Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Eur J Radiol ; 170: 111242, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38043382

RESUMO

PURPOSE: Cerebral arterial gas embolism (CAGE) occurs when air or medical gas enters the systemic circulation during invasive procedures and lodges in the cerebral vasculature. Non-contrast computer tomography (CT) may not always show intracerebral gas. CT perfusion (CTP) might be a useful adjunct for diagnosing CAGE in these patients. METHODS: This is a retrospective single-center cohort study. We included patients who were diagnosed with iatrogenic CAGE and underwent CTP within 24 h after onset of symptoms between January 2016 and October 2022. All imaging studies were evaluated by two independent radiologists. CTP studies were scored semi-quantitatively for perfusion abnormalities (normal, minimal, moderate, severe) in the following parameters: cerebral blood flow, cerebral blood volume, time-to-drain and time-to-maximum. RESULTS: Among 27 patient admitted with iatrogenic CAGE, 15 patients underwent CTP within the designated timeframe and were included for imaging analysis. CTP showed perfusion deficits in all patients except one. The affected areas on CTP scans were in general located bilaterally and frontoparietally. The typical pattern of CTP abnormalities in these areas was hypoperfusion with an increased time-to-drain and time-to-maximum, and a corresponding minimal decrease in cerebral blood flow. Cerebral blood volume was mostly unaffected. CONCLUSION: CTP may show specific perfusion defects in patients with a clinical diagnosis of CAGE. This suggests that CTP may be supportive in diagnosing CAGE in cases where no intracerebral gas is seen on non-contrast CT.


Assuntos
Isquemia Encefálica , Embolia Aérea , Acidente Vascular Cerebral , Humanos , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos , Embolia Aérea/diagnóstico por imagem , Estudos de Coortes , Perfusão , Doença Iatrogênica , Imagem de Perfusão/métodos , Circulação Cerebrovascular/fisiologia
2.
J Thorac Imaging ; 36(5): 286-293, 2021 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-34081643

RESUMO

PURPOSE: Patients with novel coronavirus disease (COVID-19) frequently develop acute respiratory distress syndrome (ARDS) and need invasive ventilation. The potential to reaerate consolidated lung tissue in COVID-19-related ARDS is heavily debated. This study assessed the potential to reaerate lung consolidations in patients with COVID-19-related ARDS under invasive ventilation. MATERIALS AND METHODS: This was a retrospective analysis of patients with COVID-19-related ARDS who underwent chest computed tomography (CT) at low positive end-expiratory pressure (PEEP) and after a recruitment maneuver at high PEEP of 20 cm H2O. Lung reaeration, volume, and weight were calculated using both CT scans. CT scans were performed after intubation and start of ventilation (early CT), or after several days of intensive care unit admission (late CT). RESULTS: Twenty-eight patients were analyzed. The median percentages of reaerated and nonaerated lung tissue were 19% [interquartile range, IQR: 10 to 33] and 11% [IQR: 4 to 15] for patients with early and late CT scans, respectively (P=0.049). End-expiratory lung volume showed a median increase of 663 mL [IQR: 483 to 865] and 574 mL [IQR: 292 to 670] after recruitment for patients with early and late CT scans, respectively (P=0.43). The median decrease in lung weight attributed to nonaerated lung tissue was 229 g [IQR: 165 to 376] and 171 g [IQR: 81 to 229] after recruitment for patients with early and late CT scans, respectively (P=0.16). CONCLUSIONS: The majority of patients with COVID-19-related ARDS undergoing invasive ventilation had substantial reaeration of lung consolidations after recruitment and ventilation at high PEEP. Higher PEEP can be considered in patients with reaerated lung consolidations when accompanied by improvement in compliance and gas exchange.


Assuntos
COVID-19 , Síndrome do Desconforto Respiratório , COVID-19/diagnóstico por imagem , COVID-19/terapia , Feminino , Humanos , Pulmão/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Respiração com Pressão Positiva , Síndrome do Desconforto Respiratório/diagnóstico por imagem , Síndrome do Desconforto Respiratório/terapia , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
5.
Eur Radiol ; 22(8): 1659-64, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22447377

RESUMO

OBJECTIVES: To assess whether short-term feedback helps readers to increase their performance using computer-aided detection (CAD) for nodule detection in chest radiography. METHODS: The 140 CXRs (56 with a solitary CT-proven nodules and 84 negative controls) were divided into four subsets of 35; each were read in a different order by six readers. Lesion presence, location and diagnostic confidence were scored without and with CAD (IQQA-Chest, EDDA Technology) as second reader. Readers received individual feedback after each subset. Sensitivity, specificity and area under the receiver-operating characteristics curve (AUC) were calculated for readings with and without CAD with respect to change over time and impact of CAD. RESULTS: CAD stand-alone sensitivity was 59 % with 1.9 false-positives per image. Mean AUC slightly increased over time with and without CAD (0.78 vs. 0.84 with and 0.76 vs. 0.82 without CAD) but differences did not reach significance. The sensitivity increased (65 % vs. 70 % and 66 % vs. 70 %) and specificity decreased over time (79 % vs. 74 % and 80 % vs. 77 %) but no significant impact of CAD was found. CONCLUSION: Short-term feedback does not increase the ability of readers to differentiate true- from false-positive candidate lesions and to use CAD more effectively. KEY POINTS: • Computer-aided detection (CAD) is increasingly used as an adjunct for many radiological techniques. • Short-term feedback does not improve reader performance with CAD in chest radiography. • Differentiation between true- and false-positive CAD for low conspicious possible lesions proves difficult. • CAD can potentially increase reader performance for nodule detection in chest radiography.


