998 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-9851784

RESUMO

Open flow microperfusion and a novel calibration technique (ionic reference technique) were evaluated for the frequent measurement of the absolute lactate concentration in sc adipose tissue. Furthermore, the influence of the plasma insulin concentration on the lactate concentration of sc adipose tissue was investigated during hyperglycemia. Sixteen lean healthy young men participated in the studies. In the postabsorbtive state the mean sc lactate concentrations were 1.29 and 1.36 mmol/L for the ionic reference technique and the no net flux protocol, respectively (not significant, P > 0.05). The simultaneously measured arterialized plasma lactate concentration was significantly lower at 0.77 mmol/L (P < 0.05). Both the sc lactate concentration (1.8+/-0.33 mmol/L) and the plasma lactate concentration (0.96+/-0.03 mmol/L) were significantly elevated during a hyperinsulinemic euglycemic clamp experiment. During a hyperglycemic clamp experiment the sc lactate concentration reached a significantly elevated plateau (2.15+/-0.27 mmol/L) that was not influenced by the increasing plasma insulin concentration. It is concluded that 1) open flow microperfusion combined with the ionic reference technique enables frequent measurement of the sc lactate concentration; 2) sc adipose tissue is a significant source of lactate release in the postabsorbtive state as well as during hyperinsulinemic clamp conditions; and 3) insulin concentrations greater than 180 pmol/L have no further influence on adipocyte stimulation of sc adipose tissue with respect to lactate release.


Assuntos
Tecido Adiposo/metabolismo , Ácido Láctico/metabolismo , Adulto , Técnica Clamp de Glucose , Humanos , Hiperglicemia/sangue , Hiperglicemia/metabolismo , Hiperinsulinismo/metabolismo , Masculino , Concentração Osmolar , Perfusão/métodos , Pele
16.
Biosens Bioelectron ; 13(9): 1007-13, 1998 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-9839389

RESUMO

The present study was carried out to investigate in vivo in healthy humans the method of open-flow microperfusion for monitoring of the subcutaneous (s.c.) lactate concentration during rest and cycle ergometer exercise. Using open-flow microperfusion, a perforated double lumen catheter with an inflow and an outflow connection is inserted into the s.c. adipose tissue and perfused with a sterile, isotonic, ionfree fluid. Due to the low flow rate, the fluid partially equilibrates with the surrounding tissue. The equilibrated perfusate passes a sensor flow chamber where the substance of interest and the rate of recovery (i.e. the ratio of sampled concentration to interstitial concentration) are continuously monitored. Within this study, the method was evaluated in four healthy volunteers during cycle ergometer exercise. The relative increase of the lactate concentration was approximately a third in the s.c. tissue compared to the capillary blood and the peak time was delayed on average by 10 min. The correlation coefficient between blood and s.c. tissue lactate concentration ranged from r = 0.41 to r = 0.90 (n = 29) in the individual experiments. The combination of open-flow microperfusion and lactate and conductivity sensors enables on-line monitoring of the s.c. lactate concentration without in vivo calibration during steady-state and cycle ergometer exercise.


Assuntos
Técnicas Biossensoriais/instrumentação , Exercício Físico/fisiologia , Ácido Láctico/análise , Monitorização Fisiológica/instrumentação , Tecido Adiposo/metabolismo , Adulto , Teste de Esforço , Humanos , Ácido Láctico/sangue , Ácido Láctico/metabolismo , Masculino
17.
Diabetes Care ; 21(4): 585-90, 1998 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-9571347

RESUMO

OBJECTIVE: To evaluate the clinical and analytical accuracy of home blood glucose meters. RESEARCH DESIGN AND METHODS: Six blood glucose meters--Reflolux S (Boehringer Mannheim, Mannheim, Germany), One Touch II (LifeScan, Milpitas, CA), Glucocard Memory (Menarini, Florence, Italy), Precision QID (Medisense, Cambridge, U.K.), HaemoCue (HaemoCue, Angelholm, Sweden), and Accutrend alpha (Boehringer Mannheim, Mannheim, Germany)--were compared with a reference method (Beckman Glucose Analyzer II) under controlled conditions (glucose clamp technique). Validation of the blood glucose meters was accomplished by clinically oriented approaches (error grid analysis), statistical approaches (variance components analysis), and by the criteria of the American Diabetes Association (ADA), which recommend a target variability of < 5%. RESULTS: A total of 1,794 blood glucose monitor readings and 299 reference values ranging from 2.2 to 18.2 mmol/l were analyzed (705 readings < 3.89 mmol/l, 839 readings between 3.89 and 9.99 mmol/l, and 250 readings > 9.99 mmol/l). According to error grid analysis, only Reflolux S and Glucocard M had 100% of estimations within the clinically acceptable zones A and B. Assessment of analytical accuracy revealed substantial differences between the glucose meters after separation of the data into defined glycemic ranges. None of the devices met the ADA criteria. CONCLUSIONS: To evaluate accuracy of blood glucose meters, error grid analysis, as well as statistical models, are helpful means and should be performed together. Analytical performance of currently available home blood glucose meters differs substantially within defined glycemic ranges.


