Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Vet Comp Orthop Traumatol ; 34(3): 206-213, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33202427

RESUMO

OBJECTIVE: The aim of this study was to describe the coagulation status of traumatized dogs over the first 24 hours after admission. STUDY DESIGN: In 33 dogs presenting within 6 hours after trauma blood was sampled for rotational thromboelastometry (ROTEM), thrombocyte number and venous blood gas analysis at presentation and 6 and 24 hours thereafter. At each time point, dogs were defined as hypo-, normo- or hypercoagulable based on extrinsic, intrinsic and fibrinogen ROTEM profiles. RESULTS: Significantly more dogs (11/33) presented hypocoagulable compared with 6 hours (p = 0.046) and 24 hours (p = 0.008) thereafter and none presented hypercoagulable. Significantly more dogs were hypercoagulable (6/23, p = 0.014) and no dog was hypocoagulable at 24 hours compared with presentation. All evaluated ROTEM parameters except maximum lysis were significantly more hypocoagulable at presentation compared with 24 hours thereafter. CONCLUSION: Hypocoagulability is more common in acutely traumatized dogs than previously described. Dogs were hypo- or normocoagulable at presentation and the coagulation status changed to normo- or hypercoagulability over the first 24 hours. Clotting times, clot formation and clot firmness but not clot lysis were significantly altered at presentation compared with 24 hours and fibrinogen concentration or function may play an important role in the dynamic change of coagulation state over time.


Assuntos
Hemostasia , Tromboelastografia , Animais , Coagulação Sanguínea , Testes de Coagulação Sanguínea/veterinária , Cães , Contagem de Plaquetas/veterinária , Tromboelastografia/veterinária
2.
J Feline Med Surg ; 19(8): 831-840, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27542821

RESUMO

Objectives The aim of this study was to determine in-house reference intervals (RIs) for venous blood analysis with the RAPIDPoint 500 blood gas analyser using blood gas syringes (BGSs) and to determine whether immediate analysis of venous blood collected into lithium heparin (LH) tubes can replace anaerobic blood sampling into BGSs. Methods Venous blood was collected from 24 healthy cats and directly transferred into a BGS and an LH tube. The BGS was immediately analysed on the RAPIDPoint 500 followed by the LH tube. The BGSs and LH tubes were compared using paired t-test or Wilcoxon matched-pairs signed-rank test, Bland-Altman and Passing-Bablok analysis. To assess clinical relevance, bias or percentage bias between BGSs and LH tubes was compared with the allowable total error (TEa) recommended for the respective parameter. Results Based on the values obtained from the BGSs, RIs were calculated for the evaluated parameters, including blood gases, electrolytes, glucose and lactate. Values derived from LH tubes showed no significant difference for standard bicarbonate, whole blood base excess, haematocrit, total haemoglobin, sodium, potassium, chloride, glucose and lactate, while pH, partial pressure of carbon dioxide and oxygen, actual bicarbonate, extracellular base excess, ionised calcium and anion gap were significantly different to the samples collected in BGSs ( P <0.05). Furthermore, pH, partial pressure of carbon dioxide and oxygen, extracellular base excess, ionised calcium and anion gap exceeded the recommended TEa. Conclusions and relevance Assessment of actual and standard bicarbonate, whole blood base excess, haematocrit, total haemoglobin, sodium, potassium, chloride, glucose and lactate can be made based on blood collected in LH tubes and analysed within 5 mins. For pH, partial pressure of carbon dioxide and oxygen, extracellular base excess, anion gap and ionised calcium the clinically relevant alterations have to be considered if analysed in LH tubes.


Assuntos
Gasometria/veterinária , Coleta de Amostras Sanguíneas/veterinária , Gatos/sangue , Animais , Gasometria/instrumentação , Glicemia , Cálcio/sangue , Dióxido de Carbono/sangue , Feminino , Concentração de Íons de Hidrogênio , Ácido Láctico/sangue , Masculino , Potássio/sangue , Valores de Referência
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...