Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Eur J Radiol ; 83(7): 1205-1208, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24815747

RESUMO

PURPOSE: Aim was to determine immediate results and mid-term outcome of the hemoparin-coated (HC) stainless-steel stent (camouflage coating) in the treatment of occlusive lesions of the iliac arteries. MATERIALS AND METHODS: Twenty-eight patients were prospectively treated with the use of a HC stent between January 2007 and March 2010. Clinical examination and color-doppler ultrasound were performed at 1, 3, 6 and 12 months, CT angiography (CTA) or MR angiography (MRA) at 12 months. Indication for treatment was a high-grade stenosis of the common iliac and/or external iliac artery. RESULTS: Successful placement was achieved in all patients. Significant decrease in translesional pressure gradient (>10 mm Hg) was measured in 27 patients (96%). In one patient, proximal dissection occurred without flow limitation. A minor complication (small access site hematoma) occurred in one patient (4%). Two patients (7%) were lost to follow-up. After 12 months, stent patency in CTA, MRA and ultrasound was 100%. 20 patients (77%) experienced an initial improvement of at least one clinical stage. In one patient (4%), mild intimal hyperplasia without significant stenosis was observed. In three patients (12%), proximal or distal stenosis occurred. A non-significant increase of mean ankle-brachial index (ABI) after treatment was measured (0.85 ± 0.27 vs. 0.75 ± 0.22, respectively; p=0.328). CONCLUSIONS: The use of HC stents in patients with iliac artery occlusive disease may lead to a lower rate of intimal hyperplasia and thus to increased patency rates even in heavily calcified vessels. However, large-scale prospective trials have to be performed to evaluate the long-term patency rates of the HC coated stents.


Assuntos
Arteriopatias Oclusivas/terapia , Prótese Vascular , Stents Farmacológicos , Artéria Ilíaca/cirurgia , Doença Arterial Periférica/terapia , Implantação de Prótese/métodos , Idoso , Idoso de 80 Anos ou mais , Angiografia/métodos , Arteriopatias Oclusivas/diagnóstico por imagem , Arteriopatias Oclusivas/patologia , Feminino , Humanos , Artéria Ilíaca/diagnóstico por imagem , Artéria Ilíaca/patologia , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/patologia , Resultado do Tratamento
2.
Case Rep Med ; 2013: 714914, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24368920

RESUMO

Secondary dissection in the descending aorta after endovascular therapy may demand subsequent interventional procedures. This can set a particularly significant challenge for the endovascular specialist. When implanting an aortic prosthesis, a sufficient contact between the covered segment and the healthy vessel wall is advisable. However, our case shows that, in individual cases, it is indeed efficient to place an aortic stent graft on top of the distal end of the dissection. This is proven by a three-year follow-up CT-angiography.

3.
Eur Radiol ; 13(7): 1549-58, 2003 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-12835966

RESUMO

The aim of this study was to evaluate the healing response to a new commercially available ePTFE-covered stent graft used to create transjugular intrahepatic portosystemic shunts (TIPS) in an animal model with and without intraluminal irradiation. The study was designed for ten domestic normotensive pigs. The TIPS was created using a ePTFE-covered stent graft (Viatorr, Gore, Flagstaff, Ariz.). Five animals were scheduled for intraluminal irradiation with iridium 192 immediately after TIPS creation with a dosage of 18 Gy. Shunt venograms were performed every 2 weeks. Animals from the irradiated and non-irradiated group were killed at 2-week intervals. Maximum follow-up was planned for 8 weeks in each group, with two animals in reserve. Gross specimen evaluation and histological examination, including scanning electron microscopy, was performed. Two animals died from interventional complications. In the irradiation group, one shunt occlusion and one stenosis occurred after 2 weeks. The stenosis regressed until the end of the 8-week follow-up period and probably was caused by a resolving thrombus. In the non-irradiated group, no shunt dysfunction was observed. One animal died early due to encephalopathy. Histology revealed an increased inflammatory reaction in the irradiation group, a lesser degree of incorporation of the stent graft, and a lesser degree of endothelialization of the inner surface compared with the non-irradiated group. No significant foreign body reaction was found at any time in any of the animals. The Viatorr stent graft was well tolerated in the pig model. Intraluminal irradiation seemed to have an adverse effect on the healing response. The TIPS patency was prolonged in both the irradiated and non-irradiated group compared with data from the literature; however, seemingly better results were observed in the non-irradiated group.


Assuntos
Politetrafluoretileno , Derivação Portossistêmica Transjugular Intra-Hepática/instrumentação , Stents , Cicatrização/efeitos da radiação , Animais , Radioisótopos de Irídio/uso terapêutico , Suínos
4.
Cardiovasc Intervent Radiol ; 25(4): 275-81, 2002.
Artigo em Inglês | MEDLINE | ID: mdl-12042988

RESUMO

PURPOSE: To assess the efficacy and safety of the Rotarex rotational thrombectomy catheter in treating occlusions of the femoropopliteal arteries. METHODS: The Rotarex catheter (Straub Medical, Switzerland) is a rotational thrombectomy device which is supposed to be able to remove fresh and partially organized clot material from an acutely or subacutely occluded vessel. Nineteen limbs of 18 patients (10 women, 8 men; mean age 72.9 +/- 7.3 years) with acute or subacute (23 +/- 16 days) occlusions of the middle or distal third of the superficial femoral artery or the popliteal artery were treated. The occlusions were 3-20 cm long. RESULTS: Thrombectomy was technically successful in 15 of 19 vessels (79%). The primary procedural success including additional procedures such as angioplasty and/or stent-graft placement in 17 limbs was 94%. The mean ankle-brachial index improved from 0.36 +/- 0.26 (before thrombectomy) to 0.81 +/- 0.21 (2 days after the procedure) (p = 0.012). Clinical symptoms shifted to at least one Fontaine stage lower in 13 limbs. As complications we observed two perforations (arteries showing heavily calcified plaques), one arteriovenous fistula and three distal embolizations. One perforation, the fistula and one intimal tear after percutaneous transluminal angioplasty were treated with covered stents; the three distal embolizations were treated successfully with aspiration or Rotarex thrombectomy. In the other perforation the intervention was terminated. None of the complications needed surgical treatment. The complication rate was 31.5%. Follow-up studies showed three early (4-11 days) and six late (1-6 months) reocclusions. The cumulative primary patency rate was 68 +/- 12% at 3 months, and 39 +/- 13% at 6, 12 and 19 months; the secondary patency rate was 68 +/- 12% at 3 months and 53 +/- 13% at 6, 12 and 20 months. CONCLUSION: The Rotarex thrombectomy catheter is effective and quick in treating acute and subacute occlusions of the superficial femoral and popliteal arteries. It should not be used in arteries with heavily calcified plaques because of the risk of perforation. Limited long-term patency is mainly due to the complexity of the underlying lesion. Our results suggest that the Rotarex mechanical thrombectomy catheter is effective and might serve as an alternative treatment modality to intra-arterial lysis.


Assuntos
Cateterismo/instrumentação , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/cirurgia , Artéria Poplítea/diagnóstico por imagem , Artéria Poplítea/cirurgia , Trombectomia/instrumentação , Trombose/diagnóstico por imagem , Trombose/terapia , Idoso , Angiografia Digital , Feminino , Seguimentos , Humanos , Masculino , Rotação , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...