Assuntos
Radiografia Torácica/métodos , Radiologia/educação , Nódulo Pulmonar Solitário/diagnóstico por imagem , Nódulo Pulmonar Solitário/diagnóstico , Área Sob a Curva , Estudos de Casos e Controles , Diagnóstico por Computador , Reações Falso-Positivas , Humanos , Pulmão/diagnóstico por imagem , Pessoa de Meia-Idade , Variações Dependentes do Observador , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Radiologia/métodos , Estudos Retrospectivos , Sensibilidade e Especificidade
6.
AJR Am J Roentgenol ; 197(5): 1096-100, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22021501

RESUMO

OBJECTIVE: The purpose of this article is to evaluate the impact of gray-scale reversal on the detection of small pulmonary nodules in two-view chest radiography. MATERIALS AND METHODS: One hundred twenty-eight patients (mean age, 62 years) who underwent CT and chest radiography within 6 weeks were retrospectively selected for this study. Seventy-three percent of patients showed variable degrees of radiographic findings of a "dirty lung." A total of 129 solid pulmonary nodules were present in 74 patients (nodule diameter range, 5-30 mm; mean diameter, 13 mm). The remaining 54 patients served as negative control subjects. Six readers with varying experience levels evaluated the images without and with the availability of gray-scale reversal in two separate reading sessions. Figure of merit (FOM), sensitivity per lesion, mean number of false-positive marks per image, and accuracy were calculated. RESULTS: Five of the six readers showed a slight increase in sensitivity with the use of gray-scale reversal, but on average, the difference was not significant (48% vs 50%; p > 0.05). The mean number of false-positive marks per image also nonsignificantly increased from 0.20 to 0.23. The increases in both sensitivity and the mean number of false-positive marks per image translated into nonsignificant decreases in average FOM (0.79 vs 0.77) and accuracy (72% vs 71%). Data analysis of subgroups of nodules or different reader groups, depending on level of experience, did not reveal significant differences. CONCLUSION: Using PACS display of digital chest radiographs, gray-scale reversal does not help the radiologists in detecting pulmonary nodules.


Assuntos
Neoplasias Pulmonares/diagnóstico por imagem , Intensificação de Imagem Radiográfica/métodos , Radiografia Torácica , Nódulo Pulmonar Solitário/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Distribuição de Qui-Quadrado , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Curva ROC , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Sistemas de Informação em Radiologia , Estudos Retrospectivos , Sensibilidade e Especificidade
7.
Acad Radiol ; 18(12): 1507-14, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-21963532

RESUMO

RATIONALE AND OBJECTIVES: To evaluate the impact of computer-aided detection (CAD, IQQA-Chest; EDDA Technology, Princeton Junction, NJ) used as second reader on the detection of small pulmonary nodules in chest radiography (CXR). MATERIALS AND METHODS: A total of 113 patients (mean age 62 years) with CT and CXR within 6 weeks were selected. Fifty-nine patients showed 101 pulmonary nodules (diameter 5-15mm); the remaining 54 patients served as negative controls. Six readers of varying experience individually evaluated the CXR without and with CAD as second reader in two separate reading sessions. The sensitivity per lesion, figure of merit (FOM), and mean false positive per image (mFP) were calculated. Institutional review board approval was waived. RESULTS: With CAD, the sensitivity increased for inexperienced readers (39% vs. 45%, P < .05) and remained unchanged for experienced readers (50% vs. 51%). The mFP nonsignificantly increased for both inexperienced and experienced readers (0.27 vs. 0.34 and 0.16 vs. 0.21). The mean FOM did not significantly differ for readings without and with CAD irrespective of reader experience (0.71 vs. 0.71 and 0.84 vs. 0.87). All readers together dismissed 33% of true-positive CAD candidates. False-positive candidates by CAD provoked 40% of all false-positive marks made by the readers. CONCLUSION: CAD improves the sensitivity of inexperienced readers for the detection of small nodules at the expense of loss of specificity. Overall performance by means of FOM was therefore not affected. To use CAD more beneficial, readers need to improve their ability to differentiate true from false-positive CAD candidates.


Assuntos
Diagnóstico por Computador , Nódulos Pulmonares Múltiplos/diagnóstico por imagem , Radiografia Torácica , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Competência Clínica , Reações Falso-Positivas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Sensibilidade e Especificidade , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...