Assuntos
Automonitorização da Glicemia/instrumentação , Diabetes Mellitus Tipo 1/sangue , Automonitorização da Glicemia/normas , Humanos , Controle de Qualidade , Valores de Referência , Análise de Regressão , Reprodutibilidade dos Testes
18.
Biosens Bioelectron ; 13(12): 1271-8, 1998 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-9883561

RESUMO

The objective of the study was to evaluate the performance of an amperometric enzyme based lactate sensor and to investigate the possibility of replacing a double lumen catheter based blood withdrawal system with a heparin coated single lumen system. The inner lumen of a double lumen catheter which was placed in a peripheral vein was perfused with heparin solution. The outer lumen was used to collect heparinized blood samples at a defined flow rate. The single lumen system was attached to a heparinized catheter which was also placed in a peripheral vein. The undiluted blood samples were collected at a specified flow rate. A sensor flow chamber incorporating an amperometric thin-film lactate microbiosensor was placed in the sampling line for real-time lactate monitoring. Plasma lactate concentrations were measured during frequently performed hyperlactatemia bicycle ergometer experiments in six healthy volunteers (age 25.8 +/- 2.8 years, BMI 22.7 +/- 1 kg/m2). Additionally, plasma lactate was measured in real-time using the lactate sensors. The first three experiments were performed with a double lumen based catheter system whereas the following three experiments were performed with a heparin coated catheter system. The correlation coefficients of sensor readings and laboratory analyzer results in all six experiments were between 0.93 and 0.99, respectively (P < 0.001). The miniaturized lactate sensors showed a linear range up to 25 mmol/l lactate concentration and 95% response times < 30 s in undiluted serum. During the experiments maximum lactate concentrations of 14 mmol/l were achieved. Improvements of system performance using heparin coated catheter systems could be shown. The overall SD of the sensor readings compared to laboratory results using three double lumen catheter based systems was 0.91 mmol/l whereas the SD using three heparin coated systems was 0.65 mmol/l. In summary, real-time monitoring of lactate in human whole blood is feasible with such a device and can be improved by using heparin coated catheter systems.


Assuntos
Técnicas Biossensoriais , Ácido Láctico/sangue , Adulto , Heparina/farmacologia , Humanos , Masculino
19.
Diabetes Care ; 20(7): 1114-21, 1997 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-9203447

RESUMO

OBJECTIVE: To evaluate a novel technique for on-line continuous glucose measurement in subcutaneous adipose tissue, and to investigate its accuracy for detection of hypoglycemia. RESEARCH DESIGN AND METHODS: The method combined an open-flow microperfusion of subcutaneous adipose tissue using a double lumen catheter and an extracorporeal sensor cell. An isotonic ion-free solution was perfused through the inner lumen of the catheter, equilibrated with the subcutaneous tissue fluid, and sampled through the outer lumen. The recovery was continuously monitored as the ratio between the measured sampled fluid conductivity and the subcutaneous tissue fluid conductivity (assumed to have a constant value of 1.28 S/m at 25 degrees C). Glucose concentration was calculated on-line from the measured glucose in the sampled fluid and the measured recovery in healthy volunteers during hyperglycemic glucose loads (n = 8), hypoglycemic hyperinsulinemic clamp (n = 6), and a 24-h monitoring period (n = 7). RESULTS: Subcutaneous glucose concentrations in the fasting state were 94% of the plasma glucose concentrations in arterialized venous samples. According to the error grid analysis, 96.9% of the on-line measured subcutaneous glucose concentrations during hyperglycemia and 96.3% during hypoglycemia were in accurate or acceptable zones. The mean differences between the measured subcutaneous glucose and the actual plasma glucose concentration were -0.06-3.3 mmol/l (hyperglycemia), and -0.6-1.1 mmol/l (hypoglycemia). CONCLUSIONS: By combining open-flow microperfusion, glucose sensor, and conductivity measurement, glucose concentration in the subcutaneous adipose tissue can be monitored on-line, extracorporeally, and continuously without any in vivo calibration, and gives accurate measurements during hyper- and hypoglycemia.


Assuntos
Tecido Adiposo/química , Glucose/análise , Hipoglicemia/diagnóstico , Sistemas On-Line/instrumentação , Perfusão/métodos , Tecido Adiposo/metabolismo , Adulto , Glicemia/análise , Ritmo Circadiano , Feminino , Glucose/metabolismo , Técnica Clamp de Glucose , Humanos , Hiperglicemia/sangue , Hiperglicemia/diagnóstico , Hipoglicemia/sangue , Masculino , Concentração Osmolar , Perfusão/instrumentação , Potássio/sangue , Reprodutibilidade dos Testes , Pele , Sódio/sangue , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...